H3DS-X - Solid State Two-Wire Timer

Similar documents
0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Surface mounting, flush mounting, and DIN track mounting

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Model Number Structure

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Transistor Remote Modules

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

SYSMAC Transistor Remote Module

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Digital display Pressure range ON/OFF output Linear output Model

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Model Number Structure

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Model Number Structure

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Switching Power Supply

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Model Number Structure

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Multiple Plunger Limit Switch

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Ordering Information. Text PCB Power Relay G5LE

General Purpose Relay

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Inductive Proximity Sensor

Model Pressure range ON/OFF output Linear output

Safety-door Switch. Ordering Information

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Inductive Proximity Sensor E2Q2. Ordering Information. Limit Switch Style Proximity Sensor with 5-Position Sensing Head

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

Switching Power Supply

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Model Number Structure

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

Type Terminal Coil Contact form Model

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Power Controller. (see note 1) 10 sec

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

24-hour/Weekly Time Switch H2F

Electronic timers CT-S range Function diagrams

Model Number Structure

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Subminiature Basic Switch

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

E2K-L. Liquid Level Sensor. Applications. Ordering Information

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Electronic timers CT-E range Selection and ordering details

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

General Purpose Relay

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Hinged Safety Door Switch

Model Number Structure

Ordering Information. Text Surface-Mounting Signal Relay G6K

Digital display Pressure range ON/OFF output Linear output Model

Cylindrical Proximity Sensor

E2EZ-X2D1-N E2EZ-X2D2-N

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

General Purpose Relay

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Model Pressure range ON/OFF output Linear output

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

1/16 DIN Temperature Controller E5CS

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Safety Limit Switch

Transcription:

OMRON Analog Set Multifunction Timers H3DS Series To view data sheets, click on any link below: H3DS - Standard Timer H3DS-F - Twin Timer H3DS-G - Star-Delta Timer H3DS-X - Solid State Two-Wire Timer

Multi-function Timer H3DS Analog Set Multi-function, Ultra-Slim 17.5 mm Timers for Track Mounting Wide AC/DC power supply range (24 to 230 VAC/24 to 48 VDC) minimizes inventory Smart Dial/Selector-Locking Mechanism prevents the dials and selectors on the timer s front panel from being operated without authorization (lock can only be unlocked and locked with an optional pen-type Lock Key) Eight operating modes (H3DS-M) and four operating modes (H3DS-S) to cover a wide range of applications Offers wide time setting range of 0.10 s to 120 h Finger protection terminal block prevents shock, meets VDE0106/P100 High immunity to inverter noise Ordering Information Input Operating mode Part number Screw terminal Cage clamp Voltage 8 modes H3DS-ML-AC24-230/DC24-48 H3DS-MLC-AC24-230/DC24-48 input No-input 4 modes H3DS-SL-AC24-230/DC24-48 H3DS-SLC-AC24-230/DC24-48 available Single mode H3DS-AL-AC24-230/DC24-48 H3DS-ALC-AC24-230/DC24-48 Model Number Legend H3DS - L 1 2 3 1. M: Multi-function type (8 modes) S: Standard type (4 modes) A: Single-function type 2. L: Smart lock mechanism 3. None: Screw terminal type C: Cage clamp terminal type Accessories (Order Separately) Description Part number Lock Key Y92S-38 Mounting Track 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S

H3DS H3DS Specifications General Item H3DS-ML@ H3DS-SL@ H3DS-AL@ Operating mode A: ON-delay (Signal or Power) A: ON-delay A: ON-delay (fixed) B: Repeat-cycle OFF-start (Signal or Power) B2: Repeat-cycle ON-start B2: Repeat-cycle ON-start (Signal or Power) E: Interval C: Signal ON/OFF-delay J: One-shot D: Signal OFF-delay E: Interval (Signal or Power) G: Signal ON/OFF-delay J: One-shot (Signal or Power) Input type Voltage input --- Output type Relay: SPDT External connections Screw terminal, cage clamp terminal Terminal block Screw terminal type: Clamps two 2.5-mm 2 max. bar terminals without sleeves. Cage clamp terminal type: Clamps two 1.5-mm 2 max. bar terminals without sleeves. Terminal screw tightening 0.98 N m max. torque Mounting method Attachment Approved standards Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm. Time Ranges Time scale display Time range 0.1 s 0.1 to 1.2 s 1 s 1 to 12 s 0.1 m 0.1 to 1.2 min 1 m 1 to 12 min 0.1 h 0.1 to 1.2 h 1 h 1 to 12 h 10 h 10 to 120 h Ratings DIN track mounting (See Note.) Nameplate label UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kv/2, VDE0106/P100 Output category according to IEC60947-5-1 (AC-13; 250 V 5 A/AC-14; 250 V 1 A/AC-15; 250 V 1 A/DC-13; 30 V 0.1 A/DC-14; 30 V 0.05 A) When the time setting dial is set to 0 for any time scale, the output will operate instantaneously. Rated supply voltage 24 to 230 VAC (50/60 Hz)/24 to 48 VDC (See Notes 1 and 2.) Operating voltage range 85% to 110% of rated supply voltage Power reset Minimum power-off time: 0.1 s Reset voltage 2.4 VAC/DC max. Power consumption (See Note 3.) AC: 32 VA max./3.0 W max. (typical: 30 VA/2.7 W) at 230 VAC 14 VA max./2.2 W max. (typical: 13 VA/2.1 W) at 100 to 120 VAC DC: 0.7 W max. (typical: 0.6 W) at 24 VDC 1.4 W max. (typical: 1.3 W) at 48 VDC Voltage input Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pf Load connectable in parallel with inputs (terminals B1 and A1). H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC L-level: 0 to 2.4 VAC/DC Control output Contact output: 5 A at 250 VAC with resistive load (cosφ = 1); 5 A at 30 VDC with resistive load (cosφ = 1) Ambient temperature Operating: 10 C to 55 C (14 F to 131 F) with no icing Storage: 25 C to 65 C (-13 F to 149 F) with no icing Ambient humidity Operating: 35% to 85% 1. DC ripple rate: 20% max. 2. Since an inrush current of 0.4 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning on or off the power supply to the Timer with a solid-state output such as a sensor. 3. The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption of the H3DS-ML includes the input with the B1 and A1 terminals short-ed.

H3DS H3DS \Characteristics Accuracy of operating time Setting error Signal input time Influence of voltage Influence of temperature Insulation resistance Dielectric strength Vibration resistance Shock resistance Impulse withstand voltage Noise immunity Static immunity Life expectancy EMC Case color Degree of protection Weight ±1% max. of FS (±1% ±10 ms max. at 1.2-s range) ±10% ±50 ms max. of FS 50 ms min. ±0.7% max. of FS (±0.7% ±10 ms max. at 1.2-s range) ±2% max. of FS (±2% ±10 ms max. at 1.2-s range) 100 MΩ min. at 500 VDC Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min. Between control output terminals and operating : 2,000 VAC for 1 min. Between contacts not located next to each other: 1,000 VAC for 1 min. Malfunction: 0.5-mm single amplitude at 10 to 55 Hz Destruction: 0.75-mm single amplitude at 10 to 55 Hz Malfunction: 100 m/s 2 3 times each in 6 directions Destruction: 1,000 m/s 2 3 times each in 6 directions 3 kv (between power terminals) 4.5 kv (between current-carrying metal parts and exposed non-current-carrying metal parts) Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±1.5 kv Malfunction: 4 kv Destruction: 8 kv Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) See Note. (EMI) Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B (EMS) Immunity ESD: EN61000-4-2: 6 kv contact discharge (level 3) 8 kv air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kv power port and output port (level 3) 1 kv control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kv common mode (level 3) 1 kv differential mode (level 3) Light gray (5Y7/1) IP30 (Terminal block: IP20) Approx. 70 g For reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ =1). A maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 ma at 5 VDC (failure level: P).

H3DS H3DS Nomenclature H3DS-ML@ /-SL@ H3DS-MLC/-SLC Wire connection holes Output indicator (orange) (Lit while Timer output is ON.) Set time window Time scale display window and selector (select one from 1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, and 0.1 m) Time setting dial (set time) Lock for time setting dial Lock for time scale selector Release holes Lock for operating mode selector Operating mode display window and selector (select the mode from A, B, B2, C, D, E, G, and J for the H3DS-ML, from A, B2, E, and J for the H3DS-SL) Power-ON indicator (green) (Lit while the power is ON.) 18 16 A2 (Front View) H3DS-AL@ (Front View) H3DS-ALC Wire connection holes Wire connection holes Output indicator (orange) (Lit while Timer output is ON.) Set time window Time scale display window and selector (select one from 1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, and 0.1 m) Time setting dial (set time) Lock for time setting dial Lock for time scale selector Release holes Power-ON indicator (green) (Lit while the power is ON.) 18 16 A2 (Front View) (Front View) Wire connection holes Attach the enclosed label here as a nameplate. (The label is attached to the Timer's DIN Track hook section at the time of shipment.)

