RM 12V/24V Series Solar Charge Controller User s Manual

Similar documents
User Manual. Solar Charge Controller 3KW

User s Manual Wind/Solar Hybrid Controller

User s Manual. Wind/Solar Hybrid Controller. Please Read This User Manual Carefully Prior to Installation and Operation of This Product V1.

USER MANUAL MPS 1-5KW SERIES

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

User Manual Solar Charge Controller 3KW

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

Wind/Solar Hybrid Controller User Manual. Model: HY-C10-24AWM and HY-C10-48AWM

SCC-MPPT Solar Charge Controller

Advanced Wind/Solar Hybrid Controller

Solar Charge Controller

3KW Off-grid Solar Power System LFP Battery

SCC-MPPT Solar Charge Controller

emppt30 Series Solar Charge Controller User s Manual

SCC-MPPT Solar Charge Controller

WP Series Solar Charge Controller User s Manual. Please read this manual carefully before using this product.

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

Maximum Power Point Tracking (MPPT) KA1224MPPT20A KA1224MPPT40A. Solar Charge Controller. User Manual 20A

SMPPT. Solar Charge Controller with Maximum Power Point Tracking. Installation & Operation Manual

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Owner s Manual. Advanced Wind/Solar Hybrid (Street Light) Controller

Advanced Hybrid Wind / Solar Charge Controller. User Manual

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Portable Solar Power Battery Pack User's Manual

PVES Series User Manual User Manual Shenzhen Pvinergy Technologies Co., Ltd

Wind/Solar Hybrid Controller (Boost/Buck) User Manual

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

UGE-4K Off-Grid Controller OWNER S MANUAL

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

CPS Energy Balancer. Version: 1.0

Installation and Operating Instructions. Solar System Controller ISC3020

MPPT Maximum Power Point Tracking Series

Operating Manual MP-3739

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

PV Generation System. Solar Charge Controller SPECIFICATION

GSM Series MPPT PV Controller. Version 1.0. Manual

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

PWM Charge Controller with LCD Display 30A. User Manual

MPPT SOLAR CONTROLLER FOR MODELS: 20A baterai 12V 24V

8 Troubleshooting and Maintenance

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

USER S MANUAL SOLAR POWER INVERTER KW-6KW

Instruction of Solar Charge Controller. User s Manual

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

SC SERIES SOLAR CONTROLLER USER MANUAL Ver 1.0

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

UPS Rack Mount Series (1-3KVA) User s Manual

PSC-A20 Solar Charge Controller Manual

Pure sine wave charger inverter Product Manual

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual 1KVA-5KVA INVERTER / CHARGER

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

Off Grid Solar Inverter. LVS 50M User Manual

*Please read the manual before installation. Professional Wind & Solar Hybrid Controller Manual

Electronic Ballast EVG 2000-T

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Installation and Operating Instructions. Solar System Controller ISC3030

Eclipse Solar Suitcase

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

20A\30A\40A\50A\60A. Maximum PV(voc) Voltage: DC150V

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

User Manual. Wind and Solar Hybrid Charge Controller 1KW / 2KW 48VDC. HCON Series

User Manual. Hybrid PV Inverter. Version: 2.1

HP Series Smart Solar Charge Controller User Manual HP2410/HP2420/HP2420-S

The Traveler Series: Wanderer

Lithium-ion Battery Manual for After Sales Service

MPPT5012A-DUO-BT MPPT5025A-DUO-BT

SR-MT Maximum Power Point Tracking Series. User Manual

USER MANUAL. PSC Plus3K Series Hybrid Inverter

APPENDIX: APPROCIMATR BACK-UP TIME TABLE

User Manual. 3kW Hybrid PV Inverter HX-3000

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

MPPT Solar Charger With Constant Current Driver

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

PWM WIND(SOLAR) CONTROLLER USER MANUAL

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

User Manual. Grape Solar ZENITH Series Solar Charge and Load Controller. 12V/ 24V with Auto-Recognition 20A 40A 20A

Professional Wind & Solar Hybrid Controller Manual

The Traveler Series: Adventurer

4TCH Submersible Pumps. Installation and Operating Manual

10KW Portable EV Charger

PANcharge1k Battery Charger User's Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

PWM Charge Controller with LCD Display 10A 20A. User Manual

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Instruction of Solar Charge Controller. User s Manual

User Manual 1.5KVA-3KVA INVERTER / CHARGER

Instruction of Solar Charge Controller. User s Manual

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

TECHNICAL DATA SHEET KVA UPS Systemss

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Transcription:

