abc INSTALLATION, OPERATION, & MAINTENANCE MANUAL ADDENDA 210 MKII LOW TEMPERATURE CELL SAMPLER

Similar documents
abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR SERIES 210 HI-TEMP SAMPLER 4 150LB BITUMEN SAMPLER

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR SERIES 210 MK.II SAMPLE PROBE

Installation and Maintenance Instructions for Grinnell GRP Pneumatic Rack and Pinion Actuators

Systems. In-line Blending. Solutions you can trust

A Member of the. Integrated Metering Technologies

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTRUMENT ISOLATION VALVE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP

Installation and Maintenance Instructions for Morin MRP Pneumatic Rack and Pinion Actuators

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP

High Pressure Bypass System Type SOV acc. to TRD 421

A Member of the. Integrated Metering Technologies

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

OCTOPUS 45mm Bore Linear Actuator Sailboat Drive Style LAR

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INLOOP CRUDE OIL SAMPLER

Clif Mock. CD20 (12VDC) Sampler Drive. User Manual. Manual No A

introduction FE Series Butterfly Valves Product Data Sheet

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE

APT14 Automatic Pump Trap Installation and Maintenance Instructions

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

SEries 41 check valve installation, operation & maintenance manual

introduction FK Series Butterfly Valves Product Data Sheet

80V 300Ah Lithium-ion Battery Pack Data Sheet

Installation and operating manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER FIXED INSERTION

KAM E-IAS ELECTRIC ISOKINETIC AUTOMATIC SAMPLER

Introduction. Globe and Angle Body Control Valves. In Line Valve provides Solutions to Flow Control

14 and Larger Wafer and Lug Style Dual Disc Check Valve. Operation, Maintenance and Installation Manual

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

JISKOOT Bunker Blending

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

TRUNNION MOUNTED METAL SEATED BALL VALVES

Installation, Operation, and Maintenance Manual

T1/T2 HYDRAULIC RAM INSTALLATION & SERVICE HANDBOOK

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Lease Automatic Custody Transfer

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions

STYLE B THERMOSTATIC TEMPERATURE REGULATOR

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

Installation and Operating Guidelines Battery Back-up Pump System

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

OPERATING SERVICE MAINTENANCE MANUAL

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd

Rectangular Door L-VAT with pneumatic actuator double acting

HIGH PERFORMANCE BUTTERFLY VALVE MODEL HP300 SERIES

Installation and user s guide H A. TP20 probe for FARO arm

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

GLOBE 3 WAY CONTROL VALVE SERIES INTRODUCTION

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA

Automatic Sampling/Quality Measurement Crude Oil. Crude Oil Quality Association San Antonio, TX March 7, 2013

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Operating Instructions

Easytork Vane Actuator IOM

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Manual No: Revision: F. Mag Probe Assembly Manual

Eim Controls THE G SERIES GAS ACTUATOR. Re-designed for another half century of service to the pipeline industry.

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

16000SIII Automatic Grease System

Installation, Operation, and Maintenance Manual

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Contents. 1. Preface Change record Fuse Replacement...5. MPU fuses...5

Installation & Technical Guide. Domestic & Commercial.

PART XV Metering Systems SECTION 2 GUIDE TO GAS METERING SYSTEMS

Data Sheet BP v 100Ah LiFePO 4 (Peli TM Case Kit)

These installation and maintenance instructions must be read in full and completely understood before the installation!

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

COSASCO HYDRAULIC ACCESS FITTING User Manual

TITAN FLOW CONTROL, INC.

TKD Series 3-Way Ball Valves Product Data Sheet

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Installation, Operation & Maintenance Manual

Installation, Operation, and Maintenance Manual

Patient Care Facility

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

SUPER PUMP OUT SYSTEM

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

DK Series Pneumatic Diaphragm Valves Product Data Sheet

WIRELESS STEERING INSTALLATION MANUAL

Katharometer Power Supply Units

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

SELF PRIMING CHEMICAL SERVICE PUMPS

introduction TKD Series 3-Way Automated Ball Valves Product Data Sheet

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

STORM Guardian. Operator s Handbook

Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance...

