Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Similar documents
STONESTAR AUSTRALIA PTY LTD

7 MODES OF OPERATION INVERTER STATUS Standby: The PV string can only provide just enough voltage to minimum requirements of the controller.

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

User Manual. Solar Charge Controller 3KW

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

CPS Energy Balancer. Version: 1.0

PVES Series User Manual User Manual Shenzhen Pvinergy Technologies Co., Ltd

Solar Charge Controller

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

User Manual Solar Charge Controller 3KW

Off Grid Solar Inverter. LVS 50M User Manual

CPS SCA Series Grid-Tied PV-Inverter CPS SCA3/4/5KTL-O/US. Installation and Operation Manual

AeroVironment Universal Solar Pump Controllers

8 Troubleshooting and Maintenance

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

Manual. EN Appendix. VE.Bus BMS

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

Phoenix Inverter

SC SERIES SOLAR CONTROLLER USER MANUAL Ver 1.0

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

Owner s Manual. Contents GP-PWM-10-SQ

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

c-go 24V/6A 24V/8A 24V/12A

UGE-4K Off-Grid Controller OWNER S MANUAL

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

String Inverter (SUN KTL-A)

HOYMILES MICRO-IVERTER MI-250

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

User Manual Rittal PMC UPS 6kVA

S150,S300 Series Pure Sine Wave Inverter User s Manual

User s Manual. Automatic Switch-Mode Battery Charger

User Manual 1.5KVA-3KVA INVERTER / CHARGER

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER MANUAL ONLINE UPS

User Manual. 3kW Hybrid PV Inverter HX-3000

H I G H E f f i c i e n c y G r i d F e e d I n v e r t e r

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

YSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system

Pure sine wave charger inverter Product Manual

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

MICRO-INVERTER OMNIKSOL M-300

SolarMax P series The power package for residential solar plants

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Solar Hybrid Inverter SP Brilliant Series

OASIS-UM-01. User Manual. Inverter/Charger Oasis 6000 Rev 1.0. Oasis 6000 Series MAY 2012 ISSUE 01

User Manual. 6K/10K Online UPS. Uninterruptible Power Supply System

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

Installation and Operating Instructions. Solar System Controller ISC3020

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

1. Introduction OHY1P kW Hybrid Inverter USER MANUAL V2.0

DC TO AC POWER INVERTER

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

3000W HF/PFC Battery Charger

CX-SERIES ADVANCED BATTERY CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER

USER MANUAL MODEL: 3SPC3.3/106-D72/1100

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

CP /240-MC4 User Manual

New Central Grid-tied PV Inverters. 500kW/1MW 3-level T-type modular inverters 1MW/2MW PV power containers

9.1.4 Troubleshooting of Faults in LCD Screen

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

User Manual. SP10000 Premium

User Manual. 6K/10K Online UPS with Isolation Transformer. Uninterruptible Power Supply System

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

EPS/ELA-Series User Manual EPS/ELA 250W

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

Solar Hybrid Inverter SP Efecto Series

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

ABB central inverters ULTRA-750/1100/ kW to 1560kW

Manual. Lynx Ion 24V/180Ah Lithium Ion Batteries

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

1. Important Safety Warning

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

Mass Sine 24/10000 Mass Sine 24/15000

GSM Series MPPT PV Controller. Version 1.0. Manual

All-in-one Storage Hybrid System

SolarMax MT series The all-rounder for trade and industry

User Manual. Hybrid PV Inverter. Version: 2.1

User Manual. EGL - 6K/10K Online UPS. Uninterruptible Power Supply System

USER S MANUAL SOLAR POWER INVERTER KW-6KW

User Manual V1.0 MaxiFlex 3000

Transcription:

Manual EN BlueSolar Grid Inverter 1500 / 230 2000 / 230 2800 / 230 4000 / 230 5000 / 230

Before you start This manual contains important information regarding installation and safe operation of this unit. Please read this manual carefully before use. The BlueSolar grid-tied solar inverters are professional products that need to be installed by qualified personnel only. Please read the safety instructions for more information. Inside the inverter very high voltages are present which are dangerous for life. If you encounter any problems during installation or operation of this unit, first check this manual before contacting your local dealer or a Victron energy representative. Instructions inside this manual will help you solve most installation and operation difficulties. 1. Content BlueSolar 1500, 2000 and 2800 overview Front View Bottom View LCD Display Showing the inverters status Operation LED Solar panel input RS232 Utility (AC) Connector

BlueSolar 4000 and 5000 overview Front View Bottom View Operation LED LCD Display Showing the inverters status RS232 Utility (AC) connector Opening the package After opening the package, please check the contents of the box. It should contain the following items: Item Name Quantity 1 BlueSolar inverter 1 2 Mounting frame 1 3 Mounting screws 4 4 Safety-lock screws 2 5 AC socket assembly 1 6 Instruction manual 1

