LMF / LMG RANGE ACCESSORIES CONTENTS

Similar documents
LMV RANGE CONTENTS. General information


MG RANGE CONTENTS. General Specification Shell Styles... 4, 5, 6. Ordering Information Connectors... 7

EDGECARD CONNECTORS CONTENTS

LMJ RANGE CONTENTS. Description and characteristics Shell Styles Ordering Information - Connectors... 7

HT STRAIGHT ADAPTER, WRENCH FLATS ( )

06xx024S - STRAIGHT SHRINK BOOT ADAPTER, NON-DETENT SELF LOCKING 06xx024Y - ONE PIECE SHRINK BOOT ADAPTER, NON-DETENT SELF LOCKING

SCE. Snatch Connector Electrical Series

Assembly instruction APD 6-/7-way

MIL-DTL-38999Series III Composite Series

Amphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003

Amphenol 97 Series MIL-DTL-5015

MIL-DTL 38999Series III Aluminium Series

Waterproof Series Waterproof

PART NUMBER BREAKDOWN CP A 70 1 W D H - 10

POLAMCO HIGH POWER CONNECTORS STYLE

Amphenol 62GB solder connectors

97 series crimp type plugs with solid shells

MMC RTX series EN3716

AB05 Series Miniature Bayonet Coupling Connectors

- - Introduction. Specifications

HBB power connector. Product description

FISCHER FREEDOM TM SERIES

Assembly Instructions-C12 Amphenol Triax BNC, 180 Polarity

ABG Cable Glands Installation Procedure

8D Series D38999 Composite Series

ABCIRH. Connectors. Halogen Free Bayonet Lock Connector Series

sira CERTIFICATION KSG, KSGDS and KCG Range of Cable Glands

RSK Connectors and Installation Tools

8D Series D38999 Composite Series

MIL-DTL Series 1 Solder Type PT

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

A-L810 Steady-Burning Red LED Obstruction Light Installation and Maintenance Manual

CYLER. Catalogue. Cyler Technology Limited cylerconnectors. Push-Pull connectors

Amphenol GB- Series Plugs Miniature Bayonet Lock Connectors Complies with MIL-C CE-2Pa

AMPLIMITE* HDP- 20 and Economy

THREADED & BAYONET CONNECTORS FOR DEMANDING ENVIRONMENTS

8D Series D38999 Aluminum Series

SMB LOCK Introduction Characteristics Straight plugs Right angle plugs SMB limited detent (SMB-A) Receptacles...

High Performance, Microminiature Circular Connectors

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

IECEx Certificate of Conformity

MS C O N N E C T O R S MS-6/898

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

High Performance, Microminiature Circular Connectors

Termination Procedure for 723 Series SolderTacts Contacts for Coaxial Cable: D , D

Rated Current. Test Voltage

MD CONNECTOR. 1Certified LR Miniature circular connectors. Standards

SEALSAFE PRODUCTS CONDUIT AND CABLE PRODUCTS. for HARSH AND HAZARDOUS ENVIRONMENTS. Certificate ANZEx

Track Rollers/ Cam Followers

MIL-C (Series 1, 2, 3 & 4) Updated February 2013 (Rev )

HYDROCON Standard Sealed Connectors

DB Series Single/Multi Way Bayonet Coupled Connectors. Data Bus Interconnection System

22kV 425 AMP KA STYLE COUPLER 224BKA - Range

Ethernet Buccaneer BUCCANEER DATA. bulgin

SMA CONTENTS PAGE 9-3

WIRING INSTRUCTIONS FOR IT-FRIT (MIL-DTL-C-5015G) AND ITB-ITS-FRITS (VG95234) CONNECTORS

9316 series Underwater applications Explosion proof Hermetically sealed

Coaxial Snap-Lock Connectors

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC

Series 801 Mighty Mouse Double-Start ACME Threads Crimp Receptacle

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA

PLASTI-GRIP* Terminals and Splices

Brass Compression Fitting Range

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

17 TW SERIES. Hybrid Connector SPECIFICATIONS: MATERIALS AND PLATINGS ELECTRICAL DATA CLIMATIC DATA MECHANICAL DATA

2M Accessories, Contacts, and Tools. 2M Accessories, Contacts, and tools. Page Guide. Accessories. Micro Contacts Tools

A driving force in the market place

AE40 CATALOG D38999 CYLINDRICAL CONNECTORS FOR PCB APPLICATIONS

ADJUSTABLE CABLE GLANDS

RF Coaxial Connectors SMZ (Type 43)

... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MCX CONNECTORS

RF COAXIAL CONNECTORS, TYPE SMA, 50 OHMS (FEMALE CONTACT) ESCC Detail Specification No. 3402/002

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Rapid push-in fittings for plastic tubes Series 1000

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

Compression Fittings. Brass Compression Fittings. Stainless Steel Compression Fittings. PL Nickel-Plated Brass Spigot Fittings

TIDALFLUX 2300 F Quick Start

Data Sheet No 241 Jan 2002 Issue G. Electrode Holders & Brackets for Conductivity Type Systems

AMPLIMITE Cable Connector Accessories

Explosion proof RTD assembly T15

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

EN3716 SAE AS81659 ARINC

Cover headline Cover headline CGE / VG96929 High Power Connectors

AMPLIMITE.050 Series Cable Assemblies, Series III

Cartridge Heaters W A T L O W FIREROD. Cartridge Heaters

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Amphenol s 2M Micro38999 Connector Series The New Aerospace Standard

