PIM Pressure Independence Module

Similar documents
PIM Pressure Independent Module

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

SD-1250 and SD-1600 Series Smoke Dampers

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

NOW INTEGRATED WITH MLM DESIGNED FOR VAV DIFFUSER SYSTEMS LINEAR CHARACTERISTICS NO REGULAR MAINTENANCE REQUIRED PRESSURE SENSOR AND CONTROLLERS

STR Circular VAV Terminal Units

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Acid Resistant AVC6000

Variable Air Volume Dampers

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Variable Air Volume Distribution Units CII, September 1 st, Home

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Metasys Zoning Package Installation

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

CCS Zone/Bypass Damper Assembly

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

AD-1251 Probe with Differential Pressure Transducer

Air Measuring Products AMD AMS IAQ

Laboratory Exhaust Air Terminal

FOR USE IN SOLUTION AIR HANDLING UNITS

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

For installation into ductwork

Demand Based Static Pressure Reset Control for Laboratories

VAV TERMINAL UNITS. VVD VAV Diffusers

Introduction to Johnson Controls Dampers

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Variable Air Volume (VAV) Pressure Independent Control

AMD-33 Air Measuring Station with VCD-33 Control Damper

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

IAQ. ROUND DUCT RETROFIT Model ARR

RD-2000 Round Control Dampers

AXD 530 MicroManometer

INFINITY ZONING QUICK START GUIDE

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

HCD-230 Industrial Control Damper

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Acid Resistant AVT6000

MOTORIZED VOLUME DAMPER

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

OE326-23I-OR VAV/Zone Controller

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Laboratory Room Controller

SINGLE DUCT TERMINAL UNITS

Fan - Powered Terminal Unit Series Flow

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

Laboratory Exhaust Systems

Direct Gas-Fired Heating

RETROFIT TERMINAL UNITS

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

AD-1250 Airflow Measuring Station

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

FAN POWERED TERMINAL UNITS

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Metasys Zoning Package Overview

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3.

YCCS Zone/Bypass Damper Assembly

NJK Precision Product NJK-02 Sensor Installation Guide

PC-125x Counter-Balanced Backdraft Damper

SLIM LINE FUME HOOD MONITOR

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

I Fan Powered Terminal Unit

YCCS Zone/Bypass Damper Assembly

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

NV series. Induction VAV air volume control terminals

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

Installation/ Operation Maintenance. VariTrac Dampers

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Description. functions including single duct pressure dependent or pressure independent systems.

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

Fan Powered Low Profile Variable Volume Terminal Units

EXHAUST FAN FLOW METER

Laboratory Room Single Duct Supply Air Terminal

Thermal Isolation. Break

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

CAV controllers Type RN

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Redefine your comfort zone. vav diffusers. energy solutions

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Silver Series Thermal Dispersion Airflow Measurement Technology

SECTION AIR TERMINAL UNITS

Transcription:

PIM Pressure Independence Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independence Module is a modulating static pressure controller/actuator that allows Therma-Fuser TM Diffusers to operate quietly at both full flow and turn down conditions. The PIM has a field adjustable static pressure set point and may be used in either a zone or bypass configuration. EASY INSTALLATION Featuring single point electrical and pressure tubing connections, the PIM is quick and easy to install. The PIM is available as a stand-alone or networked device and a variety of damper shapes and sizes are available so that it can be incorporated into any ductwork system. BACnet TM COMPATIBLE Integration over the BACnet network provides extensive data from each PIM including: static pressure, static pressure set point, and damper position. Simple, plug-and-play RJ-45 connections with factory supplied cables ensure correct connection to the BACnet network. v001 Issue Date: 12/14/17