RM 12V/24V Series Solar Charge Controller User s Manual

Notice Before operating the product, please read this User Manual carefully to understand its correct usage. After reading it, please keep it properly for future reference. Warning The input and output voltage of this equipment is the dangerous high voltage, which can endanger the personal life. Please strictly follow all warns and operating instructions on the machine and in the Manual. The professional maintenance personnel without authorization are not allowed to disassemble the outer cover of the machine case of this equipment. 1. Please read this User Manual carefully before using the equipment and use it according to the requirement of the User Manual. 2. During running of this equipment, please do not touch the power supply input and output wires to avoid electric shock. 3. Please do not open the outer cover of the equipment without authorization, because there is the danger of electric shock. 4. Please first turn off the switch of the solar polar plate and then the switch of the backup battery in any emergency case. 5. You must ensure reliable earthing of the equipment before it is connected. 6. The backup battery pack should be kept away from the source of ignition and all electrical equipment which can easily cause spark, to avoid danger or losses. 7. Please do not open or damage the backup battery. The leaked electrolyte is corrosive, which is harmful to personal health. 8. The backup batteries with different brands and different types require different charging voltages. Please ensure that the charging voltage of the equipment matches the backup battery before using them. In case of any doubt, please consult the manufacturer. 9. In case of any problems, please consult the professional personnel of the dealer or authorized service shop, rather than solve it without authorization. 10. This equipment must be installed and maintained by professionals. 11. Please do not arbitrarily set up the parameters in the equipment menu, which should be set up by the professional personnel or through consulting the manufacturer. 12. The change of the system configuration, structure and component will impact the equipment performance. If you want to carry out such operation, please consult the manufacturer in advance. 13. Please ensure that the temperature of the product returns to the normal working temperature range before using it. It is suggested to place the product within the working temperature range for 24 hours before starting up.

Contents Chapter 1 Overview... 1 1.2 Product Introduction... 1 1.2.1 Product Features... 1 1.2.2Technical Index... 1 Chapter 2 Basic principle and structure...3 2.1 Stand-alone Principles... 3 2.1.1 Block Diagram of the Operating Principles... 3 2.1.2 Operating Principles... 4 2.2 Structure of the Main Engine... 5 2.2.1 Outline Structure... 5 2.2.2.1 Notes for Wiring... 7 2.2.2.2Diagram of the Amphenol Connector... 7 2.2.2.3 Use Operation Steps... 8 2.2.3 Instruction about the Human-computer Interface of the LCD Display Panel... 8 Chapter 3 Maintenance Instruction... 11 3.1 Common Faults and Troubleshooting Process... 11 3.1.1 Preventive Periodic Maintenance... 11 3.1.2 Fault Maintenance Steps... 11 3.1.3 Maintenance Operation Steps... 11 3.1.4 Maintenance of the Solar Cell Plate... 12 3.1.5 Other Maintenance... 12 3.1.6 Diagnosis of the Common Abnormities... 12 Chapter 4 Transportation and Storage... 13 4.1 Transportation... 13 4.2 Storage... 13

Dear customer, thank you very much for your use our company research and development production RM series solar controller..we sincerely hope our products can meet your needs, at the same time also hope you can are proposed on the performance of the product more valuable advice.we will continue to improve product quality. The purpose of this manual is to provide detailed product information to the readers and the controller operation and maintenance instructions.please read this manual carefully before use! When you receive equipment, whether to comply with the following list, please check the equipment and accessories. If found lost, please contact us as soon as possible. title quantity unit remark Charge Controller 1 pcs Terminals 6 pcs M4 Screw 4 pcs For install the controller on the wall Gallow pulley 4 pcs For install the controller on the wall User manual 1 pcs warranty card 1 pcs Temperature sensor 1 pcs optional

