Volumetric Measuring Devices Issued: Revision Number: 2

Similar documents
Types and 52.20, Specialized test procedure Milk receiving and milk pick-up metering systems

HE Stewart Vacuum Gasoline System employs a small tank, installed under the hood. This tank is connected by brass tubing to the intake manifold, also

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

LEAK TEST PROCEDURE MRT4-DC LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

LEAK TEST PROCEDURE DC CHANNEL LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

Model VR4 Vacuum Regulator

Low Pressure Transfer Systems

Honda Accord/Prelude

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

Operating and Installation Instructions

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN #

Model DF233 Control Valve

INSTRUCTION MANUAL AC2516 REVISION D INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Series 1580 In-Line Mounted Centrifugal Fire Pumps

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

CUSTOM COMBINATION AIR VALVE

Type 644 and 645 Differential Pressure Pump Governors

P239-1 Supply Pumper Instructions

The Discussion of this exercise covers the following points:

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

O2 Sensor Testing. If your engine has unexpectedly started to run poorly, an O2 Sensor Test should be performed.

Symptom Corrective Action. Wrong polarity of cell, block, row of battery. Interruption at connector. Interruption due to empty cell.

Name Date. True-False. Multiple Choice

TYPE PC Propeller Condensate Pumps

A pump is a machine used to move liquid through a piping system and to raise the pressure of the liquid.

Valves. External Valves, Gages and Fittings. Bulletin No What options are available when stainless steel is not suitable for external parts.

Chapter 2. The Vehicle-Tank Metering System

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

Geo-Prime Tank. Table of Contents. Installation, Operation & Maintenance Instructions AFCG1PT Revision: 7/3/14. Replacing a Pump 12

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679.

Congratulations PRE-OPERATION SETUP

Planned Maintenance & Adjustment Procedures

Model DF269 Control Valve

SHAFT ALIGNMENT FORWARD

Baumann Series Flexsleev Control Valve Instructions

Marine Fuel Filtration. Marine Turbine Series. Stage One: Separation. Stage Two: Coalescing. Stage Three: Filtration. And more

TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X

Photoillustration: Harold A. Perry; images: Thinkstock & Ford

This instruction is valid for all ACE pump models shown on page 2

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

3M TM Filter Housing 1BS-T/1BS-TW Series

INSTRUCTION SHEET FOR TP PRO-SERIES CLASSIC PUMP

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

6.0L HARD START / LONG CRANK / NO START TSB LOW INJECTOR CONTROL PRESSURE (ICP)

Marine Turbine Series

PREVOST AIR SYSTEMS WHAT THEY DO AND HOW THEY DO IT

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system:

Engine Emission Control 6.7L Diesel

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Turbocharger system. Note: Observe rules of cleanliness Page Charge air pressure control connection diagram Page 21-2.

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

SMT Place Manncorp 1610 Republic Road Huntingdon Valley, PA PIK-MANN ( )

Fuel System Diagnosis

NECO Pumping Systems

Reliable Temperature Compensation is Critical to CNG Vehicle Safety

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Vacuum Bleeder Kit. Product:

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Turbo Boost Pressure Test

Geo-Prime Tank U.S. Patent Number 8,544,282

M39075 ( IF- 1) Integra- Fuse Rivet Tool

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Installation & Service Instructions

HIGH FUEL PRESSURE LINE

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Alarms and Fault Finding

Instant Chat off the main page of Or simply call our tech team at

Evaluation of a Gearbox s High-Temperature Trip

Inspection and Maintenance of Flame Arresters

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Pilot phase - Learnings

Components of Hydronic Systems

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

2009 Mercedes-Benz E ENGINE Fuel System - E63 ( ) GENERAL NOTES: PASSENGER CARS: FUEL SYSTEM - AH47.00-Z-9999AZ

BLACKMER BYPASS VALVES

Owner s and Maintenance Manual for: Lincoln QuickLub Systems

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

Prodigy HDLV System Troubleshooting - Generation III

Pumps and Maintenance

SERIES PC INSTRUCTION AND OPERATION MANUAL

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

Tuning A Walbro Carb. Walbro Carb TUNE UP & Illustrated Guide

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Fisher RSS Lined Globe Valve

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Pump Operating and Maintenance Manual - Models

The Discussion of this exercise covers the following points: Centrifugal pumps in series Centrifugal pumps in parallel. Centrifugal pumps in series

UNDERGROUND STORAGE TANK INSPECTION CHECKLIST

Gauges, Sight Glasses and Vacuum Breakers

Installation, operation and maintenance manual

MP18 Stacking Valve System Technical Information Manual

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

Fisher RSS Lined Globe Valve

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

MODIFICATIONS AVAILABLE - MADE TO ORDER - CONSULT OUR FACTORY. (MINIMUM ORDER MAY BE REQUIRED.)