2. INSTALLATION 2.1 Safety instructions The solar panels and cables should have Protection Class-II Do not disconnect the DC-cables when the inverter is connected to the utility mains! DC arcs will damage the connectors and could lead to serious burns and risk of fire. Qualified personnel must install the inverter. This inverter should be connected to a separate fuse in the breaker-box. No other household devices should be connected to this. Do not open the inverter! High voltages inside the inverter are dangerous for life. Even after the unit is disconnected from the grid and photovoltaic panels, high voltages may still exist inside the PV-inverter. Some parts and surfaces of the Inverter can become hot during operation. To reduce the risk of injury, do not touch the heat sink at the back of the PV-Inverter or nearby surfaces while Inverter is operating. Do not install the inverter near explosive vapors or flammable items. This unit is designed for outdoor usage(ip65. Do not expose the inverter to direct sunlight. Direct sunlight increases the internal temperature which may reduce conversion efficiency. Do not expose the inverter to rain. Direct exposure to rain may, in course of time, increase humidity in the product, and ultimately result in failure.

2.2 Mounting instructions A. Select a wall or solid vertical surface that can support the inverter. B. The inverter uses natural convection for cooling. Allow at least 20cm space above, below and on the sides of the inverter. C. Using the mounting frame as a template, drill 4 holes as illustrated in the following figures. D. Fix the mounting frame to the wall with the 4 screws. E. Hang the inverter on the mounting frame. F. Insert the safety-lock screws to the bottom leg to secure the inverter.

G. Check the mounting of the inverter securely by trying to raise it from the bottom. The inverter should remain firmly attached. When the mounting is done, the inverter can be connected. 2.3 Connecting the inverter to the public grid A. Install a separate AC-line on a dedicated breaker from the breaker-box to the solar-inverter. No other appliances should be connected to this line! Open the breaker or fuse to disconnect power from the line. B. Connect a mains-cable to the AC-plug as described below: male insert with coupling ring shell Pressing screw cap AC wire Insert ac-wire through the pressing screw-cap and the shell. Connect wires according to polarities indicated on terminal block. L LINE (brown or black), N Neutral (blue) and G system ground (yellow-green). Fasten the gland plate with attached screws. Twist the gland so that the cable is firmly fixed. Insert Line wire to Pin L, Neutral wire to Pin N and Ground wire to Pin G. Pin G Pin N Pin L

Recommended wire size for AC wire Model Minimum wire size (mm 2 ) BueSolar 1500 1.50 BueSolar 2000 2.50 BueSolar 2800 2.50 BueSolar 4000 4.00 BueSolar 5000 4.00 C. Connect the mains-cable to the inverter. D. Connect the mains-cable to the dedicated power outlet. Do not close the circuit breaker or fuse while working on the inverter. 2.4 Connecting the inverter to the photovoltaic panels A. The connectors from the photovoltaic panels should be MC4 (Multi-Contact 4mm When more than one PV-string is connected to the inverter (for the 2800, 4000 and 5000W) models, make sure the strings are identical. The total open circuit voltage and short circuit current must be equal. Connecting these plugs to the solar-cables requires special tooling, and should only be done by qualified personnel. Improper connection can cause fire. Most solar panels have these connectors already attached to the cables. B. The voltage from the photovoltaic panels should never exceed the maximum input voltage of the inverter. Blue Solar 1500: The open circuit voltage of the solar array (Voc) should never exceed 450V under any condition! Blue Solar 2000 and 2800: Voc should never exceed 500V under any condition! Blue Solar 4000 and 5000: Voc should never exceed 550V under any condition! The inverter will be permanently damaged if the Voc is too high. Notice that the Voc is at its highest when the solar-panels are at the lowest local temperature that can be xpected, and do not carry current (inverter unplugged from public grid), with maximum sunlight (1000W/m2).

C. Verify if the polarity of the DC-plugs is correct. Incorrect polarity connection could permanently damage the unit. D. Connect the positive and negative terminals from the PV panel to positive (+) terminals and negative (-) terminals on the inverter. The maximum current rating of DC terminals is 20A. Verify that the short-circuit-current of the solar array is below the maximum DC input current of the inverter. The inverter will not draw more current form the panels than I PV max (see specification). If more current is available from the panels, the inverter will not consume this extra current / power. The total system power will be lower then expected. 2.5 System start-up When the PV panels are connected and their output voltage is greater than 100 VDC but the AC grid is not yet connected, the message on the LCD display produces the following messages: MODEL= XkW -> Waiting -> Disconnect grid. The display repeats Disconnect grid and the red LED Fault turns on. Close the AC breaker or fuse between PV-Inverter and grid. If the mains-voltage and frequency are within limits, a countdown will start (visible on the display). When the countdown has reached 0s, the inverter will connect to the grid and deliver energy. The LCD displays Pac=xxxx.xW, which is the power fed into the grid. The green LED will be on indicating a normal condition. 2.6 System Diagram Inverter connected to separate circuit breaker