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

stainless steel compression fittings

Rittal CM Compact System Enclosures

CONNECTORS - SINGLE POLE

RTD Assembly TH15. Compact Instructions. KA195R/24/ae/

Amphenol RF Interconnects

Product Data For FARNELL

SERIES TAP-CHANGER

THREE-VALVE BATH & SHOWER Cast Brass Body

D X X - XX - XX - X X

Transcription:

CONTENTS Application of Cable Entry Fittings..... Ordering Information... 4 Outlet Accessory Sets..... 5-7 Protective Caps for Aluminium Range.. 8 Protective Caps for Brass Range (Brass)..... 9 Protective Caps for Brass Range (Polythene) 10 Outlet Nuts... 11 Conduit Adaptors.. 1 Tools 1 Wiring Instruction 14-16 Accessory Part Number Index... 17 Product Safety Information........... 18

APPLICATION OF CABLE ENTRY FITTINGS CABLE ENTRY FITTINGS To assist in ordering the correct fittings for a specific cable, pages 5 to 7 illustrate COMPLETE OUTLET ACCESSORY SETS for various sizes and types of cable. Accessory sets other than those shown on pages 5 to 7 may be supplied to order on consultation. SEALING Cable entry fittings ensure sound sealing provided that the correct size of recommended fittings is used with each specific cable. Sealing is effected by either the union gasket or the sealing ring at the rear end of the outlet and by the outlet gasket at the front end. It may be necessary to increase the cable diameter to effect a seal at the rear end of the outlet. ASSEMBLING The special tools shown on page 1 should be used to tighten locking rings, outlet nuts, etc. Cable clamp jaws should be tightened sufficiently to grip the cable, but over-tightening may cause the dielectric to flow and impair its insulating qualities. DIMENSIONS All dimensions with the exception of Imperial threads are in millimetres and are nominal, they are derived from original Imperial dimensions.

ORDERING INFORMATION EXAMPLE LMA/1/10601/ 0 Range prefix (LMA for LMF/LMG Accessories) 1 Accessory Set Single Part 5 digit number specific for each Accessory Special variants Standard for Outlet Accessory Sets 0 Standard for Protective Caps and remaining Accessories Finish / plating 01 Cadmium Olive Drab* 0 Clean Finish (unplated) 04 Electroless Nickel 05 Cadmium Plate and Passivate** 1 Zinc Cobalt Olive Drab Zinc Cobalt Plate and Passivate 8 Zinc Cobalt Black * for LMG Range connectors only ** for LMF Range brass connectors only Other variants available. Please contact Weald Electronics. For special variants please contact Weald Electronics.

OUTLET ACCESSORY SET FOR MULTICORE CABLE TOTALLY UNSCREENED For assembly instruction see page 14. Where no min. cable O/D is shown, sleeve cable to max. O/D to achieve seal. ALUMINIUM BRASS Shell Size 1 1 Cable O/D Outlet Accessory Set with Union Nut Outlet Accessory Set with Cable Clamp Min. mm Max. mm Straight Outlet Rt. Angled Outlet Straight Outlet Rt. Angled Outlet 5.90 7.40 LMA/1/10601/** LMA/1/10505/** LMA/1/1065/** LMA/1/1059/** a 7.50 8.90 LMA/1/1060/** LMA/1/10506/** LMA/1/1066/** LMA/1/1050/** b - 9.0 x 6.70 LMA/1/1060/** LMA/1/10507/** LMA/1/1067/** LMA/1/1051/** b 5.90 7.40 LMA/1/10604/** LMA/1/10508/** LMA/1/1068/** LMA/1/105/** c 7.50 10.0 LMA/1/10605/** LMA/1/10509/** LMA/1/1069/** LMA/1/105/** d 8.80 11.0 LMA/1/10606/** LMA/1/10510/** LMA/1/1060/** LMA/1/1054/** e - 11.60 LMA/1/10607/** LMA/1/10511/** LMA/1/1061/** LMA/1/1055/** f - 1.10 LMA/1/10608/** LMA/1/1051/** LMA/1/106/** LMA/1/1056/** f - 11.60 LMA/1/10609/** LMA/1/1051/** LMA/1/106/** LMA/1/1057/** g - 1.10 LMA/1/10610/** LMA/1/10514/** LMA/1/1064/** LMA/1/1058/** g - 17.60 LMA/1/10611/** LMA/1/10515/** LMA/1/1065/** LMA/1/1059/** h 14.60 17.40 LMA/1/0040/** LMA/1/0044/** ----------- ----------- h - 17.60 LMA/1/1061/** LMA/1/10516/** LMA/1/1066/** LMA/1/10540/** i 14.60 17.40 LMA/1/0041/** LMA/1/0045/** ----------- ----------- i 5.90 7.40 LMA/1/1061/** LMA/1/10517/** LMA/1/1067/** LMA/1/10541/** a 7.50 8.90 LMA/1/10614/** LMA/1/10518/** LMA/1/1068/** LMA/1/1054/** b - 9.0 x 6.70 LMA/1/10615/** LMA/1/10519/** LMA/1/1069/** LMA/1/1054/** b 5.90 7.40 LMA/1/10616/** LMA/1/1050/** LMA/1/10640/** LMA/1/10544/** c 7.50 10.0 LMA/1/10617/** LMA/1/1051/** LMA/1/10641/** LMA/1/10545/** d 8.80 11.0 LMA/1/10618/** LMA/1/105/** LMA/1/1064/** LMA/1/10546/** e - 11.60 LMA/1/10619/** ----------- LMA/1/1064/** ----------- f - 1.10 LMA/1/1060/** ----------- LMA/1/10644/** ----------- f - 11.60 LMA/1/1061/** LMA/1/1055/** LMA/1/10645/** LMA/1/10549/** g - 1.10 LMA/1/106/** LMA/1/1056/** LMA/1/10646/** LMA/1/10550/** g - 17.60 LMA/1/106/** LMA/1/1057/** LMA/1/10647/** LMA/1/10551/** h 14.60 17.40 LMA/1/004/** LMA/1/0046/** ----------- ----------- h - 17.60 LMA/1/1064/** LMA/1/1058/** LMA/1/10648/** LMA/1/1055/** i 14.60 17.40 LMA/1/004/** LMA/1/0047/** ----------- ----------- I Code Use this chart to select the correct outlet accessory set to suit the type and size of cable and the shell size of plug or socket being used. ** Final figures of suffix must be added to the part number when ordering: 01 LMG Range, cadmium olive drab plate, aluminium or brass 0 LMF and LMG Range, clean finish, aluminium or brass 05 LMF Range, cadmium plate and passivate, brass For more plating options refer to page 4

