Capacities and Operating Data

Similar documents
Design and Application Details

Eclipse Vortometric Burners Series HI

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Eclipse RatioAir Burners

Eclipse RatioAir Burners

KINEMAX. Medium velocity gas or oil burners

Design and Application Details

Data /1/07 Eclipse RatioAir Burners Model RA0040

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

Performance Selection Data

TriOx Triple Air Staged Ultra Low NOx Burner

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

MULTIFIRE. High temperature dual fuel burner

Design and Application Details


Specifications of OPTIMA SLS Burners

Design and Application Details

NOx-Beta Ultra Low NOx Burners

Start-up Instructions

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

North American 4575 HiRAM

VALUPAK. Packaged gas burners

LVDT/HC PILOT BURNER. External raw gas pilot burner

North American 4485 Tempest SE

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Assembly Numbers Style A, B & C LINOFLAME Burners

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

Assembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text)

Low emissions, high performance natural gas burners

Pilot Capacities/Specifications

APX Nozzle-mix line burner

VALUPAK. Packaged gas burners

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Economite RE Series. Power Gas Burners. MADE in the USA

KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS PRODUCT DESCRIPTION TECHNICAL CATALOG

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

BBC Multi-fuel Combination Beta Burner

Specifications of STICKTITE and PILOTPAK Nozzles

APX Nozzle-mix line burner

S1 SERIES TECHNICAL DATA INFORMATION PACKET

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

Burner Selection Criteria

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

OT LE 600/900/1200 GAS

D SERIES TECHNICAL DATA INFORMATION PACKET

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

GEMINI GAS CONTROL PRODUCT INFORMATION

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

D SERIES TECHNICAL DATA INFORMATION PACKET

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

1070 SERIES ULTRA LOW NO X

UNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M

APX Nozzle-mix line burner

2.0 Burner Operating Parameters and Requirements

North American Combustion Burners

M SERIES TECHNICAL DATA INFORMATION PACKET

Burner Settings. How to Set and Adjust Burners Why It s Necessary

North American Combustion Burners

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Model CBLE Boilers HP

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

The World s First Flameless Crude Heater

1500 Group Tips One-Piece Acetylene

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP

1470 SERIES HOT AIR GAS BURNER

Assembly Numbers. Approximate net ship weight (in pounds) shown in parentheses

Clean Burning Technology

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

1466 SERIES COLD AIR GAS/OIL BURNER

Hamilton 3VO Submittal

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

Co Gen liner upgrade project Jan 2014 Huntsman 6 B conversion to Power System Manufacturing Low emissions combustion system

PT-M90 Automatic Full-Sequence Modulation Gas Control System

Rheem Classic Series Downflow Gas Furnace

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

MAXON OVENPAK LE. Low emissions, high performance gas burners. Technical Catalog

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

VENTING & COMBUSTION AIR GUIDE

Rheem Value Series Upflow/Horizontal Gas Furnace

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

D-GASIFIER. The ultimate solution for the replacement of gaseous and liquid fuels

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

The New Coen Micro-NOx

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

Power Flame Incorporated

Transcription:

CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000 2,250,000 2,500,000 Btu/hr/f t 100,000 100,000 100,000 100,000 100,000 100,000 100,000 Turndown ratio 10: 1 12.5: 1 15: 1 17.5: 1 20: 1 22.5: 1 25: 1 Flame length f eet [ 1] 2. 7 3. 2 3. 6 4. 0 4. 3 4. 7 5. 0 P ilot pressure/heat release " w.c. * [ 2] / Btu/hr 5-8" w.c. / 40,000 Btu/hr Combustion air flow SCFM 250 313 375 438 500 563 625 A ir pressure at burner inlet ("w.c. ) [ 3] 2. 3 3. 6 5. 1 7. 0 9. 1 11. 5 14. 2 Air pressure connection Fuel pressure (natural gas) at burner test at burner inlet Fuel pressure at burner test connection (natural gas) ("w.c.)* 2. 1 3. 3 4. 7 6. 4 8. 3 10. 5 13. 0 ("w.c. ) [ 3] 8. 5 13. 3 19. 2 26. 1 34. 1 43. 2 53. 3 ("w.c.)* 7. 4 11. 5 16. 6 22. 5 29. 4 37. 3 46. 0 N Ox emissions [ 4] ppm @ 3% O < 25 ppm corrected to 3% O dry 2 2 C O emissions [ 4] ppm @ 3% O < 250 ppm corrected to 3% O dry 2 2 [1] Flame length is based on 50% excess combustion air. Flame length will vary depending on various application parameters (e.g. passing air stream velocity, oxygen content, and combustion air preheat temperature) [2] At inlet of adjustable pilot orifice. [3] Air and gas DP is differential over system static pressure. [4] Emissions stated are not guaranteed. Actual emission performance may vary. Contact Maxon for specific application details. *Differential pressures measured at burner test connections. Air and gas DP is differential over system static pressure. Operating Environment Variable Inlet Combustion Air Temp. Inlet Combustion Air O Level 2 Air Stream Cross Velocity Air Stream Axial Velocity Upstream Air Temperature Downstream Air Temperature Process Air Stream O Level 2 Minimum Maximum F Ambient 200 % O 2 20. 8 20. 8 ft/min 0 3000 ft/min 0 4000 F See Chart F Below % O 2 4 21 The burner can operate in a variety of environments. Typical operating environments, limits on their variables, and notes concerning operation of the burner are presented at left. It is important to note that inlet combustion variables such as O 2 level and combustion air temperature will change air pressure requirements and/or maximum firing capacity. F 1350 Temperature Operating Envelope Downstream Temperature 1200 1025 Consult Maxon Operating Envelope 850 100 250 500 750 F Upstream Temperature Consult Maxon for operation in shaded region. Ability to operate in shaded region is dependent upon operating conditions. 1/13

