technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

Similar documents
technical data air conditioning systems MXS-B Multi Application Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

Outdoor Units R-410A ARX-GV1B

Split-Sky Air RMX-JZ Super Multi Plus

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Split-Sky Air FAYP-B Wall Mounted Unit

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

Air Conditioning Technical Data RZQG-L(8)Y1

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

Air Conditioning Technical Data RZQSG-L3/9V1

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Fan Coil Units. Technical Data

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH

Air Conditioning. Technical Data EEDEN RXJ-L

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Air Conditioners Technical Data

Air Conditioning. Technical Data EEDEN RXZ-N

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

Technical Service Manual

Compact Four-way Cassette Type

SERVICE MANUAL OUTDOOR UNIT. No. OB387

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

SERVICE MANUAL OUTDOOR UNIT. No. OB386

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

High Wall Type ( 2 Series )

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SkyAir, Packaged Outdoor Units (RoHS application) RQ71KBV4A, RZQ71KBV1, RZQ71KBV4A, RZQ100KBV1 RZQ150HY4A RZQ150KV4A PL-908-1

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

PRODUCT CODE MODEL NAME. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty Qty REMARKS

PL-601. SkyAir Connection Units (RoHS application) BSVQ100MAV1, BSVQ160MAV1, BSVQ250MAV1. Air Cleaner (RoHS application) MC707SC, MC757SC, MC757SC-D

Service manual MIV V4+ Indoor units

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Wiring Diagram

PL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

Oil Cooler AKZ328-D142 PL

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P

PL-804. Remote Controller (RoHS application) BRC7F634F, BRC7F635F

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

PRODUCT CODE MODEL NAME RASC-10HNPE. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8

Four-way Cassette Type

Fault Codes. J control

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Low Static Pressure Duct(V shape evaporator)

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

Engineering Data Book

VRF Technical Data Book

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

SINGLE. Technical Data Book. HSP Duct for America (R410A, 60Hz, H/P)

AIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way)

Engineering Data Book

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

Digital Inverter 4 series

CASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

SERVICE MANUAL MUH-GA25VB - E1 MUH-GA25VB - MUH-GA35VB - E1 HFC. Wireless type Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB387 R410A CONTENTS

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

SERVICE MANUAL MUH-GA20VB- MUH-GA20VB- MUH-GA25VB- MUH-GA25VB- MUH-GA35VB- E1 OUTDOOR UNIT. No. OB387. Wireless type Models HFC

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

WCA4**4. Product Specifications

Low Static Pressure Duct (V shape evaporator)

CDK25JVEC, CDK35JVEC, CDX25BVMC, CDX25BVMC9, CDX25JVEC, CDX35BVMC, CDX35BVMC9, CDX35JVEC, CDX50AVMC9, CDX60AVMC9 CDK35HAVER1, CDK60HAVER1

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

Transcription:

technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i 2 nye U_ k BS Mr V o ta oa D i d0- l t S p4u X RS OM Outdoor units for Multi model application. Up to 5 indoor units can be connected to Multi outdoor unit. All indoor units are individually controllable with remote control and do not need to be installed in the same room or at the same time. They operate simultaneously within the same cooling operation It is possible to combine different types of indoor units as well. (e.g. wall mounted, ceiling mounted cassette corner, concealed ceiling unit) Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency Split Sky Air Outdoor Units

