INSTRUCTIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS 2015 & 2016

Similar documents
INSTRUCTIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS 2015 & 2016

LAYCOCK SYSTEMS, INC N. 43 rd Street Tampa, FL

LAYCOCK SYSTEMS, INC North 43rd Street, Tampa, FL 33605

TOOLS TOOLS INSTRUCTIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS

INSTRUCTIONS BENCH TYPE COIL WINDER DRIVES MODELS: 2057, 2067, AND 2069

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

product manual H-3620, H-3624, H-3625 Flow Table with Mold

GBP784B INSTALLATION TOOL

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

FAN-STOP INSTRUCTION MANUAL

POWER PINNER RAPID FIRE 7005 RF OPERATOR S MANUAL

Electric Actuator Installation, Operation & Maintenance Manual

Automotive Air Conditioning Manifold Gauge Sets

DeZURIK TEN-POSITION LEVER MANUAL ACTUATOR

TESCO THE EASTERN SPECIALTY COMPANY Date: 05/04/15 Canal Street and Jefferson Avenue Bristol, PA 19007

Lift N Go [Model 210] Electric Carrier For use with power chairs & scooters Installation Guide & Owners Manual

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

BLACKBIRD INSTALLATION SUPPLEMENT

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

BLACKBIRD INSTALLATION SUPPLEMENT

BLACKBIRD INSTALLATION SUPPLEMENT

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

OPERATING MANUAL HAZARDOUS-DUTY PUMP DRIVE

CABINET REEL OPERATING INSTRUCTIONS

6300 Series Owner/Operator Manual

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Service Instructions. Syntron Light-Capacity Electromagnetic Model: F-T01-A DF-T01-A

WARRANTY INFORMATION...

Geotech Filter Holders

MODEL 660 AUTOMATIC FASTENING CENTER OPERATOR S MANUAL

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Installation. Installation. 12. System Diagram... 10

Rheometer Calibration Fixture Instruction Manual Model 280 & 286

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

DeZURIK R1 POWERRAC ACTUATOR ON 1/2-3" PEC ECCENTRIC VALVES

Phase Sequence Tester

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

DIRACT BRAKES 70 SERIES 4 POST BRAKE INSTRUCTIONS

3-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

RESISTIVITY MONITOR/CONTROLLERS

MOTORTRONICS Solid State AC Motor Control

Transfer Switch GPTS 30

80 Series 4 Post Brake Instructions

5-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

& r"1aintef~ance. Your KENBAK-l computer is a quality instrument which is. should expect months or years of operation without significant

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991

CRD600 Automatic Fitting Inserter

1500 Series Roll Off Hoist. Owner s Manual (5-06)

User Guide. Model Insulation Tester / Megohmmeter. Introduction

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

The Da-Lite Difference.

US208S Scooter / Power Chair Carrier Lift N Go 117 Mini Electric Lift Electric Tote & 130 Swing Away Installation Guide & Owners Manual

"WHERE TUBING AND FITTINGS COME TOGETHER"

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

BLACKBIRD INSTALLATION SUPPLEMENT

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

MAGNAGLIDE AIR OPERATOR VERTICAL MOUNT

HIPSTER'S ALUMINUM POWERGLIDE TRANSBRAKE (P/N: 12748A) CAUTION

CSA CERTIFIED Conforms to UL 507

1x - Power Cord^ - (May vary slightly by color and/or length) 1x - Hook-up Wire w/ Fork Ends* 1. General Specifications...2

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

CI 3000 Coil Inserter

FD Conveyor for FD 260 Tabber

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

On-A-Roll Lifter Instruction Manual for Standard Models Read Before Use!

32 quarts Transmission Allison HT 740 Automatic Fluid

BLAZER 9000 LUBE LIFT OPERATOR AND PARTS MANUAL

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

DeZURIK R1 AND R2 POWERRAC ACTUATORS

Installation and Maintenance Instructions JSE MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

KidWalk KidWalk II Dynamic Mobility System

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

MMR20. Instruction Manual for Operation & Maintenance. IB International. Ph:

Tech Note Truck 14 & 15.5 Twin Plate Cast Iron Type Installation Guidelines

Model 116 DPI Switch Installation and Operating Instructions

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems

INSTALLATION AND MAINTENANCE MANUAL

WARNING. Laser light is extremely bright and can potentially cause permanent eye damage or interfere with critical operations if improperly used.

The Da-Lite Difference.

Installation and Maintenance Instructions JSE1-0128MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

NECO Pumping Systems

Installation Manual TWM Performance Full replacement short shifter assembly Civic all trims and models

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Operating Instructions for the. In Line Conveyor System West Cabot Boulevard Langhorne, PA w w w.empire-airblast.