OUTLET ACCESSORY SET FOR MULTICORE CABLE WITH OUTER COLLECTIVE SCREEN ONLY For assembly instruction see page 15. ALUMINIUM BRASS Shell Size Cable O/D Outlet Accessory Set with Min. mm Max. mm Straight Outlet Rt. Angled Outlet 1 7.10 9.40 LMA/1/074/** LMA/1/0759/** a 7.10 9.40 LMA/1/0746/** LMA/1/076/** c 9.90 11.70 LMA/1/0748/** LMA/1/0765/** d 11.40 1.0 LMA/1/0750/** LMA/1/0767/** e 1.50 14.60 LMA/1/075/** LMA/1/0770/** f 11.70 1.50 LMA/1/0754/** LMA/1/0771/** 9 1.50 14.60 LMA/1/0756/** LMA/1/077/** 9 17.40 19.0 LMA/1/0757/** LMA/1/0774/** h 17.40 19.0 LMA/1/0911/** LMA/1/0775/** i 1 7.10 9.40 LMA/1/0915/** LMA/1/09/** a 7.10 9.40 LMA/1/0919/** LMA/1/096/** c 9.90 11.70 LMA/1/091/** LMA/1/098/** d 11.40 1.0 LMA/1/09/** ----------- e 1.50 14.60 LMA/1/096/** ----------- f 11.70 1.50 LMA/1/097/** LMA/1/0944/** g 1.50 14.60 LMA/1/099/** LMA/1/0946/** g 17.40 19.0 LMA/1/0905/** LMA/1/0100/** h 17.40 19.0 LMA/1/090/** LMA/1/0947/** i Code Use this chart to select the correct outlet accessory set to suit the type and size of cable and the shell size of plug or socket being used. ** Final figures of suffix must be added to the part number when ordering: 01 LMG Range, cadmium olive drab plate, aluminium or brass 0 LMF and LMG Range, clean finish, aluminium or brass 05 LMF Range, cadmium plate and passivate, brass For more plating options refer to page 4

