FILTER Pure advantage. A flexible modular filter for particles and gas

Similar documents
FilterMax F. Modular dust collector with integrated pre-separator. Models

FilterMax F. Modular dust collector with integrated pre-separator

FilterMax F. Modular dust collector with integrated pre-separator

FilterMax DF. Modular dust multi purpose collector. Models

FilterMax DF. Modular dust multi purpose collector. Models

Bench Top Extraction Arms

FILTER MODULES FILTER MODULES APPLICATIONS

FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

LOCAL EXTRACTION Pure advantages. The ideal extractor for light industry and laboratory environments.

About Dustcontrol Filter Units

Extraction arm FX100 Original

EXHAUST EXTRACTOR Pure advantage. Exhaust rails for rescue vehicles

Smart Fume Extractor

INDUSTRY COMBO MF. Combined filter modules for fumes and particulate, combined composition of multiple modules to increase filtering capacity

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

FASTER ChemFAST. Laboratory Fume Cupboards PROTECTION, SAFETY, RELIABILITY. AND MORE.

Fume extractor is warranted for two years, parts and labor.

Механические фильтры MF серии шведской фирмы PlymoVent.

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

PRODUCT BROCHURE Cartridge Dust Collector DELBAG EuroJet. Compact solution for dust and smoke

Affordable portable filtration unit

Excelair. Every filter is created to perfection!

Looks like a safe because it s built like a safe. Gold Series. Farr APC. Gold Series Brochure. Air Pollution Control

Fume Extraction & Dust Collection

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Duct filter units. Duct HEPA filter units AKF

FUME DOESN T STAND A CHANCE

WSO Mist Collectors. cáäíê~íáçå=qéåüåçäçöó Ñçê=jáëí=`çääÉÅíáçå

FilterMax DF. Modular dust multi purpose collector

DUST COLLECTORS. Stronger. Better. CLEANER.

TOTALINE ELECTRONIC AIR CLEANERS

GEA Cartridge Dust Collector. EuroJet. Compact solution for dust and smoke. GEA Heat Exchangers / GEA Delbag Lufttechnik GmbH

Smart Fume Extractor

(ULT300-UM.x-HFM050) Technical Documentation

Splash-proof Terminal HEPA Filter

Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation.

LCP Cartridge Dust Collector

CONTROL UNITS VEHICLE EXHAUST GASES. Pure advantages

(ULT200-UM.x-HFM050) Technical Documentation

Fume Arms. AQC source capture equipment. Superior technology generating substantial operating savings. No internal adjustment

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853

ARM-EVAC 105. Central Filter Unit

quatroair.com AIR TECHNOLOGIES INC.

Owner s manual for installation, usage and maintenance

Product catalogue 2010

Ducting & Ventilation Components

FMKZ casette filter, EX

FlowAir CATALOG.

ALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm

Weld filter C10. Weld filter C20. Easy to move and position. Includes 3 m long extraction arm, Original. Cleanable filter with high filtration

1 of 8. Air Solutions Sdn. Bhd. Euro Carb. Box Type Chemical Filter

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

About Vacuum Producers

The reference in sandblasting. DCM\DCM 3000 a DCM to series.

THE WORLD OF EXTRACTION. Series EXTRACTION TECHNOLOGY FOR MAXIMUM EFFICIENCY

CARTRIDGE FILTER FOR DUST AND SMOKE SFC SERIES NEW. + Nanofibre Technology

MODEL FA1 Mini Air Filtration System. Operations Manual

Pneumatic Actuator PIK Series

Operating instructions

Owner s manual for installation, usage and maintenance

DIR. VARIZON Displacement unit with adjustable spread pattern. Quick guide

There are two general ways to capture airborne pollutants:

Horizontal downflow pleated cartridge dust collector

Weller Info No. 2. New in Weller Volume Extraction System WFE2ES

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

Improving your workspace

MODEL GS1-100 Air Filtration System. Operations Manual

DESKTOP CONTAINMENT SYSTEM

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

Fume Arms. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. No internal adjustment

MSB kw

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information

PULSE JET CARTRIDGE DUST COLLECTOR FEATURES ADVANTAGE

MG200 Filter system OPERATING INSTRUCTIONS FOR A BETTER WORKBENCH ENVIRONMENT FILTRONIC

Leading the way for clean air in the new millennium. S o u r c e C a p t u r e

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

VACUUM CONVEYOR SYSTEM

Shenzhen Xiangnan High-Tech Purify Equipment Co., Ltd

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Operation Manual for ARM-EVAC 150 Fume Extraction System

PRODUCT BROCHURE Cartridge-type Dust Collector DELBAG MultiJet. The system solution for dust

nivia utilities Why Air Filters???