Chapter 1 Overview 1.2 Product Introduction 1.2.1 Product Features Subdivision control of charging and discharging and intelligent battery management; MPPT computing control and the follow-up accuracy reaches 99.5%; Wall mounting type, front display and input and output wires at the bottom; Pole sharing control mode and multichannel solar matrix input control; Core technology of the intelligent MCU control and professional control computing to achieve the intelligent control; RS485 remote communication and data transmission; Accurate measurement display of the photovoltaic generation and it can accurately record the total photovoltaic generation; Have the input anti-transposition protection/ undervoltage protection, overvoltage protection, overtemperature protection, output overvoltage protection, input overcurrent protection, output short-circuit protection, input and output anti-position protection, battery undervoltage protection and so on; LED visually displays various current information and the user can understand the operating conditions of the system at any time; Comprehensive LCD display interface and English menu display; The user can set up the output voltage parameter and it has the function to save the power failure; Have the function to save the historic alarm records; 1.2.2Technical Index Table 1-1 Main Technical Index of the RM12V/24V Series of Machine 24V/12V System Model RM-60-12/24 RM-50-12/24 RM-40-12/24 RM-30-12/24 RM-20-12/24 RM-10-12/24 Remarks Input working voltage range Maximum input voltage Maximum input power 750W (12V 1,500W (24V 625W (12V 1,250W (24V 18V-90V (12V 35V-90V (24V 500W (12V 1,000W (24V 93V 375W (12V 750W (24V 250W (12V 500W (24V 125W (12V 250W (24V - 1 -

Maximum input current Floating charging voltage Equal charging voltage Charging protection voltage Maximum charging current Discharging protection voltage Maximum discharging current Maximum load power Max Conversion efficiency Use ratio of the photovoltaic module Operating environment temperature Operating altitude Protection class Dimension (width*depth*hei ght) User Manual of the RM12V/24V Series of Solar Charge Controller 60A 50A 40A 30A 20A 10A 13.6V (12V 27.2V (24V 14.3V (12V 28.6V (24V 14.6V (12V 29.2V (24V 60A 50A 40A 30A 20A 10A 10.5V (12V 21V (24V 60A 50A 40A 30A 20A 10A 750W (12V 1,500W (24V 625W (12V 1,250W (24V 182 205 81mm 500W (12V 1,000W (24V 95% 99% -20~+50 3,000 IP20 375W (12V 750W (24V 250W (12V 500W (24V 170 190 72mm 125W (12V 250W (24V Can be set up through the LCD panel Can be set up through the LCD panel Can be set up through the LCD panel Can be set up through the LCD panel Can be set up through the LCD panel Can be set up through the LCD panel Can be set up through the LCD panel Can be set up through the LCD panel 90% for 12V system When the altitude exceeds 3,000m, 1 should be reduced for each additional 200m. Including the hanger width The index specification will be subject to the change without prior notice. - 2 -

Chapter 2 Basic Principles and Structure 2.1 Stand-alone Principles 2.1.1 Block Diagram of the Operating Principles Photovoltaic matrix Solar photovoltaic intelligent controller DC equipment Backup battery pack Figure 2-1 Block Diagram of Operating Principles of the RM Series of Solar Charge Controller Figure 2-2 Block Diagram of Operating Principles of the RM Series - 3 -

2.1.2 Operating Principles User Manual of the RM12V/24V Series of Solar Charge Controller This product is the photovoltaic DC supply control system designed for the DC load and front DC input part of the DC input inverter and its purpose is to achieve the input control system composed of the solar matrix input and battery pack input and provide the DC load with power through the management of the backup battery charging by the controller or provide the AC load with power through inverter, thus completely and reasonably store and apply the solar energy to reach the purpose of being green and energy saving, which is designed for the power supply of the communiction nor monitoring equipment in the remote areas. The human-computer interface of this product can particularly display the operating parameters and operating condition of all input modules, output real-time parameter, statistics of the photovoltaic generation, various protection functions, LED indicator light alarm and so on. The system mainly includes the solar matrix, energy storing device (backup battery pack), solar photovoltaic controller and DC equipment. The soloar photovoltaic power generation is to convert the solar energy into DC electric energy through the photoelectric effect of the solar cell module and store it. The solar power supply system is consisted of the photovoltaic matrix composed of the solar cell modules, solar photovoltaic controller, backup battery pack, DC equipment and so on. The sun can convert the solar energy into electric energy when there is sunshine and the power is supplied to the load through the solar photovoltaic controller and the backup battery pack is charged at the same time. The solar photovoltaic controller is the control center to connect the photovoltaic matrix, various electrical facilities and backup battery pack. Various control functions of the solar photovoltaic system can be achieved through the adjustment and allocation of the input and output power of the system. - 4 -

2.2 Structure of the Main Engine 2.2.1 Outline Structure Figure I RM-60-12/24/RM-50-12/24/RM-40-12/24 Structure Dimension (186 205 81.5mm) - 5 -