OUTLET ACCESSORY SET FOR MULTICORE CABLE WITH ALL INDIVIDUALLY SCREENED LEADS AND NO COLLECTIVE SCREEN OR FOR MULTICORE CABLE WITH INNER COLLECTIVE SCREEN For assembly instruction see page 16. Where no min. cable O/D is shown, sleeve cable to max. O/D to achieve seal. ALUMINIUM BRASS Shell Size 1 1 Cable O/D Outlet Accessory Set with Union Nut Outlet Accessory Set with Cable Clamp Min. mm Max. mm Straight Outlet Rt. Angled Outlet Straight Outlet Rt. Angled Outlet 5.9 7.4 LMA/1/080/** LMA/1/08044/** LMA/1/1455/** LMA/1/141/** a 7.5 8.9 LMA/1/0805/** LMA/1/08046/** LMA/1/1456/** LMA/1/14/** b --- 9. x 6.7 LMA/1/0804/** LMA/1/08045/** LMA/1/1457/** LMA/1/14/** b 5.9 7.4 LMA/1/0806/** LMA/1/08047/** LMA/1/1458/** LMA/1/144/** c 7.5 10. LMA/1/0807/** LMA/1/08048/** LMA/1/1459/** LMA/1/145/** d 8.8 11. LMA/1/0808/** LMA/1/08049/** LMA/1/1460/** LMA/1/146/** e --- 11.6 LMA/1/0809/** LMA/1/08050/** LMA/1/1461/** LMA/1/147/** f --- 1.1 LMA/1/08040/** LMA/1/08051/** LMA/1/146/** LMA/1/148/** f --- 11.6 LMA/1/08041/** LMA/1/0805/** LMA/1/146/** LMA/1/149/** g --- 1.1 LMA/1/0804/** LMA/1/0805/** LMA/1/1464/** LMA/1/1440/** g --- 17.6 LMA/1/0804/** LMA/1/149/** LMA/1/1465/** LMA/1/1441/** h 14.6 17.4 LMA/1/0064/** LMA/1/0068/** ----------- ----------- h --- 17.6 LMA/1/1454/** LMA/1/140/** LMA/1/1466/** LMA/1/144/** i 14.6 17.4 LMA/1/0065/** LMA/1/0069/** ----------- ----------- i 5.9 7.4 LMA/1/149/** LMA/1/1467/** LMA/1/1504/** LMA/1/1480/** a 7.5 8.9 LMA/1/149/** LMA/1/1468/** LMA/1/1505/** LMA/1/1481/** b --- 9. x 6.7 LMA/1/1494/** LMA/1/1469/** LMA/1/1506/** LMA/1/148/** b 5.9 7.4 LMA/1/1495/** LMA/1/1470/** LMA/1/1507/** LMA/1/148/** c 7.5 10. LMA/1/1496/** LMA/1/1471/** LMA/1/1508/** LMA/1/1484/** d 8.8 11. LMA/1/1497/** LMA/1/147/** LMA/1/1509/** LMA/1/1485/** e --- 11.6 LMA/1/1498/** ----------- LMA/1/1510/** ----------- f --- 1.1 LMA/1/1499/** ----------- LMA/1/1511/** ----------- f --- 11.6 LMA/1/1500/** LMA/1/1475/** LMA/1/151/** LMA/1/1488/** g --- 1.1 LMA/1/1501/** LMA/1/1476/** LMA/1/151/** LMA/1/1489/** g --- 17.6 LMA/1/150/** LMA/1/1477/** LMA/1/1514/** LMA/1/1490/** h 14.6 17.4 LMA/1/0066/** LMA/1/0070/** ----------- ----------- h --- 17.6 LMA/1/150/** LMA/1/1478/** LMA/1/1515/** LMA/1/1491/** i 14.6 17.4 LMA/1/0067/** LMA/1/0071/** ----------- ----------- i Code Use this chart to select the correct outlet accessory set to suit the type and size of cable and the shell size of plug or socket being used. ** Final figures of suffix must be added to the part number when ordering: 01 LMG Range, cadmium olive drab plate, aluminium or brass 0 LMF and LMG Range, clean finish, aluminium or brass 05 LMF Range, cadmium plate and passivate, brass For more plating options refer to page 4

PROTECTIVE CAPS FOR ALUMINIUM RANGE (FINE THREAD) FOR FREE PLUGS OR SOCKETS Shell Size Code Part Number 1 a b LMA/1/047/0** c d LMA/1/048/0** e f LMA/1/049/0** g LMA/1/0440/0** h i LMA/1/0441/0** FOR FREE COUPLER PLUGS OR SOCKETS Shell Size Code Part Number 1 a b LMA/1/045/0** c d LMA/1/045/0** e f LMA/1/0454/0** g LMA/1/0455/0** h i LMA/1/0456/0** FOR FIXED PLUGS OR SOCKETS Shell Size Part Number 1 LMA/1/044/0** LMA/1/044/0** LMA/1/0444/0** POLYTHENE CAP ONLY FOR FIXED PLUGS OR SOCKETS, FREE COUPLER PLUGS OR SOCKETS Shell Size Part Number 1 LMA//410 LMA//4104 LMA//4105 Note: All protective caps on this page are for use with aluminium connectors (fine thread) only. ** Final figures of suffix must be added to the part number when ordering: 01 LMG Range, cadmium olive drab plate, aluminium or brass 0 LMF and LMG Range, clean finish, aluminium or brass For more plating options refer to page 4

PROTECTIVE CAPS FOR BRASS RANGE (COARSE THREAD) FOR FREE PLUGS OR SOCKETS Shell Size Code Part Number 1 a b LMA/1/04111/0** c d LMA/1/0411/0** e f LMA/1/0411/0** g LMA/1/04114/0** h i LMA/1/04115/0** FOR FREE COUPLER PLUGS OR SOCKETS Shell Size Code Part Number 1 a b LMA/1/0414/0** c d LMA/1/0415/0** e f LMA/1/0416/0** g LMA/1/0417/0** h i LMA/1/0418/0** FOR FIXED SQUARE FLANGE PLUGS OR SOCKETS Shell Size Part Number 1 LMA/1/04116/0** LMA/1/04117/0** LMA/1/04118/0** FOR FIXED ROUND FLANGE PLUGS OR SOCKETS Shell Size Part Number 1 LMA/1/4108/0** LMA/1/4109/0** LMA/1/4110/0** Note: All protective caps on this page are for use with brass connectors (coarse thread) only. ** Final figures of suffix must be added to the part number when ordering: 01 LMG Range, cadmium olive drab plate, aluminium or brass 0 LMF and LMG Range, clean finish, aluminium or brass 05 LMF Range, cadmium plate and passivate, brass For more plating options refer to page 4

