Ventilation Solutions

Similar documents
INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

48-INCH (27-INCH DEEP) PRO SERIES WALL HOOD SPECIFICATIONS

48-INCH (24-INCH DEEP) PRO SERIES WALL HOOD SPECIFICATIONS

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

30-INCH (24-INCH DEEP) PRO SERIES WALL HOOD SPECIFICATIONS

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

Viking Installation Guide

RANGE, RANGETOP AND VENTILATION MATRIX PROFESSIONAL SERIES

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

VENTILATION SYSTEM WALL MOUNT CHIMNEY HOODS CHIMNEY HOODS FOR CUSTOM BUILT-IN HOODS

EHD Hoods EHD EHDR EHD09

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Designer Wall Range Hood Installation. Installation Tutorial Video

KITCHEN VENTILATION SOLUTIONS

36 Downdraft Hood Proud Mounting

Pro Island Ventilation Hoods

ERDE36. 1 Top Assembly. 2 Gas Tubing. 3 Gas Tubing Parts. 4 Oven Cell Assembly. 5 Oven Cell Parts. 6 Oven Cell Components. 7 Oven Case Assembly

ERDE48 Range. Description. 2 Top Frame Assembly. 3 Top Assembly. 4 Top Assembly Parts Cell Assembly Cell Components Cell Assembly

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Installation GUIDE. 5 SERIES Professional Indoor Hoods EVWH53048, EVWH53648, EVWH54848

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

KEES, INC. BALANCING MANUAL

Viking Installation Guide

MODERN-AIRE. For the professional or the everyday gourmet, Modern-Aire Ventilating. Range Hoods

ExtractAire. Grease Filters for Commercial Kitchen Ventilation Hoods. Baffle. High Velocity Cartridge (HVC)

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Filter Hood Model CA-S

Model ND-2 Specification

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Installation. Professional Indoor & Outdoor Hoods

CornuFé Series PRICES & SPECIFICATIONS

When Time Matters! listed Fire Damper

Viking Installation Guide

o Brass Trim Option (BR) nameplate,

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

ISLAND INSTALLATION WALL INSTALLATION

Installation Instructions

DCWL Designer Chimney Wall Hood w/ledge*

P R O D U C T G U I D E

ISLAND RANGE HOOD SPECIFICATIONS

Viking Installation Guide

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Viking Installation Guide

VENTILATION. Standard Features & Accessories. Model Options. Designer Built-In Wall Hoods

Viking Installation Guide

INSTALLATION INSTRUCTIONS

Air Handling Unit Fan Selection Guide

Safety & Installation Instructions

Hood. warning. warning. caution

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

ECPD/ECPS Wall Ovens

Malm Fireplaces, Inc.

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

Roof Upblast and Sidewall Exhaust

www. TheRangeHoodStore.com

Accessories Standard Service Fixture Kits

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

FUME HOOD SELECTION GUIDE

36 & 48 ISLAND AND WALL CANOPY RANGE HOODS

Type of Motor & Blower

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Installation Instructions

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

WELD STRONG BREATHE FREE

High Capacity Ventilation

Filtered Kitchen Supply Packaged Ventilator

Optimizing System Performance

Custom Metal Fabrication - HVAC Air Duct and Fittings

Wiring Diagram Owner's Guide Installation Instructions Service Data Sheet

Zoneflow Engineering Installation and Maintenance Manual

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Exhaust hose reels. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. Car and truck dealerships

MODEL FF50 CEILING FAN

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

Transcription:

1 Ventilation Facts POLLUTANTS TO REMOVE FROM THE KITCHEN Heat, Odors, Grease, Gases, Steam & Smoke FACTORS THAT NEGATIVELY INFLUENCE VENTILATION Open Windows & Doors, Air Conditioning Vents, Ceiling Fans, Island Cooking, Foot Traffic GENERAL RULE OF THUMB 100 CFM for every 10,000 BTU (*Increase if duct run is long or complicated) Two Types of Ventilation Power Sources Factors to Consider Width & Depth of Cooking Product 1 OVERHEAD Hoods Powerpacks Over-the-Range Microwaves (OTR) Internal Blowers External Blowers: REMP3, REMP16 ILHSF8, ILHSF10 Capture Area: Width, Height & Depth Mounting Height (see chart) Blower Size Duct Diameter: Use Manufacturer s Recommendation Duct Length (see chart) 2 DOWNDRAFT RV ERV ERV-ER PRV Internal Blowers: CABP3 (RV only) External Blowers: REMP3, REMP16 In-Line Blowers: ILHSF8, ILHSF10 Width & Depth of Cooking Product Blower Size Duct Diameter: Use Manufacturer s Recommendation Duct Length (see chart) HVAC Experts recommend