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 2 Specifications 2- TECHNICAL SPECIFICATIONS 2MXS4 0DAVMB 2MXS52E2VB MXS52E2VB 4MXS68E2VB 4MXS80E7VB 5MXS90E7VB Casing Colour Ivory White Dimensions Unit Height mm 640 75 75 75 770 770 Width mm 685 96 96 96 900 900 Depth mm 285 00 00 00 20 20 Packing Height mm 676 797 797 784 900 900 Width mm 800 992 992 992 925 925 Depth mm 66 90 90 90 90 90 Weight Unit kg 9 49 49 59 72 7 Heat Exchanger Packed Unit kg 42 56 56 65 80 80 Dimensions Length mm 678 845 845 845 860 860 Nr of Rows 2 2 2 2 2 Fin Pitch mm.4.80.80.60.40.40 Nr of Stages 28 2 2 2 4 4 Tube type Hi-Xa(8) ø7.94 grooved tubes 24 ø7.94 grooved tubes 24 Hi-Xa(8) Hi-XSS(8) Hi-XSS(8) Fin Type WF fin Colgate fin Colgate fin WF fin WF fin WF fin Treatment Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Fan Type Propeller Motor Anti-corrosion treatment (PE) Quantity Air Flow Rate (nominal at 20V) m³/min 5 45.0 45.0 5.0 54.5 54.5 m³/min 2 45.0 45.0 47.6 46.0 Motor Quantity Speed (nominal) Model D50E-28 KFD-80-50-8A KFD-80-50-8A KFD-80-5-8C KFD-280-66-8A KFD-280-66-8A rpm 880 720 720 790 860 rpm 880 720 790 Fan Motor Output W 50 5 5 5 66 66 Compressor Quantity Operation Range Sound Level (nominal) Sound Level (Night quiet) Motor Model YC2GXD 2YC6BXD 2YC6BXD 2YC45BXD 2YC6BXD#C 2YC6BXD#C Type Motor Output Hermetically sealed swing compressor W 600 00 00 80 920 920 Min CDB 0-0.0-0.0-0.0-0.0-0.0 Max CDB 46 46.0 46.0 46.0 46.0 46.0 Min CWB -0-5 -5-5 -5-5 Max CWB 5.5 5.5 5.5 5.5 5.5 5.5 Sound Power Sound Pressure Sound Pressure dba 62 59.0 59.0 6.0 62.0 66.0 dba 47 46.0 46.0 48.0 48.0 52.0 dba 48 47.0 47.0 49.0 49.0 52.0 Sound Pressure dba 4 Refrigerant Type R-40A Charge kg.20 2.0 2.0 2.6.0.0 Refrigerant Oil Type FVC50K Charged Volume l 0.40 0.65 0.65 0.75 0.75 0.75 2 Split Sky Air Outdoor Units 2

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 2 Specifications 2 2- TECHNICAL SPECIFICATIONS 2MXS40DAVMB 2 MXS52E2VB MXS52E2VB 4MXS68E2VB 4MXS80E7VB 5MXS90E7VB Liquid (OD) Quantity 2 2 4 4 5 Piping connections Standard Accessories Notes Diameter (OD) mm 6.5 6.5 6.5 6.5 6.5 6.5 Gas Quantity 2 2 2 2 2 Diameter (OD) mm 9.5 2.7 9.5 9.5 9.5 9.5 Quantity 2 Diameter (OD) mm 2.7 2.7 2.7 2.7 Quantity 2 2 Diameter (OD) mm 5.9 5.9 Drain Quantity Diameter (OD) mm 8 8 8 8 25 25 Piping Length Minimum m.5 (for one room) Additional Refrigerant Charge Installation height difference Max. internunit level difference Heat Insulation Item Maximum m 0 ( for total of each room), 20 (for one room) 50 (for total of each room)/25 (for one room) 50 (for total of each room)/ 25 (for one room) 60 (for total of each room)/ 25 (for one room) 70 (for total of each room)/ 25 (for one room) 75 (for total of each room)/ 25 (for one room) kg/m 0.02/>20 0.02/>0m 0.02/>0m 0.02/>0m 0.02/>0m 0.02/>0m Maximum m 5(between indoor unit and outdoor unit) m 7.5 (between indoor units) 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) Both liquid and gas pipes Installation manual 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) Quantity pc Item Screw bag Drain plug Drain plug Drain plug Drain plug Drain plug Quantity pc Item Reducer assembly Reducer assembly Reducer assembly Reducer assembly Quantity Reducer assembly Nominal cooling capacities are based on : indoor temperature : 270CDB, 90CWB, outdoor temperature : 50CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on : indoor temperature : 200CDB, outdoor temperature : 70CDB, 60CWB, equivalent refrigerant piping : 7.5m, level difference : 0m Sound levels are measured in an anechoic room Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. 2-2 ELECTRICAL SPECIFICATIONS 2MXS40DAVMB 2 MXS52E2VB MXS52E2VB 4MXS68E2VB 4MXS80E7VB 5MXS90E7VB Power Supply Name VM V V V V V Current Phase Frequency Hz 50/60 50 50 50 50 50 Voltage V 220-240/220-20 20 20 20 20 20 Voltage range Minimum V -0% -0% -0% -0% -0% Nominal running current (RLA) Maximum V +0% +0% +0% +0% +0% (A) (A) Starting current (cooling/ heating) A 0. 0. 0. 0.97 0.97 A 0. 0. 0. 0.69 A 6.2 6.7 6.2 8.5 9.7.8 Z-max List No requirements Split Sky Air Outdoor Units

