Threshold Sensors... 2-3 locking Valves...4 3-Way, 2-osition Standard Duty... 5-8 Technical Data...9 Dimensions... 10-11 3-Way Miniature...12 Dimensions... Miniature and Standard Duty Limit Switches, ylinder Mounted Threshold Sensors, locking ir ontrol Valves Section old text part numbers are standard. Standard text part numbers may have longer lead times. arker annifin orporation Division
atalog 0600-7/US asic eatures llen ey Sensor Locking lip ircuit ressure /12 5/32" Tube Instant onnections Driving ressure U xhaust ack ressure Threshold Time Valve Switch Over nd Of Stroke lack rown () lue (N) (U) anjo Sockets (with Sensor lip) ort Size Wrench 10-32 WS1557 5/16" ex 1/8" WS1887 3/16" llen 1/4" WS1997 5/16" llen 3/8" WS37 3/8" llen 1/2" WS17 1/2" llen N Threshold Sensors pplication The threshold sensor provides electrical or pneumatic feedback information on pneumatic (air) cylinder status. These devices monitor the back pressure of the cylinder's exhausting chamber. When the cylinder stops, the back pressure drops and the threshold sensor provides the desired output. Ideal for variable stroke applications. The banjo fitting and the feedback element are two separate subassemblies, giving the user flexibility between electrical and pneumatic outputs as feedback. anjo fittings in 10-32 to 1/2" pipe sizes are designed to be installed directly into actuator ports (up to 5" bore cylinders). The banjo fitting can accommodate other functional fittings and components such as right angle flow control valves or blocking valves. anjo fittings screw into actuators using an llen wrench or 5/16" hex head wrench for 10-32 size. lectrical or pneumatic feedback element snaps into place using a locking clip. sensors have a continuous pressure signal applied to the sensor device. lectrical sensors have a continuous electrical signal applied to the sensor device. The threshold sensor assembly mounted directly into the cylinder port provides an output signal S, which can be pneumatic or electrical, when the falling back pressure in the exhausting chamber of the cylinder reaches the operating threshold (approximately 6-9 SI). (The device is a normally passing device. The output is only on when there is nearly zero pressure at the cylinder.) lug-in Sensors Output onnection WS111 5/32" push-in lectrical WSM1012 3-wire cable (6 ft) 2 arker annifin orporation Division
atalog 0600-7/US Dimensions & Technical Data Dimensions anjo Socket Technical Data Operating ressure 0 to 150 SI (0 to 10 bar) Temperature Range 5 to 0 (-15 to 60 )! UTION: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior. Maximum Operating requency 10 z ilot ressure (WS111) >64 SI (4.4 bar) Threshold ressure 6 to 9 SI (.4 to.6 bar) Threshold Sensors Model L WS1557.98".43".79".40".67" 5/16" ex (25) (11) (20) (10) (17) WS1887.98".63".71".40".79" 3/16" llen (25) (16) (18) (10) (20) WS1997.98".83".71".40".87" 5/16" llen (25) () (18) (10) () SW37.98" 1.10".79".47".98" 3/8" llen (25) (28) (20) (12) (25) WS17.98" 1.30".93".55" 1.02" 1/2" llen (25) (33) (24) () (26) Universal Normally Non-assing () Normally assing () /2 L Output low Rate (WS111) 3 SM at 90 SI urrent Rating (WSM1012) 5 V, 250 V 5W, 48 V lectrical Normally Open (N.O.) Normally losed (N..) Normally losed (N..) Normally Open (N.O.) WS111 WSM1012 Materials ody........... Thermoplastic Screw & Threads............. rass Life xpectancy 10 million cycles with dry air at 90 SI, 68, and 1 z operating frequency Voltage Range (WSM1012) 12-240 V 12-48 VD luid ower unction Symbol unction Symbol 2-Way.87 ().79 (20) 18 x 24 3-Way 1.26 (32).79 (20) 3 arker annifin orporation Division
