SOLNOI VLVS no voltage release (lever type) manual reset construction 3/8 to N NO 3 2 3/2 Series 308 TURS Lever type Manual Reset function which means that the valve has to be energized as well as manually operated before it stays in the "latched" position The No Voltage Release (NVR) function will make sure that the valve trips when deenergized The solenoid valves are recommended for 3/2 or 4/2 way pilot applications with high flow and wide pressure ranges Stainless steel or brass bodied valves with stainless steel internal parts The use of first class materials and thorough valve testing ensure a high reliability and a long service life The solenoid valve satisfy all relevant irectives GNRL ifferential pressure Maximum viscosity Response times 0 7 bar [ bar = 00kPa] 65cST (mm 2 /s) 75 00 ms fluids ( ) temperature range seal material ( ) air, inert gas 40 to + 60 NR (nitrile) MTRILS IN ONTT WITH LUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified rass body ody rass ore tube Stainless steel ore and plugnut Stainless steel Springs Stainless steel Seals NR isc and poppets NR Seat rass P MP RP 0,4W,7W Not vailable Not vailable 20W23W Low Reduced Medium asic POWR LVLS cold electrical holding values (watt) SPIITIONS operating pressure flow prefix optional solenoids pipe orifice differential (bar) basic coefficient catalogue size size level Kv min. max. (PS) NM TX / Ix IP65 number air ( ) 7&9 x d x e mb x mb Npt (mm) (m 3 /h) (l/min) ~/= ~/= N M PV S brass 3/2 N/NO Single solenoid, manual reset (NVR) 3/8 3/8 /2 /2 3/4 3/4 7,5 7,5 25,0 25,0 2,5 2,5 3,4 3,4 4,7 4,7,0,0 4,6 4,6 56,6 56,6 78,3 78,3 84,9 84,9 8,5 8,5 P P P P vailable feature vailable feature in only Not available (2) hoose for normally closed and G for normally open 30844/G () 30804/G () 308442/G () 308042/G () 308443/G () 308043/G () 308450/G () 308050/G () ll leaflets are available on: www.asco.com 80342G207/R0
SRIS 308 PRIX TL prefix description level 2 3 4 5 6 7 RP MP P M Waterproof IP66/67 Metal enclosure (N/I 600797,8 and 3)* T Threaded conduit/hole (M20 x,5) N lameproof luminium (N/I 60079, 600793)* S Solenoid with spade plug connector (N/I 60730) W P Waterproof IP67 Metal enclosure W S Waterproof IP67 36 SS enclosure W S M Waterproof IP66/67 36 SS enclosure (N/I 600797,8 and 3)* W S N lameproof 36L SS (N/I 60079, 600793)* T Threaded conduit (/2" NPT) H lass H attery charging circuit H T lass H High temperature X Other special constructions SUIX TL suffix description level 2 3 4 5 RP MP P N V PM (fluoroelastomer) and parts cleaned for oxygen service V PM (fluoroelastomer) O poxy coating on all external surfaces M Mounting bracket vailable feature vailable feature in only Not available * TX/Ix valves using these solenoids are approved according to N 3463 (non electrical) PROUT SLTION GUI STP Select basic catalogue number, including pipe thread indentification letter. Refer to the specifications table on page or 2. xample: 308042 STP 2 Select prefix (combination). Refer to the specifications table on page and the prefix table on page 2, respect the indicated level. xample: MT STP 3 Select suffix (combination) if required. Refer to the suffix table on page 2, respect the indicated level. xample: V STP 4 Select voltage. Refer to standard voltages on page 3. xample: 230V / 50Hz STP 5 inal catalogue / ordering number. xample: MT 308042 V 230V / 50 Hz ORRING XMPLS VLVS: S 308006 NV 24V / WS 308406 O 24V / WP 308006 NV 24V / OPTIONS & SSORIS catalogue number spare parts kit no. () ~ = mouting bracket no. prefix pipe thread basic number voltage suffix S 30804 S 308042 S 308043 S 308050 S 30844 S 308442 S 308443 S 308450 38534 38534 3459 306759 34590 3459 306759 34548 3459 306759 34590 3459 306759 () Standard prefixes/suffixes are also applicable to kits ll leaflets are available on: www.asco.com 03873000 03873000 03873000 03873000 03873000 03873000 03873000 03873000 ORRING XMPLS KITS: prefix basic number 38534 (2) WS 3459 WS 306759 (2) asic kit number applies to S coil construction 80342G207/R0 2