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 2 Specifications 2-2 ELECTRICAL SPECIFICATIONS 2MXS4 0DAVMB 2MXS52E2VB MXS52E2VB 4MXS68E2VB 4MXS80E7VB 5MXS90E7VB Wiring connections Power Supply Intake For Power Supply For connection with indoor Quantity 4 Quantity 4 4 4 4 4 5 Outdoor unit only 2 Split Sky Air Outdoor Units 4

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA 2.0.4 2. 40 0.7 2.5 4.7.0 40 0.7.5 6.5 4.6 40 0.7 2.0+2.0 6.7 4.9 80 0.4 50 20 207 25 2 50 0.40 2.0+2.5 6.7 5.0 80 0.4 2.0+.5 6.8 5.0 80 0.4 2.5+2.5 6.8 5.0 80 0.4 2.5+.5 6.8 5.0 80 0.4 (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA 2.0 6.2 4. 40 0.7 2.5 7.5 4.7 40 0.7.5 8.6 5.7 40 0.7 2.0+2.0 6.4 4.6 80 0.4 50 20 207 25 2 50 0.40 2.0+2.5 6.6 4.8 80 0.4 2.0+.5 6.6 4.8 80 0.4 2.5+2.5 6.6 4.8 80 0.4 2.5+.5 6.6 4.8 80 0.4 MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 240V Indoor temp.: 27 CDB/9.0 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. For more details concerning conditional connections, see http://eu.extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 5 Split Sky Air Outdoor Units

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB MXS52E Model Units Power supply Comp. OFM H/P Outdoor Hz Volts Min. Max. MCA MFA MSC RLA W FLA C/D D052807 MCA MFA MSC RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (See note 6). (A) : MSC means the max. current during the starting of compressor. (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Indoor temp.: 27 CDB/9.0 CWB Outdoor temp. : 5 CDB 2. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits. Maximum allowable voltage variation between phases is 2% 4. MCA represents maximum input current. MFA represents capacity which may accept MCA 5. Select wire size based on the larger value of MCA. 6. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 6

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-5B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5kW class: wall mounted C series 5.0, 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 7 Split Sky Air Outdoor Units

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-6B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5kW class: wall mounted C series 5.0, 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 8

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-7B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5kW class: wall mounted C series 5.0, 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 9 Split Sky Air Outdoor Units

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-8B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5kW class: wall mounted C series 5.0, 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 0

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5, 5.0kW class: wall mounted D series 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-2B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5, 5.0kW class: wall mounted D series 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 2

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5, 5.0kW class: wall mounted D series 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-4B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5, 5.0kW class: wall mounted D series 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 4

Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS80E, 5MXS90E Model Units Power supply Comp. OFM H/P Outdoor Hz Volts Min. Max. MCA MFA MSC RLA W FLA C/D D05265 MCA MFA MSC RLA OFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (See note 6). (A) : MSC means the max. current during the starting of compressor. (A) : Rated Load Amps (A) : Outdoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Indoor temp.: 27 CDB/9.0 CWB Outdoor temp. : 5 CDB 2. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits. Maximum allowable voltage variation between phases is 2% 4. MCA represents maximum input current. MFA represents capacity which may accept MCA 5. Select wire size based on the larger value of MCA. 6. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker) 7. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 5 Split Sky Air Outdoor Units

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4 Options 4MXS, 5MXS N Item 4MXS80E7 5MXS90E7 5MKS90E7 Drain plug KKPJ5F80 4TW2757-4 Split Sky Air Outdoor Units 6

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6 - Dimensional drawing 6 2MXS40D Drain outlet (I.D. J5.9 hose for connection) 4-cuts for anchor bolts Interconnecting piping and wiring inlet unit (mm) Outdoor air thermistor Brand name label 2-Terminal strip with earth terminal <room A> Liquid stop (J 6.4 Cut) Gas stop (J 9.5 Cut) Minimum space for air passage Wall height on air outlet side = less than 200 Name plate Service port In case of removing stop cover <room B> Liquid stop (J 6.4 Cut) Gas stop (J 9.5 Cut) D099A 2MXS52E unit (mm) 2-cuts for anchor bolts (M8 or M0) Minimum space for air passage Wall height on air outlet side = less than 200 00 or more A 2- J 2 Hole Liquid J 6.4 95 Drain outlet (M8 or M0) DIMENSIONS A Gas J 2.7 76 H % 200 50 (I.D. J5.9 hose for connection) H > 200 600 Name plate -Terminal strip -Earth terminal Interconnecting piping and wiring inlet Outdoor air thermistor Installation space for discharge side (mm) <room A> (J2.7 single union) <room B> (J2.7 single union) Liquid stop Service port Gas stop D05790 89 Split Sky Air Outdoor Units