PROTECTIVE CAPS (POLYTHENE) FOR BRASS RANGE (COARSE THREAD) Shell Size Code FOR FREE PLUGS OR SOCKETS Assembly Part Number Polythene Cap Only 1 a b LMA/1/41150/0** LMA//4117 c d e f g h i LMA/1/4115/0** LMA/1/41151/0** LMA/1/41154/0** LMA/1/4115/0** LMA//4117 LMA//41174 Shell Size FOR FREE COUPLER PLUGS OR SOCKETS Code Assembly Part Number Polythene Cap Only 1 a b LMA/1/04119/0** LMA//41181 c d e f g h i LMA/1/0410/0** LMA/1/0411/0** LMA/1/041/0** LMA/1/041/0** LMA//4118 LMA//4118 FOR FIXED SQUARE FLANGE PLUGS OR SOCKETS Shell Size Assembly Part Number Polythene Cap Only 1 LMA/1/41160/0** LMA//41181 LMA/1/41161/0** LMA//4118 LMA/1/4116/0** LMA//4118 FOR FIXED ROUND FLANGE PLUGS OR SOCKETS Shell Size Assembly Part Number Polythene Cap Only 1 LMA/1/41198/0** LMA//41181 LMA/1/41199/0** LMA//4118 LMA/1/4100/0** LMA//4118 Note: All protective caps on this page are for use with brass connectors (coarse thread) only. ** Final figures of suffix must be added to the part number when ordering: 01 LMG Range, cadmium olive drab plate, aluminium or brass 0 LMF and LMG Range, clean finish, aluminium or brass 05 LMF Range, cadmium plate and passivate, brass For more plating options refer to page 4

OUTLET NUTS FOR USE WITH LMF & LMG CONNECTORS ON ALUMINIUM OR BRASS FREE UNITS, BRASS FREE COUPLERS & BRASS FIXED UNITS (SQUARE FLANGE) Shell Size Aluminium Part No. Brass Part No. Thread dia. x 6 T.P.I. B.S. 84 1 LMA//07519/0** LMA//07569/0** 0.7969 LMA//0750/0** LMA//07570/0** 1.0156 LMA//0751/0** LMA//07571/0** 1.406 FOR USE WITH LMF ALUMINIUM CONNECTORS ONLY ON FREE COUPLERS & FIXED UNITS WITH OUTLET NUT Shell Size Part No. Thread dia. x 6 T.P.I. B.S. 84 1 LMA//40978/0** 0.9687" LMA//40980/0** 1.1875" LMA//40981/0** 1.565" FOR USE WITH LMG CONNECTORS ONLY ON ALUMINIUM FREE COUPLERS & FIXED UNITS (ROUND FLANGE) Shell Size Aluminium Part No. Brass Part No. Thread dia. x 6 T.P.I. B.S. 84 1 LMA//0751/0** LMA//07157/0**.847" LMA//075/0** LMA//07158/0** 1.065" LMA//075/0** LMA//07159/0** 1.475" Note: ** Final figures of suffix must be added to the part number when ordering: 01 LMG Range, cadmium olive drab plate, aluminium or brass 0 LMF and LMG Range, clean finish, aluminium or brass 05 LMF Range, cadmium plate and passivate, brass For more plating options refer to page 4

CONDUIT ADAPTORS A limited range of brass conduit adaptors which provide the facility to terminate 0mm conduit to standard LMF or LMG connectors with straight or right angled outlets. ACCESSORY SET Shell Size Cable dia. max. Straight outlet Right angled outlet Code 1 11.0 LMA/1/8010/** LMA/1/80105/** b 1.60 LMA/1/8010/** LMA/1/80106/** e 15.90 LMA/1/80104/** LMA/1/80107/** g CONDUIT ADAPTOR Shell Size Part No. A B min. C Thread dia. x 6TPI BS 84 1 LMA/1/80099/0**.00 11.0 0.6406" b LMA/1/80100/0**.00 1.59 0.744" e LMA/1/80101/0** 5.0 15.87 0.847" g Code Note: ** Final figures of suffix must be added to the part number when ordering: 01 LMG Range, cadmium olive drab plate, aluminium or brass 0 LMF and LMG Range, clean finish, aluminium or brass 05 LMF Range, cadmium plate and passivate, brass For more plating options refer to page 4

TOOLS TOOLS REQUIRED FOR LOCKING CABLE ENTRY FITTINGS AND FOR MOUNTING FIXED UNITS TO PANELS, ETC. COMPLETE TOOL KIT Description Complete tool kit (not in case) Part No. LMT/1/0070 PART No. LMT/1/0070 comprises: Special spanner, shell size 1 Special spanner, shell size Special spanner, shell size Tommy bar special spanner Bodyholder shell size 1 Bodyholder shell size Bodyholder shell size Double-ended spanner, shell size 1 Double-ended spanner, shell size Double-ended spanner, shell size LMT//00574 LMT//00575 LMT//00576 LMT//0057 LMT/1/0061 LMT/1/006 LMT/1/006 LMT//00564 LMT//00565 LMT//00566 SPECIAL SPANNER (SHOWN WITH TOMMY BAR) Used on fixed units, including bulkheads, to facilitate tightening of panel locking rings. DOUBLE-ENDED SPANNER Used in conjunction with body holder to facilitate tightening of outlet nuts and panel locking rings. BODYHOLDER Used in conjunction with double-ended spanner - locates on front face of connectors.

WIRING INSTRUCTION MULTICORE CABLE TOTALLY UNSCREENED 1. Strip back outer sheath. Strip insulation from each conductor and tin dip. Thread on to cable: union nut / cable clamp, thrust ring (or packing piece), union gasket, outlet nut, outlet and outlet gasket. Fit insulation sleeves to conductors.. Solder conductors to connector contacts. Slide insulation sleeves over solder joints. Position outlet gasket and outlet at rear of connector and secure with outlet nut. Slide union gasket into neck of outlet. Screw clamp on to outlet. Secure union nut / cable clamp to cable by screwing down clamp jaw.

