M Valve Actuator Weather Shield Kit

Similar documents
M9000-3xx Series Weather Shield Enclosures

Installation Instructions

M x Series Valve Linkage Kits

M x Series Valve Linkage Kits

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

M9220-xxx-3 Electric Spring Return Actuators

M Ball Valve Linkage Kit

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

VA-7450 Series. Electric Valve Actuators

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

M Remote Mounting Kit

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

M9300 Series Potentiometer Kits

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

AD-1250 Airflow Measuring Station

M9300 Series Switch Kits

V-9502 Series Pneumatic Valve Actuator Positioners

BD-1600 Balancing/Zone Control Damper

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9210-xxx-3 Electric Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

RA-2000 Airflow Measuring System

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

P70, P72, and P170 Series Controls for High Pressure Applications

M9109 Series Electric Non-spring Return Actuators

V-2410 Three-Way Multipurpose Solenoid Air Valve

M x Series Valve Linkage Kits

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

M Ball Valve Linkage Kit

M x Series Cast Iron Flanged Valve Linkage Kit for M9000 Series Electric Actuators

VA9905 Actuator and VG1600 Series Six-Way Valves

A11 Series Low Temperature Cutout Control

M x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators

M9106-xGx-2 Series Electric Non-Spring Return Actuators

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

A25 Series Warm Air Control with Manual Reset

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

F261 Series Fluid Flow Switches

VA-715x Electric Valve Actuator

TM-11x1 Series Room Temperature Module

VA9208-xxx-xx Series Electric Spring Return Actuators

R-317 Air Flow Controller

D-3240 Series Pneumatic Piston Actuators

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

M9203-xxx-2(Z) Series Electric Spring Return Actuators

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

M9220 Series Electric Spring-Return Actuators

VA-720x Electric Valve Actuator

M9106-AGx-2N0x Series Electric Non-Spring Return Actuators

M9216 Series Electric Spring Return Actuators

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

VA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design

VA-8020 Floating Valve Actuator

M9220-xxx-3 Electric Spring Return Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

VA9208-xxx-xx Series Electric Spring-Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M Remote Mounting Kit

PP1 Series Piping Packages for VG1000 Series Ball Valves

M9206-GGx-2S Series Proportional Electric Spring Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

C-5230 Pneumatic Signal Limiter

TE-6001 Hardware Assemblies for TE-6000 Temperature Elements

VG7000 Series Bronze Control Valves

D-4070 Two Stage Pneumatic Actuator

M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No , Rev. B

RD-2000 Round Control Dampers

P70, P72 and P170 Series Controls for High Pressure Applications

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

AD-1251 Probe with Differential Pressure Transducer

Installation, Operation and Maintenance. VA(M)S24-27 (T)-T Series Actuator

PC-125x Counter-Balanced Backdraft Damper

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

P66 Series Electronic Fan Speed Controls

Features Globe Valve 2-Way & 3-Way Assembly Features:

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

M9208-xxx-x Series Electric Spring-Return Actuators

VA9104-xGA-3S Series Electric Non-Spring Return Valve Actuators

M Remote Mounting Kit

TE-6300 Series Temperature Sensors

M9208-xxx-x Series Electric Spring Return Actuators

M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications

P70, P72, and P170 Controls for Low Pressure Applications

M9300 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

Series Y63, Y64, Y65, Y66, and Y69 Transformers

ID-141x 12-Gauge Hat Channel Industrial Damper

VD-1600 Series Volume Control Dampers

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

VA-4233-AGx Series Electric Valve Actuators

TE-6300 Series Temperature Sensors

VA-4233-GGx Series Electric Valve Actuators

Damper Actuator Installation

Series P28. Oil Protection Controls. Feature and Benefits. P28DP Oil Protection Control (P) Setpoint adjusting cam

VA-715x Electric Valve Actuator

Transcription:

34-636- 2235, Rev. C M9000-341 Valve Actuator Weather Shield Kit Installation Instructions Part No. 34-636-2235, Rev. C Issued March 2016 Applications The M9000-341 Weather Shield Kit is a cost-effective and durable weather shield designed to provide a degree of protection for a single Johnson Controls VA9104, VA9203 or VA9208 Series Electric Actuator used in ball valve applications. These weather shield kits are manufactured to National Electrical Manufacturers Association (NEMA) 4X (IP66/67) specifications and protect the electric actuator from corrosion, rain, freezing rain, sleet, and snow. The kit can be mounted indoors or outdoors; however, it may not prevent externally formed ice from restricting the motion of the rotary shaft. Each enclosure is constructed of impact-grade polycarbonate plastic that provides excellent impact resistance. The cover features ultraviolet inhibitors that extend service life by preventing the cover from becoming brittle or damaged by the sun or other environmental elements. The transparent cover provides an unobstructed view of the electric actuator without having to disassemble the enclosure. A formfitting seal prevents water or moisture from entering the unit and damaging the actuator. IMPORTANT: The M9000-341 Weather Shield Enclosure only provides protection for the Johnson Controls M(VA)9000 Series Electric Actuator. To ensure proper operation, check that all associated equipment used in the application is suitable for the surrounding environment. Refer to the QuickLIT Web site for the most up-to-date version of this document. VA9203-AGx-xx Floating Electric Spring Return (Part No. 14-1380-8) VA9203-Bxx-3 On/Off Electric Spring Return (Part No. 14-1380-16) VA9203-GGx-xx Proportional Electric Spring Return (Part No. 14-1380-24) VA9208-AGx-x Floating Electric Spring Return (Part No. 14-1379-5) VA9208-Bxx-3 On/Off Electric Spring Return (Part No. 14-1379-13) VA9208-GGx-x Proportional Electric Spring Return (Part No. 14-1379-21) Special Tools Needed 8 mm (5/16 in.) open-end wrench 6 mm (1/4 in.) flat-blade screwdriver No. 1 Phillips screwdriver No. 2 Phillips screwdriver 21 mm and 22 mm open end wrench (or two adjustable wrenches) Installation Refer to the following documentation for more information on the VA9203 and VA9208 Series Electric Actuators used with the M9000-341 Weather Shield Enclosure: VA9104-xGA-3S Series Electric Non-Spring Return Valve (Part No. 14-1336-23) VA9104-xGA-2S Series Electric Non-Spring Return Valve (Part No. 14-1336-15) Figure 1: M9000-341 Weather Shield Kit M9000-341 Valve Actuator Weather Shield Kit Installation Instructions 1

Parts Included 18 1C 1B Figure 2: Parts Included in M9000-341 Weather Shield Enclosure Kit (See Table 1) Table 1: Parts Included in M9000-341 Weather Shield Enclosure Kit 1 (Part 1 of 2) Item # Quantity Description 1A 1 Base, Enclosure 1B 1 Clear Enclosure Cover 1C 4 Screw, Cover (Factory Installed) 5 1 Bearing, Seal Carrier (Factory Installed) 6 1 Seal, Lip (Factory Installed) 7 1 O-Ring, RoHS (Factory Installed) 8 1 Plate, Inner (Factory Installed) 9 4 Screw, Button Head Torx, RoHS (Factory Installed) 13 1 Bracket, Mounting 14 4 Screw, Machine, #6-32 x 1/2 in. Long, Cross-Recessed Pan Head, RoHS 15 4 Nut, #6-32 Hex, Flanged, Serrated Tooth, RoHS 16 1 Bracket, Valve 17 1 Bearing, Plastic, Flanged, Split, 20 mm ID, RoHS (Factory Installed) 18 1 Shaft, Valve 19 3 Screw, Tapping, Hex Washer Head, Type F, RoHS 20 1 Thermal Barrier, M9000-341 2 M9000-341 Valve Actuator Weather Shield Kit Installation Instructions

Table 1: Parts Included in M9000-341 Weather Shield Enclosure Kit 1 (Part 2 of 2) Item # Quantity Description 21 4 Screw, Machine, M5 X 0.8 X 20 mm Long, Cross-Recess Hex Flange, Serrated Tooth, RoHS 22 4 Nut, M5 X0.8 in. Hex, Flange, Serrated Tooth, RoHS 23 2 Gland, Cable, PG11 to 1/2 in. NPSL 24 1 Cap Plug, PG11 with O-Ring, RoHS 25 2 Nut, Hex, Single Chamfer, PG11 26 1 Label, M9000-341 (Factory Installed) 1. We recommend using a 1/2 in. liquid-tight conduit and 1/2 in. National Pipe Thread (NPT) liquid-tight fittings (purchased locally) to terminate the control wiring to the weather shield enclosure strain relief conduit fittings. Dimensions 11-7/16 (291) 9 (229) 4-23/32 (120) A Figure 3: Weather Shield Enclosure Dimensions, in. (mm) (See Table 2.) Table 2: Weather Shield Enclosure Dimensions, in. (mm) Valve Size, in. (DN) A 1/2 (DN15) 7-1/2 (191) 3/4 (DN20) 7-1/2 (191) 1 (DN25) 7-37/64 (192) 1-1/4 (DN32) 8 (203) 1-1/2 (DN40) 8-11/64 (208) 2 (DN50) 8-11/32 (212) M9000-341 Valve Actuator Weather Shield Kit Installation Instructions 3