Page 5604 CROSSFIRE Line Burner Natural Gas Fuel/Air Settings Capacities and Operating Data Lower CO Lower NOx NOTE: Pressure measured at burner test connections; refer to inlet pressure requirements for fan sizing Propane Fuel/Air Settings Lower CO Lower NOx NOTE: Pressure measured at burner test connections; refer to inlet pressure requirements for fan sizing

CROSSFIRE Line Burner Page 5605 Side View (back inlet section shown) 16.6 17.8 13.35 3.2 4.6 Coupling required for ISO connection Bottom View end inlet section Coupling required for ISO connection 4.34 1-1/2 NPT Pipe Fuel Inlet 10.8 mm dia. Combustion Air Inlet Lifting Lugs.5 ft. burner = 4" dia. specified on order 1 ft. & 1.5 ft. burners - 6" dia. Bottom view back inlet section w/round air inlet (Typ.) 6.0 Bottom view back inlet section w/retangular air inlet 3.45 6.5 6.9 Gas Inlet 1-1/2" NPT Combustion Air Inlet 8" dia. 10.8 mm dia. Lifting Lugs specified per order Gas Inlet 1-1/2" NPT Combustion Air Inlet 7.5 Pilot End View 6.9 1.1 6.9 1.1 6.9 1.1 16.3 UV Scanner 3/4" NPT Spark Ignitor 14mm Gas Test Connection 1/8" NPT Pilot Fuel/Air 1/2" NPT 4.3 5.9 6.4 7.6 11.3 13.4 19.4 16.3 Combustion Air Test Connection 1/8" NPT Round air inlet 4" & 6" dia. Round air inlet 8" dia. Rectangular air inlet 6.5" W x 7.5" H 10/03

Page 5606 CROSSFIRE Line Burner Straight Burner Sections.5 ft. burner - end inlet 1 ft. burner - end inlet 1.5 ft. burner - end inlet 4.2 2.8 3.1 8.9 6.2 4.2 2.8 6.1 14.9 12.2 4.2 2.8 9.1 20.9 18.2 2 ft. burner - back inlet 3 ft. burner - back inlet 12.1 26.9 38.9 24.2 36.2 4 ft. burner - back inlet 50.9 48.2 5 ft. burner - back inlet 62.9 60.2 24.0 6 ft. burner - back inlet 74.9 72.2

CROSSFIRE Line Burner Page 5607 Straight Burner Sections 7 ft. burner - back inlet 15.0 86.9 84.2 8 ft. burner - back inlet 98.9 96.2 48.0 21.0 9 ft. burner - back inlet 27.0 110.9 108.2 60.0 10/03

Page 5608 CROSSFIRE Line Burner 26.9 2 ft. back inlet grid sections 26.9 24.2 24.2 12.1 12.1 11.7 18.9 17.7 24.9 2 BI XF GRD with 12" span 2 BI XF GRD with 18" span 26.9 26.9 24.2 24.2 12.1 12.1 14.9 36.9 23.7 30.9 29.7 2 BI XF GRD with 24" span 2 BI XF GRD with 30" span 26.9 24.2 12.1 26.9 24.2 12.1 54.9 17.9 35.7 42.9 23.9 47.7 2 BI XF GRD with 36" span 2 BI XF GRD with 48" span

CROSSFIRE Line Burner Page 5609 3 ft. back inlet grid sections 38.9 38.9 36.2 36.2 18.9 17.7 24.9 3 BI XF GRD with 12" span 3 BI XF GRD with 18" span 38.9 36.2 38.9 36.2 30.9 14.9 36.9 23.7 29.7 3 BI XF GRD with 24" span 38.9 36.2 3 BI XF GRD with 30" span 38.9 36.2 17.9 35.7 42.9 23.9 47.7 54.9 3 BI XF GRD with 36" span 3 BI XF GRD with 48" span 10/03

Page 5610 CROSSFIRE Line Burner 4 ft. back inlet grid sections 50.9 50.9 48.2 48.2 11.7 18.9 17.7 24.9 4 BI XF GRD with 12" span 4 BI XF GRD with 18" span 50.9 50.9 48.2 48.2 30.9 14.9 36.9 23.7 29.7 4 BI XF GRD with 24" span 4 BI XF GRD with 30" span 50.9 48.2 50.9 48.2 17.9 42.9 23.9 54.9 35.7 47.7 4 BI XF GRD with 36" span 4 BI XF GRD with 48" span

