AC INVERTER WITH SOLAR CHARGE CONTROLLER MAX+ 1K/2K/3K/5K 1K 2K Built-in Solar Charger Faster charging with solar power even during AC mains outage MPPT* controller to maximize solar energy harvest(3k/5k) Clear charging status on LCD 5K 3K Extended Run Time When solar power presents, the battery run time can be largely extended 98% Excellent Performance Up to 98% efficiency in line mode Works under 0~50 C environment Wall-mounting design for space saving MAX+ is a reliable AC inverter with built-in solar charger controller allowing the battery tobechargedbynotonlyacmainsbutalso solar power. *MPPT=Maximum Power Point Tracking
Typical Application +
Product Outlook (1K/2K) LED LCD Display 1 2 3 4 5 PV Input terminals AC output receptacle AC input receptacle Battery terminals DC Fan Power Button Control Buttons Enter/Exit button for setting mode Move on to next selection page Confirm the selection
Product Outlook (3K/5K) 5K LCD Display 3K Control Buttons AC Input & Solar Input Battery Connector
Product Outlook (3K/5K) 3K 5K 1. LCD display 2. LCD Configuration button: Enter configuration mode, and switch between setting menus 3. LCD up/down button: Move to previous/next setting option 4. LCD ESC button: Return to main menu 5. LCD Enter button: Confirm setting 6. AC input circuit breaker 7. Power ON/OFF switch 8. PV input 9. AC input 10. AC output 11. AC Input & output GND 12. Battery input
Design of Graphic LCD Visualized icons to indicate the operation modes Optimized design on LCD allows user to understand the operational status at a glance MAX+ 1K/2K MAX+ 3K/5K Clear power flow between AC input, solar input, battery and loads Clear readings for Power/Voltage/Loading/ Battery
Operation Modes PV Power present Less PV Power No PV Power AC Input Power Present LINE MODE 2 LINE MODE 1 AC Input Power Absent BACKUP MODE 3 BACKUP MODE 2 BACKUP MODE 1
Operation Mode Line Mode LINE MODE 1 AC input power is present but there is no PV power (e.g. night time). Load is supplied by AC input power directly. LINE MODE 2 Both AC input and PV input are present. Load is supplied by either AC input or PV input depending on the priority switch s setting. Priority Setting Switch In LINE MODE 2, if priority setting is Solar first or SBU,and PV power is also strong enough to support load, the AC input will not be consumed even though it is present. This is deemed an energy-saving operation.
Operation Mode Backup Mode BACKUP MODE 1 Both AC input and PV input are absent. The backup power to load only comes from battery. The backup time is determined by the capacity of battery. BACKUP MODE 2 AC input is absentand PV power is not enough to support loads completely. The insufficient power is covered by battery. The larger PV power, the less consumption from battery and therefore the longer backup time. BACKUP MODE 3 AC input is absent and PV power is strong enough to not only support the load but also charge the battery. As long as the PV power persists, the load can be powered continuously without consuming power from battery extended battery run time
Standby Charging Mode When AC input cable (from AC mains or generator) and battery is connected, the inverter will enter into Standby Charging Mode and LCD will be turned on (as shown right). But if charger priority setting is only solar, utility won't charge battery. If PV string is also connected with enough voltage, the display will be as shown right to indicate the power flow from PV string. Except only solar setting for charger priority. Even if AC input is absent, PV power can still charge the battery and the display will be as shown right.
Specification(1K/2K) MODEL MAX+ 1K MAX+ 2K CAPACITY 1200VA/900W 2000VA/1600W Nominal Input Voltage 230V AC AC INPUT Input Voltage Range (normal range) 1 170-280V AC Input Voltage Range (wide range) 1 90-280V AC Nominal Output Voltage 230V AC AC OUTPUT Output Voltage Waveform Modified Sine-wave Output Voltage Regulation (Bat. Mode) -18%/ +10% Output Frequency 50Hz / 60Hz ± 1Hz AC CHARGER Nominal BatteryVoltage 12V DC 24V DC (charged by AC mains) Charger Current 0A/5A/10A/20A selectable 0A/5A/10A/15A selectable SOLAR OUTPUT Max. Solar Charger Current 60A Max. Solar Power Rating to support load 600W 1200W Max. Solar Panel Array Power 2 1050W 1750W SOLAR PANEL Max. Solar Panel Output Current 65A PARAMETERS Max.Solar Panel Array open voltage 55V DC Optimal Work Voltage Range 16-18V DC 30-32V DC EFFICIENCY AC to AC >95% DC to AC >80% Transfer Time Line Mode Battery Mode 15ms (narrow range setting) 40ms (wide range setting) DISPLAY 1 x LCD, 3x LED indicators DIMENSION WxHxD 243 x 308 x 94 mm NET WEIGHT 2.5kg 2.4kg Operating Temperature 0-50 ENVIRONMENT Noise Level <50dB Note: 1. Normal input range and wide input range can be configured via LCD. 2. The installed capacity of solar panel shall be no larger than this value.
