SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

Similar documents
Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Installation Instructions

Direct or Non-Direct Venting

venting systems for high efficiency appliances series

All-Fuel Chimney Systems

INSTALLATION AND MAINTENANCE INSTRUCTIONS

Model RIS ALL FUEL, INSULATED CHIMNEY SYSTEM 10" - 24"

Gas Venting Systems residential industrial commercial

Models PS/IPS. Stainless Steel Double Wall Positive Pressure Piping Systems FEATURES CATALOG

Large Diameter Chimney System

Model VSI-I & VSI-II Positive Pressure Venting Systems

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION.

INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER

ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD. ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.

RECEIVING AND INSPECTION

Stovepipe DVL. DuraBlack. Double-wall interior stovepipe for connecting woodstoves to chimney. ULC S641.

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

Table of Contents WARRANTY...3 APPLICATION...4 MECHANICAL...5 Joint Sealant...5 Grease Duct Standard Connection...6 Collar and Adjustable Duct

Model N. Stainless Steel Double Wall Positive Pressure Venting Systems. Special Gas Vent Applications COMMERCIAL AND INDUSTRIAL VENTING

DVL & DuraBlack. Simpson Dura-Vent Engineered Excellence

Ventinox kits. Ventinox VFT Kit without Tee. Ventinox VFT Kit with Tee. Ventinox VFT Extensions. Flexible Relining Ventinox

SIGRAM FLUE SYSTEMS LTD

SECTION 3. EXHAUST SYSTEMS

NEW All Biomass Chimney components are available in matte black. Just add "B" to the end of the part numbers you are ordering.

Modular Double-Wall Positive Pressure Chimney Boiler Breeching & Stack and Engine Exhaust Grease Duct

Installation Instructions

IDEAL STEEL HYBRID GEAR HEAD STOVES OWNER S MANUAL MODEL 210 BY WOODSTOCK SOAPSTONE COMPANY

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

ABSOLUTE STEEL HYBRID

RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO.

ELECTRONIC FIREPLACE DAMPER

Riva Plus HEAT ONLY & COMBI BOILER. Please Read This Guide Carefully and Save for Future Reference

OPTIONAL VERTICAL OR HORIZONTAL POWER VENT KIT

Yukon Oil Inspection Survey Results and Recommendations

PROGRESS HYBRID WOODSTOCK SOAPSTONE STOVES OWNER S MANUAL MODEL 209. Tested To UL 1482 Listed By Intertek Report #

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

VAREC 5910B AND 5920B SERIES RELIEF VALVE WITH FLAME ARRESTER

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

Specifications. UL 1777 and ULC S641 System. Combustion Air System-DuraTech and DuraPlus HTC

SINGLE WALL AL 29-4C SPECIAL GAS VENT

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

Flue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Installation Instructions

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

CONTENTS. Ordering Information... Page 3. Cardrona, Monaco, Geneva, Vienna... Page 4 Offset & Extension Kits For Freestanding Fires...

Fully Automatic Bilge Pump INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Technical and Dimensional Data. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

Installation Manual Installation and Appliance Setup

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

VAREC 5810B AND 5820B SERIES RELIEF VALVE WITH FLAME ARRESTER

OPTIONAL VERTICAL OR HORIZONTAL POWER VENT KIT

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

InoxSabiana 50 Flues Stainless Steel Double Wall ENVIRONMENTAL COMFORT

Installation Manual. English. French

Stovepipe DVL. DuraBlack. Double-wall interior stovepipe for connecting woodstoves to chimney. ULC S641.

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

Series. Chimney System for High Efficiency Appliances. Underwriters c. Laboratories Inc. LISTED

MODELS F822 THRU F834

FLEXIBLE PHOTOVOLTAIC MODULES. Instruction Manual

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Above Ground Oil Tanks

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

Our mission is to become the supplier of choice for gas venting products and solutions.

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS

ENGINE MEASUREMENTS ENGINE MEASUREMENTS AND SPECIFICATIONS CYLINDER HEAD. Measure Cylinder Compression. Using Telescoping Gauges and Hole Gauges

TFL Gas Log Lighter (TFLGLL)

venting systems for high efficiency appliances series

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

VENTING & COMBUSTION AIR GUIDE

Installation Instructions

Installation, Operation and Maintenance Manual

BLACKBIRD INSTALLATION SUPPLEMENT

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES

HP190SL Series Slimline Radon Fans

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

INSTALLATION INSTRUCTIONS FOR THE PHOENIX FIBER OPTIC FLAME SCANNERS

4 Installation Guidelines

Read and understand this manual for safely usage.