CROSSFIRE Line Burner Page 5611 5 ft. back inlet grid sections 62.9 60.2 62.9 60.2 11.7 18.9 17.7 24.9 24.0 5 BI XF GRD with 12" span 24.0 5 BI XF GRD with 18" span 62.9 60.2 62.9 60.2 30.9 14.9 36.9 23.7 29.7 24.0 5 BI XF GRD with 24" span 24.0 5 BI XF GRD with 30" span 62.9 60.2 62.9 60.2 17.9 35.7 42.9 23.9 47.7 54.9 24.0 5 BI XF GRD with 36" span 24.0 5 BI XF GRD with 48" span 10/03

Page 5612 CROSSFIRE Line Burner 6 ft. back inlet grid sections 74.9 72.2 74.9 72.2 11.7 18.9 24.9 17.7 6 BI XF GRD with 12" span 6 BI XF GRD with 18" span 74.9 72.2 74.9 72.2 23.7 30.9 14.9 29.7 36.9 6 BI XF GRD with 24" span 6 BI XF GRD with 30" span 74.9 72.2 74.9 72.2 17.9 35.7 42.9 23.9 47.7 54.9 6 BI XF GRD with 36" span 6 BI XF GRD with 48" span

CROSSFIRE Line Burner Page 5613 7 ft. back inlet grid sections 86.9 84.2 86.9 84.2 11.7 18.9 17.7 24.9 7 BI XF GRD with 12" span 7 BI XF GRD with 18" span 86.9 86.9 84.2 84.2 30.9 14.9 36.9 23.7 29.7 7 BI XF GRD with 24" span 7 BI XF GRD with 30" span 86.9 84.2 86.9 84.2 17.9 35.7 42.9 23.9 47.7 54.9 7 BI XF GRD with 36" span 7 BI XF GRD with 48" span 10/03

Page 5614 CROSSFIRE Line Burner 8 ft. back inlet grid sections 98.9 96.2 98.9 96.2 18.9 11.7 17.7 24.9 48.0 8 BI XF GRD with 12" span 48.0 8 BI XF GRD with 18" span 98.9 98.9 96.2 96.2 30.9 14.9 36.9 23.7 29.7 48.0 8 BI XF GRD with 24" span 48.0 8 BI XF GRD with 30" span 98.9 96.2 98.9 96.2 17.9 35.7 23.9 47.7 54.9 42.9 48.0 8 BI XF GRD with 36" span 48.0 8 BI XF GRD with 48" span

CROSSFIRE Line Burner Page 5615 9 ft. back inlet grid sections 110.9 108.2 110.9 108.2 18.9 11.7 17.7 24.9 72.0 72.0 9 BI XF GRD with 12" span 9 BI XF GRD with 18" span 110.9 108.2 110.9 108.2 23.7 30.9 14.9 29.7 36.9 72.0 72.0 9 BI XF GRD with 24" span 9 BI XF GRD with 30" span 110.9 110.9 108.2 108.2 17.9 35.7 23.9 47.7 42.9 54.9 72.0 9 BI XF GRD with 36" span 72.0 9 BI XF GRD with 48" span 10/03

Page 5616 CROSSFIRE Line Burner Horizontal spacing of CROSSFIRE ladders 62.9 48.0 7.5 typ. 4 ft. CROSSFIRE Ladder 74.9 60.0 7.5 typ. 5 ft. CROSSFIRE Ladder 86.9 7.5 typ. 6 ft. CROSSFIRE Ladder 15.0 15.0 98.9 42.0 42.0 7.5 typ. 7 ft. CROSSFIRE Ladder 15.0 15.0 33.0 33.0 110.9 48.0 48.0 7.5 typ. 8 ft. CROSSFIRE Ladder 15.0 15.0 3 3 122.9 54.0 54.0 7.5 typ. 9 ft. CROSSFIRE Ladder 15.0 15.0 45.0 45.0

CROSSFIRE Line Burner Page 5617 Vertical spacing of CROSSFIRE ladders Dim. A Dim. B Designation Cross Member Description Dim. A (inches) Dim. B (inches) 112 1-12" spacing 12 24 118 1-18" spacing 18 36 124 1-24" spacing 24 48 130 1-30" spacing 30 60 Dim. A Dim. B Designation Cross Member Description Dim. A (inches) Dim. B (inches) 212 2-12" spacing 12 36 218 2-18" spacing 18 54 224 2-24" spacing 24 72 230 2-30" spacing 30 90 Dim. A Dim. B Designation Cross Member Description Dim. A (inches) Dim. B (inches) 312 3-12" spacing 12 48 318 3-18" spacing 18 72 324 3-24" spacing 24 96 330 3-30" spacing 30 120 Dim. A Dim. B Designation Cross Member Description Dim. A (inches) Dim. B (inches) 412 4-12" spacing 12 60 418 4-18" spacing 18 90 424 4-24" spacing 24 120 430 4-30" spacing 30 150 See page 5616 for horizontal spacing of CROSSFIRE ladders 10/02

Page 5618 CROSSFIRE Line Burner Notes