atalog 0600-7/US (Revised 01/10/05) asic eatures Threaded onnections & Threaded ilot ort With Instant Tube ittings ylinder Tube ilot emale Model low Wt. ort Size Tube ilot Number (v) (oz.) 1/8" 1/4" 5/32" M5 W3468 0.78 5.1 1/4" 1/4" 5/32" M5 W3469 1.02 5.3 3/8" 3/8" 5/32" M5 W3493 1.67 6.3 1/2" 1/2" 5/32" M5 W3412 2.12 17.5 With Threaded onnections & Tube ilot ort ylinder emale ilot emale Model low Wt. Tube Tube Tube ilot Number (v) (oz.) 1/8" 1/8" 5/32"* M5 W3888 0.78 6.2 1/4" 1/4" 5/32"* M5 W3899 1.02 6.2 3/8" 3/8" 5/32"* M5 W3833 1.67 6.7 1/2" 1/2" 5/32"* M5 W38 2.12 16.8 With Threaded onnections & Threaded ilot ort ylinder emale ilot emale Model low Wt. ort ort ort ilot Number (v) (oz.) 1/8" 1/8" 1/8" ipe M5 W38887 0.78 6.2 1/4" 1/4" 1/8" ipe M5 W38997 1.02 6.2 3/8" 3/8" 1/8" ipe M5 W38337 1.67 6.7 1/2" 1/2" 1/8" ipe M5 W387 2.12 16.8 *Instant tube connection Dimensions To ower Valve L Instant Tube ittings Instant Tube ittings ontrol L Threaded onnections & Tube ilot Threaded onnections & Tube ilot ort To ylinder 1/8" T L Threaded onnections & Threaded ilot ort locking Valves pplication locking valves are designed for precise, repeatable stopping of moving cylinders or to maintain the position of a cylinder in the event of an air pilot signal loss. lockers are used for positioning, jogging, and safety purposes. Symbol blocking valve has a spring loaded poppet which normally prevents flow through the valve in both directions. When an air pilot control signal (see pilot pressure chart below for required pilot signal pressure) is applied to the top of the valve, the poppet opens and allows the valve to flow in both directions like a standard fitting. When the pilot signal is removed, the poppet springs shut and prevents air from entering or leaving cylinder, thus stopping cylinder travel. locking valves are designed to be installed directly into actuator ports (up to 5" bore cylinders). Technical Data Operating ressure: 0 to 150 SI (0 to 10 bar) Temperature Range: 5 to 0 (-15 to 60 ) Maximum Operating requency: 10 z Life xpectancy: 10 million cycles @ 90 SI, 68, dry air and 1 z operating frequency Materials: ody... Zinc alloy screw and threads... rass ilot ressure (SI) Operating 1/8" 1/4" 3/8" 1/2" ressure ilot Depilot ilot Depilot ilot Depilot ilot Depilot 30 34 34 36 45 26 60 40 26 40 26 40 25 50 31 90 45 31 45 31 45 30 54 35 115 50 35 50 35 50 34 59 41 Size Dia. ex L 1/8".75".87".83 2.20".67" 1.73" (19) () () (56) (17) (44) 1/4".75".87".83 2.20".67" 1.73" (19) () () (56) (17) (44) 3/8" 1.06" 1.18" 1.06 2.64".91" 1.42" (27) (30) (27) (67) (23) (36) 1/2" 1.06" 1.18" 1.06 2.64".91" 1.42" (27) (30) (27) (67) (23) (36) 4 arker annifin orporation Division
atalog 0600-7/US X101, X106 pplication These switches (valves) are designed to operate single acting cylinders or provide pilot signals for larger valves. maintained mechanical force applied to the plunger shifts the poppet in the valve. When the force is removed, the valve poppet returns to its normal position. These Switches (valves) may be oriented in any position and are designed to be surface mounted using the through holes provided in the valve body. ll porting exits the bottom of the valve through three 5/32" instant tube fittings. Normally Non assing () Normal osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. ctuated osition Inlet port is connected to outlet port. xhaust port 10 is blocked. Normal osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. ctuated osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. lunger Operated, lunger Operated, Operator Only X101 X101 X101 ZD10 3-Way, 2-osition Standard Duty pplication These switches (valves) are designed to operate single acting cylinders or provide pilot signals for larger valves. Very low force deflection of the whisker shifts the poppet in the valve. When the force is removed, the valve poppet returns to its normal position. These switches (valves) may be oriented in any position and are designed to be surface mounted using the through holes provided in the valve body. ll porting exits the bottom of the valve through three 5/32" instant tube fittings. Normally Non assing () Normal osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. ctuated osition Inlet port is connected to outlet port. xhaust port 10 is blocked. Normal osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. ctuated osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. Whisker Operated, Whisker Operated, Operator Only X106 X106 X106 ZD06 5 arker annifin orporation Division