MULTIDUST BANK APPLICATIONS AMBIENT CONDITIONS. Max. operating temperature

LEDGELESS VERTICAL CARTRIDGE DUST COLLECTOR

SF-1000 workbench - welding table. User s Manual.

A new dimension ZPF 9H the central suction and filter unit

BGT Series. Low Pressure Filters

PRICE LIST 08/2008. GROSS prices in L19. Validity: August 1 December 31, 2008

Horizontal downflow pleated cartridge dust collector

Air pollution control

A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S

Dust Extractor Selection Advice

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

FILTRATION FUME CABINET MODELS T800 T1800 OPERATING AND MAINTENANCE MANUAL

200-SERIES EXTRACTION

INSTALLATION INSTRUCTIONS

Portable HEPA System

Transcription:

A flexible modular filter for particles and gas The MOVEX modular filter CV with its sturdy profile allows the possibility to satisfy the need of several functions in one product. The filter in its basic version can be dimensioned to handle fumes from one work station. The CV filters can be connected in parallel to serve several work stations on the same system. Maximum flexibility from a simple disposable filter to a solution with cleaning via compressed air, but also the possibility to combine particleand gas filtration in the same unit or a gas filtration only. The filter unit is wall mounted and the sturdy profile makes the installation easy, but also simplifies necessary service and maintenance. The Movex range also includes fans, accessories, automatic control and local extraction for filters FILTER Pure advantage

Cleanable filter unit Cleanable filtration unit with a 150 feet² filter surface in polyester. The filter cartridge is cleaned via compressed air. Ø 6 5/16 78 3/4 84 5/8 Ø 6 5/16 14 5/16 3 1/8 17 11/16 8 1/4 8x Ø 3/8 20 1/2 Ø16 5/8 21 11/16 13 3/8 CVP Filter with manual compressed air cleaning, with an external pre-filter including a metal mesh. For applications with large amounts of dry particles, e.g. dust- and welding smoke in mechanical industries. Delivered with a filter cartridge, profile, two connections and requisite details for compressed air cleaning. It also includes an analogue pressure gauge that shows the pressure drop over the filter cartridge. The lower duct connection is 180 adjustable. Specifications CVP Profile brackets: 116 lb Max. temperature processed air: 140 F 1,8 133/8 5/8 21 0 200 400 600 800 cfm Type of filter cartridge: CFS 149 Material: Polyester Filter efficiency according to EN-60335-2-69: 99,9 % Dust class: M(BIA) Filter area: 160 ft²

How the CVP works Cleanable filter type CVP With manual compressed air cleaning the filter has a long lifetime, even when there is a high load over the filter cartridge. 1. To protect the filter cartridge from large particles, a pre-filter is placed on the inlet channel. The pre-filter can be mounted either on the wall or directly in the duct. 1 4 3 5 2 A vertical position of the filter simplifies a change of the filter cartridge. 2. Filter cartridge in polyester, with BIA filter class M, 150 feet² filter area. 3. Pressure gauge that shows the pressure drop over the filter cartridge. The initial pressure over the filter cartridge is - in/wg, depending on the airflow. When the pressure drop has increased to 3-4 in/wg the filter cartridge should be cleaned via the pulse valve. The most efficient cleaning is done with the fan shut off and with 3 to 5 pulses. The filter cartridge can also be cleaned with the fan on. Indication for filter change. 4. Multi-function valve for compressed air: Shut off valve and evacuation valve. Pressure release function to set correct cleaning pressure 50 PSI. Pressure gauge that shows the set cleaning pressure value. Pulse valve to manually clean the filter cartridge. 5. Tank for compressed air with integrated pulse nozzle. 6 6. Below the inlet for polluted air, a bin for collection of dust is placed.

Disposable filter in steel casing Filter unit with several options for filter cartridges (particle and gas). The cartridge is placed inside a powder coated steel casing. The filter cartridge and steel casing is placed between two gables on an anodized aluminium profile. For an easy filter cartridge change, the top gable is released and is lifted on the profile. 45 1/4 43 11/16 53 1/8 2 15/16 Ø16 5/8 13 3/8 21 11/16 Particle filter Filter for dry particles, e.g. dust- and welding smoke in mechanical industries. As a protection against big particles a pre-filter with a metal mesh is included inside the unit. Delivered with a filter cartridge, profile and two connections. CVH HEPA 13 filter with a very high level of separation. The filters are designed to create a clean zone, which is demanded when manufacturing e.g. pharmaceuticals and food. As a protection against big particles a pre-filter with a metal mesh is included inside the unit. Delivered completely with filter cartridge, profile and two connections. 1,8 CVH 0 200 400 600 800 cfm Specifications Profile brackets: 60 lb Max. temp. processed air: 140 F Type of filter cartridge: Material: Filter efficiency according -to EN-60335-2-69: -to DOP 0,3 μm: Dust class: Filter area: CFS 149 Polyester 99,9 % M(BIA) 160 ft² CVH CFH 160 Fiberglass 99,95 % 160 ft²