3. MODES OF OPERATION There are 5 different modes of operation. Standby mode If the voltage from the photovoltaic panels is <100VDC the inverter has just enough power to start-up the internal controller, but the voltage is too low to start energy conversion. Waiting mode When the voltage from the photovoltaic panels is >100VDC, the inverter enters a waiting-state and attempts to connect to the grid. Normal mode In this mode the inverter works normally. Whenever the voltage from PV panel is sufficient (voltage>150vdc), the inverter converts power into the grid. In normal mode the green LED is on. Fault mode The internal controller continuously monitor the system status. In case of unexpected conditions such as grid problems or an internal failure, it will display the information on its LCD-display and light up the red Fault LED. Shutdown mode During periods of little or no sunlight, the inverter automatically stops. The display and LED s on the front panel do not work. Starting-up display sequence: Once the PV power is sufficient, the inverter displays information as follows: User: xxxx Spec:xxxx Model:x.xkW SW Version :xx.xx Checking xxs Normal State Pac= xxx.x W. The LCD display backlight automatically turns off after 30 seconds to save power. LCD display The first line of LCD State Display content Remark Waiting Initial waiting Wait State Checking xxs System checking Reconnect in xxs System checking Standby PV voltage low Normal State Pac = xxxx.x W Inverter output power Auto Test State Auto testing Protection auto test Fault State System xx Fault System fault Permanent State Inverter xx Damaged Inverter fault Program State Programing Update software The second line of LCD Cycle display Display time /s Remark User: xxxx 1 The user type Spec: xxxx 1 The inverter spec type Model:x.xkW 1 The inverter model SW Version:xx.xx 1 The software version Etotal: xxxkwh 2 The energy total Etoday: xx.xkwh 2 The energy today Ttoday:xxhxxmin 2 Operation hours today PV:xxxV BUS:xxxV 2 The PV and Bus voltage AC:xxxV xx.xhz 2 The Grid voltage and frequency

4. TROUBLE SHOOTING In case of a malfunction/system failure, the red (Fault) LED on the front panel turns on and the LCD displays the cause of the problem. Please refer to the following table for a list of all possible LCD-warnings. Grid V Fault The utility mains voltage is too high or too low Check the mains-voltage on the display. Wait for 5 minutes. If the grid voltage returns to normal the inverter will automatically restart. If the voltage increases and becomes too high when the inverter is starting up, it possibly means that the mains-connection has too much resistance, or has bad connections. It is possible to monitor the mains-voltage with the data-logging software supplied with your inverter. A mains-voltage that increases with more then 10V when the inverter goes from 0W to full output power indicates a high impedant mains network. If the problem persists, call an electrician. Grid F Fault The utility mains frequency is too high or too low Check the mains-frequency on the display. Wait for 5 minutes. If the grid frequency returns to normal the inverter will automatically restart. If the mains-frequency remains outside the limits of this inverter, call an electrician. Disconnected grid There is no mains-voltage present on the inverter. Check if the fuse or circuit -breaker for the solar-inverter in the circuit breaker-box is closed. If the circuit breaker or fuse is closed call service. High PV Voltage The voltage coming from the solar-panels is too high. Check the value on the LCD which refers to the PV-voltage, (PV:xxxV). If this value is close to or more then the value in the specification referred to as Max input voltage, open the circuit-breaker and then remove all cables from the PV-inverter immediately! Call service. Your PV-inverter will be damaged if no action is taken. High Temperature The temperature of the inverter is too high. Check if the ambient temperature of the inverter is not too high. Check if the inverter is mounted according to the specification, and that there is sufficient room around the inverter for convection. Check if the black cooling bracket behind the inverter is clean and has no obstructions. If the problem persists, call service. Not Consistent The 2 micro controllers in the inverter have contradicting data. Call service. Eeprom damaged The Eeprom memory in the inverter is damaged. Call service. Low Isolation During start-up of the inverter, the inverter measures the electrical isolation between the solar-panels to protective earth / ground. If the isolation is insufficient, the inverter will not start up to prevent an unsafe situation. Open the circuit breaker, and then disconnect the DC-plugs from the inverter for 5 minutes. After 5 minutes reconnect DC-plugs and close AC breaker.