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

John Deere. MODEL: 440 Diesel Industrial Crawler JD-O-OMT73459

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

456 Series Hydra-Lift Drum Rollers Operator s Manual for Morse Hydra-Lift Drum Rollers 456 Series

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Transcription:

LAYCOCK SYSTEMS, INC. 1601 N. 43 rd Street Tampa, FL 33605-5937 LAYCOCK Phone: 813-248-3555, Fax: 813-242-0514 CROWN MOTOR E-Mail: sales@laycocksystems.com MOTOR WINDING Website: www.laycocksystems.com REPAIR TOOLS TOOLS INSTRUCTIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS 2015 & 2016 The Crown Heavy Duty Coil Winding Machine is self-contained, variable speed, power drive, designed for rapid production of all types of coils. It is designed for use with all Crown Coil Winding Heads, and other similar winding forms. Driven by a 1/2HP, 1750RPM Motor, and variable speed transmission, the output speed range may be varied from 40 to 400RPM. A maximum rated torque of 210 in-lbs is developed at high speed and approximately 775 in-lbs at the slow speed. CAUTION: DO NOT EXCEED RATED LOADS. INSTALLATION 1. Power requirements are 115VAC, 50/60Hz, single phase for Model 2015, and 230VAC, 50/60Hz, single phase for Model 2016. 2. The Machine should be set up allowing clearance for the swing on the winding heads and access to the motor compartment for maintenance. 3. DANGER: It is important that the machine be SECURELY BOLTED TO A FIRM FOUNDATION. Unless the unit is securely bolted, objectionable vibration will occur and the machine may PULL OVER when heavy loads are applied. Do not operate machine without side panels installed with all mounting screws. 4. The wire guide bar, for use in guiding the wire to be wound on the Crown Coil Winding Heads, is held in position by a clamp arrangement and two square head cap screws and protrudes from the hole in the upper right hand corner of the stand. It must be adjusted from its position in shipment so that the end-most portion is parallel to the Coil Winding Machine face plate shaft. CAUTION: Before using Machine, fill gear housing with three (3) quarts SAE #30 (2.8 liters), non-detergent oil. To fill, remove plug from top of gear housing. Replace plug before operating the unit. Requires air to operate the clutch and brake of the Unit. Connect air inlet supply line to a filter/regulator for maintenance free operation and long life. NOTE: DO NOT OPERATE MACHINE WITH MORE THAN 70 PSI (pounds per square inch). NOTE: MOTOR IS NOT THERMAL PROTECTED. THEREFORE, EXTERNAL OVERLOAD PROTECTION MUST BE PROVIDED BY USER. ALL ADJUSTMENTS HAVE BEEN MADE AT THE FACTORY.

OPERATION 1. Connect the machine to the proper power and air source. 2. To start machine, the ON Button must be depressed and the (round black knob) air release, located on the right side of the front panel must be pulled OUT. To operate the machine, foot switch must be depressed. For emergency stop before preset number is reached, release foot switch, machine will stop instantly. 3. Push IN the air release knob, turn the gear shift control on the front of the gear case to SLOW. (It may be necessary to rock the face Plate slightly when engaging the transmission). The gearshift control MUST NOT BE SHIFTED WHILE THE DRIVE SHAFT IS TURNING. The speed adjust crank on the front of the machine will allow adjusting variable speed ranges. gearshift in FAST range is 130-400RPM and Gearshift in SLOW range is 40-110RPM. Clockwise rotation of crank increases speed, counterclockwise rotation reduces speed. TURN ONLY WHILE MOTOR IS RUNNING. 4. Check the clutch and brake action in both the FAST and SLOW positions to see that they operate satisfactorily. 5. Counter counts up. Large numbers indicate number of turns. OPERATION OF COUNTER Counter has touch contacts, to operate counter press items indicated on Face. To enter the number of turns required: 1. Press PRESET #1 Button. Light at preset will light. 2. Press the number of turns desired. 3. Press the ENTER button. Display will disappear briefly and return indicating entry. 4. Press the COUNT button. Light at count will light and display will indicate zero. 5. Press the RESET button and unit is ready to operate. (Note: Counter is fuse protected and fuses are located inside the base on the left hand side. Power to the machine should be removed prior to changing fuses. Left hand cover must be removed to access fuses.) Always replace side panels before using machine to prevent housing collapse and eliminate excessive vibration. Counter has memory, which will hold preset number until changed. Foot switch may be released at any time before count is reached without disturbing the preset number. Example: Preset set for 15 turns. Foot switch is released at 8 turns, simply repress foot switch and Unit will continue to preset count. NOTE: When preset count is reached, unit will stop. Reset the counter to zero for the next set of coils. For manual operation, set preset number to zero, unit will count manually. When count is achieved, press RESET Button to reset counter. All functions set at the factory. Pressing the FUNCTION button accidentally will cause the display to disappear. Press the ENTER button to resume display. To insure proper set up of equipment, on both fast and slow speeds, set counter preset to approximately 4 turns, select speed and run through a cycle. As speeds of the coil winder are varied, the stopping position of the coil winding head may vary. Although the winder will always stop in the same position, it starts out from at a set speed and will accurately wind the number of turns required, the starting position of the winding head may not be desirable for the operator. To change the starting position of the coil winding head to a position desired, push in the air release knob, pull out the round knob (black) located behind the brake (right side of the gear box). Hold knob out and position the winding head to the desired starting position. Release the round black knob and pull out the air release knob and unit is ready to start winding.

