Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9") 105 Corporate Drive, Suite E Spartanburg, SC 29303 PO Box 2889, Spartanburg, SC 29304 USA Tel: 864-599-6340 Fax: 864-599-6344 e-mail: info@ltg-inc.net Internet: http://www.ltg-inc.net LTG Aktiengesellschaft Grenzstrasse 7, D-70435 Stuttgart PO Box 40 05 25, D-70405 Stuttgart Germany Tel: 49-711-8201-0 Fax: 49-711-8201-696 e -mail: prozessluft@ltg-ag.de Internet: http://www.ltg-ag.de TM-USA-TP-01 (05/09) 450-43
LTG Tangential Fans - an advantage for optimum heating, cooling, drying, blasting Many production processes require a linear extended and absolutely even distribution of air or other gases to the working area. Because of their special design, tangential fans meet this requirements in the best possible way. The rigid design and the use of high quality materials secure a long service life. By the working principle, that does away with additional baffles and vanes and the space saving design, the use of tangential fans is very economic. Flow principle The air intake of tangential fans takes place over the whole length of the outer impeller periphery. The air then flows into the impeller interior where it is reversed and accelerated by the vortex caused by the impeller rotation. Finally the air is distributed at the discharge side over the whole impeller length. In this way the air flows through the impeller first from outside to inside and then from inside to outside. The impeller is a cylindrical cage of forward curved impeller blades with two or more supporting discs. The vortex separates suction side and discharge side at the narrowest line between impeller and vortex inducer and causes the flow pattern together with the scroll. The Innovation Company Advantages Uniform air flow over the entire fan width. Additional baffles, plenums and guide vanes are not required. Space saving due to a 90 airflow deflection. The fan width can be exactly matched to the machine width. The air flow pattern does not change with wider machines (simplifies design and drawings of modular systems). Works equally well in any arrangement (right hand drive or left hand drive available). Low noise operation due to aerodynamic design based on 25 years experience. Impeller bearings out of air flow. Many bolt -on options. Fields of application Examples of some fields of application are: Bakeries, drying systems, industrial ovens, packaging industry, cooling and refrigeration systems, department stores, automotive industry, agricultural machines, surface treatment, control panels, hardening shops, textile engineering, swimming pools, air treatment, papermaking industry, environment simulation, chemical industry, industrial processing engineering, dust collection, electrical equipment. impeller vortex inducer scroll E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 3