atalog 0600-7/US X102, X1 pplication These switches (valves) actuate when approached from both directions, and may be used to operate single acting cylinders or provide pilot signals for larger valves. maintained mechanical force applied to the roller shifts the poppet in the valve. When the force is removed, the valve poppet returns to its normal position. These switches (valves) may be oriented in any position and are designed to be surface mounted using the through holes provided in the valve body. ll porting exits the bottom of the valve through three 5/32" instant tube fittings. X102 Normally Non-assing () Normal osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. ctuated osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. Normal osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. ctuated osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. Roller/lunger Operated, Roller/lunger Operated, Operator Only X102 X102 ZD02 3-Way, 2-osition Standard Duty pplication These switches (valves) actuate when approached from both directions and may be used to operate single acting cylinders or provide pilot signals for larger valves. maintained mechanical force applied to the roller shifts the poppet in the valve. When the force is removed, the valve poppet returns to its normal position. These switches (valves) may be oriented in any position and are designed to be surface mounted using the through holes provided in the valve body. ll porting exits the bottom of the valve through three 5/32" instant tube fittings. Normally Non-assing () Normal osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. ctuated osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. Normal osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. ctuated osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. Delrin Roller/am Operated, Delrin Roller/am Operated, Steel Roller/am Operated, Steel Roller/am Operated, Delrin Roller Operator Only Steel Roller Operator Only X1 X1 X1 X123 X123 ZD ZD23 6 arker annifin orporation Division
atalog 0600-7/US X10031, X10041 pplication These switches (valves) actuate when approached from both directions, or can be programmed to actuate from one direction, and may be used to actuate single acting cylinders or provide pilot signals for larger valves. maintained mechanical force applied to the roller shifts the poppet in the valve. When the force is removed, the valve poppet returns to its normal position. These switches (valves) may be oriented in any position and are designed to be surface mounted using the through holes provided in the valve body. ll porting exits the bottom of the valve through three 5/32" instant tube fittings. X10031 Normally Non assing () Normal osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. ctuated osition Inlet port is connected to outlet port. xhaust port 10 is blocked. Normal osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. ctuated osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. Delrin Roller/Rotary Operated, Delrin Roller/Rotary Operated, Steel Roller/Rotary Operated, Steel Roller/Rotary Operated, Rotary ead Only Delrin Roller Lever Only Steel Roller Lever Only X10031 X10031 X100 X100 Z00 ZY31 ZY 3-Way, 2-osition Standard Duty pplication These switches (valves) actuate when approached from both directions, or can be programmed to actuate from one direction, and may be used to actuate single acting cylinders or provide pilot signals for larger valves. maintained mechanical force applied to the roller shifts the poppet in the valve. When the force is removed, the valve poppet returns to its normal position. Roller height is field adjustable. These switches (valves) may be oriented in any position and are designed to be surface mounted using the through holes provided in the valve body. ll porting exits the bottom of the valve through three 5/32" instant tube fittings. X10041 Normally Non assing () Normal osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. ctuated osition Inlet port is connected to outlet port. xhaust port 10 is blocked. Normal osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. ctuated osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. dj. Delrin Roller/Rotary Operated, dj. Delrin Roller/Rotary Operated, dj. Steel Roller/Rotary Operated, dj. Steel Roller/Rotary Operated, Rotary ead Only dj. Delrin Roller Lever Only dj. Steel Roller Lever Only X10041 X10041 X10043 X10043 Z00 ZY41 ZY43 7 arker annifin orporation Division