2 Ventilation Facts Hoods: EH/EHR/MH - Bottom of the hood should be 25 minimum above the cooktop surface. DHI, DHW, PHW - Bottom of the hood should be 30 minimum above the cooktop surface. RECOMMENDED MOUNTING HEIGHTS PowerPacks (with SS Liner): Bottom of liner should be 36" from the finished counter. OTR (above electric cooking): Top of microwave should be 34" above the finished counter. OTR (above gas cooking): Top of microwave should be 36" above the finished counter. (36" mandatory above ERD30, ER30D, ER30DSR and EGR30) *In hoods or Powerpacks, if you must install the hood higher than the recommended height, it is very important that you increase the size (width) of the hood and the power (CFM) to provide the best possible ventilation. Elbows & Transitions count extra-you must add to straight run to get the total duct run. RECOMMENDED DUCT LENGTHS (VARIES BY PRODUCT) 90º, 8" Round=7' 45º, 8" Round=3' 90º, Rectangle=15' 90º, 10" Round=5' 45º, 10" Round=2' 90º, Flat Rectangle Elbow=20' Straight Transition, 8" or 10" Rd to 3 1/4"x10" Rectangle = 4' Elbow Transition, 8" or 10" Rd to 3 1/4"x10" Rectangle = 25' 8" Round: 60' max 10" Round: 50' max 3 1/4"x10" Rectangle: 50' max DO S & DONT S Keep duct run as short as possible. Whenever possible, use round duct instead of rectangle. Do not use back to back elbows 24" minimum between elbows. Do not use flex duct. Do not use duct smaller then the recommended size and never reduce! Seal ductwork with duct tape and use screws to support weight. Match roof or wall cap with duct size. In Pro, Island cooking, we recommend you oversize the hood a minimum of 6". Support and insulate duct to reduce all noise and vibration.

3 Pro-Style Hoods 18" Epicure Hoods 18" High, 26 7 /8" Deep EH5418, EH4818, EH4218, EH3618, EH3018, EHR5418, EHR4818, EHR4218, EHR3618, EHR3018 WIDTHS 54", 48, 42, 36 and 30 FINISHES Stainless Steel in standard Chrome trim. Three trim finish options are available in Black Chrome, Brass or Copper. INTERL POWERED EH MODELS 600 CFM (582 CFM at - EH4218, EH3618 & EH3018 1200 CFM (1164 at - EH5418, EH4818 EXTERL POWERED EHR MODELS (REMOTE BLOWER OPTION) - only one blower allowed per installation) EHR3018 or EHR3618- Use REMP3 or REMP16; ILHSF8 or ILHSF10 EHR4218, EHR4818 or EHR5418 Use REMP16 or ILHSF10 Vents out the top (vertically) or back (horizontally) 42, 36 & 30 hoods 8 round single outlet 54 & 48 hoods 8 round dual outlets, may use AHT10 to transition into a single 10 round exhaust CONTROLS Hood switch will control integrated or remote blowers at 4 speed settings DUCT COVERS Available in all standard widths 6," 12" or 18" heights 12" Epicure Hoods 12" High, 26 7 /8" Deep EH4812, EH4212, EH3612, EH3012 EHR4812, EHR4212, EHR3612, EHR3012 WIDTHS 48, 42, 36 and 30 FINISHES Stainless Steel in standard Chrome trim. Three trim finish options are available in Black Chrome, Brass or Copper. INTERL POWERED EH MODELS 600 CFM (582 CFM at - EH4212 or EH3612 or EH3012 1200 CFM (1164 at - EH4812 EXTERL POWERED EHR MODELS (REMOTE BLOWERS OPTIONonly one blower allowed per installation) EHR4212 or EHR3612 or EHR3012 - Use REMP3; ILHSF8 EHR4812 - Use REMP16; ILHSF10 Vents out the top (vertically) or back (horizontally) 30", 36" or 42" hoods single outlet 48 hoods 8 round dual outlets, may use AHT10 to transition into a single 10 round exhaust CONTROLS Hood switch will control integrated or remote blowers at 4 speed settings DUCT COVERS Available in all standard widths 6," 12" or 18" heights