LTG Tangential Fan Type TM 125 Gas temperature -15 F upto+160 F (- 25 C upto+70 C) The tangetial fan Type TM is a fan with close coupled motor and enhanced corrosion protection. Range Operating conditions Gas temperatures: - 15 _Fuptomax.+160_F(-25 Cuptomax.+70 C) Ambient temperatures: - 15 _Fuptomax.+105_F(-25 Cuptomax.+40 C) for the drive side with motor and - 15 _Fuptomax.+160_F(-25 Cuptomax.+70 C) for the counter side. Type TMR 125/400/N TML 125/400/N TMR 125/600/N TML 125/600/N TMR 125/0/N TML 125/0/N TMR 125/0/N TML 125/0/N max. medium temperatures - 15 _F to + 160 _F - 25 _C to + 70 _C - 15 _F to + 160 _F - 25 _C to + 70 _C - 15 _F to + 160 _F - 25 _C to + 70 _C - 15 _F to + 160 _F - 25 _C to + 70 _C Impeller length 15.75 inch (400 mm) 23.62 inch (600 mm) 31.50 inch (0 mm) 39.37 inch (0 mm) Casing Impeller Motor 2pole or 2pole or Tangential fan Type TMR 125 (right hand motor) note: TMR = right hand motor, TML = left hand motor E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 4
LTG Tangential Fan Type TM 125 Specification and design features Tangential fan with close coupled, spray water protected drive motor with terminal box. Rigid bolted, corrosion proof casing of. Side elements of stainless (1.4541). Impeller of. On the drive side the impeller is bedded via an elastic coupling directly on the motorshaft, on the counterside it is bedded in a ball bearing mounted vibration dampened. Bearing design life is 25000 hours. Intake and discharge openings have sealing planes to connect exactly to ducts and appliances. The complete fan is balanced to grade G 6.3 according to DINISO 1940/1. Dimensions and performance data 105 105 35 50 50 35 Dimensions in mm 8x8 17x8 Tolerances acc. to DIN ISO 2768 -cl 121 194 25 25 184.8 112 72 22 92.4 92.4 22 50 50 22 F D 9 210 L A M 14 25 14 Type TMR 125/400/N TML 125/400/N TMR 125/600/N TML 125/600/N TMR 125/0/N TML 125/0/N TMR 125/0/N TML 125/0/N TMR 125/400/N TML 125/400/N TMR 125/600/N TML 125/600/N Dimensions A L M D F 25 635 32.87 835 40.75 1035 48.62 1235 27.8 706 31.73 6 15.75 400 23.62 600 31.5 0 39.37 0 15.75 400 13.62 600 8.27 210 8.27 210 8.27 210 8.27 210 11.06 281 11.06 281 6.38 162 7.13 181 7.83 199 7.83 199 6.38 162 7.16 181 4.72 120 5.04 128 5.31 135 5.31 135 4.72 120 5.04 128 Air Volume V max [cfm] [m 3 /h] 1089 1850 1648 20 2207 3750 2708 4600 2207 3750 3296 5600 Speed n max [rpm] 1450 1450 1450 1450 2920 2920 Power Consump.* max [hp] [kw] 0.34 0.25 0.37 5 0.48 4 2 2.44 1.8 3 2.2 Masses [lb] [kg] 23 1 32 14.5 42 19 53 24 29 13 38 17 E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 5
LTG Tangential Fan Type TM 150 Gas temperature -15 F upto+160 F (- 25 C upto+70 C) The tangential fan Type TM is a fan with close coupled motor and enhanced corrosion protection. Range Operating conditions Gas temperatures: - 15 _Fuptomax.+160_F(-25 Cuptomax.+70 C) Ambient temperatures: - 15 _Fuptomax.+105_F(-25 Cuptomax.+40 C) for the drive side with motor and - 15 _Fuptomax.+160_F(-25 Cuptomax.+70 C) for the counter side. Type Max. medium temperatures Impeller length Casing Impeller Motor TMR 150/401/N TML 150/401/N - 15 _F to + 160 _F - 25 _C to + 70 _C 15.79 inch (401 mm) TMR 150/601/N TML 150/601/N - 15 _F to + 160 _F - 25 _C to + 70 _C 23.66 inch (601 mm) TMR 150/864/N TML 150/864/N - 15 _F to + 160 _F - 25 _C to + 70 _C 34.01 inch (864 mm) TMR 150/1064/N TML 150/1064/N - 15 _F to + 160 _F - 25 _C to + 70 _C 41.89 inch (1064 mm) TMR 150/1264/N TML 150/1264/N - 15 _F to + 160 _F - 25 _C to + 70 _C 49.76 inch (1264 mm) Tangential fan Type TMR 150 (right hand motor) note: TMR = right hand motor, TML = left hand motor E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 6