PIM Pressure Independence Module HOW IT WORKS The Pressure Independence Module (PIM) regulates pressure within a Therma-Fuser diffuser system. The PIM makes use of an electronic pressure controller (PIC) to modulate a damper in response to the system static pressure setpoint and a downstream pressure probe. The PIM can be setup for either bypass control or for downstream zone control. In both applications, duct static pressure should be kept below 0.25 in. w.g. at the diffuser closest to the PIM to limit excessive diffuser noise. DIGITAL PRESSURE CONTROLLER (PIC) With advanced and configurable PI (Proportional + Integral) control, the PIC allows for exceptional pressure conrtol and energy efficiency by eliminating hunting and overshoot. Installation of the controller is quick and easy with simple RJ-45 connections to the BACnet network. Field setup changes can be accomplished with the LCD setup tool, LCD t-stat, or through BACnet front end software (BACnet expansion module required). The PIC comes standard with the following features: 1. Standard integrated actuator 2. Standard service jack for setup/balancing (LCD set-up tool required) 3. Standard indicator LEDs that show the status of all outputs for easy troubleshooting 4. Standard pressure sensor module 5. Standard static pressure probe (1/4in pneumatic tubing by others) 6. Optional BACnet expansion module with RJ-45 connection for easy connection to the network A minimum of 1 LCD Set-Up Tool should be ordered per each jobsite. PIC Digital Pressure Controller INTEGRATION WITH BACnet With native BACnet MS/TP compatibility, the PIC controller can tie into an existing or future BACnet compliant BAS system for maximum flexibility. When connected, the network can monitor all of the controller's functions and variables, assign set-points or log historical data. A computer on the BACnet network can be used to configure PIC controllers instead of the local LCD setup tool. GUIDE SPECIFICATION Available for download at acutherm.com LCD set-up tool RJ12 grey cable comes with lcd set-up tool PIM controller 1/4" Tubing by others Install 2/3 to 3/4 of the way down main duct 24Vac 6va supply power (by others) transformer available Static pressure probe in the supply duct 2

PIM Pressure Independence Module SYSTEM DESIGN BYPASS APPLICATION Bypass control maintains a constant pressure setpoint and bypasses the air from the supply to the return side. The return duct can either be ducted back to the main air handling unit or have an open return. In this application, the PIM should be installed between the supply and return duct, and the static pressure probe should be installed 2/3 to 3/4 of the way down the longest duct run. When the static pressure in the duct increases past the setpoint, the PIM will open the damper to increase the amount of air bypassed. On a decrease in duct static pressure, the controller will close the damper to reduce the amount of air bypassed, thereby holding the duct static pressure constant. BAS Computer for BACnet Op on AHU 1/4 in PIM. pne c tu uma bing by oth Sta c pressure probe located 2.3 or 3/4 down duct ers Supply Air Temperature Sensor Therma-Fuser Diffusers ZONE APPLICATION In the zone application the PIM is located directly in the supply duct before the first Therma-Fuser diffuser. The static pressure probe is placed downstream of the PIM unit, allowing the damper to maintain a constant downstream pressure setpoint through modulation of an internal damper. To maintain the desired duct static pressure, the controller will close the damper in response to an increase in duct static pressure to restrict airflow, while in response to a decrease in duct static pressure the controller will open the damper to increase airflow. BAS Computer for BACnet Op on Op o nal B AC n e t ne wir twork 1/4 in Supply Air Temperature Sensor um. pne ing fo a c tu r BAC bing net ex by oth pansi ers on m odule Sta c pressure probe located 2.3 or 3/4 down duct PIM Sta c Pressure Sensor Therma-Fuser Diffusers 3

PIM Pressure Independence Module DIMENSIONAL DATA PIM - Round Dimensional Data Unit Size L/s Range cfm Range I-P Units (in.) S.I. Units [mm] A L A L 6 0-212 0-450 6 20 3/8 152 518 8 0-378 0-800 8 20 3/8 203 518 10 0-637 0-1350 10 20 7/8 254 530 12 0-991 0-2100 12 23 1/8 305 587 14 0-1416 0-3000 14 24 1/8 356 613 16 0-188 0-4000 16 26 1/8 406 664 Notes: PIM enclosure assembly will be supplied on right hand side unless specified otherwise. Dampers supplied as shown feature factory mounted PIM controller within the enclosure. Optional step down transformers with single point service available mounted within the enclosure. PIM - Rectangular Dimensional Data I-P Units [in.] S.I. Units [mm] W H W H Min. Max. Min. Max. Min. Max. Min. Max. 6 48 6 36 152 1219 152 914 Notes: Dampers supplied as shown feature factory mounted PIM controller within the enclosure. Optional step down transformers with single point service available mounted within the enclosure. W 5 3/4" (146) 10" (254) H 13 1/4' (337) 7/8" (22) 5" (127) 4 DAMPER DIMENSIONS W H MIN MAX MIN MAX 6" (152) 48" (1219) 6" (152) 36" (914)

