Rental Power QSB7 series engine

Similar documents
Rental Power QSL9 series engine

Diesel generator set QSL9 series engine

Rental Power KTA50 G3 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Diesel generator set QST30 series engine

Diesel generator set QSK78 series engine

Diesel generator set QSB7 series engine

Diesel generator set QSX15 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Diesel generator set 6BT5.9 series engine

Diesel generator set QSK50 series engine

Diesel generator set QSK23 series engine

Diesel generator set QSK78 series engine

Rental Power 4BTAA3.3 series engine

Diesel generator set 4BT3.3 series engine

Diesel generator set QSK60 series engine

Diesel generator set QSK60 series engine

Diesel generator set QSK60 series engine

Diesel Generator set QSK50 series engine 1135 kw-1500 kw 60 Hz EPA emissions

Diesel generator set QSL9-G7 series engine

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Rental Power Kubota V2403 series engine

Diesel generator set QSX15 series engine

Diesel Generator set QSK95 series engine

Diesel Generator set QSK95 series engine

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set QSK60 series engine

Spark-ignited generator set

Spark-ignited generator set

Diesel generator set QSK23 series engine

Diesel generator set QSK95 series engine

Spark-ignited generator set

Tier4 certified diesel generator set QSK50 series engine

Rental Power 1500 kw. Specification sheet. Description. Features. Options

Tier4 certified diesel generator set QSK78 series engine

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Diesel Generator Set S3.8 Series Engine

Diesel generator set QSL9 series engine

Rental Power 800 kw. Specification sheet. Description. Features. Options

Diesel generator set C17D5T series

Diesel Generator Set Model DFBF 60 Hz

Diesel Generator Set Model DGDB 60 Hz

Diesel Generator Set Model DFCE 60 Hz

2000kW Rental Package

Spark-Ignited Generator Set Model GGLA 60 Hz

Model DFEH 60 Hz EPA Emissions

Gaseous Fuel Generator Set Model GFDA

Model DKAC 60 Hz EPA Emissions

Diesel Generator Set Model DFJD 60 Hz

Spark-Ignited Generator Set Model GGFD 60 Hz

Model DSHAE 60 Hz EPA Emissions

Diesel Generator Set Model DSHAD 60 Hz EPA Emissions

500 KW / 625 KVA POWERED by

Gaseous Fuel Generator Set QSK19G Engine Series

55 KW / 70 KVA POWERED by

Spark-Ignited Generator Set Model GGKD 60 Hz

Diesel Generator Set Model DFHB 60 Hz

Gaseous Fuel Generator Set KTA19G Engine Series

Spark-Ignited Generator Set Model GGKC 60 Hz

130 KW / 165 KVA POWERED by

400 KW / 500 KVA. POWERED by TP-JD400-T3-60-UL. kva 500 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

300 KW / 375 KVA POWERED by

640 KW / 800 KVA POWERED by

28 KW / 28 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

45 KW / 55 KVA POWERED by

Model DFHD 60 Hz EPA Emissions

16 KW / 20 KVA POWERED by

80 KW / 100 KVA POWERED by

1800 KW / 2250 KVA POWERED by

700 KVA / 550 KW POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

30 KW / 40 KVA POWERED by

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

204 KW / 254 KVA POWERED by

1000 KW / 1250 KVA POWERED by

2000 KW / 2500 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

19 KW / 24 KVA POWERED by

105 KW / 130 KVA. POWERED by TP-I100-T2-60. kva 130 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 125 Prime Power Factor 0.

64 KW / 80 KVA POWERED by

70 KW / 90 KVA POWERED by

600 KW / 750 KVA POWERED by

60 KW / 75 KVA POWERED by

20 KW / 25 KVA LIQUID COOLED POWERED by

KTA50 Land Based Drilling Power Modules

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

130 KW / 165 KVA POWERED by

18 KW / 18 KVA POWERED by

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

55 KW / 69 KVA POWERED by

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

Better Soundproof, Better Life!