LTG Tangential Fan Type TM 150 Specification and design features Tangential fan with close coupled, spray water protected drive motor with terminal box. Rigid bolted, corrosion proof casing of. Side elements of stainless (1.4541). Impeller of. Intake and discharge openings have sealing planes to connect exactly to ducts and appliances. The complete fan is balanced to grade Q 6.3 according to VDI 2060. On the drive side the impeller is bedded via an elastic coupling directly on the motorshaft, on the counterside it is bedded in a ball bearing mounted vibration dampened. Bearing design life is 25000 hours. Dimensions and performance data Dimensions in mm Tolerances acc. to DIN ISO 2768 -cl Type Dimensions A L M D F Air Volume V max Speed n max Power Consumption max Full load Amps. max Masses [cfm] [m 3 /h] [rpm] [hp] [kw] [A] [lb] [kg] TMR 150/401/N TML 150/401/N 27.34 694.5 15.79 401 10.37 263.5 6.38 162 4.72 120 1448 2460 1 0.75 1.86 30.9 14 TMR 150/601/N TML 150/601/N 37.09 942 23.66 601 12.24 311 7.13 181 5.04 128 2296 3900 1.5 1.1 2.65 46.3 21 TMR 150/864/N TML 150/864/N 48.03 1220 34.02 864 12.83 326 7.83 199 5.31 135 3414 50 3 2.2 4.9 7 32 TMR 150/1064/N TML 150/1064/N 55.91 1420 41.89 1064 12.83 326 7.83 199 5.31 135 4356 7400 3 2.2 4.9 77 35 TMR 150/1264/N TML 150/1264/N 63.78 1620 49.76 1264 12.83 326 7.83 199 5.31 135 5239 8900 3 2.2 4.9 83.8 38 E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 7
LTG Tangential Fan Type TMt 150 Gas temperature -15 F to+250 F (- 25 C to + 120 C) The tangential fan Type TMt is a fan for extended temperature range with close coupled motor and enhanced corrosion protection. Operating conditions Gas temperatures: - 15 _Fuptomax.+250_F(-25 C up to max. + 120 C) Ambient temperatures: - 15 _Fuptomax.+105_F(-25 Cuptomax.+40 C) for the drive side with motor and - 15 _Fuptomax.+250_F(-25 C up to max. + 120 C) for the counter side. Range Type Max. medium temperatures Impeller length Casing Impeller Motor TMRt 150/401/N TMLt 150/401/N - 15 _F to + 250 _F - 25 _C to + 120 _C 15.79 inch (401 mm) TMRt 150/601/N TMLt 150/601/N - 15 _F to + 250 _F - 25 _C to + 120 _C 23.66 inch (601 mm) TMRt 150/864/N TMLt 150/864/N - 15 _F to + 250 _F - 25 _C to + 120 _C 34.01 inch (864 mm) TMRt 150/1064/N TMLt 150/1064/N - 25_C to + 120_C - 13_F to + 248_F 41.89 inch (1064 mm) 50 / 60 HZ Tangential fan Type TMRt 150 (right hand motor) note: TMRt = right hand motor, TMLt = left hand motor E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 8
LTG Tangential Fan Type TMt 150 Specification and design features Tangential fan with close coupled, spray water protected drive motor with terminal box. Rigid bolted, corrosion proof casing of. Side elements of stainless (1.4541). Impeller of. On the drive side the impeller is bedded via an elastic coupling directly on the motorshaft, on the counterside it is bedded in a ball bearing mounted vibration dampened. Bearing design life is 25000 hours. Motor und Endlager mit Wärmedämmkappe gegen die Fördermitteltemperatur geschützt Intake and discharge openings have sealing planes to connect exactly to ducts and appliances. The complete fan is balanced to grade Q 6.3 according to VDI 2060. Dimensions and performance data Dimensions in mm Tolerances acc. to DIN ISO 2768 -cl Type Dimensions A L M D F Air Volume V Speed n Power Consumption max Full load Amps. max Masses [cfm] [m 3 /h] [rpm] [hp] [kw] [A] [lb] [kg] TMRt 150/401/N TMLt 150/401/N 30.26 768.5 15.79 401 11.71 297.5 6.38 162 4.72 120 1448 2460 1 0.75 1.86 30.9 14 TMRt 150/601/N TMLt 150/601/N 40 1016 23.66 601 13.58 345 7.13 181 5.04 128 2296 3900 1.5 1.1 2.65 46.3 21 TMRt 150/864/N TMLt 150/864/N 51.57 1310 34.02 864 14.8 376 7.83 199 5.31 135 3414 50 3 2.2 4.9 7 32 TMRt 150/1064/N TMLt 150/1064/N 59.45 1510 41.89 1064 14.8 376 7.83 199 5.31 135 4356 7400 3 2.2 4.9 77.2 35 E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 9