Figure II RM-30-12/24/RM-20-12/24/RM-10-12/24 Structure Dimension (190 170 72mm) Notes: The outline dimension is made according to the non-standard customization, while the installation dimension of the wall mounting type is shown in the above Figure (unit: mm) and the screw dimension is M4. - 6 -

2.2.2 Wiring and Running 2.2.2.1 Notes for Wiring User Manual of the RM12V/24V Series of Solar Charge Controller 1. Before wiring, please confirm that the backup battery is in the disconnection state, i.e. the power supply is disconnected. 2. Before wiring, please carefully check the wiring bank polarity marking (pole sharing for this equipment). 3. When the photovoltaic connection is carried out, the positive and negative poles of the photovoltaic input should be confirmed. It is not allowed to reversely connect them. 4. The negative poles of the backup battery and photovoltaic module are not allowed to be earthed. 5. Before wiring, please confirm whether the backup battery voltage is consistent with that of this equipment. 6. Before wiring, please confirm whether the photovoltaic input voltage is consistent with that of this equipment. 7. The insulated cable with copper core is selected for the connecting wire (with the maximum wire diameter of 10 mm 2 ) and the cable is selected according to the carrying capacity of 5A/ mm 2. When wiring, please ensure that the terminal is well contacted to prevent overheat when there is high current. 8. The earth terminal must be reliably earthed. 2.2.2.2Diagram of the Amphenol Connector RJ45 signal definition(standard configuration RS485,LAN optional) - 7 -

2.2.2.3 Use Operation Steps User Manual of the RM12V/24V Series of Solar Charge Controller 1. Confirm that all wirings are correct and wiring polarity is correct. 2. Connect the input breaker of the solar cell and the RUN light will light up. 3. The LCD display and parameter setting are correct. 4. Various parameters of this machine have been set up when it left the factory. If there is no special requirement, the default factory value will be taken after the machine is started up. The customers can set up the relevant parameters by themselves if they have requirements. 5. If the machine should be shut down, please first disconnect the photovoltaic input breaker and then those of the backup battery and electrical equipment to shut it down. 2.2.3 Instruction about the Human-computer Interface of the LCD Display Panel PV Indicator Light Load Indicator Light Alarm Indicator Light Main LCD Display Screen Up Page Up Key Down Page Down Key OK OK Key Battery On Key Instruction Logo PV indicator light LOAD indicator light Fault indicator light Indicator light color Green Green Red Normal state Light up Light up OFF Abnormal state Flash or go out Flash Flash or light up Cause of abnormity It will light up when the operation goes well, it will go out when there is PV undervoltage and it will flash when there is PV overvoltage. It will light up when the load is normal, while it will flash when there is overcurrent, the battery has low voltage and the load has short circuit. It will go out when the operation goes well, it will light up when the module has fault, the battery has short circuit, the load has short circuit and there is overtemperature protection and it will flash when there is PV overvoltage. - 8 -

Operating instructions of the key functions of the front panel: a. UP Page Up Key: turn up the menu and the value increases when the parameter is set up; b. OK OK Key: enter the menu and return to the last menu; Click >OK (save the data); c. Down Page Down Key: turn down the menu and the value decreases when the parameter is set up. d. Clear history: press OK at the same time in the history interface more than 3 s e. Clear Power generation: press OK at the same time more than 3 s The display instructions of the main display screen: - 9 -

Menu Hierarchy NO. First Menu Second Menu Remarks 1 Model Software version 2 Measure Vout Ibat Vpv ILoad Btemp Power Out Voltage Battery Current PV Voltage Load Current Battery temperature TG DG Float 3 Charge Status Equal Password check Float Voltage Equal Voltage Battery Capacity Temp compensate Charge Radio Password Change Address 4 Setting (default:8888) Load OFF Voltage Mppt Status Battery Type Factory Default Source IP Destination IP Mask IP Source Port Destination IP PV status Bat Status 5 Alarm info Temp Status Load Status 6 History Record Show the history alarm records 7 Time&Data Dispaly Setting Data&Time Total generation Day generation Need professional guidance - 10 -

