Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact arrangement to provide high voltage DC capability and high switching performance. Designed for plug-in mounting in distribution rail X 0-S0606J (see section 7) or terminal blocks 3-P0-Si-0005 and 63-P0-Si-0005. Approved to CBE standard EN 60934 (IEC 60934). Typical applications Communications systems, power supplies, process control equipment. Ordering information Type No. 0 thermal-magnetic circuit breaker, toggle operated Mounting S9 socket or panel mounting with M3 thread Terminal design P9 blade terminals, for distribution rails X0-S.. and X0-K.. Characteristic curve M medium delay Style 40033 single pole with two chambers (one chamber protected only), break contact Si Current ratings...5 A 0 - S9 - P9 M - 40033-0 A ordering example Standard current ratings and typical internal resistance values Current rating (A).0 0.5 3 0.3 4 0.07 6 0.04 8 0.0 0 0.0 6 < 0.0 5* < 0.0 *80% I N continuous load Internal resistance (Ω) Technical data Voltage rating Current rating range Auxiliary circuit Typical life Ambient temperature 0-S9-P9M-40033-...A AC V; DC 65V...5 A A, AC 40 V/DC 65 V > 0,000 operations at x I N > 0,000 operations mechanical -30 C... (-...+40 F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664A) withstand voltage degree.5 kv reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V main to aux. circuit AC,0 V Insulation resistance > 00 MΩ (DC 0 V) Interrupting capacity I cn AC V,000 A cosϕ = 0.8 DC 65 V,000 A L/R = 4 ms Degree of protection operating area IP30 (IEC 6059/DIN 400) terminal area IP00 Vibration 5 g (57-0 Hz), ± 0.38 mm (0-57 Hz); to IEC 60068--6, test Fc 0 frequency cycles/axis Shock 5 g (ms) directions,, 3, 4, 5 0 g ( ms) direction 6 to IEC 60068--7, test Ea Corrosion 96 hours in 5 % salt mist to IEC 60068--, test Ka Humidity 40 hours at 95 % RH to IEC 60068--3, test Ca Mass approx. 80 g Approvals Authority Voltage ratings Current ratings VDE (EN 60934) AC V, DC 65 V...5 A 05/06 www.e-t-a.com
0 0.787.97 Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Dimensions Internal connection diagrams 3.6.4 unit line line.38 5 5 OFF ON 9.748 43.69.47 68.68 5.984 8.709.5.49 unit (k) OFF position Shock directions (k) ON position k 0..083.6.97 3.6 blade terminals DIN 4644-A6.3-0.8 (QC.) operating area (reinforced insulation) 0 5.5.453 3 6.8.68.5.49 mounting thread M3 max. screw length 5.8 mm (.8 in.) tightening torque max. 0.5 Nm 5 6 4 unit II unit I 8A 9.354 6.630.5.49 Installation drawing Typical time/current characteristics See page 33 k mounting area (standard insulation) This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. www.e-t-a.com 05/06
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40005-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact arrangement to provide high voltage DC capability and high switching performance. Designed for plug-in mounting in distribution rail X 0-S0606J (see section 7) or terminal blocks 3-P0-Si-0005 and 63-P0-Si-0005. Approved to CBE standard EN 60934 (IEC 60934). Typical applications Communications systems, power supplies, process control equipment. Ordering information Type No. 0 thermal-magnetic circuit breaker, toggle operated Mounting S9 socket or panel mounting with M3 thread Terminal design P9 blade terminals, for distribution rails X0-S.. and X0-K.. Characteristic curve M medium delay Style 40005 single pole with two chambers (protected), break contact Si Current ratings 0.4...5 A 0 - S9 - P9 M - 40005-0 A ordering example Standard current ratings and typical internal resistance values Current Internal Current Internal rating (A) resistance (Ω) rating (A) resistance (Ω) 0.4 6.87 6 0.09 0.65.96 8 0.03.84 0 0.03.6 0.75 0.0 0. 