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

Operation Notes and Alignment Instructions

Transcription:

abc INSTALLATION, OPERATION, & MAINTENANCE MANUAL ADDENDA 20 MKII LOW TEMPERATURE CELL SAMPLER This Jiskoot Product is designed to provide outstanding service if correctly installed, used and maintained recognising the effects of the process conditions (temperature, pressure, wax/pour point, sediment, etc.). Truly representative sampling of crude oils etc., cannot be achieved by one single product in isolation. A well designed system and operating procedures as laid down in the Sampling Standards ISO 37, API 8.2 and IP Chapter VI section 2 are mandatory. Please consult Jiskoot for further information and assistance. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Jiskoot Autocontrol Ltd. 200 Jiskoot Autocontrol Ltd. All rights reserved.

20 MkII Low Temperature Cell Sampler TABLE OF CONTENTS INTRODUCTION... 2 2 OPERATING INSTRUCTIONS... 2 3 GENERAL ASSEMBLY & BILL OF MATERIAL... 3 4 INSTALLATION DETAILS... 4 5 MAINTENANCE AND TROUBLESHOOTING... 5 5. HEALTH AND SAFETY PRECAUTIONS... 5 5.2 MAINTENANCE... 5 6 RECOMMENDED SPARES LIST... 5 7 PRODUCT SPECIFIC DRAWINGS... 6 8 DISCLAIMER... 6 Issue No Page

20 MkII Low Temperature Cell Sampler Introduction The 20 LT Cell Sampler is an adaptation of the standard 20 Cell Sampler with an extended specification to the standard 20 Cell Sampler, designed to obtain samples from pipelines at temperatures from 70 o C to +40 o C. The principle of operation and many of the component parts are identical to the standard unit, the changes being restricted to a special seal in the Bottom Plug and an extension piece to provide thermal isolation between the Cell Sampler Body and the Actuator. 2 Operating Instructions The operation of the 20 LT Cell Sampler is exactly as described in the main 20 Cell Sampler Operating and Maintenance Manual. Issue No Page 2

20 MkII Low Temperature Cell Sampler 3 General Assembly & Bill Of Material Figure - 20 LT Cell Sampler ( 900# Flanged Version shown) Issue No Page 3

20 MkII Low Temperature Cell Sampler The following components on the 20 LT Cell Sampler differ from those fitted to the standard unit: Item No Description Item No Description 3 Actuator Spacer 47 Capture Tube 37 Sample Tube 73 Bottom Plug 38 Valve Stem 78 Special Seal 4 Installation Details The standard 20 LT Cell Sampler is designed to be bolted as a "wafer" between a pair of " ANSI 50#, ANSI 300#RF or ANSI 600#RF flanges and can withstand static pressure testing to full flange rating. Alternative flange sizes and finishes may be supplied to suit specific applications. The axis of the outlet pipe connection should be horizontal or downward facing to prevent water traps. It is crucial that the flow through the bypass loop and cell sampler is adequately mixed in regard to the properties of interest. Where sampling for water content we would normally recommend the minimum flow velocity within the cell sampler and for metre upstream exceed 3.5 m/s (6 m3/hr). The Customer is responsible for the supply of an in-line check/relief valve, rated to suit the temperature of the sample and pressure of the sampling system, to be fitted between the ¼" Swagelok Sample Outlet Port in the Bottom Plug (73) and the Sample Receiver The external Check Valve must be set to either 7 Bar above the maximum operating line pressure for low pressure receiver systems or, with the exception of installations using valves unaffected by back pressure, to Barg where line balanced high pressure sample receivers are being used (i.e. where the sample is being collected at, or close to, line pressure). The outlet of the Check Valve should be connected to the Sample Receiver System via smallbore (¼" or 6mm) stainless steel tubing. Ensure that lengths of tubing are kept to a minimum to minimise "dead" i.e. trapped volume (long lengths of tubing also create extra back pressure and premature seal wear), and that the sample travels downhill at a minimum angle of 5 degrees from the Sampler Outlet to the Receiver to avoid water traps. The sample outlet piping may require heat tracing to prevent blockage. It is the Customer s responsibility to provide adequate insulation around the Cell Sampler Body and Sample discharge pipework to prevent accidental contact by the Operator. To ensure the correct operation of the Sampler, the insulation must not extend over the finned section of the Extension Tube A Sampler Solenoid Valve must be selected to suit the specific application and will require connecting to suitable supplies via glands and cables appropriate to the area classification. Note: The correct rating fuse must be included in the Solenoid Valve supply circuit. A regulated air supply must be connected to the Solenoid and the normally energised outlet connected to Port 'B' of the Sampler. The normally de-energised port of the Solenoid must be connected to Port 'A'. The exhaust port(s) of the Solenoid may be piped away or fitted with silencers as required. (On Electro-Hydraulic applications, the Solenoid is incorporated into the Hydraulic Power Pack.) If required, the bottom port (drain cavity) of the Actuator may be connected to a closed drain or a pressure switch. The Sampler Control System must be capable of supplying a pulse of a minimum 250mS duration to the Sampler Solenoid Valve to ensure that there is sufficient time for the Sampler to complete a full stroke at each actuation (in most systems using air 500ms is normal). The Actuator should dwell momentarily at the bottom of its travel before the Solenoid is deenergised and the Sampler returns to its 'rest' state. Issue No Page 4