PIM Pressure Independence Module RECOMMENDED AIR VOLUME RANGES - PIM ROUND SELECTION For zone applications, the PIM is sized in accordance with the design flow through the duct run supplied by the PIM. Selecting the PIM in the mid range will allow for future changes. For bypass applications, the PIM is sized to handle the bypass air volume when all of the Therma-Fuser diffusers turn down for the zone or branch controlled by the PIM. This will typically be 100% of maximum design flow minus any minimum flow set at the diffusers. FIELD ADJUSTMENT OF PRESSURE CONTROLLER The pressure controller set-point will be determined by the actual pressure losses of the branch duct and diffusers, and cannot be accurately predicted. Field adjustment of the PIM setpoint is done using the LCD set-up, LCD t-stat, or BACnet interface. The PIM pressure controller is factory set for a default value of 0.15 in. w.g. / 37 Pa. Quick Selection - Round Dampers Unit Size Max cfm at 2000 fpm Max l/s at 10.2 m/s 6 393 185 8 698 329 10 1090 514 12 1570 741 14 2137 1008 16 2791 1317 5

Steel PIM Pressure Independence Module RECOMMENDED OPERATING PRESSURE - PIM SQUARE/RECTANGULAR Damper size* Max cfm at 1000 fpm Max l/s at 5.1 m/s 12x12 1000 472 18x16 2000 943 24x16 3000 1415 30x24 5000 2358 36x30 7500 3538 48x30 10000 4717 *Square/rectangular dampers are available in a wide variety of sizes in addition to those shown. PRESSURE DROP - PIM SQUARE/RECTANGULAR Pressure drop testing was conducted by an independant laboratory in accordance with AMCA Standard 500-D, Fig. 5.3 ductwork upstream & downstream. LEAKAGE - PIM SQUARE/RECTANGULAR Leakage Performance test was conducted by an independant laboratory in accordance with AMCA Standard 500-D and is expressed as CFM/SQ. FT. of damper face area. Test size: Damper size 36 x 48. 6 ns ( ) are soft conversion. Copyright E.H. Price Limited 2012. s are converted to metric and rounded to the nearest millimetre.

PIM Pressure Independence Module BALANCING PROCEDURE The objective when balancing a system with Therma-Fuser diffusers is to ensure that design airflow is achieved at the diffuser with the highest pressure drop (typically the last diffuser downstream of the PIM), ensure that the static pressure at the inlet to the diffuser with the lowest pressure drop (typically the diffuser closest to the PIM) does not exceed 0.25 wg / 62Pa and to do so at the lowest possible static pressure to minimize the fan energy used. Satisfying the first two conditions will allow the Therma-Fuser diffusers to modulate and control each space in a quiet and energy efficient manner. PROPORTIONAL BALANCING PROCEDURE 1. Adjust the fan speed to 100% 2. Adjust each PIM zone independently. Each PIM (and the diffusers downstream) is balanced as an independent zone and the PIM static pressure set point adjusted to maintain the design airflow at the Therma-Fuser diffuser with the highest pressure drop. a. Adjust the PIM set point to 0.15 wg / 37Pa. b. Open all Therma-Fuser diffusers in the PIM zone (see individual model of diffuser for opening instructions). c. Ensure all manual volume (balancing) dampers are 100% open. d. Allow a little time (5-10 minutes) for the PIM to control to the set point. e. Measure the airflow at each diffuser. f. Compare the measured airflow with the design airflow for each space and: i. Determine which diffuser is the lowest with respect to the design airflow. This is the diffuser with the highest pressure drop. ii. Determine which diffuser is the highest with respect to the design airflow. This is the diffuser with the lowest pressure drop. g. Do not close the manual damper on the diffuser with the highest pressure drop. Keep this damper 100% open. h. Adjust the manual volume damper on each of the other diffuser to match the percentage from the design airflow as that of the diffuser with the highest pressure drop. i. Adjust the PIM set point until design airflow (+10% / -5%) is achieved at the diffuser with the highest pressure drop. Allow a little time (5-10 minutes) for the PIM to control to the set point. j. Check the static pressure at the takeoff to the diffuser with the lowest pressure drop (static pressure should be less than or equal to 0.25 wg / 62Pa). k. Check the remaining diffusers on the PIM zone to ensure all are supplying greater than or equal to design airflow. l. Note the PIM set point. m. Return all Therma-Fuser diffusers in the zone to operation (see individual model for instructions). 3. Repeat for each PIM zone on the system. 4. Adjust the fan speed. Once each PIM zone has been balanced and the PIM set points adjusted, identify the PIM zone with the highest pressure drop (typically the zone furthest from the fan or the PIM with the damper open the furthest). a. Open all Therma-Fuser diffusers in the PIM zone (see individual model of diffuser for opening instructions). b. Establish the static pressure set point for the fan speed control by turning it down to the slowest speed that will maintain the design airflow at the highest pressure drop diffuser in the highest pressure drop PIM zone (PIM damper should be open to almost 100%). c. Return all Therma-Fuser diffusers in the zone to operation (see individual model for instructions). NOTE: Diffuser noise is caused by higher velocity air through the diffuser which is caused by a high static pressure. Acutherm recommends a static pressure no higher than 0.25 wg / 62Pa at the inlet to the diffuser. Some system designers may accept higher noise levels and opt for a higher static pressure. Care should be taken not to exceed the design maximum static pressure at the takeoff to the first diffuser after the PIM. 7