Transcription:

Field Inspection Manual Part: 4-STP Section: 29 Page: 1 of 5 APPLICATION This procedure is used when performing accuracy tests on any measuring systems that incorporate an air eliminator or deaerator of the type that is designed to be installed upstream of the pump. Examples of such measuring systems may be encountered in chemical operations measuring products such as: concrete additives or liquid fertilizers, etc.; and in the milk industry where they are commonly referred to as a Type E Systems or Vacuum Air Elimination Systems designed for receiving and pick-up applications. PURPOSE Vacuum tests are performed on a system to establish if air enters into the system. The inability to hold a vacuum under test conditions indicates a leak in the system which may draw in (and probably entrain) air and may cause significant measurement errors. LEGISLATIVE REFERENCES Not applicable. Refer to installation requirements as per manufacturer s instructions and/or the applicable Notice of Approval. PROCEDURE Note: A valid inspection cannot be carried out if a vacuum leak exists on the vacuum side of a receiving or pick up metering system. Ensure that an operating vacuum gauge is installed on the suction side of the system.

Field Inspection Manual Part: 4-STP Section: 29 Page: 2 of 5 Open the valve on the feed tank. Let the liquid fill the suction line and deaerator. To fill the system, turn it on and start liquid flowing through it normally. Ensure that the deaerator vent does not leak during the test. The float operated valve may not maintain a vacuum. Check valves are present in some vents, whereas others have a threaded fitting which must be turned shut. Shut the pump off. Close the feed tank valves. Start the pump. When product flow stops and vacuum reaches its peak, turn off the pump. Watch the vacuum gauge. The vacuum indicated should maintain its peak value to within ± 3.4 kpa (0.5 psi) for at least two minutes. If vacuum holds, carefully open the feed tank valves to release vacuum and proceed with the normal tests. If the vacuum does not hold, investigate the cause(s). The system must be fixed before proceeding with the normal tests.

Field Inspection Manual Part: 4-STP Section: 29 Page: 3 of 5 EFFECT OF VACUUM LEAKS Almost all of the air which leaks into the suction side of a metering system will become entrained in the liquid. Once entrained, air can be very difficult to remove and will most likely result in being measured as product. Large slugs of air are more easily removed by the deaerator. There are many locations where air can leak into the system, some more serious than others. Air leaking into the upper dry area of a vacuum deaerator, above the inlet, will probably not become entrained in the liquid and will only cause periodic stoppage of the pump whenever the liquid level in the deaerator becomes low enough to activate the float switch. Vacuum will also be lost if the check valve at the pump outlet, or the compartment valve to a full compartment leaks liquid. Neither of these leaks will allow air in and, consequently, will not influence measurement. Once the system is inspected and reassembled, check for reverse flow after a truck is unloaded. Typically, this type of measuring system has two check valves. It is quite unlikely both would leak enough to effect measurement between tests (the meter registers usually cannot be reversed).

Field Inspection Manual Part: 4-STP Section: 29 Page: 4 of 5 Areas where vacuum leaks will definitely result in air entrainment are hose wall leaks, loose hose fittings, faulty fitting gaskets, valve stem packing, truck pump leaks (drive shaft seal, housing gasket), pipe and pipe fittings. The most critical area in which vacuum leaks can occur in these type of systems is after the deaerator, more precisely, the fittings between the pump and the deaerator, and the pump seal. Any air entering these areas cannot be removed and will definitely affect measurement. DETECTION AND CORRECTION OF VACUUM LEAKS Most leaks can be stopped by simply tightening threaded connections, hose clamps, the deaerator cover seal, the deaerator vent, or valve packing, etc. With the pump turned off, gravity head will sometimes cause liquid to drip from the more obvious leaks. Some leaks will only show up under vacuum and can be located through the process of elimination by sequentially isolating all of the potential problem areas. Install a blanking plate or valve starting at the truck and working back: truck pump, receiving hose, deaerator inlet, pump (a vacuum gauge must be installed and enough pipe retained to keep the pump primed). Leakage stopped by closing the meter control valve indicates a check valve leak.

Field Inspection Manual Part: 4-STP Section: 29 Page: 5 of 5 MEASUREMENT CANADA S POSITION ON VACUUM TESTING Measurement Canada s responsibility is to perform a vacuum test. It is the responsibility of the device owner to locate and repair leaks before a valid inspection can be performed. However, expertise is not always available at the plant and instead of cancelling a scheduled inspection, which requires time and travel expenses, it might be to the inspector s advantage to do a quick check with the owner's assistance. The problem may be quickly identified and rectified. REVISION 1 Revised various sections to be applicable for any measuring system that incorporates an air eliminator or deaerator of the type that is designed to be installed before (upstream of) the pump. REVISION 2 Digital gauges versus bourdon tube gauges are capable of detecting very small changes in vacuum and therefore, providing a range for the gauge reading was necessary. The procedure was revised to add the statement allowing for a range in the peak vacuum, i.e., ± 3.4 kpa (0.5 psi).