Transcription:

SELKIRK CORP MODEL G - CHIMNEY LINER These instructions are supplemental to the General Installation Instructions for Selkirk Model G, PS, IPS and ZC Single Wall, Double Wall Air & Fiber Insulated Positive Pressure Piping System installation instructions. Read and refer (also) to the main instructions when installing Model G as a chimney liner. Model G is a rigid, stainless steel, single wall, modular, venting system identical in construction to the inner (structural) liner of the Selkirk Model PS and IPS systems used for a variety of applications. Selkirk Model G sections incorporate a fully welded stainless steel tube construction and the same ½ wide flanged ends as the Model PS and IPS system. Model G uses many of the same system parts and accessories as the Model PS and IPS systems. As a chimney liner, Selkirk Model G is designed for use in masonry or factory-built chimneys to provide the flue gas venting of solid, liquid, and / or gas fired appliances as noted below. Model G has been tested and Listed (safety certified) to UL-1777 - STANDARD FOR CHIMNEY LINERS for use with gas fired appliances with flue gases up to 570 O F and short term exposure up to 1700 O F. Model G is Listed and produced under the Follow-Up Service program of Underwriters Laboratories, Inc. and carries the UL LISTING MARK illustrated here. Model G has been tested and Listed (safety certified) to CAN/ ULC-S635 - STANDARD FOR LINING SYSTEMS FOR EXISTING MASONRY OR FACTORY-BUILT CHIMNEYS AND VENTS for use with gas, liquid and solid fuel fired appliances with maximum continuous flue gas temperatures of 650 O C (1200 O F). Model G is Listed and produced under the Follow-Up Service program of Underwriters Laboratories, Inc. and carries the cul LISTING MARK illustrated here. GENERAL INSTALLATION CONSIDERA-TIONS: 1.) Before beginning any installation of Model G chimney liner system, consult the local code inspection authority (Gas Inspection Authority, INSTALLATION INSTRUCTION SUPPLEMENT Municipal Building Department, Fire Department, etc.) to determine the need to obtain a permit for the installation. 2.) These instructions should be observed when installing Selkirk Model G Chimney Liner. Never substitute liner material. The safe operation of the Model G lining system is based upon the use of parts supplied by Selkirk. The use / substitution of parts other than those supplied by Selkirk for use with Model G is not recommended, as they could affect the safety / performance of the system. 3.) Failure to install this product in accordance with these installation instructions may result in an installation that the local inspection authority will not accept, could void the warranty and / or could result in an unsafe installation. 4.) Before installing Model G, the masonry chimney should be thoroughly inspected for any damage such as cracks, void areas, missing bricks or mortar and other defects. Damaged areas should be repaired prior to installation. Care should also be taken to ensure that the masonry chimney is clean and free from any buildup of creosote. Consult a certified Chimney Sweep if necessary. 5.) Installed in an existing masonry chimney under the terms of the CAN/ ULC-S635 Listing and in masonry chimneys under the terms of the UL1777 Listing, Model G liner requires only sufficient space within the chimney to accommodate the installation. The minimum internal dimensions necessary for installation will be the liner inside diameter plus approximately 2, to allow for the V-Bands that connect the individual lengths together. (eg. - A 16 Model G liner will require an approximate 18 minimum inside opening within an existing chimney.) 6.) If Model G is to be used to line an existing factory-built chimney or vent, such chimney / vent must be thoroughly cleaned and checked for structural defects. Such chimney / vent should also be checked to insure that all parts (supports, radiation shields, firestops, etc.) specified by the chimney / vent manufacturer are installed and that the air space clearances between the chimney or vent exterior casing and Page 1