WIRING INSTRUCTION MULTICORE CABLE WITH OUTER COLLECTIVE SCREEN ONLY 1. Strip back braid and sheath. Strip insulation from conductors and tin dip. Thread on union nut and outer ferrule. Thread on inner ferrule and position under braid. Fit insulating sleeves to each conductor.. Force outer ferrule over inner ferrule and braid. Trim off any braid which may protrude between ferrule flanges. Compress the braid back down cable. Thread on sealing ring, outlet nut, outlet and outlet gasket. Solder conductors to connector contacts and slide insulation sleeves over joints.. Position outlet gasket and outlet at rear of connector and secure with outlet nut. Slide sealing ring into neck of outlet. Pull forward ferrules and braid, secure with union nut.

WIRING INSTRUCTION MULTICORE CABLE WITH INNER COLLECTIVE SCREEN ONLY 1. Strip outer sheath and braid. Thread on union nut / cable clamp, thrust ring (or packing piece), union gasket (see note), compression ring and cable sleeve. Comb out metal braid, fold back over sheath and tape down. Strip insulation from conductors and tin dip. Thread on outlet nut, outlet, and outlet gasket. Fit insulating sleeves to each conductor. NOTE: Union gasket requires to be a close fit to cable sheath. Synthetic rubber sleeve/s to be fitted to achieve a satisfactory fit.. Solder conductors to connector contacts and slide insulating sleeves over soldered joints. Position outlet gasket and outlet at rear of connector and secure with outlet nut. Slide cable sleeve into neck of outlet.. Remove tape from metal braid and fan out 90 to cable. Position compression ring on end of outer sheath trapping braid between outlet and compressions ring. Slide forward union gasket and thrust ring to rear of compression ring. Trim off braid, to rear face of compression ring and screw union nut / cable clamp onto outlet.