H3DS H3DS Operation Block Diagram H3DS-ML@ AC (DC) input Zero setting detection Time scale/ unit selectors Operating mode selector Power supply Oscillation Counting Output Start input Input Indicator Power-ON indicator Output indicator H3DS-SL@/-AL@ AC (DC) input Zero setting detection Time scale/ unit selectors Operating mode selector Power supply Oscillation Counting Output Indicator Power-ON indicator Output indicator I/O Functions Item H3DS-ML@ H3DS-SL@/-AL@ Input Start Starts operation. No input is available. Output Control output Outputs are turned ON according to designated output mode when preset value is reached. Outputs are turned ON according to designated output mode when preset value is reached.

H3DS Basic Operation Setting of Selector The selectors can be turned clockwise and counterclockwise to select the desired time scale or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position where it is secured. Do not set it midway between two secure positions, or a malfunction could result from improper setting. Selection of Operating Mode (except for H3DS-AL) The H3DS-ML/-SL can be set to any one of the operating modes A to J. Turn the operating mode selector with a screwdriver until the desired operating mode appears in the operating mode display window. H3DS-ML (8 modes): A, B, B2, C, D, E, G, J (In order of appearance) H3DS-SL (4 modes): A, E, B2, J, E, E, J, J (In order of appearance) Letters that appear more than once indicate exactly the same operating mode. Selection of Time Scale H3DS Locking/Unlocking of Selectors and Time Setting Dial The time setting dial, time scale selector, and operating mode selector can be locked using the Y92S-38 Lock Key, a special pen-type tool that is sold separately. To lock the dial or selectors, insert the Lock Key in the keyhole to the lower right of the dial or selector and turn it clockwise until the dial or selector is completely covered with the red cover. To unlock, turn the Lock Key in the opposite direction. Key hole The time scale is selected by turning the time scale selector. The time scales will appear (in the time scale display window to the left of the selector) in the order shown here: 1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, 0.1 m. The time scale 1h appears twice. Both instances indicate exactly the same time scale. Time scale display window and selector Operating mode display window and selector

H3DS H3DS Timing Chart 1. The minimum power reset time is 0.1 s and the minimum signal input time is 0.05 s. 2. The letter t in the timing charts stands for the set time and t a means that the period is less than the time set. Operating mode A: ON-delay Timing chart t t-a t Power (A 1 and A 2) Basic operation Start (B 1 and A 2) (see note) Output relay: NC 15 and 16 Power * Start ** t Output relay: NO (output indicator) 15 and 18 Power indicator Output * For power-on operation, impose voltage to the Start input. The Timer starts operating at the moment the power is turned on. ** Start input is invalid while the Timer is in operation. B: Repeatcycle OFF-start Power (A 1 and A 2) t t t-a t t t t-a Basic operation Start (B 1 and A 2) (see note) Output relay: NC 15 and 16 Output relay: NO (output indicator) 15 and 18 Power indicator Power * Start Output ** t t t t * For power-on operation, impose voltage to the Start input. The Timer starts operating at the moment the power is turned on. ** Start input is invalid while the Timer is in operation. B2: Repeatcycle ON- start Power (A 1 and A 2) t t t-a t t t t-a Basic operation Start (B 1 and A 2) (see note) Power C: Signal ON/OFFdelay Output relay: NC 15 and 16 * Start t t t t Output relay: NO Output (output indicator) 15 and 18 * For power-on operation, impose voltage to the Start input. The Timer starts operating at the moment the power is turned on. Power indicator ** Start input is invalid while the Timer is in operation. Power (A 1 and A 2) t t t t-a t t-a ** Start (B 1 and A 2) (see note) Basic operation Output relay: NC 15 and 16 Output relay: NO (output indicator) 15 and 18 Power Start Output * t t t t Power indicator * Start input is invalid while the Timer is in operation. The start input of the H3DS-ML@ model is activated by applying a voltage to B1 and A2 terminals.the voltage can be applied by turning on the contact between B1 and A1. Refer to Terminal Arrangement. (This chart continues on the following page.)

H3DS H3DS Timing Chart - continued from the previous page. 1. The minimum power reset time is 0.1 s and the minimum signal input time is 0.05 s. 2. The letter t in the timing charts stands for the set time and t a means that the period is less than the time set. Operating mode D: Signal OFF-delay Timing chart Power (A 1 and A 2 ) t t-a t-a t t-a Start (B 1 and A 2 ) (see note) Output relay: NC 15 and 16 Output relay: NO (output indicator) 15 and 18 Basic operation Power * Start Output t Power indicator * Start input is valid and re-triggerable while the Timer is in operation. E: Interval t t t-a t-a t Power (A 1 and A 2 ) Basic operation Power Start (B 1 and A 2 ) (see note) Output relay: NC 15 and 16 * Start Output ** t Output relay: NO (output indicator) 15 and 18 Power indicator * For power-on operation, impose voltage to the Start input. The Timer starts operating at the moment the power is turned on. ** Start input is valid and re-triggerable while the Timer is in operation. G: Signal ON/OFFdelay Power (A 1 and A 2 ) Start (B 1 and A 2 ) (see note) Output relay: NC 15 and 16 Output relay: NO (output indicator) 15 and 18 Power indicator Power Start Output Basic operation * t t t t * Start input is valid and re-triggerable while the Timer is in operation. J: One-shot output (ON delay) Power (A 1 and A 2 ) Start (B 1 and A 2 ) (see note) Output relay: NC 15 and 16 Output relay: NO (output indicator) 15 and 18 Power indicator Approx. 1±0.6 s (fixed) t t t-a t-a t Approx. 1±0.6 s (fixed) Approx. 1±0.6 s (fixed) Power * Start Output Basic operation ** t Approx. 1±0.6 s (fixed) * For power-on operation, impose voltage to the Start input. The Timer starts operating at the moment the power is turned on. ** Start input is valid and re-triggerable while the Timer is in operation. The start input of the H3DS-ML@ model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement).

H3DS H3DS Dimensions Unit: mm (inch) H3DS-ML/-SL/-AL 17.5 (0.69) Surface color: Light gray 5Y7/1 (OMRON) 73 (2.87) 45 (1.77) 80 (3.15) 68 (2.68) H3DS-MLC/-SLC/-ALC 17.5 (0.69) 73 (2.87) 73 45 (1.77) 45 80 80 (3.15) 44 68 (2.68)

H3DS H3DS Accessories (Order Separately) Unit: mm (inch) Lock Key Y92S-38 100 (3.94) 6.4 Mounting Track PFP-100N, PFP-50N PFP-100N2 4.5 7.3±0.15 35±0.3 27±0.15 4.5 35±0.3 27 24 16 29.2 15 25 25 25 25 10 PFP-100N: 1 m PFP-50N: 0.5 m 10 PFP-100N: 15 mm PFP-50N: 5 mm 1 15 25 25 25 25 15 10 10 1 m 1 1.5 End Plate PFP-M 10 6.2 1.8 Spacer PFP-S 5 16 12 50 1 35.5 35.3 1.8 44.3 34.8 11.5 10 M4 x 8 pan head screw 1.3 4.8 16.5

H3DS H3DS Installation Terminal Arrangement H3DS-MLC H3DS-ML H3DS-SLC/-ALC H3DS-SL/-AL A1 15 B1 A1 15 A1 15 B1 A1 15 15 15 L 15 15 18 16 18 16 18 16 18 16 18 16 A2 18 16 A2 18 16 A2 18 16 A2 (see note 1) 1. DC supply voltage does not require the designation of polarity. 2. The contact symbol for the H3DS is indicated with because it offers multiple operating modes and is different from the delayed contact for conventional timers. Input Connections The inputs of the H3DS-ML@ are voltage (voltage imposition or open) inputs. (see note 1) No-contact Input (Connection to PNP output sensor.) Sensor No-contact Input (Connection to NPN output sensor.) Timer Contact Input Timer (+) 24 VDC (-) A 2 Timer (+) 24 VDC (-) B1 Start A 2 A 1 B 1 A 1 B1 Start A 2 A 1 Operates with PNP transistor ON Sensor Operates with NPN transistor ON Operates with relay ON Voltage Input Signal Levels No-contact input 1. Transistor ON Residual voltage: 1 V max. (Voltage between terminals B 1 and A 2 must be more than the rated "H-level" voltage (20.4 VDC min.).) 2. Transistor OFF Leakage current: 0.01 ma max. (Voltage between terminals B 1 and A 2 must be less than the rated "L-level" voltage (2.4 VDC max.).) Contact input Use contacts that can adequately switch 0.1 ma at each voltage to be imposed. (When the contacts are ON or OFF, voltage between terminals B 1 and A 2 must be within the following ranges: When contacts are ON: 20.4 to 253 VAC/20.4 to 52.8 VDC When contacts are OFF: 0 to 2.4 VAC/DC