4 Millennia Hoods 18" Millennia Hoods 18" High, 25 1 /2" Deep MH4818, MH3618, MH3018 WIDTHS FINISH 48", 36 and 30 Stainless Steel INTERL POWERED MH MODELS 600 CFM (582 CFM at - MH3618 or MH3018 1200 CFM (1164 at - MH4818 Vents out the top (vertically) or back (horizontally) 36 & 30 hoods- 8 round single outlet 48 8 round dual outlets, may use AHT10 to transition into a single 10 round exhaust CONTROLS Hood switch will control integrated blowers at 4 speed settings. DUCT COVERS Available in all standard widths 6," 12" or 18" heights 12" Millennia Hoods 12" High, 25 1 /2" Deep MH4812, MH3612, MH3012 WIDTHS 48", 36 and 30 FINISH Stainless Steel INTERL POWERED MHD MODELS 600 CFM (582 CFM at MH3012 or MH3612 1200 CFM (1164 at MH4812 Vents out the top (vertically) or back (horizontally) 36" & 30" hoods single outlet 48" hoods - dual outlets, may use AHT10 to transition into a single 10" round exhaust CONTROLS Hood switch will control integrated blowers at 4 speed settings DUCT COVERS Available in all standard widths - 6," 12" or 18" heights

5 Blower Performance Curves ø 146mm 4-speed EH and MH Hoods Centrifugal Blower Static pressure - inches of water 2.40 2.10 1.80 1.50 Speed Speed Speed 1 1 1 1 Static pressure - inches of water 2.00 1.75 1.50 1.25 2 1.20 Speed Speed Speed 4 4 Speed Speed 3 3 3 Speed 2 2 1.00.90.75 Speed Speed Speed 2 Speed Speed Speed 1.60.50 Speed 3.30.25 Speed Speed Speed 4 0 0 65 130 195 260 325 390 455 545 50 100 150 200 250 300 350 400 Static pressure - inches of water 2.00 1.75 1.50 1.25 Speed Speed Speed 1 3 Static pressure - inches of water 2.40 2.10 1.80 1.50 Speed Speed Speed 2 2 2 Speed Speed 1 1 1 1 1.00 Speed Speed 2 1.20 Speed Speed 4 4 Speed Speed 3 3 3.75 Speed Speed 3.90.50 Speed Speed 4.60.25.30 0 0 50 100 150 200 250 300 350 400 65 130 195 260 325 390 455 545

6 Millennia Hoods Millennia Island Hoods - DHI602, DHI542, DHI482, DHI421, DHI361 WIDTHS 60, 54, 48, 42 & 36 FINISH Stainless Steel INTERL POWERED 1200 CFM (1164 at - DHI602, DHI542, DHI482 600 CFM (582 CFM at - DHI421, DHI361 Vents out the top (vertically), 8 round Millennia Chimney Hoods - DHW482, DHW421, DHW361, DHW301 WIDTHS 48, 42, 36 & 30 FINISH Stainless Steel INTERL POWERED 1200 CFM (1164 at - DHW482-1200 CFM 600 CFM (582 CFM at - DHW421, DHW361 & DHW301 Vents out the top (vertically), 8 round Millennia Chimney Hoods PHW plus choice of PHG36 or PHG30 Glass WIDTHS 36" & 30" FINISHES PHW is in Stainless and must order the Glass Canopy either PHG36 or PHG30 in 6 Preference Color Options: Anthracite Gray (AG), Titanium Silver (TS), Sterling Grey (SG), Slate Green (GN), Blue Water (BU) and Black (BK) to complete the hood. INTERL POWERED 600 CFM (582 CFM at - PHW + PHG36+ Color Choice 600 CFM (582 CFM at - PHW + PHG30+ Color Choice Vents out the top (vertically), 8 round

