Whale Gusher 10 Mk3 Pump BP3708 / BP3740 INSTALLATION & USER INSTRUCTIONS Thank you for purchasing this Whale product. For over 60 years Whale has led the way in the design and manufacturer of water and waste systems including:- plumbing, faucets, showers and pumps for low voltage applications. The company and its products have built a reputation for quality, reliability and innovation backed up by excellent customer service. For information on our full product range visit: www.whalepumps.com CONTENTS 1. Principles of Operation 2. Specification 3. Application 4. Warnings 5. Parts List 6. Optional Extras 7. Installation 8. Maintenance 9. Trouble Shooting 10. Winterising 11. Service Support Details 12. EU Declaration of Conformity 13. Patents and Trademarks 14. Warranty LIST OF IMAGES Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Through deck installation Incorrect installation Typical installation diagram Mounting arrangements for a standard model Dimensions Discharge point is well above the water line Deck fitting for Gusher Pumps (Half sectional elevation of deck fitting, pump and bracket) Exploded diagram Read the following carefully before installation To the Fitter: Check that the product is suitable for the intended application. Follow these installation instructions and ensure all relevant personnel read the points listed below. Also ensure that these operating instructions are passed on to the end user. The manufacturer cannot be held responsible for claims arising from incorrect installation, unauthorised modification or misuse of the product. To the User: Read the following instructions carefully. 1
1. PRINCIPLES OF OPERATION This bilge pump is designed to exhaust standing water only. Manufactured from durable diecast alloy to withstand tough marine conditions. 2. SPECIFICATION Model On Deck / Bulkhead Thru Deck / Bulkhead (includes deck plate) Product Code BP3708 BP3740 Hose Connections 38 mm (1 1/2 ) Smooth Hose Connections Weight Materials Materials In Contact With Fluid Service Kit Maximum Suction Lift Maximum Discharge Head 2.3 kg (5 lbs) Pump Body: Marine Grade LM6 Aluminium Alloy (epoxy coated). Diaphragm: Neoprene (Nitrile option available) Fasteners: Stainless Steel Marine Grade LM6 Aluminium Alloy (epoxy coated). Neoprene, Nitrile, Stainless Steel AK3706 - Neoprene Parts AK3714 - Nitrile Parts for Oil & Diesel Contains: Diaphragms, Valves, Gasket 4 m (13.5ft) 4 m (13.5ft) Performance Data BP3708 / BP3740 BP3708 / BP3740 Suction Lift 1 m (3 ft) 2 m (6 ft) Discharge Head 0.5 m (1.5 ft) 0.5 m (1.5 ft) 45 Strokes per Minute 41 ltrs (11 US gals) 41 ltrs (11 US gals) 70 Strokes per Minute 65 ltrs (17 US gals) 65 ltrs (17 US gals) 3. APPLICATION This bilge pump is suitable as a primary bilge pump on boats equal to or greater than 12m (40ft). Output capacity depends on installation, conditions during use and pumping rate. Users should be aware that capacity may not be sufficient to cope with rapid influx of water. If it is intended for any other purpose or with any other liquid, it is the users responsibility to ensure that the pump is suitable for the intended use and, in particular, that the materials are fully compatible with the liquids to be used. 4. WARNINGS The pump is designed to evacuate standing bilge water only. Bilge pump capacities may not be sufficient to prevent flooding from rapid accumulation of water due to storms, rough weather and/ or rapid leaks created by hull damage and or unsafe navigational conditions. Fitting an inlet strainer will ensure the maximum efficiency of the pump. This pump is not for use in systems evacuating water through a skin fitting or seacock below the waterline. All pipework must contain a corectly installed anti-syphon valve/loop (next page see Fig 3 - Typical installation diagram). Not suitable for pumping flammable liquids, diesel, chemicals etc. Suitable for bilge water only. With all applications, it is important that a system of safe working practice is applied to installation, use and maintenance. Ensure the waste water system is drained before installation. In order to securely fasten the unit, ensure that the mounting surface is a minimum thickness of 18mm (45/64") as shown in Fig. 4 NOTE Do not screw directly to the hull - must be mounted on a bulkhead or on an additional board. 2