LTG Tangential Fan Type TM 125 / TM 150 / TMt 150 Position of the fan Standard arrangement is horizontal. For vertical mounting the motor is located at the bottom. Installation and start up Fix the fans without any distortion to a plane base frame. For fixation use only the bolt holes provided in the side elements. To connect to ducts and appliances plug in slots and sealing planes are provided over the whole fan width for the intake and discharge openings. Make sure to observe the applicable safety codes before starting the fans. The fans are designed for continous operation with constant load (operation mode S1 according to VDE 0530). For frequent start/stop operation please check with LTG. To keep the ambient temperature below max. at the bearings, it is necessary to insulate the side elements on site. Motor arrangement With the suction opening on top, viewed against the discharge opening, the drive motor is optional either right (TMR) or left (TML) hand side. Electrical equipment The fan is driven by a 4-pole 3-phase motor, 400 V/460 V / 50/60 Hz. Enclosure is according DIN 40050. This gives protection against dust deposits and low-pressure jets from any direction. The motor coil insulation below nominal length 864 is class B, from nominal length up to 1264 it is class F according to VDE 0530. Dimensions in mm d Plug in slots 6 mm deep for duct connection, max. 1.5 mm sheet thickness K slots for self -tapping screws, 4.2 mm, max. 10 mm screw in depth D slots for self -tapping screws, 3.9 (3.5) mm, max. 7.5 mm screw in depth Plug in slots over the full fan width Typical installation of type TMt with on site insulation E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 10
LTG Tangential Fan Type TM 125 Fan curves Test conditions for the fan curves The indicated curves are valid for an air density of ρ = 0.075 lb/cuft (1.2 kg/m 3), a supply voltage of U = 460 V with f = 60 Hz, if operated with a 4 pole motor. The rating tests where done as labortory test according to VDI 2044 with unrestricted inlet and disccharge. Acoustical data The acoustical data are for discharge side, tested in a reverberant field. The A-weighted sound power level can be transformed into a A-weighted sound power level by the equation L pa = -10xlogS/1m 2. For this the exact total applicable panel area S can be used. The sound pressure level in the free field in 1 m distance (full spheric sound radiation) is abt. 11 db less than the sound power level. 1920 1900 0 5 ρ = 0.075 lb/cft 1.2 1.1 1.2 1.1 105 18 0 1.0 1.0 95 1860 1840 0.45 0.40 0.9 0.9 90 85 1820 10 17 pf [ wg] 0.35 0.30 0.25 0.7 0.7 75 70 1760 1740 0.20 0.15 n 0.4 0.3 0.4 0.3 65 60 1720 0.10 0.2 0.2 55 1700 0.05 0.1 0.1 50 16 0.00 0.0 0.0 200 400 600 0 0 1200 1400 1600 Vol. [cfm] 0.1 0.2 0.3 0.4 1 1.2 1.4 1.6 1.8 p d [ wg] 45 Fan curves for 400 mm (15.75 ) nominal length, 4-pole E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 11