7 PowerPacks IVS1 or IVSR1 DIMENSIONS 22 5 8" wide, 12 1 4" deep, 6" high INTERL POWERED IVS1 600 CFM (582 CFM at EXTERL POWERED IVSR1 (REMOTE BLOWER OPTION - only one blower allowed per installation) Use REMP3 600 CFM Use ILHSF8 600 CFM (572 at Vents out the top (vertically) OPTIOL STAINLESS STEEL LINERS IHL36 for 36" Decorative Hoods IHL30 for 30" Decorative Hoods IVS2 or IVSR2 DIMENSIONS 34 1 2" wide, 12 1 4" deep, 6" high INTERL POWERED IVS2 1200 CFM (1164 at EXTERL POWERED IVSR2 (REMOTE BLOWER OPTION - only one blower allowed per installation) Use REMP16 1000 CFM Use ILHSF10 1100 CFM (1053 at Vents out the top (vertically) (2) ducts Use Dacor ATD10 transition to (1) 10" round exhaust OPTIOL STAINLESS STEEL LINERS IHL54 for 54" Decorative Hoods IHL48 for 48" Decorative Hoods IHL42 for 42" Decorative Hoods

8 Blower Performance Curve IVS1 IVS1 Static pressure - inches of water.75.60.45.30.15 0 100 200 300 400 500 600 Airflow CFM (Cubic feet/minute)

9 Over the Range Microwaves PMOR3021 FINISHES Stainless Steel, Black or White INTERL POWERED 300 CFM EXTERL POWERED (OPTIOL REMOTE BLOWER) INSTALLER 600 CFM Use ILHSF8 600 CFM (572 at Remove OTR fan blower Recommended if using above ERD30, ER30D, ER30DSR or EGR30 Pro Ranges Vents out the top (vertically) or the back (horizontally) 3 1 4" x 10" rectangle duct SPECIAL NOTES Factory set for NON-VENTED MODE (Recirculating before installation) Must turn motor 1/4 turn to change to VENTED Only "UL" approved Over the Range Microwave/Hood to go over 30" wide gas or electric products. Must use deflector shield (supplied) and proper mounting height. PCOR30 Convection Model FINISHES Stainless Steel, Black or White INTERL POWERED 300 CFM EXTERL POWERED (OPTIOL REMOTE BLOWER) INSTALLER 600 CFM Use ILHSF8 600 CFM (572 at Remove OTR fan blower Recommended if using above ERD30, ER30D, ER30DSR or EGR30 Pro Ranges Vents out the top (vertically) or the back (horizontally) 3 1 4" x 10" rectangle duct SPECIAL NOTES Factory set for NON-VENTED MODE (Recirculating before installation) Must turn motor 1/4 turn to change to VENTED Only "UL" approved Over the Range Microwave/Hood to go over 30" wide gas or electric products. Must use deflector shield (supplied) and proper mounting height.