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PowerCommand 1.1 control system

Transcription:

Specification sheet Rental Power QSB7 series engine 150 kva 200 kva 50 Hz 135 kw 180 kw 60 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing optimum performance, reliability, and versatility for Prime Power. Cummins rugged heavy-duty engine - Rugged 4-cycle industrial diesel delivers reliable power, low emissions and fast response to load changes. Permanent Magnet Generator (PMG) - Offers enhanced motor starting and fault clearing short circuit capability. Alternator - Low reactance 2/3 pitch windings; low waveform distortion with non-linear loads, fault clearing short-circuits capability, and class H insulation. Cooling system - Standard integral setmounted radiator system, designed and tested for rated ambient temperatures. Control system - The PowerCommand electronic control is standard equipment and provides total system integration, including auto remote start/stop, alarm and status message display. Enclosures - Sound-attenuated with built in fork pockets and easy access to serviceable items including controls, cable entry and radiator. Warranty - Backed by a comprehensive warranty and worldwide distributor network. Model Standby rating 50 Hz 60 Hz Prime rating 50 Hz 60 Hz kw (kva) Emissions compliance Controller Datasheet C150 D2R 165 (132) 150 (188) 150 (120) 135 (169) EU SIIIA 1.2/3.3 C200 D2R 220 (176) 200 (250) 200 (160) 180 (225 EU SIIIA 1.2/3.3 EMERD- 5930 EMERD- 5931

Generator set specifications Governor regulation class ISO 8528 Voltage regulation, no load to full load ± 1% Random voltage variation ± 1% Frequency regulation Isochronous Random frequency variation ± 0.5% EMC compatibility BS EN61000-6-4 / BS EN61000-6-2 Engine specifications Design Bore Stroke Displacement Cylinder block Battery capacity Battery charging alternator Starting voltage Fuel system Fuel filter Air cleaner type Lube oil filter type(s) Standard cooling system 4 cycle, in-line, turbocharged, charge air-cooled 107 mm 124 mm 6.7 L Cast iron, 6 cylinder 75 AH 100 Amps 12 Volt, negative ground Direct injection Spin on fuel filters with water separator Dry replacement element Spin on full flow filter 50 C ambient radiator Alternator specifications Design Stator Rotor Insulation system Standard temperature rise Exciter type Phase rotation Alternator cooling Brushless, single bearing, revolving field 2/3 pitch Single bearing, flexible disc Class H Prime 125 C temp rise @ 40 C ambient Standby 163 C temp rise @ 27 C ambient Self-excited or separately excited by PMG A (U), B (V), C (W) Direct drive centrifugal blower fan AC waveform total harmonic distortion (THDV) No load < 1.5%. Non distorting balanced linear load <5% Telephone influence factor (TIF) Telephone harmonic factor (THF) < 2% < 50% per NEMA MG1-122/43 Available voltages 50 Hz Line Neutral/Line - Line 60 Hz Line - Neutral/Line - Line 255/440 240/416 230/400 220/380 115/200 110/190 127/220 277/480 266/460 255/440 240/416 139/240 133/230 127/220 120/208