2017 Acutherm PIM Pressure Independence Module TWO YEAR WARRANTY Acutherm warrants that its PIM (Pressure Independence Module), exclusive of any options and accessories (whether factory or field installed) shall be free from defective material or workmanship for a period of two (2) years from the date of shipment and agrees to repair or replace, at its option, any parts that fail during said two (2) year period due to any such defects which would not have occurred had reasonable care and proper usage and all parts and controls remain unaltered. Acutherm makes NO WARRANTY OF MERCHANTABILITY OF PRODUCTS OR OF THEIR FITNESS FOR ANY PURPOSE OR ANY OTHER EXPRESS OR IMPLIED WARRANTY WHICH EXTENDS BEYOND THE LIMITED WARRANTY ABOVE. ACUTHERM S LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES RESULTING FROM DEFECTS SHALL IN NO EVENT EXCEED THE COST OF REPAIR OR REPLACEMENT OF PARTS FOUND DEFECTIVE UPON EXAMINATION BY ACUTHERM. IN NO EVENT SHALL ACUTHERM BE LIABLE FOR INCIDENTAL, INDIRECT OR CONSEQUENTIONAL DAMAGES OR DAMAGES FOR INJURY TO PERSONS OR PROPERTY. Acutherm shall not be responsible for freight to or from its plant in connection with the inspection, repair or replacement of parts under the terms of this limited warranty nor for cost of removal or installation. ACUTHERM PRODUCT GUIDE Square VAV Diffusers Round VAV Diffusers Linear VAV Diffusers Options and Accessories Pressure Control PRODUCT INFORMATION DESCRIPTION Use the following model number nomenclature to order PIM Pressure Independence Modules, options and accessories. (1) Model PIM (2) Units (3) Configuration (4) Round Inlet Size (5) Rectangular Inlet Size Product 1. Model: PIM Pressure Independence Module 2. Units: IN Inches, MM Milimeters 3. Configuration: PIC PIC Only, PIC + Enclosure PIC+SQ PIC and Square or Rectangular Damper, PIC+RD PIC and Round Damper 4. Round Inlet Size: 6, 8, 10, 12, 14, 16 Inch Inlet 5. Square/Rectangular Damper Size: Damper Width x Damper Height Options (1) Control Configuration (2) Transformer (3) Network Options 1. Control Configuration: B Bypass Control, Z Zone Control 2. Transformer: None, 24-24V DDC Isolation, 120-24V Step Down, 230-24V Step Down 3. Network: BAC Native BACnet MS/TP Interface Accessories (1) LCD Set-Up Tool (2) Blade Seals (3) Transitions Accessories 1. LCD Set-Up Tool 2. Blade Seals: LL Low Leakage Blade Seals 3. Transitions: STR Square to Round Inlet, RTS Round to Square Outlet AVAILABLE ONLINE Access digital brochures, CAD files, performance data and more! www.acutherm.com CALL US Talk to our customization and specification experts +1 800 544 1840 EMAIL SUPPORT Send us your questions and we ll get you the answers you need. techsupport@acutherm.com ACUTHERM HEADQUARTERS 6379 Clark Ave, Suite 280, Dublin CA 94568, USA Tel: +1 510 785 0510 Fax: +1 510 785 2517