10 Downdraft Systems RV46, RV36, RV30 SIZES 46," 36" & 30" FINISHES Stainless Steel, Black or White INTERL POWERED Use CABP3 blower 600 CFM EXTERL POWERED (REMOTE BLOWER OPTION - only one blower allowed per installation) REMP3 600 CFM, duct REMP16 1000 CFM, 10" round duct ILHSF8-600 CFM (572 at, 8 round duct ILHSF10-1100 CFM (1053 at, 10 round duct Three options: right or left sides, or bottom SPECIAL NOTES See page 12, 13 and 16 for selection of products to match this downdraft system. ERV30/36/48, ERV36-ER, ERV48-ER SIZES 48" 36" & 30" FINISHES Stainless Steel only EXTERL POWERED (REMOTE BLOWER OPTION - only one blower allowed per installation) REMP3 600 CFM, duct REMP16 1000 CFM, 10" round duct ILHSF8-600 CFM (572 at, 8 round duct ILHSF10-1100 CFM (1053 at, 10 round duct Transition ATD-2 included Four optional exhaust directions: right or left sides, bottom or back SPECIAL NOTES See page 12, 13 and 16 for selection of products to match this downdraft system. ERV48-ER is designed for ER48D Range only ERV36-ER is designed for ER36D Range only PRV46, PRV36, PRV30 SIZES 46," 36" & 30" FINISHES Stainless Steel, Black or White EXTERL POWERED (REMOTE BLOWER OPTION - only one blower allowed per installation) REMP3 600 CFM, duct REMP16 1000 CFM, 10" round duct ILHSF8-600 CFM (572 at, 8 round duct ILHSF10-1100 CFM (1053 at, 10 round duct Transition ATD-2 included Four optional exhaust directions: right or left sides, bottom or back SPECIAL NOTES See page 12, 13 and 16 for selection of products to match this downdraft system.

11 Accessories Remote Blower Internal Blower REMP3 (shown) - 600 CFM REMP16-1,000 CFM APPLICATIONS: Use with EHR, IVSR, RV, ERV or PRV systems CABP3-600 CFM APPLICATIONS: Install with RV model downdrafts only Stainless Steel Liners for PowerPacks SIZES Available in five widths: 54," 48," 42," 36" & 30" IHL36 & IHL30 Use with IVS1 & IVSR1 Stainless Steel Duct Covers SIZES Available in five widths: 54," 48," 42," 36" & 30"All widths available in three heights: 6," 12" & 18 IHL54, IHL48 & IHL42 Use with IVS2 & IVSR2 Transition Duct Transition Duct ATD10 Use with all IVS2 & IVSR2. Use with EHD, EHDR4809, EHDR4209 & MHD4809. Used to connect dual exhaust into a single 10" round exhaust. Remote Control Speed Switch ARSC Install as remote control for all blower systems except EH/EHR/MH Hoods ARLC To control lights except EH/EHR/MH Hoods ARSLC To control both blower & lights except EH/EHR/MH Hoods AHT10 Use with EH5418, EHR5418, EH4818, EHR4818, EH4812, EHR4812, MH4818, & MH4812. Used to connect dual exhaust into a single 10" round exhaust.

12 Blower Performance Curve REMP3 Static pressure - inches of water 4.00 3.50 3.00 2.50 REMP3 2.00 1.50 1.00.50 0 100 200 300 400 500 600 700 Airflow CFM (Cubic feet/minute)

13 In-Line Blowers ILHSF8 POWER 600 CFM (572 at duct APPLICATIONS In-line Blower for a remote application MAKE-UP OR REPLACEMENT AIR SYSTEM Have your builder contact their HVAC contractor to see if this is required in your area. ILHSF10 POWER 1100 CFM (1053 at 10" round duct APPLICATIONS In-line Blower for a remote application MAKE-UP OR REPLACEMENT AIR SYSTEM Have your builder contact their HVAC contractor to see if this is required in your area.

14 Creating the Proper Ventilation System 1 Select Cooking Product COOKING PRODUCT MODEL HOOD INTEGRATED VENT SYSTEM OVER THE RANGE (OTC) RAISED VENT SYSTEM ER48D EH5418 or EHR5418 EH4818 or EHR4818 EH4812 or EHR4812 MH4818, MH4812 DHI542, DHI482, DHW482 IVS2 or IVSR2 Plus IHL54 or IHL48 ERV48-ER (must use remote ER36D EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618 EH3612 or EHR3612 MH3618, MH3612 DHI421, DHI361 DHW421, DHW361 PHW+PHG36+Color IVS2 or IVSR2 + IHL42 IVS1 or IVSR1 + IHL36 ERV36-ER (must use remote ER30DSR ER30D ERD30 EGR30 EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012 MH3618 or MH3018 MH3612 or MH3012 DHI361 DHW361, DHW301 PHW+PHG36+Color PHW+PHG30+Color IVS1 or IVSR1 + IHL36 IVS1 or IVSR1 + IHL30 PCOR30 or PMOR3021 with ILHSF8 and ARSC (with deflector shield) ERV30 with ERD30, ER30DSR (EGR30 not approved for use with downdraft) (must use remote ESG486 EG486 EH5418 or EHR5418 EH4818 or EHR4818 EH4812 or EHR4812 MH4818, MH4812 DHI542, DHI482, DHW482 IVS2 or IVSR2 Plus IHL54 or IHL48 ERV48 (must use remote ESG366 EG366 EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618 EH3612 or EHR3612 MH3618, MH3612 DHI421, DHI361, DHW421, DHW361 IVS2 or IVSR2 + IHL42 IVS1 or IVSR1 + IHL36 ERV36 (must use remote SGM466 EH4818 or EHR4818 EH4812 or EHR4812 MH4818, MH4812 DHI482, DHW482 IVS2 or IVSR2 Plus IHL54 or IHL48 RV46 (CABP3 or remote PRV46 (must use remote