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6 - Dimensional drawing MXS52E unit (mm) 2-cuts for anchor bolts (M8 or M0) Minimum space for air passage Wall height on air outlet side = less than 200 00 or more 6 Drain outlet (I.D. J5.9 hose for connection) 2- J 2 Hole (M8 or M0) A Liquid J 6.4 95 Gas J 9.5 85 J 2.7 76 DIMENSIONS A H % 200 50 H > 200 600 Installation space for discharge side (mm) Name plate 4-Terminal strip 4-Earth terminal Interconnecting piping and wiring inlet Outdoor air thermistor <room A> (J9.5 single union) <room B> (J9.5 single union) <room C> (J2.7 single union) Liquid stop Service port Gas stop D0579 4MXS68E 4-cuts for anchor bolts (M8 or M0) <room A> (J9.5 single union) <room B> (J9.5 single union) Minimum space for air passage Wall height on air outlet side = less than 200 unit (mm) Drain outlet (I.D. J 5.9 hose for connection) 5-Terminal strip with earth terminal <room C> (J2.7 single union) <room D> (J5.9 single union) Name plate Interconnecting piping and wiring inlet Outdoor air thermistor A Liquid J 6.4 95 Gas J 9.5 85 J 2.7 76 Liquid stop Service port Gas stop D0472G Split Sky Air Outdoor Units 90

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6 - Dimensional drawing 4MXS80E Minimum space for air passage unit (mm) 6 4-cuts for anchor bolts Wall height on air outlet side = less than 200 Drain outlet I.D. J 25 hose for connection Name plate Gas stop 5-Terminal strip with earth terminal Liquid stop Outdoor air thermistor A J 6.4 08 J 9.5 9 J 2.7 8 J 5.9 78 Interconnecting piping and wiring inlet <room A> (J9.5 single union) <room B> (J2.7 single union) <room C> (J5.9 single union) <room D> (J5.9 single union) D05950 5MXS90E unit (mm) 4-cuts for anchor bolts Minimum space for air passage Wall height on air outlet side = less than 200 Drain outlet I.D. J 25 hose for connection Name plate Gas stop 6-Terminal strip with earth terminal Liquid stop Outdoor air thermistor <room A> (J9.5 single union) <room B> (J9.5 single union) <room C> (J2.7 single union) A Liquid J 6.4 08 J 9.5 9 Gas J 2.7 8 J 5.9 78 Interconnecting piping and wiring inlet <room D> (J5.9 single union) <room E> (J5.9 single union) D05948A 9 Split Sky Air Outdoor Units

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6-2 Centre of gravity 2MXS40D 6 Anchor bolt 4D04069A 2MXS52E, MXS52E, 4MXS68E Anchor bolt 4D07024H Split Sky Air Outdoor Units 92

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6-2 Centre of gravity 4MXS80E, 5MXS90E 6 Anchor bolt 4D052059 9 Split Sky Air Outdoor Units

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 7 Piping diagram 2MXS40D Outdoor unit Branch pipe Heat exchanger Outdoor temperature thermistor (DOA) Liquid receiver Distributor Liquid receiver Motor operated Motor operated thermistor (DLA) thermistor (DLB) Liquid line stop Liquid line stop (6.4 CuT) (6.4 CuT) Field piping liquid 7 Heat exchanger thermistor(de) Fan motor Propeller fan Reversing solenoid Branch pipe Muffler Muffler (DGA) (DGB) Gas line stop Gas line stop (9.5 CuT) (9.5 CuT) Field piping gas Discharge pipe thermistor (DO) Muffler Muffler Refrigerant flow Compressor Accumulator D0992A 2MXS52E Outdoor unit Header Heat exchanger thermistor (DE) Heat exchanger Outdoor temperature thermistor (DOA) Distributor Header Electronic expansion Electronic expansion thermistor (DLA) thermistor (DLB) Field piping liquid (Liquid side) DC fan motor Capillary tube Liquid line stop Propeller fan Reversing solenoid Header (DGA) Muffler Discharge pipe thermistor (DO) Muffler Muffler (DGB) Field piping gas (Gas side) Refrigerant flow Compressor Accumulator Gas line stop D052054 Split Sky Air Outdoor Units 94