SRIS 308 XPLNTION O TMPRTUR RNGS O SOLNOI VLVS Valve temperature range Operator ambient temperature range Total temperature range LTRIL HRTRISTIS The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) The operator ambient temperature range is determined by the selected level and the safety code The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above oil insulation class onnector Spade plug onnector specification ISO 4400 (cable Ø 60 mm) lectrical safety I 335 Standard voltages: (=) 24V 48V; llowable voltage variation +0%, 5% (~) 24V 48V 5V 230V/50 Hz; Other voltages are available on request ratings operator ambient electrical replacement coil / kit prefix inrush holding hot/cold temperature enclosure safety code option ~ ~ = range (TS) protection ~ = (V) (V) (W) (W) ( ) () (N 60529) 230V/50 Hz 24V/ asic (P) S 240 43 20 6/23 40 to +75 N 60730 IP65, moulded 40052527 400625242 0/02 WP/WS 240 43 20 6/23 40 to +75 N 60730 IP67, steel/ss 40050527 400605242 03/04 N/WSN 240 43 20 6/23 60 to +60 II2G x d II Gb T4, II2 x tb III b IP66/67, alu./ss 40050527 400605242 Low Power () S,2,2,2,3/,3 40 to +75 N 60730 IP65, moulded 400929097 400929042 05/06 WP/WS,2,2,2,3/,3 40 to +75 N 60730 IP67, steel/ss 400930097 400930042 07/08 M/WSM,2,2,2,3/,3 40 to +60 II2G x e mb II Gb T6, II2 x tb III b IP66/67, steel/ss 400930097 400930042 07/08 () Temperature range can be limited by sealings (3 ) Multiple coil kits are available under TX/Ix, contact us (2) Refer to the dimensional drawings on page 4 Not available type (2) ITIONL OPTIONS Other pipe threads are available on request ompliance with UL, S and other local approvals available on request /2 NPT (prefix T ) and M20 x,5 (prefix T ) conduits (aluminium or 36 SS) available for steel solenoid housing Special mouldedin solid state components for peak voltage suppression and/or rectification (four diode bridge) INSTLLTION The solenoid valves have to be mounted vertically and in an upright position for best performance Multi language installation/maintenance instructions are included with each valve Threaded pipe connection identifier is = NPT (NSI.20.3) Other pipe threads are available on request Normally closed () and normally open contruction (G) have internal pilot connections and need bar min. operating pressure x e mb (prefix M ) execution: solenoid enclosure has a cable gland with integral strain relief for cables with an o.d. from 7 to 2 mm and is provided with an internal and external connection facility for an earthing or bonding conductor ll leaflets are available on: www.asco.com 3 80342G207/R0
SRIS 308 IMNSIONS (mm), WIGHT (kg) TYP 0: TYP 02: poxy moulded poxy moulded S: I 335 / ISO 4400 S: I 335 / ISO 4400 30804 / 04G / 042 / 042G 308043 / 043G / 050 / 050G G H K L TYP 03: TYP 04: Metal, epoxy coated / ISI 36 SS Metal, epoxy coated / ISI 36 SS WP / WS: I 335 WP / WS: I 335 G H 30804 / 04G / 042 / 042G 308043 / 043G / 050 / 050G G H KL TYP 05: TYP 06: poxy moulded poxy moulded S: I 335 / ISO 4400 S: I 335 / ISO 4400 G H 30844 / 44G / 442 / 442G 308443 / 443G / 450 / 450G GH K L ll leaflets are available on: www.asco.com G H 80342G207/R0 4
SRIS 308 IMNSIONS (mm), WIGHT (kg) TYP 07: TYP 08: Metal, epoxy coated / ISI 36 SS Metal, epoxy coated / ISI 36 SS WP / WS: I 335 WP / WS: I 335 M / WSM: N/I 600797+8+3 M / WSM: N/I 600797+8+3 30844 / 44G / 442 / 442G 308443 / 443G / 450 / 450G G H K L G H type prefix option level G H K L weight 0 S P 28 3 09 57 27 70 40 69 94 3,20 kg 02 S P 28 49 84 43 27 3 86 33 49 92 28 3,20 kg 03 WP, WS P 34 3 09 57 30 70 53 82 94 3,20 kg 04 WP, WS P 34 49 84 43 30 3 86 37 63 206 28 3,40 kg 05 S 28 3 09 57 53 70 40 69 94 3,40 kg 06 S 28 49 84 43 53 3 86 59 49 92 28 3,40 kg 07 WP, WS, M, WSM 34 3 09 57 66 70 53 82 94 3,40 kg 08 WP, WS, M, WSM 34 49 84 43 66 3 86 73 63 206 28 3,40 kg MOUNTING RKTS 42 Ø7, racket number : 03873000 Material : Zinc plated steel ll leaflets are available on: www.asco.com 5 80342G207/R0
SRIS 308 ll leaflets are available on: www.asco.com 6 PI0050G vailability, design and specifications are subject to change without notice. ll rights reserved. 80342G207/R0