15 Creating the Proper Ventilation System 2 Selecting Cooking Product COOKING PRODUCT MODEL HOOD INTEGRATED VENT SYSTEM OVER THE RANGE (OTR) RAISED VENT SYSTEM RGC365 SGM365 EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618 EH3612 or EHR3612 MH3618 or MH3612 DHI421 or DHI361 DHW421 or DHW361 PHW+PHG36+Color IVS2 or IVSR2 + IHL42 IVS1 or IVSR1 + IHL36 ERV36 or RV36 (with appropriate remote PRV36 (must use remote RGC304 SGM304 EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012 MH3618 or MH3612 MH3018 or MH3012 DHI361 DHW361 or DHW301 PHW+PHG36+Color PHW+PHG30+Color IVS1 or IVSR1 + IHL36 or IHL30 PCOR30 or PMOR3021 (add ILHSF8 & ARSC if you want 600 CFM) ERV30 or RV30 (with appropriate PRV30 (must use remote METB365-1 ETT365-2 EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618 EH3612 or EHR3612 MH3618 or MH3612 DHI421or DHI361 DHW421 or DHW361 PHW+PHG36+Color IVS2 or IVSR2 + IHL42 IVS1 or IVSR1 + IHL36 ERV36 or RV36 (with appropriate PRV36 (must use remote MET304 ETT304-1 EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012 MH3618 or MH3612 MH3018 or MH3012 DHI361 DHW361 or DHW301 PHW+PHG36+Color PHW+PHG30+Color IVS1 or IVSR1+ IHL36 or IHL30 PCOR30 or PMOR3021 (add ILHSF8 & ARSC if you want 600 CFM) ERV30 or RV30 (with appropriate PRV30 (must use remote MRES30S EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012 MH3618 or MH3612 MH3018 or MH3012 DHI361 DHW361 or DHW301 PHW+PHG36+Color PHW+PHG30+Color IVS1 or IVSR1+ IHL36 or IHL30 PCOR30 or PMOR3021 (add ILHSF8 & ARSC if you want 600 CFM) ERV30 (must use remote PRV30 (must use remote

16 Creating the Proper Ventilation System 3 Build the Ventilation Package STEP: 1 2 3 4 5 Select Vent System/ Model VENT SYSTEMS MODEL INTERL POWER Select Blower REMOTE POWER Duct Size Needed (minimum) DUCT SIZE Max Length for 1 Blower System MAX LENGTH Determine Duct Length Incl. Elbows & Trans. DUCT LENGTH COMMENTS EH4218 EH3618 EH3018 Included 600 CFM (582 at (one) 60' 18" Pro Hood Internal Blower EH5418 EH4818 Included 1200 CFM (1164 at (two) AHT10 may be used to transition to a single 10" duct exhaust 50' for 10" 60' for 8" Ask builder about make-up air EHR4218 EHR3618 EHR3018 REMP3 REMP16 ILHSF8 ILHSF10 (one) 60' Only one blower is allowed 18" Pro Hood External Blower EHR5418 EHR4818 REMP16 or ILHSF10 (two) AHT10 may be used to transition to a single 10" duct exhaust 50' for 10" 60' for 8" Ask builder about make-up air. Only one blower is allowed. EH4212 EH3612 EH3012 Included 600 CFM (582 at (one) 60' 12" Pro Hood Internal Blower EH4812 Included 1200 CFM (1164 at (two) AHT10 may be used to transition to a single 10" duct exhaust 50' for 10" 60' for 8" Ask builder about make-up air EHR4212 EHR3612 EHR3012 REMP3 REMP16 ILHSF8 ILHSF10 (one) 60' Only one blower is allowed 12" Pro Hood External Blower EHR4812 REMP16 ILHSF10 (two) AHT10 may be used to transition to a single 10" duct exhaust 50' for 10" 60' for 8" Ask builder about make-up air. Only one blower is allowed.