H3DS H3DS Tools A flat-blade screwdriver should be used to install the cables. Applicable Screwdriver Flat-blade, Parallel-tip, 2.5 mm diameter Flat-blade, Parallel-tip Use the following procedure: 1. Insert the specified screwdriver into the release hole located beside the wire connection hole where the wire is to be inserted. Wire connection holes Release holes A A 2.5 dia. Flat-blade, Flared-tip Fig. 2 Wire Connection Holes and Release Holes Wire connection hole Cannot be used. Release hole Examples:FACOM AEF.2.5 75E VESSEL No. 9900-(-)2.5 75 WAGO 210-119 WIHA 260/2.5 40 Fig. 3 Section A-A of Fig. 2 Screwdriver Insert Applicable Wires Applicable Wire Sizes 0.2 to 1.5 mm 2, AWG24 to AWG16 Applicable Wire Type Solid wires, stranded wires, flexible wires, or wires with ferrules can be used. (See note 1) < 1.8 Diameter D (mm) 3.0 (See Note 2.) Conductor diameter d (mm) or length of sides a and b (mm) 1.6 2. Insert the exposed conductor into the wire connection hole. Insert 3. Pull out the screwdriver. Insert Wires with Ferrules Pull out 1. If the overall diameter of the wire is less than 1.8 mm, do not insert the wire past the conductor. Refer to the following diagrams. 2. If the overall diameter of the wire is over 2.8 mm, it will be difficult to use double wiring. Wiring Precautions Always insert the screwdriver straight into the hole, never at an angle. The clamp spring may bend if the screwdriver is not straight. OK NG Do not move the screwdriver side to side in the clamp hole. The clamp spring may bend if the screwdriver is moved sideways. Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 6 to 7 mm. Fig. 1 Exposed Conductor Length 6 to 7 mm

H3DS Precautions Setting Changes!WARNING Do not change the time scale or operating mode while the Timer is in operation, or malfunction could result. Power Supplies The H3DS Series has a transformerless power supply system. Touching the input terminal while power is being supplied can cause you to get an electrical shock. Use the bar terminal for wiring the H3DS. Using a stranded-wire terminal may cause a short- due to a stray wire entering into the Timer. Both AC and DC power supplies can be connected to the power input terminals without regard to polarity. A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. Make sure that the voltage is applied within the specified range, or the internal elements of the Timer may be damaged. Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value at once, or the Timer may not be reset or a timer error could result. For the power supply of an input device of the H3DS-ML@, use an isolating transformer where the primary and secondary windings are mutually isolated, and the secondary winding is not grounded. B1 Start input A1 H3DS-ML@ A2 Power supply Installation H3DS H3DS H3DS t t t: Mounting clearance (mm) H3DS If the load current is continuously being supplied to the Timer for a long period of time, be sure to provide the mounting clearance as shown in the figure below. If used under conditions other than those specified below, the life of internal components may be shortened due to an excessive rise in the internal temperature. DIN track Switching Current vs. Ambient temperature (When Mounting Two or More H3DS Units Side-by-Side) Ambient temperature ( C) 70 60 50 40 30 Mounting clearance: 50 mm min. Mounting clearance: 10 mm Mounting clearance: 5 mm Maximum range of operating ambient temperature Mounting clearance: 0 mm Circuit Rectifier Isolation transformer is required. 0 1 2 3 4 5 Load current (A) (Measurement Condition: Input voltage of 230 VAC)

H3DS Input/Output Relationship between Input and Power Supply Circuits (H3DS-ML@) AC/DC power supply B1 Input Power supply Since the input and the power supply are configured independently, the input can be turned on or off regardless of the on/off state of the power supply. It must be noted that a voltage equivalent to the power supply voltage is applied to the input. When connecting a relay or a transistor as an external signal input device, pay attention to the following points to prevent shorting due to a sneak current to the transformerless power supply. If a relay or transistor is connected to two or more Timers, the input terminals of those Timers must be wired properly so that they will not be different in phase or the terminals will be shorted to one another (refer to the figures below). Incorrect Contact or transistor for external input signal Short- current B1 B1 A1 H3DS-ML@ A2 A1 H3DS-ML@ A2 A2 A1 Power supply Precautions for EN61812-1 Conformance H3DS The H3DS as a built-in timer conforms to EN61812-1 provided that the following conditions are satisfied: The output section of the H3DS is provided only with basic isolation. To ensure reinforced isolation required by the EN61812-1, provide supplementary basic isolation on the load side connected to the output. The H3DS itself is designed according to the following: Overvoltage category III Pollution degree 2 On the above basis: Operation parts on the front and bottom: Reinforced isolation With clearance of 5.5 mm and creepage distance of 5.5 mm at 230 VAC Output: Basic isolation With clearance of 3 mm and creepage distance of 3 mm at 230 VAC Environment When using the Timer in an area with excess electrical noise, separate the Timer, wiring, and the equipment which generates the input signals as far as possible from the noise sources. Shield the input signal wiring to prevent electrical interference. Organic solvents (such as paint thinner), as well as very acidic or basic solutions, can damage the outer casing of the Timer. Do not use the Timer in places where it is exposed to dust, corrosive gas, or direct sunlight. When storing the Timer, make sure that the ambient temperature and humidity are within the rated values. Leave the Timer at room temperature for at least three hours before using the Timer if it has been stored at an ambient temperature of 10 C or below. Voltage Withstand Test If the Timer is mounted on a control board, remove the Timer from the control board or short- the ry of the power board before carrying out a voltage withstand test between the electrical ry and non-current-carrying metal part of the Timer, in order to prevent the internal ry of the Timer from damage. Contact or transistor for external input signal A1 Correct B1 H3DS-ML@ Power supply Short- current A2 A1 B1 H3DS-ML@ A2 The H3DS Series is provided with a transformerless power supply system.

H3DS H3DS ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No. GC TMCN1 3/02 Specifications subject to change without notice Printed in USA

Twin Timer H3DS-F 17.5 mm Twin Timer Designed For Track Mounting Wide AC/DC power supply range, 24 to 230 VAC/24 to 48 VDC Independent long or short ON-/OFF-time settings are possible Smart Dial/Selector-Locking Mechanism prevents the dials and selectors on the Timer s front panel from being operated without authorization. (The Lock can only be unlocked and locked with an optional pen-type Lock Key.) Repeat-cycle can be set for ON-start or OFF-start by terminal connection Time range from 0.1 second to 12 hours Finger-protection terminal block Ordering Information Timers Description Supply voltage Part number Screw terminal type Cage clamp type Independent ON-time/ Off-time operation 24 to 230 VAC (50/60 Hz)/24 to 48 VDC H3DS-FL AC 24-230/DC 24-48 H3DS-FLC AC 24-230/DC 24-48 Model Number Legend H3DS -F L 1 2 3 1. F: Twin timer 2. L: Smart lock mechanism 3. None: Screw terminal type C: Cage clamp type Accessories (Order Separately) Description Part number Lock key Y92S-38 Mounting track 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End plate PFP-M Spacer PFP-S

H3DS-F Specifications General H3DS-F Item Operating mode Output type External connections Terminal block Terminal screw tightening torque Mounting method Attachment Approved standards H3DS-F Repeat-cycle with independent ON-time/OFF-time settings Relay: SPDT Screw terminal, cage clamp type Screw terminal type: Clamps two 2.5-mm 2 max. bar terminals without sleeves. Cage clamp type: Clamps two 1.5-mm 2 max. bar terminals without sleeves. 0.98 N m max. DIN track mounting (see note) Nameplate label UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kv/2, VDE0106/P 100 Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/DC-13; 30 V 0.1 A) Can be mounted to 35 mm D I N Track with a plate thickness of 1 to 2.5 mm. Time Ranges Time scale display Time range 0.1s 0.1 to 1.2 1 s 1 to 12 s 0.1 m 0.1 to 1.2 min 1 m 1 to 12 min 0.1 h 0.1 to 1.2 h 1 h 1 to 12 h Ratings When the time setting dial is set to 0 for any time scale, the output will operate instantaneously. Rated supply voltage (See note.) Operating voltage range Power reset Reset voltage Power consumption Voltage input 24 to 230 VAC (50/60 Hz)/24 to 48 VDC 85% to 110% of rated supply voltage Minimum power-off time: 0.1 s 2.4 VAC/DC max. AC: 33 VA max./2.2 W max. (typical: 31 VA/2.0 W) at 230 VAC;11 VA max./1.9 W max. (typical: 9.7 VA/1.7 W) at 100 to 120 VAC DC: 0.7 W max. (typical: 0.6 W) at 24 VDC;1.4 W max. (typical: 1.2 W) at 48 VDC Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pf Load connectable in parallel with inputs (terminals B1 and A1). H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC L-level: 0 to 2.4 VAC/DC Control output Contact output: 5 A at 250 VAC with resistive load (cos φ = 1); 5 A at 30 VDC with resistive load (cos φ = 1) Ambient temperature Operating: 10 C to 55 C (14 F to 131 F) with no icing Storage: 25 C to 65 C (-13 F to 145 F) with no icing Ambient humidity Operating: 35% to 85% DC ripple rate: 20% max.