7 Piping diagram Outdoor Units R40A MXS-DAVMB_E2VB_E7VB MXS52E Outdoor unit 7 Header Heat exchanger Outdoor temperature thermistor (DOA) Header Electronic expansion Electronic expansion thermistor (DLA) thermistor (DLB) Heat exchanger thermistor (DE) DC fan motor Capillary tube Distributor Liquid line stop Electronic expansion thermistor (DLC) Field piping liquid (Liquid side) Propeller fan Header Reversing solenoid (DGA) Refrigerant flow Muffler Discharge pipe thermistor (DO) Compressor Accumulator Muffler Muffler Gas line stop (DGB) (DGC) Field piping gas (Gas side) D052055 4MXS68E Outdoor unit Header Heat exchanger thermistor (DE) DC fan motor Heat exchanger Outdoor temperature thermistor (DOA) Capillary tube Distributor Defrost solenoid Header Liquid line stop Electronic expansion thermistor (DLA) Electronic expansion thermistor (DLB) Electronic expansion thermistor (DLC) Electronic expansion thermistor (DLD) Field piping liquid (Liquid side) Propeller fan Refrigerant flow Reversing solenoid Muffler Discharge pipe thermistor (DO) Compressor Accumulator Accumulator Header Gas line stop (DGA) (DGB) (DGC) (DGD) Field piping gas (Gas side) D045G 95 Split Sky Air Outdoor Units

7 Piping diagram Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS80E Outdoor unit Header Heat exchanger Outdoor temperature thermistor Receiver Header Motor operated (A) thermistor (Room-A) Motor operated (B) thermistor (Room-B) 7 Heat exchanger thermistor (Condenser) Motor operated (C) thermistor (Room-C) Field piping liquid Motor operated (D) thermistor (Room-D) Room D DC fan motor Capillary tube Distributor Liquid line stop Motor operated (E) Propeller fan 4-way Header (Room-A) (Room-B) Refrigerant flow Muffler Discharge pipe thermistor Compressor Accumulator Accumulator Gas line stop Muffler Muffler (Room-C) (Room-D) Room D Field piping gas D0597B 5MXS90E Outdoor unit Header Heat exchanger Outdoor temperature thermistor Receiver Header Motor operated (A) thermistor (Room-A) Motor operated (B) thermistor (Room-B) Heat exchanger thermistor (Condenser) Motor operated (C) thermistor (Room-C) Field piping liquid Motor operated (D) thermistor (Room-D) Room D DC fan motor Distributor Motor operated (E) Capillary tube Liquid line stop thermistor (Room-E) Room E Propeller fan 4-way Header (Room-A) (Room-B) Muffler Discharge pipe thermistor (Room-C) (Room-D) Room D Field piping gas Refrigerant flow Compressor Accumulator Accumulator Gas line stop Muffler Muffler (Room-E) Room E D0596A Split Sky Air Outdoor Units 96

8 Wiring diagram 8 - Wiring diagram 2MXS40D Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 8 Indoor Power supply 50Hz 220-240V 60Hz 220-20V g Field wiring Outdoor () () () () (outdoor) (discharge) (condenser) () () Colours BLK: Black / BRN: Brown / WHT: White / RED: Red / BLU: Blue / GRY: Grey / ORG: Orange / YLW: Yellow C5 C8, SHC CT DB, DB FU FU L L LR MC MF MRCW, MRM0, MRM20 N : Capacitor : Current transformer : Diode bridge : Fuse : Live : Coil : Reactor : Compressor motor : Fan motor : Magnetic relay : Neutral OIS : Solid state relay PCB, PCB2 : Printed circuit board QL : Overload protector RT R8T : Thermistor SA : Surge arrester TFU : Thermal fuse TRM : Transistor module V, V2, V : Varistor XM, X2M : Terminal strip YE, Y2E : Electronic expansion coil YR : Reversing solenoide coil ZC : Ferrite core R : Protective earth S0 S2, S20, S2, S0 S40, S45, S70, S80, S90 S92, HL, HL2, HN, HN2, HR, HR4, AC, AC2, HC, HC4, E, X0A : Connector D09565A 2MXS52E Power supply To indoor unit Sheet metal Indoor g Field wiring (outdoor) (discharge) () () () () (condenser) () () Outdoor ZC ZC : Ferrite core XM XM : Terminal strip YE YE : Electronic expansion coil V2,V,V5,V6,V : Varistor SA2 : Surge arrester FU, FU2, FU : Fuse AC, AC2 U, V, W, XA E, E2 HR, HR2 : Connector MRM0, MRM20 MRC/W : Magnetic relay RT R5T R8T, R9T S2 S02 LED LED4 LEDA L N SW S2W SW S4W S5W : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch (SW) : Select SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) MC MF LR QL PM PCB, 2 YR Sheet metal : Compressor motor : Fan motor : Reactor : Overload protector : Power module : Printed circuit board : Reversing solenoid : Terminal strip fixed plate D050-97 Split Sky Air Outdoor Units

