POB series Coil Tester & Power Supply Units

Similar documents
POB series Coil Tester & Power Supply Units

Handheld Micro Ohmmeters RMO-H series

Handheld Micro Ohmmeters RMO-H series

BLU SERIES Battery Load Units

BLU SERIES Battery Load Units

BLU SERIES Battery Load Units

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

MJÖLNER 200 Microhmmeter

DLRO-H200 Microhmmeter

MOM2 Micro-ohmmeter APPLICATIONS DESCRIPTION. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround

MOM2 Microhmmeter. MOM2 Microhmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Close-Open (Short-Circuit) Time Results Interpretation

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Technical Information Liquiline System CAT810

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Bulletin 190-M Compact Starters. Selection Guide

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Differential Pressure Sensors

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Essential equipment for all your requirements

MS General Information Extended Product Type: MS

MOM2 Handheld High Current Micro-ohmmeter

Technical Information

Thermal Overcurrent Circuit Breaker 3120-F...

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

User's Manual. Earth Ground Resistance Tester. Model Introduction

Safety switches for hinged doors

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TECHNICAL DESCRIPTION

Miniaturized limit switches

Advanced Test Equipment Rentals ATEC (2832)

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

SIRIUS 3RU2 Thermal Overload Relays

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Thermal Overcurrent Circuit Breaker 3120-F...

Metasys Zoning Package

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors

Electronic circuit breaker EBU10-T

Ground Resistance Tester Model 3620 & 3620 Kits

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

AF40... AF96 3-pole contactors Technical data

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Advanced Test Equipment Rentals ATEC (2832)

Installation and Operating Instructions

Switching Power Supply

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Electronic overload relays EF205 and EF370

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Electronic overload relay EF65, EF96 and EF146

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

max pole for t=15 ms

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Cylindrical fuse-link

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Thermal Overcurrent Circuit Breaker 3120-F...

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Basic Series Accessories Low Voltage Current Transformer Class 1

Industrial Contactors CTX 3 3P 185A - 800A

Ex m Solenoid Operator Type 0519

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Thermal-magnetic Miniature Circuit Breaker 4230-T...

AF series contactors (9 2650)

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

LED Driver Linear / area dimming

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Differential pressure sensor

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Safety technique. Emergency Stop Module BH 5928, BI 5928

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Electromotoric Actuators

General_technical_data Series

Modular contactors and relays

D509E. Manual Motor - Starters

Application Mini Contactors for Motors and Resistive Loads

Series KTU7 UL489 Molded Case Circuit Breakers

Transcription:

POB series Coil Tester Power Supply Units Lightweight - only 10,60 kg Powerful up to 40 A 10 V to 300 V DC 10 V to 250 V AC Minimum Trip test Output protection Fully automatic operation Powerful DC and AC power supply for a circuit breaker test The Coil Tester Power Supply POB series is a powerful tool for testing circuit breakers, where the substation battery is not connected or available. It operates the circuit breaker coils and spring charging motors as a part of commissioning and maintenance testing. The POB series generates true DC (ripple free) or AC voltage and can also be used to test a minimum trip voltage of the circuit breaker coils. The output voltage is selectable from 10 V to 300 V DC or from 10 V to 250 V AC. POB device series are powerful and a versatile units which, at mains supply, are capable of generating on its Motor output the initial current of 40 A as well as the continuous DC currents as presented in Duty cycle table below. The set is equipped with thermal and overcurrent protection. The POB series is easy to use and has the accessory cable-set with touchproof contacts. Thanks to a proprietary hardware and software solution, it is capable of canceling electrostatic and electromagnetic interference in HV electric fields. 1

Motor Output DC Model Mains Load Max Current Max load interval Model Mains Load Max Current Max load interval 20 A 30 A 1 1 6 A POB30D 48 V DC 20 A POB40D POB40AD 48 V DC 30 A 1 120 V 125 V DC 10,6 A 8,9 A 3, contin 120 V 115 V DC 13,2 A 10, 6 A 6 A Coil Outputs DC POB30D 0-300 V DC 6 A POB40D POB40AD 0-300 V DC 7, Coil Outputs AC 0-250 V AC 6 A POB40AD 0-250 V AC 1 Duty cycles POB device series 2

