MRXBOX-VSC Visual System User Control Installation and Maintenance

Similar documents
Q-AIRE-V125, EV125F & EV125FH 125mm diameter Filtered Inlet/Extract Air Valve. n Low profile. n Adjustable for commissioning purposes

XS Fans Switches & Sensors

QUIETSCROLL TWIN FAN RANGE

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

3ph Belt Drive, Run & Standby, Roof & Plantroom Twinfans

DX Ceiling Fan Kit 50Hz/60Hz Supply / Extract Units Installation and Maintenance

NALTF & NALTRF Belt Drive Roof and Plantroom Twinfans

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

Terminator Input. (TIA) GRP Roof/Wall Input/Supply Fans. Installation and Maintenance

AXS. Installation and Maintenance. AXUS Swift Circular Long Cased Axial Flow Fans. 1.0 Introduction. 3.0 Installation And General Advice. 2.

Single Phase Electronic Speed Controllers

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Installation and Maintenance

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

DX Window Fan Kit 50Hz/60Hz Supply / Extract Units Installation and Maintenance

Drimaster365. Low Energy Positive Input Ventilation Unit. Installation and Maintenance Details. 150mm dia. Flexible Ducting

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

2.0Ah BATTERY INSTRUCTION MANUAL

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

IAQ-V mm Ø Carbon Filtered Supply Valve

PSU EN54-4 Power Supplies

AXUS AXR. Roof Mounted Axial Fan for Smoke Control Installation and Maintenance. Handling

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

Installation and Operation Instructions

HST -LS Interlocking device (Translation of Original Manual)

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

User Guide for Viridian EV Charging Stations

Electrical Installation

Owner Handbook. Nebula Blizzard v3. Snow Machine. L69500 Nebula Blizzard v3.indd 1 14/07/ :47

Harness the Power of the Sun

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

HAN-L62 MOUNTING PLATE

GS-AQ1000 VOC Indoor Air Quality Sensors

Video & Power Over Coax Kit

Electric Vehicle Charging Station

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

K25000 & KD25000 Series

Pure Sine Wave Inverter 600W-24V User Manual

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

LEAD ACID BATTERY CHARGER

12 amp RMS Battery Charger

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

The Traveler Series: Adventurer

B-RAD Select USER MANUAL TABLE OF CONTENTS

English. Instruction and operation manual S 212. Dew point sensor

TRANSPONDER TERMINAL MANUAL. Version: July 2012

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Language specific user manuals are available on

Know your energy display. See where you could save energy and money

EASY CHARGE Weather-resistant fixed mount Battery Charger

Data Sheet BP v 100Ah LiFePO 4 (Peli TM Case Kit)

Conserve Insight Energy Use Monitor. User Guide

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

c-go 24V/6A 24V/8A 24V/12A

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Hub Kit Fitting Guide 36V/HL

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Battery Booster Pack. Instruction Manual for P/N

4 in 1 Digital Air Compressor Instruction Manual


CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Safety & Installation Instructions

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Car Battery Charger Instructions for Use

Auxiliary Status Switch Kit

CH5000 Heat Recovery Ventilator

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Instruction Manual Montage- und Betriebsanleitung Notice d utilisation

Battery Charger JCB-FCH12Li

Pan and Tilt Head CDD2416-T

EASY CHARGE Waterproof portable Battery Charger

Language specific user manuals are available on

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Battery Charger JCB- SCH20LI.2

Installation and Operating Instructions. Solar System Controller ISC3030

HARDWARE KIT INSTALLATION GLOVES

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Daylight Rechargeable Portable Light

Safety and General Information

Hub Kit Fitting Guide 2016

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

SB SWITCH CONTROL BOX

Multi-Mover Charger for model L25

Grant Grid-Connected Inverter For Grant Solar PV Systems. Installation & User Instructions

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Warning. Document ref: A October 2015

Installation instructions for the TriVision Car Docking Station

DIGITAL BATTERY TESTER 12V

Transcription:

MRXBOX-VSC Visual System User Control Installation and Maintenance The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 INTRODUCTION The MRXBOX-VSC is a user control from the Ecosmart range. These wall mounted user controls include a 3.5 colour LCD touchscreen display to provide improved user interface. The unit can be surface or semi-recessed mounted and is compatible with standard 2-gang recess back box. The control is manufactured from an all plastic construction and supplied with 10m of pre-plugged connection cable and surface mounting back box. Units are SELV (12 Vdc) with the power supplied from the fan unit via the pre-plugged cable. 2.0 DIMENSIONS 2. Unclip the front bezel from the unit and remove the 2 retaining screws, then remove the working section from the back box (see figure Figure 3). 3. Feed the cable through the knock-out hole in the base of the back box and mark the fixing point on the wall, drill appropriately sized holes at the required fixing points and insert the wall plugs. Fix the back box on to the wall (see figure Figure 4). 4. Plug the data cable into the socket (see figure Figure 5). 5. Fix the unit back into the back box using the screws supplied, then clip the bezel back on the unit again noting which way is up. (Top is printed on the inside face of the bezel and middle section) (see figure Figure 6). Figure 1. Unit Dimensions B E = Screen width C = Surface mounting depth Figure 2. To fan connector box terminal marked NET 10m sensor connection wire (supplied) Clearance aperture for wire should be approx. 20mm dia to allow passage of plug end. Allow approx 120mm of wire through for fitting to the backplate. Wall Wire can be located behind a wall panel or fixed to wall surface. 3.0 INSTALLATION A D = Recessed mounting depth F = Screen depth Dimensions A B C D E F MRXBOX-VSC 145 85 35 6 73 57 IMPORTANT INSTALLED ENVIRONMENT: 0-40 C and <90% RH (non-condensing) Caution: The unit must be installed away from any direct source of heat (e.g. radiators) and not in areas where it would be subjected to steam or water spray. The mounting surface must be free from vibration. Figure 3. Figure 4. Figure 5. Remove the bezel and 2 screws to detach front of unit from back box. Bezel Feed cable through hole in back box. Fix back box to wall using screws. Plug end mounted into the PCB socket inside the front half of the unit. Note that the data cable socket is positioned at the top corner of the unit. Back box Front of unit The unit is supplied with back box suitable for surface mounting (see Figure 2 - Figure 6). If semi-recess (final projection from wall is approximately 7mm) is needed, a proprietary 2-gang back box (25mm deep minimum) may be used. Figure 6. Bezel Back box. Always physically check the suitability of the back box before fitting. In some instances, the earthing point of the back box may foul the unit and need to be removed. 1. Fix one end of the 10m cable to the fan s Ecosmart connection point and route the cable to the mounting position. TOP Front of unit 1

3.1 Data Cable Installation A 4-core SELV data cable is used to connect the control to the fan. Do not run data cable in the same conduit as the mains cables and ensure there is a 50mm separation between the data cable and other cables. For cable lengths in excess of 10m a MRXBOX-JB will be required to provide sufficient power. Keep the number of cable joints to a minimum to ensure the best data transmission efficiency between devices. IMPORTANT Due to the higher current consumed by the MRXBOX-VSC, the maximum cable run between the fan control and the MRXBOX-VSC must be limited to 50m. 4.0 OPERATING MRXBOX-VSC Using the Visual display screen will override any unit mounted controls. 4.1 The Home Screen Time Outside Temperature Status Indication Filter Change Warning Speed Indicator / Adjustment Average Indoor Temperature Access to Function Screens 4.2 The Settings Screen Access for User Guide User Options Diagnostics - used in the event of a fault Commissioning screens for systems set up. PIN controlled Maintenance used to reset filter change time 2

5.0 USER INTERFACE 5.1 User Options Screen 5.4 Timed Boost 5.2 Night Time Mode Timed boost Allows you to adjust the time the ventilation system boosts when the speed setting is changed via the home screen, this can be set between 1 and 60 minutes. Alternatively if NONE is selected the unit will stay at the speed chosen permanently. Note: The speed of the unit may also be controlled by other sensors fitted, some of which may have built-in run on functionality. 5.5 Summer Bypass Night Mode Allows you to set the ventilation system to run at a minimum level at night; adjustable between 4 and 8 hours. This feature can also be de-selected from this screen when in operation. 5.3 Time Summer Bypass When the weather is warm outside, the unit will automatically go into summer bypass mode, meaning the air coming into your home will not pass through the heat exchanger in the ventilation unit. This button allows you to manually activate this feature, should you wish to prevent the air coming into your home being warmed. Summer bypass is set at a default 4 hours, but you can adjust this to a maximum of 12 hours in the User Options. Time Should be set on commissioning to ensure filter reminder is accurate. This feature can also be de-selected from this screen when in operation. 3

5.6 Rising Boost Installation and Maintenance Rising Boost Allows you to set the ventilation system so that the speed of the fan increases gradually, instead of going straight into full boost. 5.7 Holiday Mode Holiday Mode Allows you to set the ventilation system to run at a minimum level while you are away. You can adjust the number of days you are away for, with a maximum of 21 days. 4