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 8 Wiring diagram 8 - Wiring diagram MXS52E Power supply 8 To indoor unit Sheet metal Indoor (discharge) () () (outdoor) () () (condenser) () () g Field wiring Outdoor () () ZC ZC : Ferrite core XM X4M : Terminal strip YE YE : Electronic expansion coil V2,V,V5,V6,V : Varistor SA2 : Surge arrester FU, FU2, FU : Fuse AC, AC2 U, V, W, XA E, E2 HR, HR2 : Connector MRM0, MRM20 MRC/W : Magnetic relay RT R6T R8T R0T S2 S02 LED LED4 LEDA L N SW S2W SW S4W S5W : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch (SW) : Select SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) MC MF LR QL PM PCB, 2 YR Sheet metal : Compressor motor : Fan motor : Reactor : Overload protector : Power module : Printed circuit board : Reversing solenoid : Terminal strip fixed plate D0502-4MXS68E g Field wiring To indoor unit Room D (outdoor) (discharge) () () () () (condenser) () (Room D) () (Room D) () () ZC ZC : Ferrite core XM X5M : Terminal strip YE Y4E : Electronic expansion coil V2 V5 : Varistor FU, FU2, FU20 : Fuse HE, HL, HN E, AC, AC2 H, H2, L L2 : Connector MRM0, MRM20 MRB, MRD MRC/W : Magnetic relay RT R2T S2 S02 HP H5P L N SW S2W SW S4W S5W SA YR : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch (SW) : Select SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) : Surge arrester : Reversing solenoid YS PCB DB MC MF LR QL CT MID MID2 SPM : Defrost solenoid coil : Printed circuit board : Diode bridge : Compressor motor : Fan motor : Reactor : Overload protector : Current transformer : Molded interconnect device : System power module D042J Split Sky Air Outdoor Units 98

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 8 8 Wiring diagram 8 - Wiring diagram 4MXS80E BLK: Black BRN: brown WHT: White RED: Red BLU: Blue GRY: Grey ORG: Orange YLW: Yellow GRN: Green To indoor unit Room D Sheet metal Outdoor Condenser Discharge Room D Room D Indoor Outdoor L: Live, N: Neutral, : Field wiring : Terminal strip : Connector : Connection : Protective earth (screw) : Relay connector : Terminal ZC Z6C XM X5M YE Y4E V2,V,V5 V9,V00 SA2 FU, FU2, FU AC,AC2 U,V,W,XA E,E2E HR,HR2 MRM0, MRM20 MRC/W : Ferrite core : Terminal strip : Electronic expansion coil : Varistor : Surge arrester : Fuse : Connector : Magnetic relay RT RT R4T R7T R8T RT S2 S02 LED LED4 LEDA SW SW2 SW SW4 SW5 MC MF LR : Thermistor : Connector : Light emitting diode : Forced operation on/off switch (SW) : Operation mode sellect SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) : Compressor motor : Fan motor : Reactor QL PM PCB,2 YR Sheet metal F2U QDI : Overload protector : Power module : Printed circuit board : Four way coil : Terminal strip fixed plate : Field fuse : Field earth leakage breaker (00mA) 2TW57576-5MXS90E BLK: Black BRN: brown WHT: White RED: Red BLU: Blue GRY: Grey ORG: Orange YLW: Yellow GRN: Green To indoor unit Room D Room E Outdoor Condenser Discharge Room D Room E Room D Room E Indoor Sheet metal Outdoor L: Live, N: Neutral, : Field wiring : Terminal strip : Connector : Connection : Protective earth (screw) : Relay connector : Terminal ZC Z6C : Ferrite core XM X6M : Terminal strip YE Y5E : Electronic expansion coil V2,V,V5 V9,V00 : Varistor SA2 : Surge arrester FU, FU2, FU : Fuse AC,AC2 U,V,W,XA E,E2E HR,HR2 H, H2, L, L2 : Connector MRM0, MRM20 MRC/W : Magnetic relay RT RT R4T R8T R9T RT S2 S02 LED LED5 LEDA SW SW2 SW SW4 SW5 MC MF LR : Thermistor : Connector : Light emitting diode : Forced operation on/off switch (SW) : Operation mode sellect SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) : Compressor motor : Fan motor : Reactor QL PM PCB,2 YR Sheet metal F2U QDI : Overload protector : Power module : Printed circuit board : Four way coil : Terminal strip fixed plate : Field fuse : Field earth leakage breaker (00mA) 2TW57586-99 Split Sky Air Outdoor Units