combustible material is in accordance with the installation instructions. 7.) Correct sizing of Model G requires reference to the appliance installation instructions and / or conducting a specific sizing assessment. Correct liner size is important for proper venting. Correct sizing is also particularly important when venting appliances with low flue gas temperatures in geographical areas that experience sustained low ambient temperature because they may be susceptible to icing / blockage at the outlet and associated equipment and / or personal safety concerns due to improper appliance venting. Unless a specific sizing assessment is conducted and confirms adequate capacity, no portion of the liner should ever be smaller in diameter than the outlet of the appliance it serves. 8.) Selkirk Model G liner is Listed per CAN/ ULC- S635 as a Class 3 Lining System for use in existing masonry or factory-built chimneys and may be used with oil, gas or solid fuel-fired appliances where the temperature of the flue gas products does not normally exceed 650 O C (1200 O F). Many common gas, oil or solid fuel fired boilers, hot water heaters, warm air furnaces and some types of process heating or other specialty equipment including certain engine exhausts operate within such flue gas temperature range. Per its UL1777 Listing, Model G is limited to gas fired equipment applications for flue gas temperatures up to 570 O F continuous and short term exposure up to 1700 O F. If there is any question concerning whether Model G is appropriate for use with certain equipment, contact Selkirk Technical Support staff for assistance. 9.) Model G chimney liner should be sized in a manner to reduce excessive amounts of condensation of moisture, creosote build-up and weak draft. These factors are often consequences of an oversized chimney and can lead to a reduced service life for the system attributable to excessive condensation and premature corrosion of the system compared to a properly sized system. For similar reasons, oversized chimneys used on wood burning appliances can lead to excessive creosote buildup within the flue. Weak draft can lead to operational problems and reduced combustion efficiencies of the appliances. 10.) If Model G is also used as a connector between the appliance and the masonry chimney being lined, treat Model G as a single wall connector and follow local code requirements for minimum airspace clearance from combustibles to single wall connectors. If the connector penetrates a combustible wall between the appliance and the inlet to the chimney, follow local code requirements for passing such single wall connector through the wall and / or use a safety certified "Wall Pass-Through Device" for such purpose. 11.) The maximum height from Model G will depend upon the diameter of the system being installed and the method of supporting the Model G. See the main installation instructions for support options and use the maximum height limitations specified for Model G. 12.) At locations where Model G extends above the existing chimney, a flashing or cover plate (may be generic) is recommended to prevent moisture, debris, etc. from entering the area around the liner. The area surrounding the Model G within the chimney may include an insulating material only if such insulating material is certified for use with Class 3 (all fuel) chimney liner systems and / or is otherwise acceptable to the local code authority. 13.) Model G liner should extend a minimum of 1 above the masonry chimney in which it is installed. Follow local code requirements for minimum spacing requirements from chimney terminations to surrounding structures. 14.) A Stack Cap or other Selkirk Model PS termination cap option is recommended for use with Model G to reduce moisture access to the inside of the flue. Listed rain caps with bird screens or spark arresters are necessary and / or required in some areas, but may be susceptible to blockage through freezing moisture in areas of low ambient temperature. Consult the authority having jurisdiction for requirements in your area. 15.) Inclined portions of the Model G liner system are generally not recommended but can be accommodated with elbows, if there is sufficient access / room for the installation to be made. In such instance, inclined portions of the system should not exceed 30 O from vertical. Portions of Model Page 2

G used as a connector system (between the appliance outlet and the inlet to the Model G liner / chimney) may be offset virtually horizontal with minimal slope required as per local code. 16.) Whereas the UL1777 and CAN/ULC S635 chimney liner standard contains no specifications for evaluating chimney lining systems for use in positive internal pressure applications, when used as the internal flue liner of Model PS and IPS, Model G is safety certified for use in positive internal pressure applications of 15 KPa (60 w.c.). Therefore Model G may be found suitable by the local code authority for use in positive internal pressure applications. 17.) Model G chimney liner system may be intermixed with Models PS and IPS chimney system components as part of an engineered venting system, assuming the proper associated airspace clearances-tocombustibles, transitions, supports, etc. are used for the various portions of the system. Contact Selkirk for additional information on combination / engineered venting systems incorporating mixed system usage. 18.) POSTING OF NOTICES: Upon completion of installation and before the system is put into operation a Notice should be posted in the appliance room, near the outlet of the appliance. This Notice should contain, as a minimum, the information shown in Fig. 3. GENERAL MAINTENANCE CONSIDERATIONS: 1) Selkirk Model G chimney liner systems should be inspected (and cleaned if necessary) periodically (at least once per year) during the course of use. More frequent inspections are appropriate during the first period of use in order to gauge the tendency for any accumulations that may need to be removed. Later, as inspections and cleaning data has been gathered over a period of time, it may be appropriate to reduce the frequency. 2) Failure to inspect and clean this chimney liner could result in premature corrosion, the buildup of dangerous deposits within the lining system (See Creosote below) and / or other, potentially dangerous, operational problems. 3) Access for inspection and cleaning. Depending upon the system layout, Model G liner can be accessed from the top by removal of the cap, and / or at the base by removal of a portion of the connector system. See main instructions for information on joining / separating system parts. 4) Selkirk Model G liner may be cleaned with conventional chimney brushes of the correct same, nominal diameter as the flue. 5) Creosote - Formation and Need for Removal: When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the liner. When ignited, this creosote makes an extremely hot fire. The liner should be inspected periodically during the heating season to determine if a creosote build-up has occurred. If a significant layer of creosote has accumulated (3 mm or more) it should be removed to reduce the risk of a chimney fire." If you have any questions concerning this Model chimney liner and its use / application or qualifications, contact Selkirk via the contact information included at the end of this document. Section 1 General Installation Guidelines 1) Determine the location of the point where the vent system will penetrate the masonry wall (the position of the appliance, likely, will have a large impact on this) and prepare an opening through the masonry and any existing liner, large enough to easily accommodate the "Pass Through Device" which Model G will extend through. The opening should be large enough to allow easy access to the Model G for purposes of Plate Support attachment and positioning. It may be necessary to prepare another opening further up for purposes of installing Half or Full Rings for guided support. Consult general installation instructions for proper "F" and "S" dimensions. S dimension limitations may be extended or eliminated depending upon the spacing between the Model G and inside face of the masonry chimney. Consult Selkirk for further specifics. 2) Have the intended support bracing installed at the prepared opening such that when the Plate Support comes to rest on the bracing, the centerline of the snout of the Tee which Page 3