H3DS-F H3DS-F Characteristics Accuracy of operating time Setting error Influence of voltage Influence of temperature Insulation resistance Dielectric strength Impulse withstand voltage Noise immunity Static immunity Vibration resistance Shock resistance Life expectancy EMC Case color Degree of protection Weight ±1% max. of FS (±1% ±10 ms max. at 1.2-s range) ±10% ±50 ms max. of FS ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2-s range) ±2% max. of FS (±2% ±10 ms max. at 1.2-s range) 100 MΩ min. at 500 VDC Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1 min. Between control output terminals and operating : 2,000 VAC (50/60 Hz) for 1 min. Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min. 3 kv (between power supply terminals) 4.5 kv (between current-carrying metal parts and exposed non-current-carrying metal parts) Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±1.5 kv Malfunction: 4 kv Destruction: 8 kv Malfunction: 0.5-mm single amplitude at 10 to 55 Hz Destruction: 0.75-mm single amplitude at 10 to 55 Hz Malfunction: 200 m/s 2, 3 times each in 6 directions Destruction: 300 m/s 2, 3 times each in 6 directions Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) (see note) (EMI) Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B (EMS) Immunity ESD: EN61000-4-2: 6 kv contact discharge (level 3) 8 kv air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kv power port and output port (level 3) 1 kv control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kv common mode (level 3) 1 kv differential mode (level 3) Light gray (5Y7/1) IP30 (IP20 for terminal block) Approx. 70 g For reference: A maximum current of 0.15 A can be switched at 125 VDC (cos φ = 1). A maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 ma at 5 VDC (failure level: P).

H3DS-F Nomenclature H3DS-F H3DS-FL H3DS-FLC ON-time display window ON-time scale display window and selector (select one from 0.1 s, 1 s, 0.1 m, 1 m, 0.1 h, and 1 h) OFF-time display window OFF-time scale display window and selector (select one from 0.1 s, 1 s, 0.1 m, 1 m, 0.1 h, and 1 h) Output ON/OFF indicator When the output is ON: Orange When the output is OFF: Green ON-time setting dial Lock for ON-time setting dial Lock for ON-time scale selector OFF-time setting dial Lock for OFF-time setting dial Lock for OFF-time scale selector Wire connection holes Release holes 18 16 A2 (Front View) (Front View) Wire connection holes Attach the enclosed label here as a nameplate. (The label is attached to the Timer's DIN Track hook section at the time of shipment.) Operation Block Diagram ON indicator (Orange) OFF indicator (Green) ON/OFF start selector AC (DC) input Indicator Time scale selector ROM RAM Clock Power supply One-chip microcomputer Output

H3DS-F H3DS-F I/O Function Inputs ON-start operation begins when inputs are turned ON. Outputs Control output Outputs are turned ON/OFF according to the time set by the ON-time and OFF-time setting dial. Basic Operation Selector Settings The selectors can be turned clockwise and counterclockwise to select the desired time scale or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position at which it is secured. Do not set it midway between two secure positions, or a malfunction could result from improper setting. Settings for ON-Start/OFF-Start If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the operating mode is switched to ON-start mode. If these terminals are disconnected, the mode switches to OFFstart mode. The operating mode will not change if the state of the applied voltage changes during timer operation. Selection of Time Scale The time scale is selected by turning the ON-time scale selector and OFF-time scale selector. The time scales will appear in the following order in each time scale display window on the left of the selector: 0.1 s, 1 h, 0.1 h, 1 m, 1 s, 0.1 h, 0.1 m, 1 s. The time scales 1 s and 0.1 h appear twice. Both instances indicate exactly the same time scale. Time Setting Use the ON-/OFF-time setting dials to set the ON-/OFF time. Locking/Unlocking Selectors and the Time Setting Dial The ON-/OFF-time setting dials and time scale selectors can be locked using the Y92S-38 Lock Key, a special pen type tool that is sold separately. To lock the dials or selectors, insert the Lock Key in the keyhole to the lower right of the dial or selector and turn it clockwise until the dial or selector is completely covered with the red cover. To unlock, turn the Lock Key in the opposite direction. Key hole ON-time scale display window and selector OFF-time scale display window and selector

H3DS-F H3DS-F Timing Charts Operating mode OFF-start (See note 1.) Timing chart Power (A 1 and A 2 ) ON OFF 0.1 s min. Output relay: NO 15 and 18 (ON indicator) Output relay: NC 15 and 16 OFF indicator ON OFF ON OFF ON OFF t ON : ON set time t OFF : OFF set time ON-start (See notes 1 and 3.) Power (A 1 and A 2 ) Signal (B 1 and A 2 ) ON OFF ON OFF 0.1 s min. Output relay: NO 15 and 18 (ON indicator) Output relay: NC 15 and 16 OFF indicator ON OFF ON OFF ON OFF t ON : ON set time t OFF : OFF set time 1. If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the operating mode is switched to ON-start mode. If these terminals are disconnected, the mode switches to OFF-start mode. 2. The reset time requires a minimum of 0.1 s. 3. When power is supplied in ON-start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer.

H3DS-F H3DS-F Dimensions Unit: mm (inch) H3DS-FL 17.5 Surface color: Light gray 5Y7/1 (OMRON) (0.69) 73 (2.87) 45 (1.77) 80 (3.15) 68 44 H3DS-FLC 17.5 Surface color: Light gray 5Y7/1 (OMRON) (0.69) 73 (2.87) 45 (1.77) 80 (3.15) 68 44 Accessories (Order Separately) Unit: mm (inch) Lock Key Y92S-38 100 (3.94) 6.4

H3DS-F H3DS-F Unit: mm (inch) Mounting Track PFP-100N, PFP-50N PFP-100N2 4.5 7.3±0.15 35±0.3 27±0.15 4.5 35±0.3 27 24 16 29.2 15 25 25 25 25 10 PFP-100N: 1 m PFP-50N: 0.5 m 10 1 PFP-100N: 15 mm PFP-50N: 5 mm 15 25 25 25 25 15 10 10 1 m 1 1.5 End Plate Spacer PFP-M 10 6.2 1.8 PFP-S 5 16 12 50 1 35.5 35.3 1.8 44.3 34.8 Installation 11.5 Terminal Arrangement 10 M4 x 8 pan head screw 1.3 4.8 16.5 H3DS-FLC A1 15 B1 H3DS-FL A1 15 B1 1. If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the operating mode is switched to ON-start mode. If these terminals are disconnected, the mode switches to OFF-start mode. 2. DC supply voltage does not require the designation of polarity. 15 15 L 18 16 18 16 18 16 A2 18 16 A2 (See note 2.)

H3DS-F H3DS-F Installation of Cage Clamp Terminal Models Tools A flat-blade screwdriver should be used to install the cables. Applicable Screwdriver Flat-blade, Parallel-tip, 2.5 mm diameter Flat-blade, Parallel-tip Use the following procedure 1. Insert the specified screwdriver into the release hole located beside the wire connection hole where the wire is to be inserted. Wire connection holes A 2.5 dia. Flat-blade, Flared-tip Release holes Fig. 2 Wire Connection Holes and Release Holes A Cannot be used. Examples:FACOM AEF.2.5 75E VESSEL No. 9900-(-)2.5 75 WAGO 210-119 WIHA 260/2.5 40 Applicable Wires Applicable Wire Sizes 0.2 to 1.5 mm 2, AWG24 to AWG16 Applicable Wire Type Solid wires, stranded wires, flexible wires, or wires with ferrules can be used. (See note 1) < 1.8 Diameter D (mm) 3.0 (see note 2) Conductor diameter d (mm) or length of sides a and b (mm) 1.6 Fig. 3 Section A-A of Fig. 2 Wire connection hole Release hole Screwdriver 2. Insert the exposed conductor into the wire connection hole. Insert Insert Wires with Ferrules 3. Pull out the screwdriver. Insert Pull out 1. If the overall diameter of the wire is less than 1.8 mm, do not insert the wire past the conductor. Refer to the following diagrams. 2. If the overall diameter of the wire is over 2.8 mm, it will be difficult to use double wiring. Wiring Precautions Always insert the screwdriver straight into the hole, never at an angle. The clamp spring may bend if the screwdriver is not straight. OK Wiring NG Use wires of the applicable sizes specified above. The length of the exposed conductor should be 6 to 7 mm. Fig. 1 Exposed Conductor Length Do not move the screwdriver side to side in the clamp hole. The clamp spring may bend if the screwdriver is moved sideways. 6 to 7 mm