Application The POB series is used in switchyards, power and industrial environment, in manufacturing, in commissioning and as well in maintenance of the circuit breakers for: operating circuit breakers supplying spring-charging motors power supply at test with breaker analyzers minimum trip voltage-test of the circuit breaker s coils The POB series has a built-in capability to perform automatic test of minimum trip voltage. The minimum trip voltage test is described in a number of international and national standards such as IEC 62271-100, ANSI C37.09 etc. Performing tests and acquiring of many other important parameters are possible with circuit breaker analyzers. The POB series is then used as a power supply unit. It is compatible with breaker analyzers from different vendors. The POB series can also be used as a general power supply unit or temporary battery charger. Automatic testing of the Minimum Trip of a breaker Procedure steps: 1. The circuit breaker mains terminals have to be de-energized and safety grounded on both sides and the auxiliary (control) circuit as well. The local safety regulations should be followed. 2. Connect the Power supply unit POB series to the breaker's coil circuit. 3. Set the minimum test voltage. Figure 1. Setting up MTV test 4. Set the step voltage. 5. Set the maximum voltage. 6. Press the TRIG key 3

Connecting the POB series to a test object Technical Data Mains Power Supply Connection according to IEC/EN60320-1; UL498, CSA 22.2 90 V 264 V AC, 50/60 Hz, Single phase Power consumption 4000 VA Output data Coils output DC 10 V to 300 V DC (varies for different device models) Coils output AC 10 V to 250 V AC (varies for different device models); 50/60 Hz; true RMS Motor output DC 10 V to 250 V DC Output current max 40 A (varies for different device models) Measurement 10 V 300 V DC or 10 V 250 V AC Current 1 A 50 A Accuracy ± (0,25% rdg + 0,25% FS) Humidity Maximum relative humidity 95%, noncondensing Dimensions and Weight Dimensions (W x H x D) without handle 205 mm x 287 mm x 410 mm 8,1 in x 11,3 in x 16,14 in Weight 10,60 kg / 23.37 lbs Mechanical protection IP 43 Warranty Three years Safety Standards Low Directive: Directive 2014/35/EU (CE conform). Applicable standards, for a class I instrument, pollution degree 2, Installation category II: IEC EN 61010-1 Environment conditions Operating temperature 10 o C - +55 o C / 14 F 131 F Storage and transportation 40 o C - +70 o C / -40 F 158 F All specifications herein are valid at ambient temperature of + 25 C and recommended accessories. Specifications are subject to change without notice. 4

Accessories Transport case Cable set External Trigger cable POB series models Generates 10 V to 300 V DC and 10 V to 250 V AC on coils outputs. Max output current 30 A. POB30D Generates 10 V to 300 V DC on coils outputs. Max output current 30 A. No AC voltage available. No external trigger connector available. POB40ADL Generates 1 V to 50 V DC and 1 V to 40 V AC on coils outputs. Motor output range selectable from 1 V to 50 V DC. 5

POB40D Generates 10 V to 300 V DC on coils outputs. No AC voltage available. No external trigger connector available. POB40DL Generates 1 V to 50 V DC on coils outputs. Motor output range selectable from 1 V to 50 V DC. POB40AD Generates 10 V to 300 V DC and 10 V to 250 V AC on coils outputs. 6

Order info: Instrument Coil Tester Power Supply POB40AD Coil Tester Power Supply Coil Tester Power Supply POB30D Coil Tester Power Supply POB40ADL Coil Tester Power Supply POB40D Coil Tester Power Supply POB40DL Art.No. POB40AD-N-00 -N-00 POB30AC-N-00 POB40AD-N-01 POB40AC-N-00 POB40AC-N-01 Included accessories Ground cable Power supply cable Recommended accessories Cable set 6 x 2 m 2,5 mm 2 Transport case Optional Accessories Cable set 6 x 5 m 2,5 mm 2 Device bag Cable bag External Trigger cable set 2 m Coil supply cable set 2 x 2 m 2,5 mm 2 with banana plugs Art.No. C6-02-02BPBP HARD-CASE-ME Art.No. C6-05-02BPBP DEVIC-BAG-00 CABLE-BAG-00 TC-02-04MCBP C2-02-02BPBP IBEKO Power AB Contact Stockholmsvägen 18 Phone: +46 70 0925 000 181 50 Lidingö, Sweden E-mail: sales@dv-power.com 7