atalog 0600-7/US X1081, X1091 pplication These switches (valves) actuate when approached from both directions, or can be programmed to actuate from one direction, and may be used to actuate single acting cylinders or provide pilot signals for larger valves. maintained mechanical force applied to the spring rod shifts the poppet in the valve. When the force is removed, the valve poppet returns to its normal position. These switches (valves) may be oriented in any position and are designed to be surface mounted using the through holes provided in the valve body. ll porting exits the bottom of the valve through three 5/32" instant tube fittings. X1081 Normally Non assing () Normal osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. ctuated osition Inlet port is connected to outlet port. xhaust port 10 is blocked. Normal osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. ctuated osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. lastic Spring Rod/Rotary Operated, lastic Spring Rod/Rotary Operated, Rotary ead Only lastic Spring Rod Only X1081 X1081 Z00 ZY81 3-Way, 2-osition Standard Duty pplication These switches (valves) actuate when approached from both directions, or can be programmed to actuate from one direction, and may be used to actuate single acting cylinders or provide pilot signals for larger valves. maintained mechanical force applied to the spring rod shifts the poppet in the valve. When the force is removed, the valve poppet returns to its normal position. These switches (valves) may be oriented in any position and are designed to be surface mounted using the through holes provided in the valve body. ll porting exits the bottom of the valve through three 5/32" instant tube fittings. X1091 Normally Non assing () Normal osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. ctuated osition Inlet port is connected to outlet port. xhaust port 10 is blocked. Normal osition ressure at inlet port is connected to outlet port. xhaust port 10 is blocked. ctuated osition ressure at inlet port is blocked. Outlet port is connected to exhaust port 10. Metal Spring Rod/Rotary Operated, Metal Spring Rod/Rotary Operated, Rotary ead Only Metal Spring Rod Only X1091 X1091 Z00 ZY91 8 arker annifin orporation Division
atalog 0600-7/US Technical Data Operating ressure 44 to 0 SI (3 to 9 bar) Temperature Range (mbient) 5 to 0 (-15 to 60 )! UTION: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior. low Rating (v).12 v ctuation at 90 SI 3-Way, 2-osition Standard Duty Materials ody............... Zinc alloy oppet........... olyurethane Seals.................. Nitrile iltration 50µ filtered Lubrication or maximum service life, use clean lubricated air. Valves are shipped prelubricated and can be operated without additional lubrication at reduced service life. Suggested Lubricant 442 Oil Mechanical Life 10 million cycles with dry air at 90 SI, 68 and 1z frequency Maximum Operating requency 5z Muffler - XX Muffler installs into 5/32" tube exhaust port lunger ctuated X2**10 X2**02 X2** X2**06 Operating ngle () 35 Differential ngle 12 Minimum re-travel ().080".080".100" Differential Travel.008".008".008" Maximum Travel ().235".235".275" Minimum Operating orce 36 oz. 36 oz. 25 oz. Minimum Operating Torque 18.4 in-oz Maximum Tracking Speed 98 fpm 98 fpm 295 fpm w/30 cam 197 fpm Rotary ead Operating ngle: 31 (minimum lever travel including pretravel required for operation) Differential ngle: 3 Maximum ngle of Travel: 80 Minimum Operating Torque: in-oz. Rest Maximum travel Rest Maximum travel Rest Selecting ead unction Maximum travel 9 arker annifin orporation Division