H3DS-F H3DS-F Precautions Setting Changes!WARNING Do not change the time scale or operating mode while the Timer is in operation, or malfunction could result. Power Supplies The H3DS Series has a transformerless power supply system. Touching the input terminal while power is being supplied can cause you to get an electrical shock. Use the bar terminal for wiring the H3DS. Using a stranded-wire terminal may cause a short- due to a stray wire entering into the Timer. Both AC and DC power supplies can be connected to the power input terminals without regarding polarity. A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. Make sure that the voltage is applied within the specified range, or the internal elements of the Timer may be damaged. Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value at once or the Timer may not be reset or a timer error could result. Installation If the load current is continuously being supplied to the Timer for a long period of time, be sure to provide the mounting clearance as shown in the figure below. If used under conditions other than those specified below, the life of internal components may be shortened due to an excessive rise in the internal temperature. H3DS H3DS H3DS Precautions for EN61812-1 Conformance The H3DS as a built-in timer conforms to EN61812-1 provided that the following conditions are satisfied: The output section of the H3DS is provided only with basic isolation. To ensure reinforced isolation required by the EN61812-1, provide supplementary basic isolation on the load side connected to the output. The H3DS itself is designed according to the following: Overvoltage category III Pollution degree 2 On the above basis: Operation parts on the front and bottom: Reinforced isolation With clearance of 5.5 mm and creepage distance of 5.5 mm at 230 VAC Output: Basic isolation With clearance of 3 mm and creepage distance of 3 mm at 230 VAC Environment When using the Timer in an area with excess electrical noise, separate the Timer, wiring, and the equipment which generates the input signals as far as possible from the noise sources. Shield the input signal wiring to prevent electrical interference. Organic solvents (such as paint thinner), as well as very acidic or basic solutions, can damage the outer casing of the Timer. Do not use the Timer in places where it is exposed to dust, corrosive gas, or direct sunlight. When storing the Timer, make sure that the ambient temperature and humidity are within the rated values. Leave the Timer at room temperature for at least three hours before using the Timer if it has been stored at an ambient temperature of 10 C or below. Voltage Withstand Test t t DIN track If the Timer is mounted on a control board, remove the Timer from the control board or short- the ry of the power board before carrying out a voltage withstand test between the electrical ry and non-current-carrying metal part of the Timer, in order to prevent the internal ry of the Timer from damage. t: Mounting clearance (mm) Switching Current vs. Ambient Temperature (When Mounting Two or More H3DS Units Side-by-Side) H3DS-FL@ Mounting clearance: 50 mm min. Ambient temperature ( C) Mounting clearance: 10 mm Maximum range of operating ambient temperature Mounting clearance: 5 mm Mounting clearance: 0 mm Load current (A) (Measurement Condition: Input voltage of 230 VAC)

H3DS-F H3DS-F ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No. GC TMCN1 3/02 Specifications subject to change without notice Printed in USA

Star-Delta Timer H3DS-G 17.5 mm Star-Delta Timer Designed for Track Mounting A wide AC/DC power supply range, 24 to 230 VAC/24 to 48 VDC A wide star-time range up to 120 seconds, and delta-transfer time range up to 1 second Smart Dial/Selector-Locking Mechanism prevents the dials and selectors on the Timer s front panel from being operated without authorization. (The lock can only be unlocked and locked with an optional pen-type Lock key.) Finger-protection terminal block Ordering Information Description Supply voltage Part number Screw terminal type Cage clamp type Star-delta timer 24 to 230 VAC (50/60 Hz)/24 to 48 VDC H3DS-GL AC 24-230/DC 24-48 H3DS-GLC AC 24-230/DC 24-48 Model Number Legend H3DS -G L 1 2 3 1. G: Star-delta timer 2. L: Smart lock mechanism 3. None: Screw terminal type C: Cage clamp type Accessories (Order Separately) Description Part number Lock key Y92S-38 Mounting track 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End plate PFP-M Spacer PFP-S

H3DS-G Specifications General Item Operating mode Operating/Reset method External connections Terminal block Terminal screw tightening torque Output type Mounting method Attachment Approved standards H3DS-G H3DS-G Star-delta operation Time-limit operation/self-reset Screw terminal, cage clamp Screw terminal type: Clamps two 2.5-mm 2 max. bar terminals without sleeves. Cage clamp type: Clamps two 1.5-mm 2 max. bar terminals without sleeves. 0.98 N m max. (Star operation ) Relay: SPST-NO (Delta operation ) Relay: SPST-NO DIN track mounting (see note) Nameplate label UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kv/2, VDE0106/P100 Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/DC-13; 30 V 0.1 A) Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm. Time Ranges Time scale x 1 x 10 Star operation time ranges 1 to 12 s 10 to 120 s Transfer Time Star-delta transfer time Programmable at 0.05 s, 0.1 s, 0.5 s, or 1 s Ratings Rated supply voltage (see note) 24 to 230 VAC (50/60 Hz)/24 to 48 VDC Operating voltage range 85% to 110% of rated supply voltage Power reset Minimum power-off time: 0.5 s Reset voltage 2.4 VAC/DC max. Power consumption AC: 21 VA max./1.7 W max. (typical: 20 VA/1.6 W) at 230 VAC; 11 VA max./2.0 W max. (typical: 8.6 VA/1.5 W) at 100 to 120 VAC DC: 1.3 W max. (typical: 1.2 W) at 24 VDC; 0.7 W max. (typical: 0.6 W) at 48 VDC Control output Contact output:5 A at 250 VAC with resistive load (cos φ = 1) 5 A at 30 VDC with resistive load (cos φ = 1) Ambient temperature Operating: 10 C to 55 C (14 F to1315 F) with no icing Storage: 25 C to 65 C ( 13 F to 145 F) with no icing Ambient humidity Operating: 35% to 85% DC ripple rate: 20% max.

H3DS-G H3DS-G Characteristics Accuracy of operating time Setting error Total tolerance of transfer time Influence of voltage Influence of temperature Insulation resistance Dielectric strength ±1% max. of FS ±10% ± 50 ms max. of FS ± (25% FS + 5 ms) max. ±0.5% max. of FS ±2% max. of FS 100 MΩ min. at 500 VDC Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1 min. Between control output terminals and operating : 2,000 VAC (50/60 Hz) for 1 min. Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min. Impulse withstand voltage 3 kv (between power supply terminals) 4.5 kv (between current-carrying metal parts and exposed non-current-carrying metal parts) Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±1.5 kv Static immunity Malfunction: 4 kv Destruction: 8 kv Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz Destruction: 0.75-mm single amplitude at 10 to 55 Hz Shock resistance Life expectancy EMC Case color Degree of protection Weight Malfunction: 200 m/s 2, 3 times each in 6 directions Destruction: 300 m/s 2, 3 times each in 6 directions Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) (see note) (EMI) Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B (EMS) Immunity ESD: EN61000-4-2:6 kv contact discharge (level 3) 8 kv air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kv power port and output port (level 3) 1 kv control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kv common mode (level 3) 1 kv differential mode (level 3) Light gray (5Y7/1) IP30 (IP20 for terminal block) Approx. 70 g For reference: A maximum current of 0.15 A can be switched at 125 VDC (cos φ = 1). A maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 ma at 5 VDC (failure level: P).

H3DS-G Nomenclature H3DS-G H3DS-GL H3DS-GLC Wire connection holes Delta operation indicator (orange) Set time window Star-delta transfer time and star operation time scale display window and selector Time setting dial (for setting star operation time) Lock for time setting dial Lock for star-delta transfer time and star operation time scale Release holes Star operation indicator (green) 18 28 A2 (Front View) (Front View) Wire connection holes Attach the enclosed label here as a nameplate. (The label is attached to the Timer's DIN Track hook section at the time of shipment.) Operation Block Diagram AC (DC) input Star operation time scale selector Star-delta transfer time selection Power supply Star operation time oscillation Star operation time counting Star-delta transfer time oscillation Star-delta transfer time counting Output Star operation Delta operation Indicator Star operation indicator Delta operation indicator

H3DS-G H3DS-G I/O Functions Inputs --- Outputs Control output Star output is turned OFF when the dial set value is reached and delta output is ON after the preset transfer time elapses Basic Operation Setting of Selector The selectors can be turned clockwise and counterclockwise to select the desired time scale, or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position at which it is secured. Do not set it midway between two securing positions or a malfunction could result from improper setting. Selection of Time Unit and Time Scale The star-delta transfer time and star operation time scale are set with the same selector. The star-delta transfer time can be set to 0.05, 0.1, 0.5, or 1. The star operation time scale can be set to a multiplication factor of 1 or 10. If the star-delta transfer time is displayed in the display window in white letters, this means that the star operation time scale is x10. Refer to the example below. Time Setting The star operation time of the Timer is set with the time setting dial. Locking/Unlocking of Selectors and Time Setting Dial The time setting dial and time scale selector can be locked using the Y92S-38 Lock Key, a special pen type tool that is sold separately. To lock the dial or selectors, insert the Lock Key in the keyhole to the lower right of the dial or selector and turn it clockwise until the dial or selector is completely covered with the red cover. To unlock, turn the Lock Key in the opposite direction. Star-delta transfer time 0.05 s 0.1 s 0.5 s Star operation time scale x1 1 s Key hole 0.05 s 0.1 s 0.5 s x10 1 s Star-delta transfer time and star operation time scale display window and selector Timing Charts Power (A 1 and A 2 ) ON OFF 0.5 s Star contact 17 and 18 (star indicator) ON OFF t 1 t 2 Delta contact 27 and 28 (delta indicator) ON OFF t 1 : Star operation time setting t 2 : Star-delta transfer time The reset time requires a maximum of 0.5 s.

