Bulletin 193-T1 Bimetallic Overload Relays

Similar documents
MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE

AF40... AF96 3-pole contactors Technical data

Bulletin 100-D IEC Contactors

Thermal Overload Relays

Thermal overload relay TF140DU and TF140DU-V1000

Electronic overload relay EF65, EF96 and EF146

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Thermal overload relay TF65 and TF96

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Electronic overload relays EF205 and EF370

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

MS General Information Extended Product Type: MS

Overloadrelay,10-16A,1N/O+1N/C. Articleno

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

SIRIUS 3RU2 Thermal Overload Relays

Technical Information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

FMotor Circuit Controllers

Thermal Overload Relays - WEG RW Series, 2 Pole

3VU13, 3VU16 Circuit-Breakers

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Bulletin 190-M Compact Starters. Selection Guide

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Application Mini Contactors for Motors and Resistive Loads

Short form catalogue. Motor protection & control

Selection Guide Motor Control Device Solutions

Series KTU7 UL489 Molded Case Circuit Breakers

KT4 Manual Motor Starter

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Protection Equipment

CA Z-EN Overload relays, CT-operated overload relays

Industrial Contactors CTX 3 3P 185A - 800A

Technical data for manual motor starters Type MS325

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

UL/CSA Non-fused Disconnect Switches

Manual motor starter MS116

Ideal for use as a manual starter

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Technical Information

onlinecomponents.com

1489-M Circuit Breakers

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Series L9 UL489 Miniature Circuit Breakers

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

4 - Miniature controls

UL Enclosed Disconnect Switches (Fused and Non-Fused)

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

3 - Protection components Motor circuit-breakers

Manual motor starter MS116

Bulletin 825 SMM Smart Motor Manager

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Series KTU7 UL489 Molded Case Circuit Breakers

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Switches Unlimited Phone: * Fax:

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Application Mini Contactors for Motors and Resistive Loads

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

Control and Load Switch Specifications Bulletin Number 194E, 194L

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

DEVICE STATE/BYPASSED FAILURE OVERLOAD

BETA Switching Switches and Light Indicators

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Manual motor starter magnetic only MO325

D509E. Manual Motor - Starters

ASL09..S 3-pole Contactors - Spring Terminals

Application Description

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

A302DN.40/.63A Thermal Current Motor Starter

Thermal overload relays Type TA Class 10

TAE pole Contactors

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

Manual Motor Starters. Meta-MEC

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Mini contactors B6, BC6 with 3 pole

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Transcription:

Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode selectable Test function for auxiliary contacts Stop button Trip indicator Optional remote reset solenoid and external reset accessories The 193T1 bimetallic overload relays are ambient temperature compensated, ensuring that the tripping characteristic of the relay remains constant over an ambient temperature range of 20 +60 C. These class 10 / 10A overload relays include a differential mechanism for high sensitivity to phase loss conditions and provide reliable motor protection in normal duty applications. In addition, they can be used to protect against overloads in DCmotor and variable frequency drive applications. Standards Compliance IEC/EN 609471, 41, 51 UL508 CSA C22.2 No.14 Certifications culus (File No. E33916, Guide NKCR, NKCR7), CE marked Thermal Overload Relays

For Use With Setting Range [A] Max. Backup fuse [A] Cat. No. gl/gg UL Class K5 50 ka, 690V AC 5 ka, 600V AC IEC/EN 6094741 Coordination UL 508 Type 1 Type 2 100 C09 100 C23 0.1 0.16 50 1 193T1AA16 0.16 0.25 50 1 193T1AA25 0.25 0.40 50 2 1 193T1AA40 0.35 0.50 50 2 2 193T1AA50 0.45 0.63 50 2 2 193T1AA63 0.55 0.80 50 4 3 193T1AA80 0.75 1.0 50 4 3 193T1AB10 0.90 1.3 50 6 4 193T1AB13 1.1 1.6 50 6 5 193T1AB16 1.4 2.0 50 10 8 193T1AB20 1.8 2.5 50 16 10 193T1AB25 2.3 3.2 50 16 12 193T1AB32 2.9 4.0 50 16 15 193T1AB40 3.5 4.8 50 16 15 193T1AB48 4.5 6.3 50 20 20 193T1AB63 5.5 7.5 50 25 25 193T1AB75 7.2 10 50 25 35 193T1AC10 9.0 12.5 50 35 50 193T1AC12 100 C12 100 C23 11.3 16 50 35 60 193T1AC16 100 C16 100 C23 15 20 80 40 80 193T1AC20 17.5 21.5 80 50 80 193T1AC21 100C23 21 25 80 50 100 193T1AC25 100 C30 100 C37 15 20 80 40 80 193T1BC20 17.5 21.5 80 50 80 193T1BC21 21 25 80 50 100 193T1BC25 24.5 30 100 63 100 193T1BC30 29 36 125 63 125 193T1BC36 100C37 33 38 125 63 150 193T1BC38 100 C43 100 C55 17 25 100 50 100 193T1CC25 24.5 36 125 80 125 193T1CC36 35 47 160 100 175 193T1CC47 45 60 200 125 225 193T1CC60 100 C60 100 C97 35 47 160 100 175 193T1DC47 45 60 200 125 250 193T1DC60 100 C72 100 C97 58 75 200 125 300 193T1DC75 100 C72 100 C97 72 90 250 160 350 193T1DC90 Separate mounting required (Panelmounted device) 35 47 160 100 175 193T1DC47P 45 60 200 125 250 193T1DC60P 58 75 200 125 300 193T1DC75P 72 90 250 160 350 193T1DC90P Bulletin 193 T1 overload relays shall not be used with 100 C09 100 C43 conventional DC coil controlled contactors. Use electronic controlled DC coil versions. To select the setting range for use in Y D Starters, multiply the rated operating current of the motor by a factor of 0.58. For motors with service factor of 1.15 or greater, use motor nameplate full load current. For motors with service factor of 1.0, use 90% of the motor nameplate full load current. Max. Back up fuse [A], UL Class K5, 10 ka, 600V AC AddOn Modules