High ground I The GFCI (Ground Fault Current Interrupter) is active due to a fault current from live parts to the earth. The inverter will shut down. Open the circuit breaker, and then disconnect the DC-plugs from the inverter for 5 minutes. After 5 minutes reconnect DC-plugs and close AC breaker. If the problem persists, call service. Please Initiate The inverter has not been initiated for the first time in the factory. Call service GFCI Damaged The GFCI-protection unit is damaged. Call service Sensor Damaged The DC current sensor in the inverter is damaged. Call service SCI damaged The communication between the two micro controllers in the inverter has failed. Call service High DC INJ Normally the inverter injects AC-current into the public grid. When the warning high DC INJ is on, for some reason the injection of DC-current into the grid is higher then acceptable, and the inverter shuts down. Open the circuit breaker, and then disconnect the DC-plugs from the inverter for 5 minutes. After 5 minutes reconnect DC-plugs and close AC breaker. If the problem persists, call service. High Bus Voltage The internal BUS-voltage is too high. Open the circuit breaker, and then disconnect the DC-plugs from the inverter for 5 minutes. After 5 minutes reconnect only the DC-plugs (do not close the circuit-breaker!). Is the warning High Bus Voltage visible on the display? Yes the voltage from the solar panels is too high, or there is an internal failure (Call service). No close the circuit-breaker and wait for the inverter to reconnect to the grid. If the High Bus Voltage -warning comes back again after reconnecting to the grid, there is probably something wrong with the grid. (Call an electrician). Relay Damaged The internal relays used for connecting the inverter to the grid are damaged. Open the circuit breaker. Call service Auto test failed The self-test of the inverter has failed. There is an internal failure. Open the circuit breaker, and then disconnect the DC-plugs from the inverter for 5 minutes. After 5 minutes reconnect DC-plugs and close AC breaker. If the problem persists, call service. 2.5V Ref Fault The internal voltage reference of the inverter is defect. Call service. There is nothing visible on the display. The display power is coming from the solar panels. Check if the DC-plugs are firmly connected to the inverter. If there is sufficient daylight and the LCD does not give any indication / value call service.

5. SPECIFICATIONS BluePower Grid Inverter 1500 2000 2800 4000 5000 GRID OUTPUT (AC) Nominal output power 1500W 2000W 2800W 4000W 5000W Maximum output power 1650W 2200W 3000W 4400W 5500W Nominal output current 6.52A 8.7A 12A 17.5A 22A Maximum output current 7.2A 9.5A 13A 19A 24A Maximum fuse protection 16A 16A 16A 25A 25A Harmonic distortion of output current <3% at nominal power <5% at 50% power Nominal AC output voltage 220V - 230V - 240V Power factor >0,99% at nominal power Operating AC voltage range 190-260V Nominal AC frequency 50Hz Operating AC frequency range 45.5-54.5Hz Internal consumption at night <0,1W Short circuit proof Yes SOLAR INPUT (DC) Maximum Input voltage 450V 500V 500V 550V 550V Input Voltage MPPT range 110-430V 110-480V 110-480V 110-530V 110-530V Maximum input current 9A 10A 13A 18A 20A Maximum input power 1750W 2280W 3160W 4500W 5200W Number of MPPT trackers 1 1 1 1 1 Number of strings 1 1 2 4 4 Start-up power 7W 7W 7W 10W 10W Ground fault monitoring RCMU (residual current monitoring unit) Reverse polarity protection Yes, with short circuit diode EFFICIENCY Maximum efficiency 95.5% 96.4% 96.4% 97.6% 97.8% European standard efficiency 94.5% 95.4% 95.5% 96.7% 96.9% GENERAL Topology Transformerless Communication port RS232 Operating temperature range -20 C to 60 C (automatic power limit in case of internal over temperature) Nominal power temperature range -20 C to 55 C Storage temperature range -20 C to 70 C Maximum operating altitude 2000 m (5% derating at 4000 m) Cooling method Natural convection Relative humidity Max 95% ENCLOSURE Protection degree IP54 DC connectors MC4 (Multi Contact 4mm) Weight (kg) 14.8 kg 14.8 kg 14.8 kg 20.7 kg 20.7 kg Dimensions (hxwxd, mm)) 376x415x125 376x415x125 376x415x125 368x475x195 368x475x195 STANDARDS Safety EN 50178 EMC, Emission EN 61000-6-3 EMC, Immunity EN 61000-6-2 EMC, Harmonics and Flicker EN 61000-3-2, EN 61000-3-3 Automatic Grid Disconnection VDE 0126-1-1 (2006)

Victron Energy Blue Power Distributor: Serial number: Version : 00 Date : 14 February 2011 Victron Energy B.V. De Paal 35 1351 JG Almere PO Box 50016 1305 AA Almere The Netherlands General phone : +31 (0)36 535 97 00 Customer support desk : +31 (0)36 535 97 03 Fax : +31 (0)36 535 97 40 E-mail : sales@victronenergy.com www.victronenergy.com