H3DS-G Dimensions H3DS-G Unit: mm (inch) H3DS-GL 17.5 Surface color: Light gray 5Y7/1 (OMRON) (0.69) 73 (2.87) 45 (1.77) 80 (3.15) 68 44 H3DS-GLC 17.5 Surface color: Light gray 5Y7/1 (OMRON) (0.69) 73 (2.87) 45 (1.77) 80 (3.15) 68 44 Accessories (Order Separately) Lock Key Y92S-38 100 (3.94) 6.4

H3DS-G H3DS-G Unit: mm (inch) Mounting Track PFP-100N, PFP-50N PFP-100N2 4.5 7.3±0.15 35±0.3 27±0.15 4.5 35±0.3 27 24 16 29.2 15 25 25 25 25 10 PFP-100N: 1 m PFP-50N: 0.5 m 10 1 PFP-100N: 15 mm PFP-50N: 5 mm 15 25 25 25 25 15 10 10 1 m 1 1.5 End Plate Spacer PFP-M 10 6.2 1.8 PFP-S 5 16 12 50 1 35.5 35.3 1.8 44.3 34.8 Installation 11.5 Terminal Arrangement 10 M4 x 8 pan head screw 1.3 4.8 16.5 H3DS-GLC H3DS-GL DC supply voltage does not require the designation of polarity. A1 17 27 A1 17 27 17 27 17 27 18 28 18 28 18 28 A2

H3DS-G Installation of Cage Clamp Terminal Models Tools A flat-blade screwdriver should be used to install the cables. Applicable Screwdriver Flat-blade, Parallel-tip, 2.5 mm diameter H3DS-G Use the following procedure 1. Insert the specified screwdriver into the release hole locate beside the wire connection hole where the wire is to be inserted. A Flat-blade, Parallel-tip Wire connection holes 2.5 dia. Flat-blade, Flared-tip Cannot be used. Examples:FACOM AEF.2.5 75E VESSEL No. 9900-(-)2.5 75 WAGO 210-119 WIHA 260/2.5 40 Applicable Wires Applicable Wire Sizes 0.2 to 1.5 mm 2, AWG24 to AWG16 Applicable Wire Type Solid wires, stranded wires, flexible wires, or wires with ferrules can be used. (See note 1) < 1.8 Diameter D (mm) 3.0 (see note 2) Conductor diameter d (mm) or length of sides a and b (mm) 1.6 Release holes Fig. 2 Wire Connection Holes and Release Holes Fig. 3 Section A-A of Fig. 2 Wire connection hole Release hole Screwdriver 2. Insert the exposed conductor into the wire connection hole. A Insert Insert Wires with Ferrules 3. Pull out the screwdriver. Insert Pull out 1. If the overall diameter of the wire is less than 1.8 mm, do not insert the wire past the conductor. Refer to the following diagrams. 2. If the overall diameter of the wire is over 2.8 mm, it will be difficult to use double wiring. Wiring Precautions Always insert the screwdriver straight into the hole, never at an angle. The clamp spring may bend if the screwdriver is not straight. OK NG Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 6 to 7 mm. Fig. 1 Exposed Conductor Length Do not move the screwdriver side to side in the clamp hole. The clamp spring may bend if the screwdriver is moved sideways. 6 to 7 mm

H3DS-G Precautions Setting Changes!WARNING Do not change the time scale or operating mode while the Timer is in operation, or malfunction could result. Power Supplies The H3DS Series has a transformerless power supply system. Touching the input terminal while power is being supplied can cause you to get an electrical shock. Use the bar terminal for wiring the H3DS. Using a stranded-wire terminal may cause a short- due to a stray wire entering into the Timer. Both AC and DC power supplies can be connected to the power input terminals without regarding polarity. With the H3DS only, a DC power supply must be connected to the power input terminals as designated according to the polarity of the terminals. A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. Make sure that the voltage is applied within the specified range, or the internal elements of the Timer may be damaged. Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value at once or the Timer may not be reset or a timer error could result. Installation If the load current is continuously being supplied to the Timer for a long period of time, be sure to provide the mounting clearance as shown in the figure below. If used under conditions other than those specified below, the life of internal components may be shortened due to an excessive rise in the internal temperature. H3DS H3DS H3DS t t DIN track Precautions for EN61812-1 Conformance H3DS-G The H3DS as a built-in timer conforms to EN61812-1 provided that the following conditions are satisfied: The output section of the H3DS is provided only with basic isolation. To ensure reinforced isolation required by the EN61812-1, provide supplementary basic isolation on the load side connected to the output. The H3DS itself is designed according to the following: Overvoltage category III Pollution degree 2 On the above basis: Operation parts on the front and bottom: Reinforced isolation With clearance of 5.5 mm and creepage distance of 5.5 mm at 230 VAC Output: Basic isolation With clearance of 3 mm and creepage distance of 3 mm at 230 VAC Environment When using the Timer in an area with excess electrical noise, separate the Timer, wiring, and the equipment which generates the input signals as far as possible from the noise sources. Shield the input signal wiring to prevent electrical interference. Organic solvents (such as paint thinner), as well as very acidic or basic solutions, can damage the outer casing of the Timer. Do not use the Timer in places where it is exposed to dust, corrosive gas, or direct sunlight. When storing the Timer, make sure that the ambient temperature and humidity are within the rated values. Leave the Timer at room temperature for at least three hours before using the Timer if it has been stored at an ambient temperature of 10 C or below. Voltage Withstand Test If the Timer is mounted on a control board, remove the Timer from the control board or short- the ry of the power board before carrying out a voltage withstand test between the electrical ry and non-current-carrying metal part of the Timer, in order to prevent the internal ry of the Timer from damage. t: Mounting clearance (mm) Switching Current vs. Ambient Temperature (When Mounting Two or More H3DS Units Side-by-Side) H3DS-GL@ Mounting clearance: 50 mm min. Ambient temperature ( C) Mounting clearance: 10 mm Maximum range of operating ambient temperature Mounting clearance: 5 mm Mounting clearance: 0 mm Load current (A) (Measurement Condition: Input voltage of 230 VAC)

H3DS-G H3DS-G ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No.GC TMCN1 3/02 Specifications subject to change without notice Printed in USA

Solid-State Two-Wired Timer H3DS-X 17.5 mm Two-Wired Timer Designed for Track Mounting Wide AC/DC power supply range (24-230 VAC/VDC) Smart Dial/Selector-Locking Mechanism prevents the dials and selectors on the Timer s front panel from being operated without authorization. (The lock can only be unlocked and locked with an optional pen-type Lock key.) Time range of 0.1 second to 120 hours Finger-protection terminal block Ordering Information Description Supply voltage Part number Screw terminal type Cage clamp type ON-delay 24 to 230 VAC/VDC (50/60 Hz) H3DS-XL AC/DC 24-230 H3DS-XLC AC/DC 24-230 Model Number Legend H3DS -X L 1 2 3 1. X: Two-wired timer 2. L: Smart lock mechanism 3. None: Screw terminal type C: Cage clamp type Accessories (Order Separately) Description Part number Lock key Y92S-38 Mounting track 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End plate PFP-M Spacer PFP-S

H3DS-X Specifications General H3DS-X Item Operating mode Operating/Reset method Output type External connections Terminal block Terminal screw tightening torque Output type Mounting method Attachment Approved standards H3DS-X ON-delay Time-limit operation/self-resetting SCR output Screw terminal, cage clamp Screw terminal type: Clamps two 2.5-mm 2 max. bar terminals without sleeves. Cage clamp type: Clamps two 1.5-mm 2 max. bar terminals without sleeves. 0.98 N m max. (Star operation ) Relay: SPST-NO (Delta operation ) Relay: SPST-NO DIN track mounting (see note) Nameplate label UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kv/2, VDE0106/P100 Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm. Time Ranges Time scale Star operation time ranges 0.1 s 0.1 to 1.2 s 1 s 1 to 12 s 0.1 m 0.1 to 1.2 min 1 m 1 to 12 min 0.1 h 0.1 to 1.2 h 1 h 1 to 12 h 10 h 10 to 120 h When the time setting dial is set to 0 for any time scale, the output will operate instantaneously. Ratings Rated supply voltage (see note) 24 to 230 VAC/VDC (50/60 Hz) Operating voltage range 85% to 110% of rated supply voltage Power reset Minimum power-off time: 0.1 s Reset voltage 1.0 VAC/VDC max. Reset current 5 ma max. Power consumption 5 ma max. Control output SCR output: 5 ma to 0.7A Ambient temperature Operating: 10 C to 55 C (14 F to131 F) with no icing Storage: 25 C to 65 C ( 13 F to 145 F) with no icing Ambient humidity Operating: 35% to 85% DC ripple rate: 20% max.