6.0 Commissioning 6.3 Frost Protection 6.1 Commissioning Screen Commissioning This should be carried out with reference to the ventilation units specific installation and maintenance instructions. By using the MRXBOX-VSC, any controls on the front of the unit will become inoperable. Note: The adhesive backed commissioning label fitted to the front panel of the ventilation unit should still be applied to seal the commissioning pot access holes. Frost Protection In the event of the outdoor temperature falling below a set rate to unit reduces the supply fan speed down to a minimum to prevent the unit freezing. The default temperature for frost protection to activate is -5 C. This can be raised to a maximum of 0 C if required. Note: This function can be disabled for 8 hours to assist commissioning. 6.4 Summer Bypass (where fitted) 6.2 Air Flow Summer Bypass The ventilation unit uses this feature to try and maintain a set temperature in the household. By default this is 25 C although this figure can be adjusted between 15 and 30 C if desired. Note: This function can be disabled for 8 hours to assist commissioning. 6.5 Humidity (where fitted) Air Flow Gives individual control of the supply and extract flow rates. The commissioning Engineer should follow the requirement for speed 1 (trickle) and speed 2 (boost) as per Building Regulation Part F ventilation and detailed in the Installation instructions for the unit. Speed 3 is for purge ventilation and is recommended to be set to 100%. Note: Speed 2 cannot be adjusted to a lower value than speed 1. Humidity The unit monitors the humidity level of the whole property and boosts the unit if the level exceeds the set point. It is recommended to set the relative humidity to 70%. 5

6.6 Run-Time 8.0 COMPATIBILITY WITH ECOSMART FAN The MRXBOX-VSC controller is 100% compatible with the Ecosmart fans and air handling units supplied with the controller. However, some other products may not be so. Please check the suitability of the fan unit before upgrading the existing user control to the MRXBOX-VSC controller. To check if the fan is suitable for upgrade, please contact Nuaire with detail of the fan code and the serial number printed on the rating label. 9.0 DIAGNOSTICS Run-Time This shows the duration the unit has been on and off. 6.7 Change PIN Diagnostics If a fault is suspected the diagnostics screen can be accessed to view the status of the unit controls, a cross indicates an issue. In the case that the communication is lost to the unit a? will be shown against all other features. If the unit has gone into failure mode it may be necessary the unit is switched off for 30 seconds and then turned back on to re-access the status of the controls. Change PIN Used to enter a PIN code. As a default 1234 is used. PIN codes are used to prevent the occupant tampering with the commissioned levels. 7.0 USER GUIDE Note: In the case of fault only qualified persons should undertake any investigation or corrective actions. Please refer to the ventilation units specific Installation and Maintenance document for information and guidance. 10.0 MAINTENANCE Maintenance After a pre-determined length of time the unit will display an icon on the home screen indicating that the filters should be changed. Once this task has been completed the feature can be reset from the maintenance screen to clear the icon. Instructions on how to complete this task can also be found on this screen. 6

11.0 WARRANTY The 5 year warranty commences on the day of delivery and includes parts and labour for the first year. The remaining period covers replacement parts only. The labour content is subject to full, free and safe access to the equipment as recommended by the CDM regulations. The warranty excludes any damage to the LCD touch screen caused by misuse of a sharp object. This warranty is void if the equipment is modified without authorisation, is incorrectly applied, misused, disassembled, or not installed, commissioned and maintained in accordance with the details contained in this manual and general good practice. The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale. Customers purchasing from outside of the UK should contact Nuaire International Sales office for further details. 12.0 AFTER SALES ENQUIRIES For technical assistance or further product information, including spare parts and replacement components, please contact the After Sales Department. Telephone 02920 858 400 aftersales@nuaire.co.uk Note: This unit contains a small lithium battery and must be disposed of by a suitable recycling centre. Do not dispose of with normal household waste. Do not burn. Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right is reserved to make such changes without prior notice. 7

FOR MORE INFORMATION www.nuaire.co.uk COMMERCIAL www.nuaire.co.uk/commercial AIR HANDLING UNITS www.nuaire.co.uk/boxerahu BIM www.nuaire.co.uk/bim NUAIRE LIMITED Western Industrial Estate Caerphilly CF83 1NA t +44 (0)29 2085 8200 f +44 (0)29 2085 8222 e info@nuaire.co.uk www.nuaire.co.uk As part of our policy of continuous product development Nuaire reserves the right to alter specifications without prior notice. Telephone calls may be recorded for quality and training purposes. 8