5. PARTS LIST 1 x Mk3 Gusher 10 pump 1 x Stainless steel handle (BP3740 includes deckplate) 1 x Mounting hole template 6. OPTIONAL EXTRAS AS4405 - Spare handle DP3804 - Metal deckplate & lid DP8904 - Plastic deck plate SB5865 - Strum box (top entry) SB4222 - Strum box (side entry) 7. INSTALLATION Fig. 1 Through deck installation Fig. 2 Incorrect installation Fig 3 - Typical installation diagram Please note that incorrect installation may invalidate the warranty. LOCATION Choose a position to mount the pump that is dry and away from standing water and is free from obstacles, where the pump can be operated efficiently and comfortably. Ensure that the pump is installed to allow easy access for servicing. Avoid installation locations which require a cockpit locker to be opened in order to operate the pump. To ensure good priming and flow: Avoid sharp bends in pipework. Fit a Whale strumbox / strainer part number SB4222 / SB5865 which prevents the end of the hose sucking against a flat surface and allows the water level to be reduced to a minimum. To minimise pumping effort, site the pump halfway (in height) between the strumbox / strainer and hull outlet. Mount in a position with the shortest run lengths possible. Use a reinforced hose on inlet to prevent collapsing during suction. The Gusher 10 is designed for mounting on deck / bulkhead (BP3708), or through deck / bulkhead (BP3740). The handle can be fixed on four different positions relative to the inlet and outlet (see Fig. 4). Fig. 4 Mounting arrangements for a standard model To Reposition Handle: (a) Slacken wormdrive clip and remove diaphragm (b) Undo the bolts from bracket and rotate body to new position relative to the fork and diaphragm. Note: Inlet and outlet are always at 180 degrees to each other (c) Reassemble bolts, washers and securing brushes in bracket and tighten 3
For Mounting On Deck/Bulkhead: 1. Use pump as a template, mark off and drill four 1/4 (6mm) holes. 2. Check flow direction and secure the pump with 1/4 (6mm) bolts. 3. Attach 1 1/2 (38mm) smooth bore reinforced hose with stainless steel worm drive hose clips. Tighten to prevent air leaks. 4. With thru-hull discharge, make sure that the discharge point is above the maximum heeled water line. 5. Check the installation for air leaks, correct priming and discharge. For Mounting Underdeck or Thru Deck/Bulkhead Two deckplates available - see accessories Fig. 5 Dimensions Fig. 6 Discharge point 1. Using template mark off the 6 holes for the mounting and cut out the hole for the pump handle. To preserve the gaiter, ensure the top edge of this hole has no sharp edges. Fig. 7 Deck fitting for Gusher Pumps (Half sectional elevation of deck fitting, pump and bracket) 2. Minimum deck thickness required is 1/4 (6mm). For thinner decks use a backing plate of suitable thickness so that the backing plate plus the deck is at least the minimum thickness and no greater than 1 (25mm). Bond the backing plate to the deck. If using Deck plate DP3804 the minimum deck thickness is ¹ (13mm). 3. Position the pump under deck and check flow direction. Work the rubber gaiter up through the hole until its flange rests on the deck. Secure the 6 1/4 (6mm) countersunk mounting screws provided. 4. As points 3-5 of previous instructions. OPERATION The Gusher 10 ensures efficient throughput with an easy pumping action. Full even strokes will obtain the best results. The detachable handle is fitted with a lanyard and should be safely secured close to the pump. Performance data is based on factory tests and is typical of what may reasonably be achieved. Actual performance may vary depending on installation and operating conditions. 4