Gas filter CVC The cartridge is placed inside a powder coated steel casing. Contains a standardised active carbon that is suitable for absorption of odours, gases, smoke and VOC s: e.g. toluene and methyl ethyl ketone. To obtain the best result it s important to let the contact time between the carbon and the substance to be as long as possible. Therefore we recommend that the airflow over the filter module should not be higher than 300 cfm. For a greater airflow two or more filter modules can be placed side by side. If the polluted air also contains particles, it s advisable to place a particle filter before the carbon filter cartridge. Delivered with a filter cartridge, profile and two connections. 0 100 200 300 400 cfm Specifications CVC Profile brackets: 97 lb Recommended temperature: 68 F Max cfm: 300 cfm Type of filter cartridge: CFC 500 Weight: 35 lb Mesh size: 3/16 ft CTC absorption (W/W): 65 % Surface area (BET): 1050 m²/gr Apparent density: 9 kg/dm³ CVCC BiOn The cartridge is placed inside a powder coated steel casing. Contains an impregnated active carbon that is suitable for absorption of formaldehyde and ammonia. To obtain best result, it s important to let the contact time between the carbon and the substance to be as long as possible. Therefore we recommend that the airflow over the filter module should not be higher than 300 cfm. For a greater airflow two or more filter modules can be placed side by side. If the polluted air also contains particles, it s advisable to place a particle filter before the carbon filter cartridges. Delivered with a filter cartridge, profile and two connections. 0 100 200 300 400 cfm Specifications CVCC BiOn Profile brackets: 101 lb Recommended temperature: 68 F Max cfm: 300 cfm Type of filter cartridge: CFCC 500 BiOn Material: Impregnated active carbon Weight: 39 lb Mesh size: 3/16 ft CTC absorption (W/W): 45 % Surface area (BET): 900 m²/gr Apparent density: 0,75 kg/dm³ Impregnation KMnO4 11 %

Disposable filter The filter cartridge is placed between two gables on an anodized aluminum profile. 26 1/8 24 1/2 3 3/8 33 7/16 2 15/16 Ø16 5/16 21 9/16 13 3/8 CVD The filter cartridge has a surface area of 237 feet² in BIA class M. As a protection against big particles a pre-filter with a metal mesh is included inside the unit. The filter cartridge is placed between two gables on an anodized aluminum profile. Delivered with a filter cartridge, profile and two connections. For an easy filter cartridge change, the top gable is released and is lifted on the profile. 0 200 400 600 800 cfm Specifications CVD /paperboard Profile brackets: Max. temp. processed air: 140 F Type of filter cartridge: CFD 220 Material: Cellulose Filter efficiency according to EN-60335-2-69: 99 % Dust class: M(BIA) Filter area: 237 ft²

3/16 Accessories 106 For welding applications, fan 106 will provide an airflow of approximately 590 ft 3 / min and have a power output of 1,0 hp, single phase or three-phase. 106-3 3-phase (208/230/460 V) 4.10/3.70/1.85 A 106-1 1-phase (115 V) 10 A 18 15/16 17 13/16 6.0 5.0 4.0 3.0 2.0 1.0 22 5/16 13 3/8 Ø 1/2 7 7/8 8 3/8 3 9/16 14 3/16 200 400 600 800 1000 1200 1400 1600 cfm 6 5/8 CV R200-160 Reducer to. To be mounted on the inlet of the 075 for a connection to the CV filter. Ø7 7/8 4 15/16 CV PR Bracket to be mounted on wall to get the PR extractor to be lined up with the CV filter. 3 15/16 Ø 1/2 Ø 1/2 6 5/16 6 5/16 7 7/8 9 13/16 8 13/16 11 13/16 1 3/4 9 5/8 CV G Analogue pressure gauge that shows the pressure drop over the filter cartridge. Delivered in a set with hose, connections and a bracket so it can be mounted on the aluminum profile.

20180328 Installation example CVD PR CV PR PR CVP PRE-FILTER PR PRE-FILTER CVP PR CVC Phone: 610 440-0478 Fax: 610 440-0480 www.movexinc.com