Line No. Part No. Page No. Line No. LMF / LMG RANGE ACCESSORY PART NUMBER INDEX Part No. Page No. Line No. Part No. Page No. Line No. Part No. 1 LMA/1/074/** 6 85 LMA/1/0809/** 7 169 LMA/1/1066/** 5 5 LMA/1/1506/** 7 LMA/1/0746/** 6 86 LMA/1/08040/** 7 170 LMA/1/1067/** 5 54 LMA/1/1507/** 7 LMA/1/0748/** 6 87 LMA/1/08041/** 7 171 LMA/1/1068/** 5 55 LMA/1/1508/** 7 4 LMA/1/0750/** 6 88 LMA/1/0804/** 7 17 LMA/1/1069/** 5 56 LMA/1/1509/** 7 5 LMA/1/075/** 6 89 LMA/1/0804/** 7 17 LMA/1/1060/** 5 57 LMA/1/1510/** 7 6 LMA/1/0754/** 6 90 LMA/1/08044/** 7 174 LMA/1/1061/** 5 58 LMA/1/1511/** 7 7 LMA/1/0756/** 6 91 LMA/1/08045/** 7 175 LMA/1/106/** 5 59 LMA/1/151/** 7 8 LMA/1/0757/** 6 9 LMA/1/08046/** 7 176 LMA/1/106/** 5 60 LMA/1/151/** 7 9 LMA/1/0759/** 6 9 LMA/1/08047/** 7 177 LMA/1/1064/** 5 61 LMA/1/1514/** 7 10 LMA/1/076/** 6 94 LMA/1/08048/** 7 178 LMA/1/1065/** 5 6 LMA/1/1515/** 7 11 LMA/1/0765/** 6 95 LMA/1/08049/** 7 179 LMA/1/1066/** 5 6 LMA/1/0040/** 5 1 LMA/1/0767/** 6 96 LMA/1/08050/** 7 180 LMA/1/1067/** 5 64 LMA/1/0041/** 5 1 LMA/1/0770/** 6 97 LMA/1/08051/** 7 181 LMA/1/1068/** 5 65 LMA/1/004/** 5 14 LMA/1/0771/** 6 98 LMA/1/0805/** 7 18 LMA/1/1069/** 5 66 LMA/1/004/** 5 15 LMA/1/077/** 6 99 LMA/1/0805/** 7 18 LMA/1/10640/** 5 67 LMA/1/0044/** 5 16 LMA/1/0774/** 6 100 LMA/1/10505/** 5 184 LMA/1/10641/** 5 68 LMA/1/0045/** 5 17 LMA/1/0775/** 6 101 LMA/1/10506/** 5 185 LMA/1/1064/** 5 69 LMA/1/0046/** 5 18 LMA/1/0905/** 6 10 LMA/1/10507/** 5 186 LMA/1/1064/** 5 70 LMA/1/0047/** 5 19 LMA/1/0911/** 6 10 LMA/1/10508/** 5 187 LMA/1/10644/** 5 71 LMA/1/0064/** 7 0 LMA/1/0915/** 6 104 LMA/1/10509/** 5 188 LMA/1/10645/** 5 7 LMA/1/0065/** 7 1 LMA/1/0919/** 6 105 LMA/1/10510/** 5 189 LMA/1/10646/** 5 7 LMA/1/0066/** 7 LMA/1/091/** 6 106 LMA/1/10511/** 5 190 LMA/1/10647/** 5 74 LMA/1/0067/** 7 LMA/1/09/** 6 107 LMA/1/1051/** 5 191 LMA/1/10648/** 5 75 LMA/1/0068/** 7 4 LMA/1/096/** 6 108 LMA/1/1051/** 5 19 LMA/1/149/** 7 76 LMA/1/0069/** 7 5 LMA/1/097/** 6 109 LMA/1/10514/** 5 19 LMA/1/140/** 7 77 LMA/1/0070/** 7 6 LMA/1/099/** 6 110 LMA/1/10515/** 5 194 LMA/1/141/** 7 78 LMA/1/0071/** 7 7 LMA/1/090/** 6 111 LMA/1/10516/** 5 195 LMA/1/14/** 7 79 LMA//40978/00 11 8 LMA/1/09/** 6 11 LMA/1/10517/** 5 196 LMA/1/14/** 7 80 LMA//40980/00 11 9 LMA/1/096/** 6 11 LMA/1/10518/** 5 197 LMA/1/144/** 7 81 LMA//40981/00 11 0 LMA/1/098/** 6 114 LMA/1/10519/** 5 198 LMA/1/145/** 7 8 LMA/1/41150/00* 10 1 LMA/1/0944/** 6 115 LMA/1/1050/** 5 199 LMA/1/146/** 7 8 LMA/1/41151/00* 10 LMA/1/0946/** 6 116 LMA/1/1051/** 5 00 LMA/1/147/** 7 84 LMA/1/4115/00* 10 LMA/1/0947/** 6 117 LMA/1/105/** 5 01 LMA/1/148/** 7 85 LMA/1/4115/00* 10 4 LMA/1/0100/** 6 118 LMA/1/1055/** 5 0 LMA/1/149/** 7 86 LMA/1/41154/00* 10 5 LMA/1/047/** 8 119 LMA/1/1056/** 5 0 LMA/1/1440/** 7 87 LMA/1/41160/00* 10 6 LMA/1/048/** 8 10 LMA/1/1057/** 5 04 LMA/1/1441/** 7 88 LMA/1/41161/00* 10 7 LMA/1/049/** 8 11 LMA/1/1058/** 5 05 LMA/1/144/** 7 89 LMA/1/4116/00* 10 8 LMA/1/0440/** 8 1 LMA/1/1059/** 5 06 LMA/1/1454/** 7 90 LMA//4117 10 9 LMA/1/0441/** 8 1 LMA/1/1050/** 5 07 LMA/1/1455/** 7 91 LMA//4117 10 40 LMA/1/044/** 8 14 LMA/1/1051/** 5 08 LMA/1/1456/** 7 9 LMA//41174 10 41 LMA/1/044/** 8 15 LMA/1/105/** 5 09 LMA/1/1457/** 7 9 LMA//41181 10 4 LMA/1/0444/** 8 16 LMA/1/105/** 5 10 LMA/1/1458/** 7 94 LMA//4118 10 4 LMA/1/0440/** 8 17 LMA/1/1054/** 5 11 LMA/1/1459/** 7 95 LMA//4118 10 44 LMA/1/045/** 8 18 LMA/1/1055/** 5 1 LMA/1/1460/** 7 96 LMA/1/41198/00* 10 45 LMA/1/045/** 8 19 LMA/1/1056/** 5 1 LMA/1/1461/** 7 97 LMA/1/41199/00* 10 46 LMA/1/0454/** 8 10 LMA/1/1057/** 5 14 LMA/1/146/** 7 98 LMA/1/4100/00* 10 47 LMA/1/0455/** 8 11 LMA/1/1058/** 5 15 LMA/1/146/** 7 99 LMA/1/4108/00* 9 48 LMA/1/0456/** 8 1 LMA/1/1059/** 5 16 LMA/1/1464/** 7 00 LMA/1/4109/00* 9 49 LMA/1/04111/00* 9 1 LMA/1/10540/** 5 17 LMA/1/1465/** 7 01 LMA/1/4110/00* 9 50 LMA/1/0411/00* 9 14 LMA/1/10541/** 5 18 LMA/1/1466/** 7 0 LMA//410 8 51 LMA/1/0411/00* 9 15 LMA/1/1054/** 5 19 LMA/1/1467/** 7 0 LMA//4104 8 5 LMA/1/04114/00* 9 16 LMA/1/1054/** 5 0 LMA/1/1468/** 7 04 LMA//4105 8 5 LMA/1/04115/00* 9 17 LMA/1/10544/** 5 1 LMA/1/1469/** 7 05 LMA/1/80099/00* 1 54 LMA/1/04116/00* 9 18 LMA/1/10545/** 5 LMA/1/1470/** 7 06 LMA/1/80100/00* 1 55 LMA/1/04117/00* 9 19 LMA/1/10546/** 5 LMA/1/1471/** 7 07 LMA/1/80101/00* 1 56 LMA/1/04118/00* 9 140 LMA/1/10549/** 5 4 LMA/1/147/** 7 08 LMA/1/8010/** 1 57 LMA/1/04119/00* 10 141 LMA/1/10550/** 5 5 LMA/1/1475/** 7 09 LMA/1/8010/** 1 58 LMA/1/0410/00* 10 14 LMA/1/10551/** 5 6 LMA/1/1476/** 7 10 LMA/1/80104/** 1 59 LMA/1/0411/00* 10 14 LMA/1/1055/** 5 7 LMA/1/1477/** 7 11 LMA/1/80105/** 1 60 LMA/1/041/00* 10 144 LMA/1/10601/** 5 8 LMA/1/1478/** 7 1 LMA/1/80106/** 1 61 LMA/1/041/00* 10 145 LMA/1/1060/** 5 9 LMA/1/1480/** 7 1 LMA/1/80107/** 1 6 LMA/1/0414/00* 9 146 LMA/1/1060/** 5 0 LMA/1/1481/** 7 14 LMT/1/0061 1 6 LMA/1/0415/00* 9 147 LMA/1/10604/** 5 1 LMA/1/148/** 7 15 LMT/1/006 1 64 LMA/1/0416/00* 9 148 LMA/1/10605/** 5 LMA/1/148/** 7 16 LMT/1/006 1 65 LMA/1/0417/00* 9 149 LMA/1/10606/** 5 LMA/1/1484/** 7 17 LMT/1/0070 1 66 LMA/1/0418/00* 9 150 LMA/1/10607/** 5 4 LMA/1/1485/** 7 18 LMT//00564 1 67 LMA//07157/00* 11 151 LMA/1/10608/** 5 5 LMA/1/1488/** 7 19 LMT//00565 1 68 LMA//07158/00* 11 15 LMA/1/10609/** 5 6 LMA/1/1489/** 7 0 LMT//00566 1 69 LMA//07159/00* 11 15 LMA/1/10610/** 5 7 LMA/1/1490/** 7 1 LMT//00574 1 70 LMA//07519/00* 11 154 LMA/1/10611/** 5 8 LMA/1/1491/** 7 LMT//00575 1 71 LMA//0750/00* 11 155 LMA/1/1061/** 5 9 LMA/1/149/** 7 LMT/00576 1 7 LMA//0751/00* 11 156 LMA/1/1061/** 5 40 LMA/1/149/** 7 7 LMA//0750/00* 11 157 LMA/1/10614/** 5 41 LMA/1/1494/** 7 74 LMA//075/00* 11 158 LMA/1/10615/** 5 4 LMA/1/1495/** 7 75 LMA//075/00* 11 159 LMA/1/10616/** 5 4 LMA/1/1496/** 7 76 LMA//07569/00* 11 160 LMA/1/10617/** 5 44 LMA/1/1497/** 7 77 LMA//07570/00* 11 161 LMA/1/10618/** 5 45 LMA/1/1498/** 7 78 LMA//07571/00* 11 16 LMA/1/10619/** 5 46 LMA/1/1499/** 7 79 LMA/1/080/** 7 16 LMA/1/1060/** 5 47 LMA/1/1500/** 7 80 LMA/1/0804/** 7 164 LMA/1/1061/** 5 48 LMA/1/1501/** 7 81 LMA/1/0805/** 7 165 LMA/1/106/** 5 49 LMA/1/150/** 7 8 LMA/1/0806/** 7 166 LMA/1/106/** 5 50 LMA/1/150/** 7 8 LMA/1/0807/** 7 167 LMA/1/1064/** 5 51 LMA/1/1504/** 7 84 LMA/1/0808/** 7 168 LMA/1/1065/** 5 5 LMA/1/1505/** 7 Popular assemblies only listed. For other assemblies please contact Sales. Page No.