atalog 0600-7/US Dimensions X2*110 D D J D X2*106 1 3-Way, 2-osition Standard Duty D1 D1 1 1 1 0.16 4 1 0.31 8 Dia. 0.51 1Dia. 0.79 20 1.91 48.5 1 Inches mm 0.55 1 0.63 16 3.48 88.5 1 7.91 201 0.79 20 D 2.09 53 D1 6.52 165.5 Dia. 0.20 5.2 Dia. 0.39 10 Dia. 0.08 2 Inches mm X2*102 X2*S, 23 0.59 15 4. 107 1 4.43 112.5 0.79 20 D 2.81 71.5 D1 3.03 77 Dia. 0.20 5.2 Inches mm X1 (), X1 () Switch odies 1.16 29.5 1.10 28 = = 0.79 20 D 2.50 63.5 Dia. 0.20 5.2 0.39 10 0.77 19.5 0.87 J 0.61 15.5 0.35 9 10 arker annifin orporation Division
atalog 0600-7/US Dimensions X2*1031, 0 = D X2*1081 D J = X1 (), X1 () Switch odies D J 1 3-Way, 2-osition Standard Duty X2*1041, 043 1 X2*1091 D1 1 D1 1 1 1 J1 Inches mm 2. 54 1 2.05 52 4.72 120 0.79 20 D 3.33 84.5 D1 min 2.87 72.9 D1 max 5.02 127.4 Dia. 0.20 5.2 0.24 6 Dia. 0.87 1 Dia. 0.75 19 2.36 60 1 2.28 58 J 1.50 38 J1 1.73 44 1.61 41 1 min 1.16 29.5 1 max 3.31 84 Inches mm 2.05 52 5.31 5 1 7.87 200 D 3.60 91.5 D1 6.18 157 Dia. 0.31 8 1 Dia. 0.12 3 Inches mm 1.16 29.5 1.10 28 0.79 20 D 2.50 63.5 Dia. 0.20 5.2 0.39 10 0.77 19.5 0.87 J 0.61 15.5 0.35 9 11 arker annifin orporation Division
atalog 0600-7/US XM111, XZ11, XM1, XM5 XM111 pplication These valves are used to operate single acting cylinders or to provide pilot signals for larger valves. maintained mechanical force applied to the plunger shifts the valve. When the force is removed, the valve returns to its normally closed position. asic valve may be fitted with roller or one-way roller operators. These valves may be oriented in any position and are designed to be inline mounted or surface mounted using the through holes provided in the valve body. XZ11 Normal position ressure at Inlet port is blocked. Outlet port is vented to xhaust. ctuated position ressure at Inlet port is connected to Outlet port. xhaust vent is blocked. Wt. (oz.) lunger operated, spring return with 10-32 threaded connections XM115 1.1 lunger operated, spring return with 5/32" tube fittings XM111 1.1 lastic roller lever XZ11 0.3 lastic roller lever, one-way trip XZ12 0.3 3-Way Miniature XM1 pplication These valves actuate when approached from both directions and are used to operate single acting cylinders or to provide pilot signals for larger valves. maintained mechanical force applied to the roller shifts the valve. When the force is removed, the valve returns to its normally closed position. These valves may be oriented in any position and are designed to be inline mounted or surface mounted using the through holes provided in the valve body. Normal position ressure at Inlet port is blocked. Outlet port is vented to xhaust. ctuated position ressure at Inlet port is connected to Outlet port. xhaust vent is blocked. XM5 Wt. (oz.) Roller operated, spring return with 10-32 bottom connections XM125 1.4 Roller operated, spring return with 5/32" bottom tube fittings XM1 1.4 Roller operated, spring return with 5/32" side tube fittings XM5 2.1 12 arker annifin orporation Division
atalog 0600-7/US Dimensions & Technical Data Dimensions XM111. (5).41 (10). (4) XM1.96-1.10 (25-28) 2 x.17 (4.2).80 (20).87 () 1. (29) unct. stroke.04 (0.9). (3.2) Dia. 2 oles Max. stroke.06 (1.4) Technical Data.41 (11).96 (25) Temperature Range (mbient) 5 to 0 (-15 to 60 ) UTION: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior. 3-Way Miniature Operating ressure Maximum Operating requency low Rating v 45 to 115 SI (3 to 8 ar) 5 z XM111.................04!.69 (17.5).79 (20) 1.10 (28) unct. stroke.08 (2).55 () Max. stroke. (3.2).26 (7).59 (15) 1.61 (41) Travel Dimensions (at 90 SI) XZ11.94 (24) 1.06 (27) 2 x.17 (4.2) 1.38 (35) XM5.91 (23).79.35 (20) (9) 1.34 (34).31 (8) unct. stroke.09 (2.2).55 () Max. stroke.23 (5.8).12 (3).26 (7).59 (15) 2.05 (52) XM115.................04 Materials XM1.................05 ody............. Zinc lloy XM125.................04 oppets......... olyurethane Seals................. Nitrile XM5.................16 XZ12.75 (19) 1.38 (35).39 (10) XM111 XM1 XM5 Minimum pretravel ().035".079".087" Differential travel.006".012".020" Maximum travel ().005".126".8" Minimum force 18 oz. 7.5 oz. 12 oz. Maximum speed 98.4 fpm 197 fpm with 30 cam 197 fpm with 30 cam Rest Rest Rest Maximum travel Maximum travel Maximum travel.16 (4) arker annifin orporation Division