20 MkII Low Temperature Cell Sampler 5 Maintenance and Troubleshooting 5. Health and Safety precautions In addition to the basic health and safety precautions described in the standard 20 Cell Sampler Manual, care must be taken to avoid burns from exposed metal work when the sampler is in service. 5.2 Maintenance Maintenance procedures for the 20 LT Cell Sampler are identical to that for the standard unit, with the addition of the special seal fitted to the groove in the top of the Bottom Plug. 6 Recommended Spares List When requesting assistance or spare parts, please advise the Sampler Model and Serial Numbers to ensure that the correct options are supplied. Part/Sub- Assembly Commissioning Year Operation 2 Year Operation Solenoid Valve (to suit application) - Seal Kit Comprising: 4 Slydring 5 Seal 0 O Ring O Ring 22 Seal Ring 24 Sealing Washer 25 Quadring 26 O Ring 27 O Ring 28 Double Delta seal 29 O Ring 30 Spring 32 Seal 36 Gaiter 2 4 O Ring 42 Star Washer 43 Spring 6 Seal 62 Slydring 75 Valve Seat 77 Spring 78 Special Balseal 79 Seal 80 Seal O Ring (Assembly Aid) 2 Special Tool Kit comprising: - - { Piston Lock Ring Removal Tool { Support Tube Nut Removal Tool { Support Tube Clamp { Sample Pillar Balseal Insertion Tool { Check Valve O Ring Removal Tool { Check Valve O Ring Insertion Tool { C Spanner for Stop Ring Issue No Page 5

20 MkII Low Temperature Cell Sampler 7 Product Specific Drawings Series 20 Mk II Cell Sampler (Cryogenic Version) Parts List Spare Parts List 8 Disclaimer B25257 P25260 P25269 Whilst Jiskoot Autocontrol Limited has taken every care in the preparation of this document, it cannot accept responsibility for printing errors or omissions and does not warrant that it is correct and comprehensive in every particular. Equipment supplied should always be operated by persons with an appropriate level of skill and training. Jiskoot Autocontrol Limited shall not be liable for incidental or consequential damages resulting from the furnishing, performance or use of this material. Jiskoot Autocontrol pursue a policy of continuous improvement, and information given herein may be updated without notice. Further, this information is proprietary to Jiskoot Autocontrol Limited, and must not be disclosed to any third party except as may be required to operate the equipment supplied in accordance with the purposes for which it was sold by the persons properly licensed to operate it. Minor corrections P.Whittle M.A.Jiskoot 23/3/200 Issue No Page 6

20 MkII Low Temperature Cell Sampler 0 First issued P.Whittle M.A.Jiskoot 3/9/999 Issue Revision History Issued Approved Date Issue No Page 7

20 MkII Low Temperature Cell Sampler Notes Issue No Page 8

20 MkII Low Temperature Cell Sampler Notes Issue No Page 9

20 MkII Low Temperature Cell Sampler Notes Issue No Page 0

20 MkII Low Temperature Cell Sampler Notes Issue No Page

20 MkII Low Temperature Cell Sampler Notes Issue No Page 2

DEF Tunbridge Wells, Kent, TN 2DJ, UK Tel +44 (0)892 58000, Fax +44 (0)892 5800 e-mail: support@jiskoot.com DEF Houston, TX7704, USA Tel + 28 583 0583, Fax + 28 583 0587 e-mail: jinc@jiskoot.com