17 Creating the Proper Ventilation System 4 Build the Ventilation Package Select Vent System/ Model VENT SYSTEMS 1 2 3 4 5 MODEL INTERL POWER Select Blower REMOTE POWER Duct Size Needed (minimum) DUCT SIZE Max Length for 1 Blower System MAX LENGTH Determine Duct Length Incl. Elbows & Trans. DUCT LENGTH COMMENTS MH3618 MH3018 Included 600 CFM (582 at (one) 60' 18" Millennia Wall Mounted Hood MH4818 Included 1200 CFM (1164 at (two) AHT10 may be used to transition to a single 10" exhaust 50' for 10" 60' for 8" Ask builder about make-up air MH3612 MH3012 Included 600 CFM (582 at (one) 60' 12" Millennia Wall Mounted Hood MH4812 Included 1200 CFM (1164 at (two) AHT10 may be used to transition to a single 10" exhaust 50' for 10" 60' for 8" Ask builder about make-up air Millennia Island Hood DHI602 DHI542 DHI482 Included 1200 CFM (1164 at 50' DHI421 DHI361 Included 600 CFM (582 at 60' Millennia Chimney Hood DHW482 Included 1200 CFM (1164 at DHW421 DHW361 DHW301 Included 600 CFM (582 at Preference Hood PHW + PHG36 OR PHG30 (colored glass) Included 600 CFM (582 at 50'

18 Creating the Proper Ventilation System 5 Build the Ventilation Package STEP: 1 2 3 4 5 6 Select Vent System/ Model VENT SYSTEMS MODEL INTERL POWER Select Blower REMOTE POWER Select Liner & Transition Duct Size Needed (minimum) LINER TRANSITION DUCT SIZE Max Length for 1 Blower System MAX LENGTH Determine Duct Length Incl. Elbows & Trans. DUCT LENGTH COMMENTS IVS1 Included 600 CFM (582 at IHL36 or IHL30 60' Ask builder about make-up air PowerPacks Internal & External IVS2 IVSR1 Included 1200 CFM (1164 at REMP3 ILHSF8 IHL54, IHL48 IHL42 or IHL40 IHL36 or IHL30 ATD10 10" round 50' 60' IVSR2 REMP16 ILHSF10 IHL54, IHL48 IHL42 or IHL40 ATD10 10" round 50' Ask builder about make-up air Over the Range Microwaves PMOR3021 PCOR30 Included 300 CFM ILHSF8 & ARSC (if used with ERD30, ER30D, ER30DSR or EGR30) 3 1 /4" x 10" rectangle 40' Remove internal blower if using the ILHSF8 & ARSC combination Downdraft RV RV30 CABP3 REMP3 REMP16 ILHSF8 ILHSF10 3 1 /4" x 10" rectangle 40' Ask builder about makeup air if unit is over 1000 CFM Downdraft ERV ERV48 ERV36 ERV30 ERV48-ER ERV36-ER REMP3 REMP16 ILHSF8 ILHSF10 3 1 /4" x 10" rectangle 40' Ask builder about makeup air if unit is over 1000 CFM Downdraft PRV PRV46 PRV36 PRV30 REMP3 REMP16 ILHSF8 ILHSF10 3 1 /4" x 10" rectangle 40' Ask builder about makeup air if unit is over 1000 CFM

Copyright 2008 Dacor, Inc. All rights reserved. L65348 090208 800.793.0093 www.dacor.com