H3DS-X H3DS-X Characteristics Accuracy of operating time Setting error Reset time Influence of voltage Influence of temperature Insulation resistance Dielectric strength ±1% max. of FS (±1% ±10 ms max. at 1.2 s range) ±10% ±50 ms max. of FS 0.1 s max. ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2 s range) ±2% max. of FS (±2% ±10 ms max. at 1.2 s range) 100 MΩ min. at 500 VDC Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min. Impulse withstand voltage 3 kv (between power supply terminals) 4.5 kv (between current-carrying metal parts and exposed non-current-carrying metal parts) Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±1.5 kv (between power supply terminals) Static immunity Malfunction: 4 kv Destruction: 8 kv Vibration resistance Malfunction: 0.5 mm single amplitude at 10 to 55 Hz Destruction: 0.75 mm single amplitude at 10 to 55 Hz Shock resistance Malfunction: 200 m/s 2, 3 times each in 6 directions Destruction: 300 m/s 2, 3 times each in 6 directions EMC (EMI) Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B (EMS) Immunity ESD: EN61000-4-2: 6 kv contact discharge (level 3) 8 kv air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kv power port and output port (level 3) 1 kv control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kv common mode (level 3) 1 kv differential mode (level 3) Case color Degree of protection Weight Light gray (5Y7/1) IP30 (IP20 for terminal block) Approx. 70 g

H3DS-X Nomenclature H3DS-X H3DS-XL H3DS-XLC Wire connection holes Set time window Time scale display window and selector (select one from 1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, and 0.1 m) Time setting dial (set time) Lock for time setting dial Lock for time scale selector Release holes H3DS-XL A2 Power-ON indicator (green) (Lit while the power is ON.) A2 Wire connection holes (Front View) (Front View) Attach the enclosed label here as a nameplate. (The label is attached to the Timer's DIN Track hook section at the time of shipment.) Operation Block Diagram Zero setting detection Time scale/ unit selectors Indicator AC (DC) input Power supply Oscillation Counting Output

H3DS-X H3DS-X I/O Functions Inputs --- Outputs Control output Outputs are turned On when the preset value is reached. Basic Operation Selector Settings The selectors can be turned clockwise and counterclockwise to select the desired time scale or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position where it is secured. Do not set it midway between two secure positions, or a malfunction could result from improper setting. Selection of Time Scale To select the time scale, turn the time scale selector, and the time scales will appear (in the time scale display window on the left of the selector) in the order shown here: 1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, 0.1 m. The time scale 1h appears twice. Both instances indicate exactly the same time Locking/Unlocking Selectors and the Time Setting Dial The time setting dial and time scale selector can be locked using the Y92S-38 Lock Key, a special pen type tool that is sold separately. To lock the dial or selectors, insert the Lock Key in the keyhole to the lower right of the dial or selector and turn it clockwise until the dial or selector is completely covered with the red cover. To unlock, turn the Lock Key in the opposite direction. Key hole Time scale display window and selector Timing Charts Rt 0.1 s min. Power (A1 and A2) Output ON Indicator OFF Set time Rt: Resetting time

H3DS-X Dimensions H3DS-X Unit: mm (inch) H3DS-XL 17.5 (0.69) 73 (2.87) Surface color: Light gray 5Y7/1 (OMRON) 45 (1.77) 80 (3.15) H3DS-XLC 17.5 (0.69) 73 (2.87) 73 45 (1.77) 80 80 (3.15) 68 44 Accessories (Order Separately) Lock Key Y92S-38 100 (3.94) 6.4

H3DS-X H3DS-X Unit: mm (inch) Mounting Track PFP-100N, PFP-50N PFP-100N2 4.5 7.3±0.15 35±0.3 27±0.15 4.5 35±0.3 27 24 16 29.2 15 25 25 25 25 10 PFP-100N: 1 m PFP-50N: 0.5 m 10 1 PFP-100N: 15 mm PFP-50N: 5 mm 15 25 25 25 25 15 10 10 1 m 1 1.5 End Plate Spacer PFP-M 10 6.2 1.8 PFP-S 5 16 12 50 1 35.5 35.3 1.8 44.3 34.8 Installation 11.5 Terminal Arrangement 10 M4 x 8 pan head screw 1.3 4.8 16.5 H3DS-XLC H3DS-XL DC supply voltage does not require the designation of polarity. A1 A1 A2 A2

H3DS-X Installation of Cage Clamp Terminal Models Tools A flat-blade screwdriver should be used to install the cables. Applicable Screwdriver Flat-blade, Parallel-tip, 2.5 mm diameter H3DS-X Use the following procedure 1. Insert the specified screwdriver into the release hole locate beside the wire connection hole where the wire is to be inserted. A Flat-blade, Parallel-tip Wire connection holes 2.5 dia. Flat-blade, Flared-tip Cannot be used. Examples:FACOM AEF.2.5 75E VESSEL No. 9900-(-)2.5 75 WAGO 210-119 WIHA 260/2.5 40 Applicable Wires Applicable Wire Sizes 0.2 to 1.5 mm 2, AWG24 to AWG16 Applicable Wire Type Solid wires, stranded wires, flexible wires, or wires with ferrules can be used. (See note 1) < 1.8 Diameter D (mm) 3.0 (see note 2) Conductor diameter d (mm) or length of sides a and b (mm) 1.6 Release holes Fig. 2 Wire Connection Holes and Release Holes Fig. 3 Section A-A of Fig. 2 Wire connection hole Release hole Screwdriver 2. Insert the exposed conductor into the wire connection hole. A Insert Insert Wires with Ferrules 3. Pull out the screwdriver. Insert Pull out 1. If the overall diameter of the wire is less than 1.8 mm, do not insert the wire past the conductor. Refer to the following diagrams. 2. If the overall diameter of the wire is over 2.8 mm, it will be difficult to use double wiring. Wiring Precautions Always insert the screwdriver straight into the hole, never at an angle. The clamp spring may bend if the screwdriver is not straight. OK NG Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 6 to 7 mm. Fig. 1 Exposed Conductor Length Do not move the screwdriver side to side in the clamp hole. The clamp spring may bend if the screwdriver is moved sideways. 6 to 7 mm

H3DS-X Precautions Setting Changes!WARNING Do not change the time scale or operating mode while the Timer is in operation, or malfunction could result. Power Supplies The H3DS Series has a transformerless power supply system. Touching the input terminal while power is being supplied can cause you to get an electrical shock. Use the bar terminal for wiring the H3DS. Using a stranded-wire terminal may cause a short- due to a stray wire entering into the Timer. Both AC and DC power supplies can be connected to the power input terminals without regard to polarity. A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. Make sure that the voltage is applied within the specified range, or the internal elements of the Timer may be damaged. Connect the power supply voltage through a relay or switch in a way so that the voltage reaches a fixed value at once. If this is not done, the Timer may not be reset, or a timer error could result. Installation Several H3DS-XL@ Timers can be mounted together side by side. H3DS H3DS H3DS t t t: Mounting clearance (mm) DIN track Precautions for EN61812-1 Conformance H3DS-X The following conditions must be met so that the built-in timer in the H3DS conforms to EN61812-1: The output section of the H3DS is provided with basic isolation only. To ensure reinforced isolation required by the EN61812-1, provide supplementary basic isolation on the load side connected to the output. The H3DS itself is designed according to the following: Overvoltage category III Pollution degree 2 On the above basis: Operation parts on the front and bottom: reinforce isolation With clearance of 5.5 mm and creepage distance of 5.5 mm at 230 VAC Output: Basic isolation With clearance of 3 mm and creepage distance of 3 mm at 230 VAC Environment When using the Timer in an area with excess electrical noise, separate the Timer, wiring, and the equipment which generates the input signals as far as possible from the noise sources. Shield the input signal wiring to prevent electrical interference. Organic solvents (such as paint thinner), as well as very acidic or basic solutions, can damage the outer casing of the Timer. Do not use the Timer in places where it is exposed to dust, corrosive gas, or direct sunlight. When storing the Timer, make sure that the ambient temperature and humidity are within the rated values. If the timer has been stored at an ambient temperature of 10 C or below, leave the Timer at room temperature for at least three hours before using the Timer. Voltage Withstand Test Before carrying out a voltage withstand test between the electrical ry and non-current-carrying metal part of the Timer, remove the Timer from the control board (if it s mounted there) or short- the ry of the power board. This prevents the internal ry of the Timer from damage.