Description For Use With Pkg. Quantity Cat. No. DIN Rail/Panel Mounting Adapter For separate mounting of overload relays Snaps on to 35 mm top hat rail 193T1AA, 193T1AB, 193 T1AC, 193T1BC 1 193T1APM Screw Adapter For screw fixing of the 193T1APM panel adapter (1 required per adapter) 193T1APM 10 140MCN45 Remote Reset Solenoid For remote reset of 193K and 193T1 overload relays 193K, 193T1 (not for 193 T1DC_P) 1 193T1RÄ External Reset Button For enclosed, throughthedoor reset applications. Metal construction, IP66, nonilluminated. Refer to the 800F selection information for additional types. Reset Rod Length 142 mm, adjustable range 141 159 mm All 1 800FMR611 All 1 800FATR08 Reset Adapter Expands the reset target area when using an external reset 193K, 193T1 (not for 193 T1DC_P) 1 193RA3 Must be ordered in multiples of package quantity. Ä Coil Voltage Codes for Remote Reset Solenoid [V] 24 48 110 120 125 220 240 50 Hz D 60 Hz D 50/60 Hz KJ KY KF DC ZJ ZY ZD ZS Marking System Uniform labeling materials for contactors, motor starting equipment, timing relays, and circuit breakers Description Pkg. Quantity Cat. No. Label Sheet 105 selfadhesive paper labels each, 6 x 17 mm 10 100FMS Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover Transparent Cover To be used with marking tag sheets 10 100FMP 100 100FMC Must be ordered in multiples of package quantities. Thermal Overload Relays

Main Circuits Cat. No. Rated isolation voltage U i Rated impulse withstand voltage U imp (between main poles and between main poles and auxiliary circuits) Rated impulse withstand voltage U imp (between auxiliary circuits) 193 T1 690V AC 6kV AC 4kV AC Rated operating voltage U e IEC 690V AC 440V DC UL, CSA 600V AC Rated frequencies [Hz] 50/60 Operational frequencies DC 400 Hz Power dissipation 193T1A, 193T1B up to 0.4 A 7 W 0.5 36 A 6 W 38 A 12 W 193T1C 25 47 A 12 W 193T1D 47 90 A 18 W Control Circuits Cat. No. 193 T1 Rated operating current I e AC15 24V [A] 4 240V [A] 2 400V [A] 1.6 690V [A] 0.15 DC13 24V [A] 2 110V [A] 0.4 220V [A] 0.25 440V [A] 0.08 Thermal Current I th 5 Shortcircuit withstand, Fuse IEC, gl/gg [A] 6 Shortcircuit withstand, circuit breaker 1 ka prospective shortcircuitcurrent [A] 4 Min. contact load for reliable operation UL Rating 15V, 2 ma A600/Q300 Terminations Cat. Nos. Main Circuits Control Circuits Remote Reset 193 T1A 193 T1BC20 T1BC25 193 T1BC30 T1BC38 193 T1C 193 T1D 193 T1APM 193 T1 all 193 T1R Wiring cross section Terminal type Terminal screws M4 M4 M4 M5 M6 M4 M3.5 M3.5 Fine stranded with ferrule 1 conductor [mm2] 2 conductors [mm2] 1.5 4 1.5 4 1.5 4 1.5 4 2.5 10 2.5 16 10 35 1.5 10 1 4 1 4 1 2.5 Solid or coarse stranded 1 conductor [mm2] 2 conductors [mm2] 1.5 6 1.5 6 1.5 6 1.5 6 2.5 16 2.5 25 10 35 1.5 16 1 4 1 4 1 2.5 1 conductor [AWG] 2 conductors [AWG] No. 16 10 No. 16 10 No. 14 10 No. 14 10 No. 10 6 No. 10 6 No. 8 1 No. 16 6 No. 18 12 No. 18 12 No. 16 12 Recommended torque [N m] 1.5... 2.2 1.5... 2.2 2.5 3.5 2.5 3.5 4.5 6 1.8 2.8 1.2 1.2 [lb in] 13 20 13 20 22 31 22 31 40 53 16 25 10.6 10.6 Pozidrive screwdriver No. Size 2 2 2 2 2 2 2 Slotted screwdriver [mm] 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 Hexagon socket screw Size 4

