Contactors (9 to 85A)

Similar documents
22AF 40AF AF 150AF 225AF 400AF 800AF

Thermal overload relays, Class 10A

Mini contactors. Mini contactors providing various connections and Accessories. Screw clamps. Ratings. For fast-on connections

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Quick selection table

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Ktec Contactors and thermal overloads

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Meta Solution. Contactors and Overload relays

Manual Motor Starters. Meta-MEC

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors

Meta Solution. Contactors and Overload relays

Bulletin 190-M Compact Starters. Selection Guide

Meta Solution. Contactors and Overload relays

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

LSIS Electric Products. ACB / MCCB / MCB / MC&TOR / Mini-MS / MMS / EMPR

Switches Unlimited Phone: * Fax:

IEC Contactors. IEC Contactors. YS Series. YS Series Contactors YS1N- F11 ****

Thermal Overload Relays

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

EW series Industrial contactors

Page 2-4 Page 2-8. Page Page 2-13

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Contactors & Overload relays

Overload Relay Heater Tables

Industrial Contactors CTX 3 3P 185A - 800A

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

A200 NEMA Contactors and Starters A200

Industrial contactors CTX-1

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

AF series contactors (9 2650)

AF40... AF96 3-pole contactors Technical data

CWM_N NEMA Rated Contactors

Metasol MC 4pole. Contactor. Overview 108 Table of specifications 110 Dimension 114. Contents

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Cross reference. Definite Purpose Contactors

XMC0 Series DEFINITE PURPOSE CONTACTORS

AF series contactors (9 2650)

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

W Datasheet: DIN Rail Contactors, series AMPARO

3. Coils shall be of molded construction

MAGNETIC MOTOR STARTERS

4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.

Selection Guide Motor Control Device Solutions

XMC0 Series. Definite Purpose Contactors

Motor Starting Solutions Open Type Version, in Kit Form

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

CI-TI Contactors and motor starters Types CI 61 - CI 98

Low voltage switch gear

Technical Information

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

ACS motor protection circuit breakers KT 7 Introduction

CJX2N Series AC Contactor

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

MAGNETIC CONTACTOR & MOTOR STARTER

MAGNETIC CONTACTOR & MOTOR STARTER

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (2 of 2) Lecture 6 Contactors and Motor Starters

Enclosures. See Section Typical Description

UMBW-UL489 and UL1077 Listed

3VU13, 3VU16 Circuit-Breakers

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Self-protected Combination Starters System PKZ 2-SP

2.1. NEMA Contactors and Starters

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Thermal Overload Relays - WEG RW Series, 2 Pole

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

Features. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12

Essential equipment for all your requirements

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V)

Capacitor Switching Contactors Type K3...-A, K3...-K

Abox-i Series. petrochemical plants, steel mills and railways.

Components for EEx e Panels

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Command and signalling E 250, E 259 selection table

Manual Motor Starters


DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

ASL09..S 3-pole Contactors - Spring Terminals

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Mini Contactors CI 4-

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

Page 2-4 Page 2-8. Page Page 2-12

SD Series Non-Fused Load Switches

HP Series. Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Function Relays, Interfaces and Converters

Extended/Direct Handle Motor Disconnect Switch

4 - Miniature controls

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

Micro Contactor MA Series

Thermal overload relay TF140DU and TF140DU-V1000

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Thermal overload relay TF65 and TF96

Starting of Induction Motors

Transcription:

Contactors (9 to 85A) Frame size 9A 12A 18A 22A -pole Contactors For further technical information see pages 8-9. includes AU-1 auxililary switch, (1 N.O. / 1 N.C.) Types AC coil DC coil GMC-9 GMD-9 GMC-12 GMD-12 GMC-18 GMD-18 GMC-22 GMD-22 Ratings / IEC60947-4 kw A kw A kw A kw A AC1 25 25 40 40 AC 200/240V 2.5 11.5 1 4.5 18 5.5 22 80/440V 4 9 5.5 12 7.5 18 11 22 500/550V 4 7 7.5 12 7.5 1 15 22 690V 4 5 7.5 9 7.5 9 15 18 Ratings / UL508 hp A hp A hp A hp A continuous current 20 25 0 2 single phase 115V 0.5 0.5 1 2 20V 1 2 three phase 200V 2 5 7 20V 2 5 7. 5 460V 5 7.5 10 10 575V 7.5 10 15 15 NEMA size 00 00 0 0 4-pole Contactors For further technical information visit altechcorp.com. Types AC coil GMC-9/4 GMC-12/4 GMC-18/4 GMC-22/4 DC coil GMD-9/4 GMD-12/4 GMD-18/4 GMD-22/4 AC1(A) 20 20 25 2 Available coil voltages Additional Auxiliary Contacts AC: 24, 42, 48, 110, 120, 208, 220, 240, 277, 80, 440, 480, 600V DC: 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V Ordering Example: GMC-9-AC120V (see also page 6) AU-2 2-pole Front mount AU-4 4-pole Front mount AU-1 2-pole Side mount Configuration Part No. Configuration Part No. Configuration Part No. Overload Relays 2 N.O. AU-2-20 2 N.C. AU-2-02 1 N.O. / 1 N.C. AU-2-11 4 N.O. AU-4-40 N.O. / 1 N.C. AU-4-1 2 N.O. / 2 N.C. AU-4-22 1 N.O. / N.C. AU-4-1 4 N.C. AU-4-04 1 N.O. / 1 N.C. AU-1 Bimetallic style Type GT GT-22 Setting ranges (A) 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.6 0.6-1 1-1.6 1.6-2.5 2.5-4 4-6 5-8 6-9 7-10 9-1 12-16 16-22 AZ-22H Base for separate mounting Class 10A Class 20 Differential Non-differential (-heater) Non-differential (2-heater) Differential GTK-22 GTH-22/ GTH-22 GTK-22/L

Contactors (9 to 85A) 2A 40A 50A 65A 75A 85A includes 2 AU-1 auxililary switches, (2 N.O. / 2 N.C.) includes 2 AU-1 auxililary switches, (2 N.O. / 2 N.C.) GMC-2 GMC-40 GMC-50 GMC-65 GMC-75 GMC-85 GMD-2 GMD-40 GMD-50 GMD-65 GMD-75 GMD-85 kw A kw A kw A kw A kw A kw A 50 60 80 100 110 15 7.5 2 11 40 15 55 18.5 65 22 75 25 85 15 2 18.5 40 22 50 0 65 7 75 45 85 18.5 28 22 2 0 4 60 7 64 45 75 18.5 20 22 2 0 28 5 7 42 45 45 hp A hp A hp A hp A hp A hp A 45 50 70 80 90 100 2 5 5 7.5 5 5 7.5 10 15 15 7.5 10 10 15 20 25 10 10 15 20 25 0 20 25 0 40 50 50 20 25 0 40 50 50 1 1 2 2 2 GMC-2/4 GMC-40/4 GMC-50/4 GMC-65/4 GMC-75/4 GMC-85/4 GMD-2/4 GMD-40/4 GMD-50/4 GMD-65/4 GMD-75/4 GMD-85/4 50 60 80 100 110 15 AC: 24, 48, 110, 120, 208, 220, 240, 277, 80, 440, 480, 600V DC: 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V Ordering Example: GMC-2-AC120V (see also page 6) AU-2 AU-4 AU-1 2-pole Front mount 4-pole Front mount 2-pole Side mount Configuration Part No. Configuration Part No. Configuration Part No. 2 N.O. AU-2-20 2 N.C. AU-2-02 1 N.O. / 1 N.C. AU-2-11 4 N.O. AU-4-40 N.O. / 1 N.C. AU-4-1 2 N.O. / 2 N.C. AU-4-22 1 N.O. / N.C. AU-4-1 4 N.C. AU-4-04 1 N.O. / 1 N.C. AU-1 GT-40 Setting ranges (A) 4-6 5-8 6-9 7-10 9-1 12-18 16-22 18-26 24-6 28-40 AZ-40H Base for separate mounting GT-85 Setting ranges (A) 7-10 9-1 12-18 16-22 18-26 24-6 28-40 4-50 45-65 54-75 6-85 AZ-85H Base for separate mounting GTK-40 GTK-85 GTH-40/ GTH-85/ GTH-40 GTK-40/L GTH-85 GTK-85/L 2