FIG:VG1000sdB FIG:VG1000 Mounting Mount the valve in the location which allows sufficient clearance to remove the weather shield cover and actuator. Before installing the electric actuator, use an adjustable wrench to manually rotate the valve stem several times. Rotating the valve stem breaks the torque that may have built up during long-term storage. To mount the M9000-341 Weather Shield Kit: 1. Position the valve ball and stem to the desired spring return position. To mount the actuator to Spring Return Port A (Coil) Open, turn the valve stem to the position in Figure 4. To mount the actuator to Spring Return Port A (Coil) Closed, turn the valve stem to the position in Figure 5. 2. Place the Teflon thermal barrier on ball valve actuator mounting flange by inserting the alignment rib on the bottom of the thermal barrier into the recess on mounting flange (Figure 6). Figure 6: Mount the Thermal Barrier 2 Way 3 Way Figure 4: Positioning the Valve Stem - Spring Return Port A (Coil) Open 3. Install the valve adapter bracket over the thermal barrier and attach the valve adapter bracket to the valve using the four M5 screws and flanged nuts (Figure 7). Recommended torque is 35 to 44 lb in. (4.0 to 5.0 N m). Note: Before you fully tighten the screws, temporarily install the valve shaft through the adapter bracket and engage the valve stem. This action ensures proper alignment with the valve stem and adapter bracket. 2 Way 3 Way Figure 5: Positioning the Valve Stem - Spring Return Port A (Coil) Closed Note: For the VA9104 Electric Non-Spring Return Valve Actuators, position the valve ball and stem to the zero position. Turn the valve stem to the position in Figure 4. Figure 7: Install Valve Adapter Bracket 4 M9000-341 Valve Actuator Weather Shield Kit Installation Instructions

4. Secure the weather shield enclosure mounting bracket (Figure 8) to the valve adapter bracket by using the raised alignment aids (Figure 9) for positioning and the three 12-24 x 1/2 in. self tapping screws. Recommended torque is 31 to 40 lb in. (3.5 to 4.5 N m). 6. Align marks on top of the valve stem extension shaft with marks on the valve stem and install the weather shield base and seal assembly on the weather shield enclosure mounting bracket. Secure tightly using the four 6-32 x 1/2 in. screws and nuts. Torque to 9 to 12 lb in. (1 to 1.4 N m). 7. Set up the valve actuator linkage according to the instructions supplied with the actuator. 8. Install the valve actuator into the weather shield feeding the electrical cables through the strain relief conduit adapters and position the actuator on to the internal bracket. Figure 8: Weather Shield on Mounting Bracket Alignment Aids Figure 10: Actuator within M9000-341 Weather Shield Kit Note: When you use the M9000-341 Weather Shield Kit with a VA9104 Electric Non-Spring Return Actuator, you need to trim the handle for proper alignment within the kit. Figure 9: Raised Alignment Aids 5. Install the strain relief conduit adapters in the weather shield base. One adapter for actuators without switches or two adapters for actuators with switches. If you only use one adapter, seal the remaining hole with the cap plug and nut. Tighten the strain relief and/or cap plug nuts to a torque of 27 to 35 lb in (3 to 4 N m). 9. Tighten the M4x0.7 x 83 mm screw in the center of the fixed pointer to valve stem extension to a torque of 10 to 12 lb in. (1.1 to 1.4 N m). Tighten the conduit fitting to a torque of 25 to 30 lb in. (2.8 to 3.4 N m) to secure the electrical cord in place. 10. Install the weather shield cover and gasket assembly using the four cover screws supplied with the kit. Tighten to 9 to 12 lb in (1.0 to 1.4 N m). Repair Information If the M9000-341 Series Weather Shield Enclosure fails to operate within its specifications, replace the unit. For a replacement weather shield, contact the nearest Johnson Controls representative. M9000-341 Valve Actuator Weather Shield Kit Installation Instructions 5

Technical Specifications M9000-341 Weather Shield Enclosures Materials Enclosure Ultraviolet (UV) Resistant Polycarbonate Plastic Enclosure Seal Nitrile Cover Transparent UV Resistant Polycarbonate Plastic Cover Gasket Polyurethane Protection Class Designed to NEMA 4X, IP66/67 Specifications Actuator Ambient VA9203-22 to 140 F (-30 to 60 C) Operating Temperature Limits VA9208 Standard Operating: -4 to 140 F (-20 to 60 C) Extended Operating: -40 to -4 F (-40 to -20 C) VA9104-4 to 140 F (-20 to 60 C) Weather Shield Enclosure Ambient Storage -40 to 176 F (-40 to 80 C) Temperature Limits Electrical Connections Strain Relief Conduit Fittings with 1/2 in. National Pipe Straight Mechanical (NPSM) Exit Shipping Weight M9000-341 4.2 lb (1.9 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2016 Johnson Controls, Inc. 6 M9000-341 Valve Actuator Weather Shield Kit Installation Instructions Published in U.S.A. www.johnsoncontrols.com