193T1R Remote Reset Operating Limits Maximum Command Impulse 5s AC 50/60 Hz Pickup [x U s ] 0.8.1.1 Dropout [x U s ] DC Pickup [x U s ] 0.7.1.25 Dropout [x U s ] Coil Consumtion AC 50/60 Hz Pickup [VA/W] Holdin [VA/W] DC Pickup [W] 17 (24, 110, 125V) 25 (48V) Holdin [W] 17 (24, 110, 125V) 25 (48V) General Cat. No. Type of Overload Relay Trip Rating (ultimate tripping current) Phase loss sensitivity: Trip rating at phase loss 193 T1 Bimetallic, Ambient Compensated, Phase Loss Sensitive 120% FLA 115% FLA Trip Class 193T1A/T1B 193T1C/T1D IEC/EN 6094741 10A 10 UL 10 Reset Mode Test release Trip indication Compensation temperature range Automatic or Manual Manual release of auxiliary contacts By means of a flag visible through an opening in the relay front 20 +60 C ( 4 +140 F) Climatic Conditions Release Tolerance at 20 C 1.05 1.4 x I n Storage Temperature Range Operating Temperature Range Air moisture (Storage/Operating) 55 +80 C ( 67 +176 F) 20 +60 C ( 4 +140 F) 5 95% rel.humidity, non condensing Vibration (per IEC/EN 6006826), service 3g IEC/EN 61373 (vibration railways) IEC/EN 60092504 (vibration ships), service category 1, class B 0.7 g, all axes, 2 200 Hz Shock (per IEC/EN 68000227), transport 30 g IEC/EN 60068227 (Shock halfsinus), service IEC/EN 61373 (shock railways) 11 ms > 5 g all axes category 1, class B, 5g 30 ms Max. Altitude 2000 m Pollution Degree 3 Degree of Protection, with wires connected IP2X Approximate Weight (unpackaged) 193T1A, 193T1B 0.16 25 A 0.115 kg 193T1B 30 38 A 0.155 kg 193T1C 25 47 A 0.330 kg 193T1D 47 90 A 0.360 kg 193 T1.P 47 90 A 0.415 kg Standards Certifications IEC/EN 604971, 41, 51, UL508, CSA C22.2 No.14 CE, culus Circuit Diagrams

Wiring Schematic Typical IEC Wiring Schematic Trip Characteristics These trip characteristics refer to IEC/EN 60947 4 1 and are average values from cold start at an ambient temperature of 20 C. Trip time is pictured as a function of operating current. With the device at max. operating temperature, the trip time decreases to approximately 25% of the shown value. (a) Tripping characteristics 3poles from the cold state (b) Tripping characteristics 2poles from the cold state Cat. Nos. 193 T1AA16 AA40 Overload Relays Cat. Nos. 193 T1AA50 AB40 Overload Relays

Cat. Nos. 193 T1AB48 AC25 Overload Relays Cat. Nos. 193 T1BC20 BC25 Overload Relays Cat. Nos. 193 T1BC30 BC38 Overload Relays

Cat. Nos. 193 T1CC25 CC47 Overload Relays Cat. Nos. 193 T1DC47 DC90 Overload Relays

Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Cat. Nos. 193 T1AA16 AC25 Overload Relays Cat. Nos. 193 T1BC20 25 Overload Relays Cat. Nos. 193 T1BC30 38 Overload Relays

Cat. Nos. 193 T1CC25 47 Overload Relays Cat. Nos. 193 T1DC47 90 Overload Relays

Cat. Nos. 193 T1DC47P 90P Overload Relays Cat. No. 193T1APM DIN Rail/Panel Mounting Adapter (for use with Cat. Nos. 193 T1AA16 AC25 and 193 T1BC20 25 Overload Relays) Cat. No. 193T1APM DIN Rail/Panel Mounting Adapter

(for use with Cat. No. 193 T1BC30 38 Overload Relays ) Cat. No. 193RA3 Reset Adapter Cat. No. 193T1RÄ Remote Reset Solenoid Copyright 2015 Rockwell Automation, Inc. All Rights Reserved.