Contactors (100 to 800A) Frame size 100A 125A 150A -pole Contactors For further technical information see pages 10-11. includes 2 AU-100 auxililary switches, (2 N.O. / 2 N.C.) includes 2 AU-100 auxililary switches, (2 N.O. / 2 N.C.) Types AC/DC common coil GMC-100 GMC-125 GMC-150 Ratings / IEC60947-4 kw A kw A kw A AC1 150 150 200 AC 200/240V 0 105 7 125 45 150 80/440V 55 105 60 120 75 150 500/550V 55 85 60 90 90 140 690V 55 65 60 70 90 100 Ratings / UL508 hp A hp A hp A continuous current single phase three phase NEMA size 115V 20V 200V 20V 460V 575V 7.5 15 0 0 60 60 160 10 20 40 40 75 75 160 15 25 40 50 100 100 4 210 4-pole Contactors For further technical information visit altechcorp.com. Types AC/DC common coil GMC-100/4 GMC-125/4 GMC-150/4 AC1(A) 150 155 200 Available nominal coil voltages (AC 50/60Hz); (DC) Additional Auxiliary Contacts Overload Relays AC: 24 (24-25), 48 (48-50), 100/200 (100-240), 00 (265-47), 400 (80-450), 500V (440-575) DC: 24, 48, 100/200V (100-220) Ordering Example: GMC-100-AC100/200V (see also page 6) AU-100 1NO+1NC, Side mount Bimetallic style Type GT Class 10A Class 20 Differential Non-differential (-heater) Non-differential (2-heater) Differential Setting ranges (A) Setting ranges (A) 4-50 4-50 9-57 9-57 4-65 4-65 54-80 54-80 65-100 65-100 85-125 85-125 GT- 100 GT- 150 GTK-100 GTK-150 GTH-100/ GTH-150/ GTH-100 GTH-150 GTK-100/L GTK-150/L 100-150

Contactors (100 to 800A) 180A 220A 00A 400A 600A 800A includes 2 AU-100 auxililary switches, (2 N.O. / 2 N.C.) includes 2 AU-100 auxililary switches, (2 N.O. / 2 N.C.) includes 2 AU-100 auxililary switches, (2 N.O. / 2 N.C.) GMC-180 GMC-220 GMC-00 GMC-400 GMC-600 GMC-800 kw A kw A kw A kw A kw A kw A 20 260 50 420 660 900 55 180 75 250 90 00 125 400 190 60 220 800 90 180 12 250 160 00 220 400 0 60 440 800 110 180 12 200 160 250 225 50 0 500 550 720 110 120 12 150 200 220 250 00 0 420 500 60 hp A hp A hp A hp A hp A hp A 20 275 50 450 660 900 15 15 0 40 60 60 100 125 150 250 60 75 100 150 200 00 125 150 200 00 400 600 125 150 200 00 400 600 4 4 5 5 6 7 GMC-180/4 GMC-220/4 GMC-00/4 GMC-400/4 GMC-600/4 GMC-800/4 20 260 50 420 660 800 AC: 100/200 (100-240), 00 (265-47), 400 (80-450), 500V (440-575) DC: 100/200V (100-220) Ordering Example: GMC-180-AC100/200V (see also page 6) AC: 100 (100-127), 200 (200-240), 00 (265-47), 400 (80-450), 500V (440-575) DC: 100 (100-110), 200V (200-220) AU-100 1NO+1NC, Side mount Setting ranges (A) Setting ranges (A) Setting ranges (A) 65-100 85-125 220-00 85-125 100-150 260-400 100-150 120-180 400-600 120-180 160-240 520-800 160-240 220-00 260-400 GT- 220 GT- 400 GT- 800 GTK-220 GTH-220/ GTH-220 GTK-220/L GTK-400 GTH-400/ GTH-400 GTK-400/L GTK-600 GTH-600/ GTH-600 GTK-600/L 4