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 9 Sound data 9 - Sound pressure spectrum 2MXS40D () 2MXS40D () 9 Octave band sound pressure level db:(0db = 0.0002 µ bar) Octave band sound pressure level db:(0db = 0.0002 µ bar) approximate threshold hearing for continuous noise D04067A Legend Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. Reference acoustic pressure 0dB = 20µPa 50/60Hz, 220-240/220-20V D04067A approximate threshold hearing for continuous noise Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. Reference acoustic pressure 0dB = 20µPa Legend Octave band center frequency (Hz) 50/60Hz, 220-240/220-20V 4MXS68E () 4MXS68E () Octave band sound pressure level db:(0db = 0.0002 µ bar) Octave band sound pressure level db:(0db = 0.0002 µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise D04807F Octave band center frequency (Hz) D04807F Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 Split Sky Air Outdoor Units 400

Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 9 Sound data 9 - Sound pressure spectrum 4MXS80E () 4MXS80E () 9 Octave band sound pressure level db:(0db = 0.0002 µ bar) Octave band sound pressure level db:(0db = 0.0002 µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise D0520 Octave band center frequency (Hz) D0520 Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 5MXS90E () 5MXS90E () Octave band sound pressure level db:(0db = 0.0002 µ bar) Octave band sound pressure level db:(0db = 0.0002 µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise D05202 Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 D05202 Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 40 Split Sky Air Outdoor Units

9 Sound data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 9-2 Sound power spectrum 4MXS80E Octave band sound pressure level db:(0db = 0.0002 µ bar) 5MXS90E Sound power level(db) 9 TW27577- Octave band center frequency (Hz) db(a) = A-weighted sound power level (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 0E-6 µw/m 2 Measured according to ISO 744 TW27597- Octave band center frequency (Hz) dba = A-weighted sound power level (A-scale according to IEC) 2 Refernece acoustic intensity 0dB = 0E-6µW/m_ Measured according to ISO 744 Split Sky Air Outdoor Units 402

0 Operation range Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 2MXS40D 0 (50 / 60 Hz) Outdoor temperature ( CDB) Continuous operation Pull-down period Outdoor temperature ( CWB) Continuous operation Indoor temp. ( CWB) Indoor temp. ( CDB) Notes: The graphs are based on the following conditions: d Equivalent piping length 7.5m d Level difference 0m d Air flow rate Hi speed D04065A 2MXS52E, MXS52E, 4MXS68E (50 / 60 Hz) Outdoor temperature ( CDB) Continuous operation Pull-down period Outdoor temperature ( CWB) Continuous operation Indoor temp. ( CWB) Notes: Indoor temp. ( CDB) The graphs are based on the following conditions: d Equivalent piping length 7.5m d Level difference 0m d Air flow rate Hi speed D04956H 40 Split Sky Air Outdoor Units

0 Operation range Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS80E, 5MXS90E (50 / 60 Hz) 0 Outdoor temperature ( CDB) Continuous operation Pull-down period Outdoor temperature ( CWB) Continuous operation Indoor temp. ( CWB) Indoor temp. ( CDB) Notes: The graphs are based on the following conditions: d Equivalent piping length 7.5m d Level difference 0m d Air flow rate Hi speed D05204 Split Sky Air Outdoor Units 404

0 Operation range Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 0 405 Split Sky Air Outdoor Units