LTG Tangential Fan Type TM 125 1920 1900 0 5 ρ = 0.075 lb/cft 2.4 2.2 2.4 2.2 105 18 0 2.0 2.0 95 1860 0.45 1.8 1.8 90 1840 0.40 1.6 1.6 85 1820 10 17 1760 1740 pf [ wg] 0.35 0.30 0.25 0.20 0.15 n 1.4 1.2 1.0 1.4 1.2 1.0 75 70 65 60 1720 0.10 0.4 0.4 55 1700 0.05 0.2 0.2 50 16 0.00 0.0 0.0 250 500 750 0 1250 1500 1750 2000 2250 Vol. [cfm] 0.1 0.2 0.3 0.4 0.7 1 1.3 p d [ wg] 45 Fan curves for 600 mm (23.62 ) nominal length, 4-pole 1940 1920 1900 18 1860 1840 1820 10 17 1760 1740 1720 pf [ wg] ρ = 0.075 lb/cft 0 5 0 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 2.4 2.4 2.2 2.2 2.0 2.0 1.8 1.8 1.6 1.6 0.00 0.0 0.0 400 0 1200 1600 2000 2400 20 3200 Vol. [cfm] 0.1 0.2 0.3 0.4 0.7 1 1.5 p d [ wg] 1.4 1.4 1.2 1.2 1.0 1.0 0.4 0.4 n 0.2 0.2 110 105 95 90 85 75 70 65 60 55 50 Fan curves for 0 mm (31.5 ) nominal length, 4-pole E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 12
LTG Tangential Fan Type TM 125 1950 1930 0 5 ρ = 0.075 lb/cft 3.00 2.75 3.00 2.75 110 105 1910 0 2.50 2.50 1890 1870 1850 1830 1810 pf [ wg] 0.45 0.40 0.35 0.30 0.25 2.25 2.00 1.75 1.50 1.25 2.25 2.00 1.75 1.50 1.25 95 90 85 75 1790 0.20 1.00 1.00 70 1750 0.15 0.10 n 0.75 0 0.75 0 65 60 1730 0.05 0.25 0.25 55 1710 0.00 0.00 0.00 500 0 1500 2000 2500 3000 3500 4000 Vol. [cfm] 0.1 0.2 0.3 0.4 0.7 1 1.5 p d [ wg] 50 Fan curves for 0 (39.37 ) mm nominal length, 4-pole E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 13
LTG Tangential Fan Type TM 125 4200 2.50 ρ = 0.075 lb/cft 10 10 120 4 2.25 9 9 110 4000 2.00 8 8 3900 1.75 7 7 90 30 3700 3600 3500 pf [ wg] 1.50 1.25 1.00 0.75 n 6 5 4 3 6 5 4 3 70 60 50 3400 0 2 2 40 3300 0.25 1 1 30 3200 0.00 0 0 500 0 1500 2000 2500 3000 Vol. [cfm] 0.2 0.4 0.9 1.2 1.5 2 2.5 3 3.5 4 5 6 p d [ wg] 20 Fan curves for 400 mm (15.75 ) nominal length, 2-pole 4200 2.50 ρ = 0.075 lb/cft 20 20 120 4 2.25 18 18 110 4000 2.00 16 16 3900 1.75 14 14 90 30 3700 3600 3500 pf [ wg] 1.50 1.25 1.00 0.75 n 12 10 8 6 12 10 8 6 70 60 50 3400 0 4 4 40 3300 0.25 2 2 30 3200 0.00 0 0 500 0 1500 2000 2500 3000 3500 4000 4500 Vol. [cfm] 0.1 0.2 0.4 1 1.5 2 2.5 3 4 5 6 p d [ wg] 20 Fan curves for 600 mm (23.62 ) nominal length, 2-pole E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 14
LTG Tangential Fan Type TM 150 / TMt 150 Fan curves Test conditions for the fan curves The indicated curves are valid for an air density of ρ = 0.075 lb/cuft (1.2 kg/m 3), a supply voltage of U = 460 V with f = 60 Hz, if operated with a 4 pole motor. The rating tests where done as labortory test according to VDI 2044 with unrestricted inlet and disccharge. Acoustical data The acoustical data are for discharge side, tested in a reverberant field. The A-weighted sound power level can be transformed into a A-weighted sound power level by the equation L pa = -10xlogS/1m 2. For this the exact total applicable panel area S can be used. The sound pressure level in the free field in 3 distance (full spheric sound radiation) is abt. 11 db less than the sound power level. 2000 ρ = 0.075 lb/cuft 4.0 1.40 108 1950 0.7 3.5 1.25 104 1900 3.0 1.10 1850 10 1750 pf [ wg] 0.4 0.3 2.5 2.0 1.5 0.95 0. 5 96 92 88 1700 1650 0.2 0.1 rpm 1.0 0 0.35 84 1600 0.0 0.0 0.20 0 1250 1500 1750 2000 Vol. [cfm] 0.4 1.0 1.2 1.4 1.6 1.8 p d [ wg] 76 Fan curves for 401 mm (15.79 ) nominal length, 60 Hz E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 15