H3DS-X H3DS-X ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No. L098X-E3-1 11/01 Specifications subject to change without notice Printed in USA

Solid-State Two-Wired Timer H3DS-X 17.5 mm Two-Wired Timer Designed for Track Mounting Wide AC/DC power supply range (24-230 VAC/VDC) Smart Dial/Selector-Locking Mechanism prevents the dials and selectors on the Timer s front panel from being operated without authorization. (The lock can only be unlocked and locked with an optional pen-type Lock key.) Time range of 0.1 second to 120 hours Finger-protection terminal block Ordering Information Description Supply voltage Part number Screw terminal type Cage clamp type ON-delay 24 to 230 VAC/VDC (50/60 Hz) H3DS-XL AC/DC 24-230 H3DS-XLC AC/DC 24-230 Model Number Legend H3DS -X L 1 2 3 1. X: Two-wired timer 2. L: Smart lock mechanism 3. None: Screw terminal type C: Cage clamp type Accessories (Order Separately) Description Part number Lock key Y92S-38 Mounting track 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End plate PFP-M Spacer PFP-S

H3DS-X Specifications General H3DS-X Item Operating mode Operating/Reset method Output type External connections Terminal block Terminal screw tightening torque Output type Mounting method Attachment Approved standards H3DS-X ON-delay Time-limit operation/self-resetting SCR output Screw terminal, cage clamp Screw terminal type: Clamps two 2.5-mm 2 max. bar terminals without sleeves. Cage clamp type: Clamps two 1.5-mm 2 max. bar terminals without sleeves. 0.98 N m max. (Star operation ) Relay: SPST-NO (Delta operation ) Relay: SPST-NO DIN track mounting (see note) Nameplate label UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kv/2, VDE0106/P100 Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm. Time Ranges Time scale Star operation time ranges 0.1 s 0.1 to 1.2 s 1 s 1 to 12 s 0.1 m 0.1 to 1.2 min 1 m 1 to 12 min 0.1 h 0.1 to 1.2 h 1 h 1 to 12 h 10 h 10 to 120 h When the time setting dial is set to 0 for any time scale, the output will operate instantaneously. Ratings Rated supply voltage (see note) 24 to 230 VAC/VDC (50/60 Hz) Operating voltage range 85% to 110% of rated supply voltage Power reset Minimum power-off time: 0.1 s Reset voltage 1.0 VAC/VDC max. Reset current 5 ma max. Power consumption 5 ma max. Control output SCR output: 5 ma to 0.7A Ambient temperature Operating: 10 C to 55 C (14 F to131 F) with no icing Storage: 25 C to 65 C ( 13 F to 145 F) with no icing Ambient humidity Operating: 35% to 85% DC ripple rate: 20% max. 2

H3DS-X H3DS-X Characteristics Accuracy of operating time Setting error Reset time Influence of voltage Influence of temperature Insulation resistance Dielectric strength ±1% max. of FS (±1% ±10 ms max. at 1.2 s range) ±10% ±50 ms max. of FS 0.1 s max. ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2 s range) ±2% max. of FS (±2% ±10 ms max. at 1.2 s range) 100 MΩ min. at 500 VDC Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min. Impulse withstand voltage 3 kv (between power supply terminals) 4.5 kv (between current-carrying metal parts and exposed non-current-carrying metal parts) Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±1.5 kv (between power supply terminals) Static immunity Malfunction: 4 kv Destruction: 8 kv Vibration resistance Malfunction: 0.5 mm single amplitude at 10 to 55 Hz Destruction: 0.75 mm single amplitude at 10 to 55 Hz Shock resistance EMC Case color Degree of protection Weight Malfunction: 200 m/s 2, 3 times each in 6 directions Destruction: 300 m/s 2, 3 times each in 6 directions (EMI) Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B (EMS) Immunity ESD: EN61000-4-2: 6 kv contact discharge (level 3) 8 kv air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kv power port and output port (level 3) 1 kv control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kv common mode (level 3) 1 kv differential mode (level 3) Light gray (5Y7/1) IP30 (IP20 for terminal block) Approx. 70 g 3

H3DS-X Nomenclature H3DS-X H3DS-XL H3DS-XLC Wire connection holes Set time window Time scale display window and selector (select one from 1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, and 0.1 m) Time setting dial (set time) Lock for time setting dial Lock for time scale selector Release holes H3DS-XL A2 Power-ON indicator (green) (Lit while the power is ON.) A2 Wire connection holes (Front View) (Front View) Attach the enclosed label here as a nameplate. (The label is attached to the Timer's DIN Track hook section at the time of shipment.) Operation Block Diagram Zero setting detection Time scale/ unit selectors Indicator AC (DC) input Power supply Oscillation Counting Output 4

H3DS-X H3DS-X I/O Functions Inputs --- Outputs Control output Outputs are turned On when the preset value is reached. Basic Operation Selector Settings The selectors can be turned clockwise and counterclockwise to select the desired time scale or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position where it is secured. Do not set it midway between two secure positions, or a malfunction could result from improper setting. Selection of Time Scale To select the time scale, turn the time scale selector, and the time scales will appear (in the time scale display window on the left of the selector) in the order shown here: 1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, 0.1 m. The time scale 1h appears twice. Both instances indicate exactly the same time Locking/Unlocking Selectors and the Time Setting Dial The time setting dial and time scale selector can be locked using the Y92S-38 Lock Key, a special pen type tool that is sold separately. To lock the dial or selectors, insert the Lock Key in the keyhole to the lower right of the dial or selector and turn it clockwise until the dial or selector is completely covered with the red cover. To unlock, turn the Lock Key in the opposite direction. Key hole Time scale display window and selector Timing Charts Rt 0.1 s min. Power (A1 and A2) Output ON Indicator OFF Set time Rt: Resetting time 5

H3DS-X Dimensions H3DS-X Unit: mm (inch) H3DS-XL 17.5 (0.69) 73 (2.87) Surface color: Light gray 5Y7/1 (OMRON) 45 (1.77) 80 (3.15) H3DS-XLC 17.5 (0.69) 73 (2.87) 73 45 (1.77) 80 80 (3.15) 68 44 Accessories (Order Separately) Lock Key Y92S-38 100 (3.94) 6.4 6

H3DS-X H3DS-X Unit: mm (inch) Mounting Track PFP-100N, PFP-50N PFP-100N2 4.5 7.3±0.15 35±0.3 27±0.15 4.5 35±0.3 27 24 16 29.2 15 25 25 25 25 10 PFP-100N: 1 m PFP-50N: 0.5 m 10 PFP-100N: 15 mm PFP-50N: 5 mm 1 15 25 25 25 25 15 10 10 1 m 1 1.5 End Plate Spacer PFP-M 10 6.2 1.8 PFP-S 5 16 12 50 1 35.5 35.3 1.8 44.3 34.8 Installation 11.5 Terminal Arrangement 10 M4 x 8 pan head screw 1.3 4.8 16.5 H3DS-XLC H3DS-XL DC supply voltage does not require the designation of polarity. A1 A1 A2 A2 7

H3DS-X Installation of Cage Clamp Terminal Models Tools A flat-blade screwdriver should be used to install the cables. Applicable Screwdriver Flat-blade, Parallel-tip, 2.5 mm diameter H3DS-X Use the following procedure 1. Insert the specified screwdriver into the release hole locate beside the wire connection hole where the wire is to be inserted. A Flat-blade, Parallel-tip Wire connection holes 2.5 dia. Flat-blade, Flared-tip Cannot be used. Examples:FACOM AEF.2.5 75E VESSEL No. 9900-(-)2.5 75 WAGO 210-119 WIHA 260/2.5 40 Applicable Wires Applicable Wire Sizes 0.2 to 1.5 mm 2, AWG24 to AWG16 Applicable Wire Type Solid wires, stranded wires, flexible wires, or wires with ferrules can be used. (See note 1) < 1.8 Diameter D (mm) 3.0 (see note 2) Conductor diameter d (mm) or length of sides a and b (mm) 1.6 Release holes Fig. 2 Wire Connection Holes and Release Holes Fig. 3 Section A-A of Fig. 2 Wire connection hole Release hole Screwdriver 2. Insert the exposed conductor into the wire connection hole. A Insert Insert Wires with Ferrules 3. Pull out the screwdriver. Insert Pull out 1. If the overall diameter of the wire is less than 1.8 mm, do not insert the wire past the conductor. Refer to the following diagrams. 2. If the overall diameter of the wire is over 2.8 mm, it will be difficult to use double wiring. Wiring Precautions Always insert the screwdriver straight into the hole, never at an angle. The clamp spring may bend if the screwdriver is not straight. OK NG Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 6 to 7 mm. Fig. 1 Exposed Conductor Length Do not move the screwdriver side to side in the clamp hole. The clamp spring may bend if the screwdriver is moved sideways. 6 to 7 mm 8