Mini Contactors and Overloads NO main contacts 1 auxiliary contact For further technical information see page 1. Frame size STANDARD Screw clamp type AC coil DC coil OPTIONAL Fast-on type AC coil DC coil Cage clamp type AC coil DC coil Solder pin type AC coil DC coil Overload Relays Screw clamp type Fast-on type Cage clamp type Solder pin type Ratings / IEC60947-4 kw A kw A kw A kw A AC1 20 20 20 20 AC 200/240V 1.5 7 2.2 9 12 4 15 80/440V 2.2 6 4 9 5.5 12 7.5 16 500/550V 5.7 6 4 7 5.5 9 690V 4 4 5 4 5 4 5 Ratings / UL508 hp A hp A hp A hp A continuous current 20 25 0 2 single phase 115V 0.5 0.5 1 2 20V 1 2 three phase 200V 2 5 7 20V 2 5 7. 5 460V 5 7.5 10 10 575V 7.5 10 15 15 NEMA size 00 00 00 0 Available coil voltages AC 50/60Hz: 24, 6, 42, 48, 110, 115, 120, 127, 200/208, 220, 220/20, 20/240, 256, 277, 80/400, 400, 440, 480, 500, 550, 600V (60Hz) DC: 12, 20, 24, 6, 42, 48, 60, 72, 110, 120, 125, 220, 240, 250V Ordering Example: GMC-6M-10-AC120V (see also page 6) Screw clamp type Fast-on type Cage clamp type Solder pin type Additional Auxiliary Contacts 2-pole, Front mount 4-pole, Front mount 2-pole, Side mount AU-2M AU-4M 6A AU-1M AU-2MF AU-4MF 9A GMC-6M GMC-9M GMC-12M GMC-16M GMD-6M GMD-9M GMD-12M GMD-16M GMC-6MF GMC-9MF GMC-12MF GMC-16MF GMD-6MF GMD-9MF GMD-12MF GMD-16MF GMC-6MC GMC-9MC GMC-12MC GMC-16MC GMD-6MC GMD-9MC GMD-12MC GMD-16MC GMC-6MP GMC-9MP GMC-12MP GMC-16MP GMD-6MP GMD-9MP GMD-12MP GMD-16MP AU-1MF AU-2MC AU-4MC 12A AU-1MC 16A AU-1MP Bimetallic style Type GT Class 10A GT-12M Setting ranges (A) 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.6 0.6-1 1-1.6 1.6-2.5 2.5-4 4-6 5-8 6-9 7-10 9-1 12-16 Base for separate mounting AZ-12H Differential Non-differential (-heater) Non-differential (2-heater) GTK-12M GTH-12M/ GTH-12M See page 6 for how to specify the type of auxiliary switch (N.O. or N.C.). 5 Altech Corp. 5 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490

Contactors Numbering System GM C 6 Coil Voltage Contactor / Starter Device type C Contactor with AC coil D Contactor with DC coil Terminal type of Mini contactor None Screw P Pin F Fast-on C Cage clamp Nominal rating 6 6A 9 9A : : 600 60A 800 800A Contactor type None M Normal (9-800A) Mini type (6-16A) None 10 01 Auxiliary switch type for Mini Contactors Normal (9-800A) 1 N.O. (mini type 6-16A) 1 N.C. Thermal Overload Relay GT K 12 Amperage Range Thermal overload relay K H Protection type Differential current protection Non-differential Nominal rating 12 max 16A 22 max 22A : : 600 max 800A Number of bimetal elements for Non-differential H type None 2 elements elements None H Mounting Standard (mount to contactor) Separate mount Relay type None Normal (max. 800A) M Mini type (max. 16A) Other devices / accessories are available. Consult Altech Corp. for more information. 6

2-pole AC Contactors, Definite Purpose For further technical information see page 14. Description - Two normally open main contacts - Screw clamp or fast-on connections - Small and light design suitable for use in air conditioners, heaters, refrigerators, etc. - Screw mountable - N.O. auxiliary contact - AC control voltage Selection AC ratings AC4 ratings Type 220~ 80~ 500~ 220~ 80~ 500~ 240V 440V 550V 240V 440V 550V AC1 Making Breaking I th current current SMC-20P2 20A 17A 14A 18A 1A 10A 0A 120A 20A SMC-25P2 25A 21A 17A 20A 14A 12A 5A 150A 25A SMC-0P2 0A 2A 21A 22A 20A 14A 40A 180A 0A Connection style Terminal code Main terminal Coil terminal Remarks TSBS Screw clamp Screw clamp TSBQ Fast-on TQBS Screw clamp not available for Fast-on(Quick connect) TQBQ Fast-on(Quick connect) SMC-0P2 Endurance Mechanical lifetime Electrical lifetime at AC at AC4 2 mil. Operations 0.2 mil. Operations (1200 operations/h) 0.015 mil. Operations (600 operations/h) LISTED Contactor coil voltage, AC 50/60Hz 24, 48~50, 110/110~120, 208~220/208~240V Ordering information Specify type, terminal code and coil voltage Example : SMC-25P2, TSBQ, AC110V 50Hz 7