Generator set features* Engine Heavy duty air cleaner Water jacket heater 240 V with connector plug Dual frequency Oil sump pump Enclosure Sound attenuated canopy Earthing studs on each corner Power receptacle socket options Easy cleaning access to radiator Built-in lifting points and forklift pockets Fuel tank Dual wall 110% fully contained design Bund alarm and bund pump Low fuel level warning or shutdown High fuel level warning Three way fuel valve with quick connects Fuel capacity: 1036 L 110% bunded Control panel PowerCommand 1.2 or 3.3 Auto-start on panel Shutdown audible alarm Switchable earth fault shutdown Accessible neutral-earth link Circuit breaker door open switch Low coolant level shutdown *Note: Some options may not be available on all models - consult factory for availability. PowerCommand 1.2 control system The PowerCommand control system is an integrated microprocessor based generator set control system providing voltage regulation, engine protection, alternator protection, operator interface and isochronous governing. Refer to document S-1567 for more detailed information on the control. Major features include: Power management Control function provides battery monitoring and testing features and smart starting control system. Digital voltage regulation Single phase full wave SCR type regulator. Communications interface Control comes standard with PCCNet and Modbus interface. Regulation compliant Prototype tested: CE, UL, and CSA compliant. Service - InPower PC-based service tool available for detailed diagnostics, setup, data logging and fault simulation. Easily upgradeable PowerCommand controls are designed with common control interfaces. Reliable design The control system is designed for reliable operation in harsh environment. Operator panel features 128 x 128 pixels graphic LED backlight LCD Auto, manual, start, stop, fault reset and lamp test/panel lamp switches. Alpha-numeric display with pushbuttons. LED lamps indicating genset running, remote start, not in auto, common shutdown, common warning, manual run mode, auto mode and stop mode. Multiple language support. Circuit breaker 4 pole main circuit breaker Motorised 4 pole circuit breaker with 3.3 control Aux contacts and trip alarm Shunt trip 12 V DC Alternator Alternator heater 240 V with connector plug Exciter voltage regulator (PMG) Warranty Base warranty options 1 year unlimited hours or 3 years 3000 hours Battery Optima Absorbed Glass Mat (AGM) RedTop battery Battery isolation switch standard Battery charger option Low battery voltage warning Alternator data Line-to-Neutral and Line-to-Line AC volts 3-phase AC current Frequency kva (three phase and total) Engine data DC voltage Engine speed Lube oil pressure Coolant temperature Other data Genset model data Start attempts, starts, running hours, kva hours Fault history and control hours time stamp for up to 10 events Data logging and fault simulation (requires InPower). Standard control functions Digital governing Integrated digital electronic isochronous governor Temperature dynamic governing Configurable inputs: Control includes (4) input signals from customer Digital voltage regulation Integrated digital electronic voltage regulator Line to line voltage sensing Configurable torque matching

Engine protection Battery voltage monitoring and protection Overspeed shutdown Low oil pressure warning and shutdown High/low coolant temperature warning or shutdown Low coolant level warning or shutdown Fail to start (overcrank) shutdown Fail to crank shutdown Cranking lockout Sensor failure indication Low fuel level warning or shutdown (optional) Fuel-in-rupture-basin warning or shutdown (optional) Full authority electronic engine protection Battle short to allow some shutdown faults to be Bypassed Control functions Time delay start and cool down Cycle cranking Configurable inputs (4) and outputs (2) Remote emergency stop PowerCommand 3.3 control system with Masterless Load Demand (MLD) The PowerCommand control system is an integrated microprocessor based generator set control system providing voltage regulation, engine protection, alternator protection, operator interface and isochronous governing. Masterless Load Demandcapable generators are equipped with an additional s-can network connection that allows sharing of information amongst paralleled generator sets. MLD has been designed for hassle-free installation, commission and operation. AmpSentry Includes integral AmpSentry protection, which provides a full range of alternator protection functions that are matched to the alternator provided. Power management Control function provides battery monitoring and testing features and smart starting control system. Advanced control methodology Three phase sensing, full wave rectified voltage regulation, with a PWM output for stable operation with all load types. Communications interface Control comes standard with PCCNet and Modbus interface. Regulation compliant Prototype tested: UL, CSA and CE compliant. Service - InPower PC-based service tool available for detailed diagnostics, setup, data logging and fault simulation. Reliable design The control system is designed for reliable operation in harsh environments. Multi-language support

Emergency Standby Power (ESP): Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Limited-Time Running Power (LTP): Applicable for supplying power to a constant electrical load for limited hours. Limited-Time Running Power (LTP) is in accordance with ISO 8528. Prime Power (PRP): Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Base Load (Continuous) Power (COP): Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514. This outline drawing is to provide representative configuration details for Model series only. See respective model data sheet for specific model outline drawing number. Do not use for installation design Model Dim A (m) Dim B (m) Dim C (m) Set weight dry* (kg) Set weight wet* (kg) C150 D2R 3.9 1.1 2.2 2922 2948 C200 D2R 3.9 1.1 2.2 3018 3044 * Note: Weights represent a set with standard features. See outline drawings for weights of other configurations. Codes and standards This generator set is designed in facilities certified to ISO 9001 and manufactured in facilities certified to ISO 9001 or ISO 9002. 2000/14/EC This generator set is available with CE certification. ISO 8528 All enclosed products are designed to meet or exceed EU noise legislation 2000/14/EC step 2006. This generator set has been designed to comply with ISO 8528 regulation For more information contact your local Cummins distributor or visit 2017 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks of Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. EMEAS-5598-EN (08/17)