8. MAINTENANCE This Whale Gusher 10 is designed to only require minimal maintenance. WARNING: Before servicing pump, drain water from system. Inspection: The diaphragms and inlet valves are held in place by the groove in the pump body and cover. Following inspection, ensure that they are seated properly in the grooves before tightening the covers in place. Regular inspection of the pump is recommended. Access to the pump chamber is quick and easy, requiring no tools. Rubber components should be replaced if worn or every three years regardless of condition. During periodic shipboard inspections, the bilge pump should be visually inspected to confirm parts are in good condition, especially rubber parts and mounting arrangements. The pump should be operated to show that it pumps water efficiently. Screw Bridge piece Valve Body Handle knob Tolerance ring Diaphragm Clamping plate Nut Bolt M6 Securing brush Handle Tube Worm Drive Clip Nut Washer Lanyard Gasket Bracket Fulcrum brush and sleeve Buffer Fork liner Clamping plate Screw Valve plate Fork Label Fulcrum brush and sleeve Locknut Eye Bolt Bolt Washer Fig. 8 Exploded diagram Annual Checks Whale advise that the boat's plumbing system is checked annually for leaks and obstructions. Optimal Performance Ensure this product is clear of debris It is recommended a service kit is kept on board. These are available from your local chandlery. Changing the Diaphragm and Valves 1. Slacken and remove the wormdrive clip to release the diaphragm. 2. Release diaphragm nut and remove diaphragm plates and diaphragm. 3. Replace old inlet and outlet valves. Note: both inlet and outlet valves are same shape. The service kits contain two sets of valves - round ones for the MK 2 pump and square valves for the MK 3 pump. DO NOT mix the valve types! 4. Replace diaphragm and tighten wormclip in position and test for correct priming and discharge. 5
9. TROUBLE SHOOTING Fails to prime Inlet hose fault Diaphragm failure Debris in the body of the pump Inlet and/or outlet valve failure Check inlet hose connection is airtight, free from blockages and does not collapse during suction stroke If damaged replace all rubber parts (see Service kits) May not prevent its operation but should be removed to prevent damage Inspect and remove any debris. If damaged replace (see Service kits) 10. WINTERISING Note: Annually at the end of the season, fully drain all water in the pipework and pump chamber. Whale cannot guarantee warranty if the system is not fully drained for winterising. 11. SERVICE SUPPORT DETAILS Service kits available: AK3706 and AK3714 For installation or service advice please contact Whale Customer Support: Tel: +44 (0)28 9127 0531 Email: info@whalepumps.com www.whalepumps.com USA Tel: 1 802 367 1091 USA Fax: 1 802 367 1095 Email USA: usasales@whalepumps.com www.whalepumps.com 12. DECLARATION OF CONFORMITY, STANDARDS AND APPROVALS This product complies with all relevant European directives and standards. Please contact Whale if further details are required Manufacturer s Declaration We hereby declare, under our sole responsibility, that the enclosed equipment complies with the international standard EN ISO 15083:2003 - Small craft-bilge pumping systems. Engineering Director Date: October 2016 13. PATENTS AND TRADEMARKS WHALE and GUSHER are registered trademarks of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale. 14. WARRANTY This Whale product is covered by a 5 year warranty. Please see the enclosed document for details of our Statement of Limited Warranty. Copyright Whale 2017 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE is a registered trademark of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale. Whale s policy is one of continuous improvement and we reserve the right to change specifications without prior notice. Illustrations are for guidance purposes only. Neither the accuracy nor completeness of the information contained in any Product brochure is guaranteed by the Company and may be subject to change at its sole discretion. Please note that by contacting Whale Support you will be indicating your consent to receiving product updates, recall information, help guides and appropriate marketing messages from us via post, email or telephone unless you indicated an objection to receiving such messages. 6
Munster Simms Engineering Ltd. 2 Enterprise Road, Bangor, N. Ireland BT19 7TA Tel: +44 (0)28 9127 0531 whalepumps.com info@whalepumps.com Ref No: db_jw_g10_180.07_v3_0217