6 < 0.0.5 0.35 0* < 0.0 3 0.5 5* < 0.0 4 0.5 *80% I N continuous load Approvals Technical data Voltage rating Current rating range Auxiliary circuit Typical life Ambient temperature 0-S9-P9M-40005-...A AC V; DC 65V 0.4...5 A A, AC 40 V/DC 65 V > 0,000 operations at x I N > 0,000 operations mechanical -30 C... (-...+40 F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664A) withstand voltage degree.5 kv reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V main to aux. circuit AC,0 V Insulation resistance > 00 MΩ (DC 0 V) Interrupting capacity I cn AC V cosϕ = 0.8 0.4... A self-limiting.6...5 A,000 A DC 65 V L/R = 4 ms 0.4...4 A self-limiting 6...5 A 3,0 A Degree of protection operating area IP30 (IEC 6059/DIN 400) terminal area IP00 Vibration 5 g (57-0 Hz), ± 0.38 mm (0-57 Hz); to IEC 60068--6, test Fc 0 frequency cycles/axis Shock 5 g (ms) directions,, 3, 4, 5 0 g ( ms) direction 6 to IEC 60068--7, test Ea Corrosion 96 hours in 5 % salt mist to IEC 60068--, test Ka Humidity 40 hours at 95 % RH to IEC 60068--3, test Ca Mass approx. 80 g Authority Voltage ratings Current ratings VDE (EN 60934) AC V, DC 65 V 0.4...5A 05/06 www.e-t-a.com
0 0.787.97 Thermal-Magnetic Circuit Breaker 0-S9-P9M-40005-...A Dimensions Internal connection diagrams 3.6.4 unit LINE LINE 5 5.47 5.984 8.709 unit.38 OFF 9.748 43.69 ON 68.68.5.49 (k) OFF position Shock directions (k) ON position k 0.5.453 3..083.6.97 3.6 6.8.68.5.49 blade terminals DIN 4644-A6.3-0.8 (QC.) mounting thread M3 max. screw length 5.8 mm (.8 in.) tightening torque max. 0.5 Nm 5 6 4 unit II unit I 8A 9.354 6.630.5.49 Installation drawing Selective back-up fuses k operating area (reinforced insulation) 5 0 mounting area (standard insulation) Voltage Interrupting Selective to rating capacity NH fuse rating Current rating of 0-S9-PM-40005 35 A 6 A A A 60 V DC 3,0 A 63 A 0 A 80 A 5 A 00 A 5 A 35 A 3 A A 8 A V AC,000 A 63 A 0 A 80 A 5 A 00 A 5 A NH fuse according to VDE 0636, part (IEC 69) NH fuse = low voltage power fuse This is a metric design and millimeter dimensions take precedence ( mm ) inch www.e-t-a.com 05/06
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40005-...A Typical time/current characteristics 0.4 6 A AC 0000 000 +40 F +3 C - F 0.4 6 A DC 0000 000 +40 F +3 C - F 00 0 00 0 0. 0. 0.0 0.0 0.00 4 6 80 0 40 60 8000 0.00 4 6 80 0 40 60 8000 8 5 A AC 0000 000 +40 F +3 C - F 8 5 A DC 0000 000 +40 F +3 C - F 00 00 0 0 0. 0. 0.0 0.0 0.00 4 6 80 0 40 60 8000 0.00 4 6 80 0 40 60 8000 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 Technical information. Ambient temperature F - -4 +4 +3 +73.4 +86 +04 + +40 C -30-0 -0 0 +3 +30 +40 + +60 Derating factor 0.76 0.79 0.83 0.88.04..9.9 05/06 www.e-t-a.com
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40005-...A Accessories Mounting sockets 3-P0-Si-0005 7.4.9 64.5 V E-T-A Typ 3 Gr. C 5.984 4.4.73 (k) polarized blade terminals DIN 4644-A6.3-0.8 (QC.).97 57.4.6.5.49 63-P0-Si-0005 terminal coding plug.38.6 6.8 6.8.68.68 retaining clip Y 30 974 0 to special order..874.87 0 6.36 30.8.079 7.4.9 4.4.73 64.5 6 5 4 3 E-T-A Typ 63 Gr. C V.5.49.97 75.95 terminal.5 6.5.49.46.97 57.4.6.38.6 6.8 6.8.68.68 (k) polarized blade terminals DIN 4644-A6.3-0.8 (QC.) coding plug..874.87 6.36 30.8 0.079 Distribution rail X0-S06... see section 7. This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. www.e-t-a.com 05/06