-pole Contactors / AC Coil (Dimensions shown in mm, to convert to inches multiply by 0.097) GMC-9 GMC-12 GMC-18 GMC-22 Optional auxililary contact unit (side mount type) GMC-9 & 12: 0.kg (0.7 lbs.) GMC-18 & 22: 0.7kg (0.82 lbs.) GMC-2 GMC-40 GMC-2 & 40: 0.45kg (0.99 lbs.) GMC-50 GMC-65 GMC-75 GMC-85 GMC-50 to 85: 1kg (2.21 lbs.) GMC-9~22 GMC-2~85 Optional auxililary contact unit 8

-pole Contactors / DC Coil (Dimensions shown in mm, to convert to inches multiply by 0.097) GMD-9 GMD-12 GMD-18 GMD-22 Optional auxililary contact unit (side mount type) GMD-9 &12: 0.55kg (1.21 lbs.) GMD-18 & 22: 0.59kg (1.0 lbs.) GMD-2 GMD-40 GMD-2 & 40: 0.67kg (1.48 lbs.) GMD-50 GMD-65 GMD-75 GMD-85 GMD-50, 65, 75 & 85: 1.06kg (2.4 lbs.) GMD-2, 40 GMD-9~22 GMD-50~85 Optional auxililary contact unit 9

-pole Contactors (Dimensions shown in mm, to convert to inches multiply by 0.097) GMC-100 GMC-125 GMC-100 &125: 2.9kg (6.9 lbs.) GMC-150 GMC-150:.4kg (7.50 lbs.) GMC-180 GMC-220 GMC-180 & 220: 5.4kg (11.91 lbs.) GMC-100-220 Optional auxililary contact unit (side mount type) 10

-pole Contactors (Dimensions shown in mm, to convert to inches multiply by 0.097) GMC-00 GMC-400 GMC-00 & 400: 9.2kg (20.29 lbs.) GMC-600 GMC-800 GMC-600 & 800: 22.4kg (49.9 lbs.) GMC-00-800 11

Thermal Overload Relays (Dimensions shown in mm, to convert to inches multiply by 0.097) GTH-22 GTK-22 GTH-22/ GTH-22, GTK-22 & GTH-22/: 0.11kg (0.24 lbs.) GTH-40 GTK-40 GTH-40/ GTH-22/, 40/, 85/ GTK-22, 40, 85 ( heater types) GTH-40, GTK-40 & GTH-40/: 0.17kg (0.7 lbs.) GTH-85 GTK-85 GTH-85/ GTH-85, GTK-85 & GTH-85/: 0.kg (0.66 lbs.) Separate mounting units for overload relays (Dimensions shown in mm, to convert to inches multiply by 0.097) AZ-22H for use with overload relay GTH(K)-22 Optional auxililary contact unit (side mount type) AZ-22H: 44g (0.097 lbs.) 12

Separate Mounting Units for Overload Relays (Dimensions shown in mm, to convert to inches multiply by 0.097) AZ-40H for use with overload relay GTH(K)-40 AZ-40H: 72g (0.16 lbs.) AZ-85H for use with overload relay GTH(K)-85 Mini Contactors (Dimensions shown in mm, to convert to inches multiply by 0.097) AZ-85H: 144g (0.2 lbs.) GMC-12M 45 57 4. 7 7.7 5 M.5(Coil terminal) M.5 4.5 58 50 7.6 8.7 GMC-12M: 0.17kg (0.7 lbs.) GMD-12M 45 69 55. 7 7.7 5 M.5(Coil terminal) M.5.5 58 50 4 7.6 8.7 GMD-12M: 0.2kg (0.51 lbs.)

2-pole AC Contactors (Dimensions shown in mm, to convert to inches multiply by 0.097) Terminal type :TSBS SMC-20P2 SMC-25P2 SMC-0P2 Terminal type :TQBS SMC-20P2 SMC-25P2 SMC-20P2, 25P2 & 0P2: 0.25kg (0.55 lbs.) Terminal type :TSBQ SMC-20P2 SMC-25P2 SMC-0P2 SMC-20P2 & 25P2: 0.26kg (0.57 lbs.) Terminal type :TQBQ SMC-20P2 SMC-25P2 SMC-20P2, 25P2 & 0P2: 0.25kg (0.55 lbs.) Optional auxililary contact unit (side mount type) SMC-20P2 & 25P2: 0.26kg (0.57 lbs.) 14