LTG Tangential Fan Type TM 150 / TMt 150 2000 ρ = 0.075 lb/cuft p sf 5.0 1. 108 1950 0.7 4.5 1.65 104 1900 4.0 1.50 1850 10 1750 pf [ wg] 0.4 0.3 3.5 3.0 2.6 1.35 1.20 1.05 96 92 88 1700 1650 0.2 0.1 rpm 2.0 1.5 0.90 0.75 84 1600 0.0 1200 1450 1700 1950 2200 2450 2700 1.0 0 Vol. [cfm] 76 0.7 0.9 1.1 1.3 1.5 p d [ wg] Fan curves for 601 mm (23.66 ) nominal length, 60 Hz 2000 ρ = 0.075 lb/cuft 5.5 2.4 108 1950 0.7 5.0 2.2 104 1900 4.5 2.0 1850 10 1750 pf [ wg] 0.4 0.3 4.0 3.5 3.0 1.8 1.6 1.4 96 92 88 1700 1650 0.2 0.1 rpm 2.5 2.0 1.2 1.0 84 1600 0.0 1.5 2000 2250 2500 2750 3000 3250 3500 3750 4000 Vol. [cfm] 76 0.7 0.9 1.1 1.3 1.5 p d [ wg] Fan curves for 864 mm (34.02 ) nominal length, 60 Hz E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 16
LTG Tangential Fan Type TM 150 / TMt 150 2000 ρ = 0.075 lb/cuft 6.0 2.75 108 1950 0.7 5.5 2.50 104 1900 5.0 2.25 1850 10 1750 pf [ wg] 0.4 0.3 4.5 4.0 3.5 2.00 1.75 1.50 96 92 88 1700 0.2 rpm 3.0 1.25 84 1650 0.1 2.5 1.00 1600 0.0 2250 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 0 0.75 1.00 1.25 1.50 2.0 0.75 Vol. [cfm] p d [ wg] 76 Fan curves for 1064 mm (41.89 ) nominal length, 60 Hz 2000 1950 0.7 ρ = 0.075 lb/cuft 10 9 4.5 4.0 108 104 1900 8 3.5 1850 10 1750 pf [ wg] 0.4 0.3 7 6 5 3.0 2.5 2.0 96 92 88 1700 0.2 rpm 4 1.5 84 1650 0.1 3 1.0 1600 0.0 2 2500 3000 3500 4000 4500 5000 5500 6000 Vol. [cfm] 76 0 0.75 1.00 1.25 1.50 p d [ wg] Fan curves for 1264 mm (49.76 ) nominal length, 60 Hz (only type TM 150) E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 17
LTG Tangential fan Type TM 125 / TM 150 / TMt 150 Selection Application Example Your data Designations gas cold air V [cfm] air volume gas temperature t [_F] 14 ambient temperature drive side t [_F] counter side t [_F] condensation located at drive side arrangement 23 23 yes ventilation for refrigerated rooms right hand side vertical Drive motor power supply 3 -phase voltage U [V] 460 frequency f [Hz] 60 Specified performance air volume* V [cfm] 3250 static pressure* Δp f [ wg] *at specific gravity ρ [lb/cuft] 0.075 aktive impeller length min. L [ ] max. L [ ] 30 44 total length A [ ] 59 Procedure 1. conditions of application fan type 2. air volume V [cfm] achieveable with length 3. static pressure Δp f [ wg] achieveable with length cold air 14 _F TM 3250 864, 1064, 1264 1064, 1264 4. drive side right hand Δp f [ wg] static pressure p d [ wg] dynamic pressure at the discharge area c [fpm] velocity at the discharge area ρ [lb/cuft] specific gravity p d = ρ/2sc 2 = /U n [rpm] speed U [V] voltage f [Hz] frequency [A] full load amps [hp] power consumption [db(a)] A -weighted sound power level L pa [db(a)] A -weighted sound power level S [sqft] panel area Selected LTG -Tangential fan type TMR 150/1064/N Performance data air volume V [cfm] 3250 static pressure Δp f [ wg] 3 dynamic pressure p d [ wg] 3 exhaust velocity c [fpm] 3378 speed n [rpm] 1740 Electrical data power input [hp] 1.63 full load amps [A] 3.76 Acoustical data sound power level A -weighted [db(a)] 92.1 sound pressure level in the free field in 1 m distance (full spheric sound radiation) L pa [db(a)] 81.1 E PO Box 2889 Spartanburg, SC 29304/USA 864/599-6340 Fax 864/599-6344 TM-USA -TP (05/09) e -mail: info@ltg -Inc.net Internet: www.ltg -Inc.net Former editions are invalid. Subject to technical modifications. 18