attaches to the Plate Support should end up near the centerline of the prepared opening. 3) Determine the overall length of the system by measuring from the prepared opening to a point 610mm (2 feet) above the top of the masonry chimney. Add the distance from the appliance outlet to the prepared opening accounting for any bends. 4) Select lengths of pipe necessary to accommodate total required length determined by step 3. 5) Gather all necessary component parts and locate them near the top of the masonry chimney. This should consist of a Manifold Tee with Tee Cap, Plate Support, Flashing, Storm Collar, Stack Cap, Sealant and the necessary pipe lengths with V-Bands, along with all appropriate safety related equipment. 6) (Assuming there is sufficient space around the G liner and the inside of the chimney to accommodate the plate support) attach the outlet of Tee to the inlet end of a length of pipe, clamp the Plate Support around the V- Band and start lowering it down the chimney flue. Add lengths of pipe as necessary. See Section 2 for details. In the event that there is insufficient space to pre-install the plate support to the bottom of the liner assembly before lowering it down through the chimney, it may need to be installed at the base, first, then mated to the bottom end of the liner assembly as it is lowered into place. 7) The Plate Support should come to rest on existing bracing which should already be installed. The tee snout should be at the prepared opening with the top portion of the Model G at least 12 (610mm) above the top of the masonry chimney. Bolt the Plate Support to the support bracing. 8) Add lengths of pipe necessary to extend from the tee snout to the outlet of the appliance. 9) After the system is connected to the appliance and checked for proper installation, including clearances to combustible surfaces, proper support and proper component parts, fill in the void area around the penetration with a noncombustible filler such as ceramic fiber insulation. 11) Weatherize the system at the top with the use of a Flashing, Storm Collar, Stack Cap (or otherwise acceptable cap) and silicone sealant. The Flashing should be attached to the top of the masonry chimney with the use of masonry fasteners. Sealant should be applied around the entire perimeter of the Support Plate or Flashing at the point where it makes contact with the top of the masonry chimney. It should also be applied around the top edge of the Storm collar. Section 2 - PIPE AND FITTING JOINT ASSEMBLY 1) Clean all pipe flanges and V-Band inner surfaces with an appropriate organic solvent. 2) Bring parallel flanges together. 3) Apply P600 or P-2000 sealant (as appropriate for the application) to the inner groove of the V-Band. 4) Clamp the V-Band around the flanges using the end clamp hardware. Note: Light tapping with a wooden mallet or similar device all around the V-Band while tightening the clamp helps to align and pull flanges together. See Fig. 2 10) A Trim Collar (may be generic) should be installed to give a finished appearance if desired. Page 4

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. THEY INCLUDE IMPORTANT USE AND MAINTENANCE INFORMATION FOR MODEL G CHIMNEY LINER. Fig. 3 Recommended Notice for posting near appliance outlet. NOTICE: The chimney liner to which this appliance is attached is Listed per CAN/ ULC-S635 as a Class 3 Lining System for use in existing masonry or factory-built chimneys and vents. It may be used with oil, gas or solid fuel-fired equipment where the temperature of the flue gas products does not normally exceed 650 O C (1200 O F). The chimney liner to which this appliance is attached is Listed per UL1777 for use with gas fired equipment for flue gas temperatures up to 570 O F continuous and short term exposure up to 1700 O F. Under certain low ambient temperature conditions, some chimney caps can be susceptible to ice buildup. Check cap for ice buildup under such conditions and remove ice if necessary before using the chimney. Date of installation: (Fill in) Chimney Liner is Model G, manufactured by Selkirk SELKIRK CORP 5030 Corporate Exchange Blvd SE, Grand Rapids, MI 49512 (ph: 800-848-2149) www.selkirkcommercial.com Rev. 11/21/13 Page 5