6. When all checks have been completed and the unit appears to be operating satisfactorily, it is ready for use and the desired winding head can be mounted on the face plate. Be certain the winding head is securely fastened and centered on the face plate. 7. To use the guide bar, two extension spindles are also provided. The smaller one threads in the end of the guide bar and is intended for use when the CROWN "Midget" Coil Winder Head is mounted on the machine. The extra sleeve and spools provided with this head are slipped over the spindle and are in position to guide the wire while winding coil. The larger spindle slips over the end of the bar and is for use with the CROWN "Universal" Coil Winder Head. The extra spacers provided with this head are placed in proper position on this spindle to facilitate the winding of coils. The larger spindle can also be used with the CROWN "3-Phase" Coil Winding Head. MAINTENANCE: TO REPLACE BELT A. Disconnect power and air to winder machine. B. Remove belt guard. C. Remove left side panel. D. Remove air line to the clutch unit. E. Rotate clutch unit so belt will slide out. F. Replace belt - Dayton No. 4L-500 or equivalent (1/2" x 50") (Crown 807121). G. Rotate clutch unit and connect air Line to clutch unit. H. Replace left side panel and belt guard. When replacing panels start all screws before tightening, to property align holes. DANGER: ALWAYS REPLACE SIDE PANELS BEFORE USING MACHINE TO PREVENT COLLAPSE AND ELIMINATE EXCESSIVE VIBRATION. I. Reconnect power and air to winder machine. LUBRICATION: GEAR CASE Before draining and flushing gear case, be sure to provide a gutter or other suitable drainage path. Drain and flush gear case after every 1500 hours of operation. Use ONLY SAE #30 (2.8 liters), nondetergent oil. Three (3) quarts of oil are required to fill the case. WARRANTY Crown's Motor Repair Equipment is warranted to the original owner against defects in materials and workmanship for ninety (90) days from date of purchase. Any part found to be defective (except by overloading, misuse, neglect, fire, accident, tampering with by unauthorized serviceman, or other cause beyond the manufacturer's control), will be replaced or repaired free of charge.

Find No. Part Number Part List for Figure # 1 Part Name No. Req. 6 2 4 3 9 Automatic Stop Model: 2015 & 2016 7 1 FIGURE 1 8 5 INPUT SHAFT 10 11 13 20 17 19 12 18 15 16 13 21 10 10 INTERMEDIATE SHAFT 14 12 22 33 20 25 35 27 26 24 28 30 34 29 10 OUTPUT SHAFT 32 31 41 23 36 40 39 38 37

Find No. Part Number Part List for Figure # 2 Part Name No. Req. 63 59 Automatic Stop Model: 2015 & 2016 43 FIGURE 2 51 54 56 49 44 50 52 63 60 58 48 47 55 53 46 60 43 57 61 45 72 66 69 67 64 68 46 65 73 71 87 73 41 38 40 39

Automatic Stop Model: 2015 & 2016 79 FIGURE 3 85 86 80 43 76 90 91 92 93 111 116 114 TO COUNTER SHIELDED CABLE 110 TO AIR CLLUTCH/BRAKE 115 111 82 78 75 77 89 94 99 100 114 115 89 115 109 113 102 81 83 84 88 117 74 95 96 97 98 122 OR 123 101 118 74 104 105 106 121 120 103 119 116 108 107 87

SPECIFICATIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS 2015 and 2016 Primary power: Model #2015: 115VAC, 60Hz, 1 phase. Model #2016: 230VAC, 60Hz, 1 phase. Construction (Packaging): Heavy gauge steel Base, corrosion protected. Cast aluminum gear housing with steel spur gears. Two (2) speed gear in housing for maximum torque. (210 in-lbs in fast speed, 775 in-lbs in slow speed) Controls: All controls are at the operators finger tips. Speed is variable form 40-400 RPM. (Slow speed = 40-110 RPM, Fast speed = 110-400 RPM). Operation: Preset counter to number of turns required, press foot switch, machine runs to preset number and stops instantly when preset number is reached. Release foot switch and press reset to zero. Unit will be ready for the next coil. (For operator safety, in case of an emergency, the machine stops instantly when the Foot Switch is released). Machine comes equipped with a 10" face plate. The output shaft is center tapped for 1/2" -3 NC thread to allow attachments. Spare parts: Enclosures: To be recommended on request. Contact Factory. Operating instructions.