PRODUCT SAFETY INFORMATION These notes are intended to be used in conjunction with the Product Catalogue and Product Specification. Products may be safely used in the applications for which they have been designed and within the specified rating and environments. If products are exposed to conditions outside the performance ratings or specified environments they may constitute a hazard. In particular it should be noted that:- 1. Material Content Circular Connectors generally use metalwork parts made of brass, aluminium, phosphor-bronze or steel, which, dependant on the particular application, may be passivated and protected with cadmium or zinc plate in conjunction with chromated or anodised surface finishes. The insulating materials can either be natural or synthetic rubber, together with plastic or glass-filled plastic moulded parts. Contact materials vary but are usually made of brass, phosphor-bronze, alumel or chromel.. Electric Shock, Burns and Fire Hazard can occur if the product is used outside the specified parameters or if the product is damaged, wrongly wired, poorly assembled, poorly integrated into larger equipments, or contaminated with conductive fluids. Live circuit terminations must be protected and live circuits never broken by disconnecting products. Hot spots may be created when resistance is increased due to damage or incorrect integration particularly soldering, or loose terminations. Overheating can cause breakdown of insulation, electric shock, burns or, ultimately, fire. In the event of fire noxious and/or toxic fumes may be released and, in these circumstances, any fire involving the product should be dealt with by personnel properly equipped. Connectors with exposed terminations or contacts should not be used on the current supply side of a circuit with exposed contacts on an unmated product. Before making a circuit live, the product and wiring should be checked to ensure there is no electrically conducting debris present. Circuit resistance checks should also be conducted before making the circuit live. Always ensure that connectors are assembled and wired by properly trained personnel.. Use, Transport and Storage of Products Care must be exercised to avoid damage to any part of the products during transporting, storage or use. Abnormal transit or storage conditions and abuse during installation can give rise to damage. Products should not be used in a damaged condition. Improper storage (particularly of damaged products) can give rise to additional hazards particularly corrosion. Attention is specifically drawn to the need for proper storage of products containing cadmium and you are advised to see the Guidance Note from the Health and safety Executive on Cadmium Health and Safety Precautions. 4. Disposal of Products Product should not be burnt. SAFETY RULES 1. FOLLOW THE GUIDELINES GIVEN.. ALWAYS PROTECT LIVE CIRCUITS AND NEVER DISCONNECT A LIVE CONNECTOR.. NEVER USE A DAMAGED CONNECTOR. 4. NEVER BURN DISCARDED CONNECTORS.