Specification(3K/5K) MODEL MAX+ 3K MAX+ 5K CAPACITY 3000VA/2400W 5000VA/4200W Nominal Input Voltage 230V AC AC INPUT Input Voltage Range (normal range) 1 170-280V AC Input Voltage Range (wide range) 1 90-280V AC Nominal Output Voltage 230V AC Output Voltage Waveform Pure sine wave AC OUTPUT Output Voltage Regulation (Bat. Mode) ±10% Output Frequency 50Hz / 60Hz ± 1Hz Max Motor-based Loading 1.5HP 2.5HP AC CHARGER Nominal BatteryVoltage 24V DC 48V DC (charged by AC mains) Charger Current 0A/2A/10A/20A selectable 0A/2A/10A/25A selectable SOLAR OUTPUT Max. Solar Charger Current 80A Max. Solar Power Rating to support load 1600W 3200W Max. Solar Panel Array Power 2 2000W 3750W SOLAR PANEL Max. Solar Panel Output Current 50A PARAMETERS MPPT Operating Voltage Range 30-80V DC 60-150V DC MPPT Optimal Work Voltage Range 35-70V DC 70-120V DC EFFICIENCY AC to AC >98% DC to AC >90% Transfer Time Line Mode Battery Mode 10ms (narrow range setting) 20ms (wide range setting) DISPLAY 1 x LCD DIMENSION WxHxD 268 x 342 x 94mm 394 x 436 x 118mm NET WEIGHT 5.7kg 10.3kg Operating Temperature 0-50 ENVIRONMENT Noise Level <60dB Note: 1. Normal input range and wide input range can be configured via LCD. 2. The installed capacity of solar panel shall be no larger than this value.
APPENDIX
Configuration Highlight (1) Output Source Priority Solar first (default): Solar energy provide power to the loads as first priority. If solar energy is not sufficient to power all connected loads, battery energy will supply power to the load at the same time. Utility provides power to the loads only when any below condition happens: -Solar energy is not available -Battery voltage drop to either low-level warning voltage or the setting point. Utility first: Utility will provide power to the loads as first priority. Solar and battery energy will provide power to the load only when utility power is not available. SBU: Solar energy provides power to the loads as first priority. If solar energy is not sufficient to power all connected loads, battery energy will supply power the load at the same time. Utility provides power to the loads only when battery voltage drop to either low-level warning voltage or the setting point. It is deemed an energy-saving operation newly-added priority setting in MAX+
Configuration Highlight (2) Charger Source Priority Solar first: Solar energy will charge battery as first priority. Utility will charge battery only when solar energy is not available. Utility first: Utility will charge battery as first priority. Solar energy will charge battery only when utility power is not available. Solar and Utility (default): Solar energy and utility will charge battery at the same time. Only solar: Solar energy will be the only charger source no matter utility is available or not. It is deemed an energy-saving operation newly-added priority setting in MAX+
Configuration Highlight (3) DC transfer voltage to battery mode when selecting "Solar first" or SBU MAX+ 1200 options: Full/12.5V/13V/13.5V(default)/14.0V MAX+ 2000/3000 options: Full/25.0V/25.5V/26.0V/26.5V/27.0V(default)/27.5V/28.0V MAX+ 5000 options: Full/50V/51V/52V/53V/54V(default)/55V/56V DC transfer voltage to utility source when selecting Solar first or SBU MAX+ 1200 options: 10.5V/11.0V(default)/11.5V/12.0V MAX+ 2000/3000 options: 21.0V/21.5V/22.0V(default)/22.5V/23.0V/23.5V/24.0V/24.5V MAX+ 5000 options: 42V/43V/44V(default)/45V/46V/47V/48V/49V Max Charging Current = utility charging current + solar charging current MAX+ 1200 options: 20A/30A/40/50A/60A(default)/70A/80A MAX+ 2000 options: 20A/30A/40/50A/60A(default)/75A MAX+ 3000 options: 20A/30A/40/50A/60A(default)/70A/80A/90A/100A MAX+ 5000 options: 20A/30A/40/50A/60A(default)/70A/80A/90A/105A These parameters can be configured via LCD according to the battery capacity extended battery life and extensive application, newly-added setting in MAX+
Configuration Highlight (4) Low DC cut off voltage Auto(default): low DC cut off voltage will be relate to load percent. MAX+ 1200: 10.0V @ >=60%load, 10.5V @ <60%load MAX+ 2000/3000: 20.0V @ >=60%load, 21.0V @ <60%load MAX+ 5000: 40.0V @ >=60%load, 42.0V @ <60%load MAX+ 1200 setting: 10.0V to 12.0V, 0.2V per step MAX+ 3000 setting: 20.0V to 24.0V, 0.2V per step MAX+ 5000 setting: 40.0V to 48.0V, 0.4V per step These parameters can be configured via LCD according to the battery capacity extended battery life and extensive application, newly-added setting in MAX+
Let us have your feedback What application will be mostly meet by this product? Backup power for Home appliance Remote house Farm/Factory What power rating is preferred in the market you may access? <500W 500-999W 1000-1999W 2000-4999W 5000W above What is your expectation on backup time? few minutes 30 minutes > 1hour Which key specifications of MAX+ you think can be improved to meet the market demand? Power factor Transfer time Charging current Protection degree