Chapter 3 Maintenance Instruction 3.1 Common Faults and Troubleshooting Process 3.1.1 Preventive Periodic Maintenance In order to enhance the reliability of the operation of the solar charge controller, please complte the following preventive maintenance operations: 1.Keep the environmental health to avoid dust or water drop to the controller. 2.Check whether the input and output amphenol connectors are well contacted once every severy months. 3.Check the operating environment of the equipment and the controller should be used in the clean and ventilated place. 4. When several power supplies are used together, the front space of the power supply rack should be possibly expanded and the equipmetn such as air-conditioner or fan etc. should be installed if possible. 5. The running records should be made for the daily running. 6.Periodically check the historic records of the controller. 3.1.2 Fault Maintenance Steps 1.Check the historic fault records in LCD. 2. Check whether the relevant parameter setting is incorrect or unreasonable. 3.Check wether the photovoltaic input voltage falls into the specified range. 4.Check whether there is error between the actual battery voltage and displayed voltage. 5.Check whether the charging loop is normal. 6.Reset the system to check whether it can recover to the normal status. 3.1.3 Maintenance Operation Steps 1. First disconnect the photovoltaic input breaker and then the battery input breaker. 2. Disassemble the wiring such as the ground wire of the photovoltaic input, backup battery, rack connection and so on using the tools such as screwdriver etc., mark the positve and negative poles and wrap up the connectors of the connecting wires using the insulated tape (or heat-shrinkable tubing, fiber tubing etc.) to prevent the short circuit with other leads. 3. Loosen the fixing screws of the case cover of the controller and then maintain or replace the machine. 4. After the machine is maintained or the new controller is replaced, lock the case cover of the controller using the screws, connect the wiring of the ground wires of the photovoltaic input, backup battery and rack connection etc. then conduct the power-on operation according to the use operation steps in 2.2.2.3. - 11 -

3.1.4 Maintenance of the Solar Cell Plate The solar photovoltaic plate is an integral part of the solar photovoltaic power generation system and is related to the photovoltaic use efficiency of the whole system, thus the installation soundness of the photovoltaic plate and cleanness of the cell plate surface must be guaranteed. 1. Ensure to first disconnect the photovoltaic polar plate, then the output and backup battery and the order should be not reverse. 2. Often check whether the installation of the photovoltaic polar plate is solid. 3. Carry out the electric leakage check for the wire connectors to avoid the electric leakage on the rainy and snowy day. 4. Periodically clean and maintain the polar plate surface. 3.1.5 Other Maintenance The handling measures after the faults occur: 1. For the general faults of the equipment, please carefully read this manual. On the premises of having sufficient confidence, make judgment and troubleshooting according to the manual. 2. In case of the faults which cannot be removed, the maintenance must be carried out by the professional technician or directly contact us. 3.1.6 Diagnosis of the Common Abnormities If the controller cannot normally work after you start it up or the abnormity occurs after it works for a while, you can find out the possible causes by referring to Table 3-1. Meanwhile, please note to check whether it is caused by the external environment, such as the temperature or humity does not meet the requirement. If it cannot still work normally after handling according to the methods in Table 3-1, please hand it over to the professional personnel for maintenance. This section only includes some simple fault diagnosis procedure. If the diagnosis result is unclear, or the obtained information is insufficient for the problem solving, please contact the local office or distributor of our company for handling. Table 3-1 Reference Table for Fault Diagnosis No. Phenomenon Cause Handling Method 1 a. The PV power supply loop is disconnected. b. The PV power supply voltage does not a. Connect the PV power supply loop b. Adjust the PV power supply After the PV input switch is switched on, the LCD has no display. match the battery voltage of this equipment. c. The voltage polarity of the PV power supply is reversely connected. d. The plug is loosened due to transportation vibration. e. LCD is damaged due to extrusion or impact. voltage to the normal value c. Correctly connect the PV power supply d. Disassemble the machine case and plug again e. Send it to the local office for maintenance 2 Immediate undervoltage awarm or protection after powering on. 3 Immediate overvoltage awarm or protection after powering on. 4 After the Battery is connected, LCD has no display. a. The backup battery voltage is too low. b. Whether the DC loop wiring is loosened. a. The backup battery voltagedoes not match the battery voltage of this equipment. a. Do not press the key BAT-ON(ON) of LCD; b. The battery voltage does not fall into the normal range; a. Adjust the backup battery voltage. b.check whether the wiring is solid. Adjust the backup battery voltage to the normal value a.press the key BAT-ON(ON) of LCD to start up the auxiliary powre supply; b. Adjust the battery voltage to the normal value - 12 -

Chapter 4 Transportation and Storage 4.1 Transportation During handling, please handle with care. The warning signs on the packing box should be strictly followed. When being transported, it should be placed in strict accordance with the direction indicated on the packing box to avoid the device damage due to vibration. For the long-distance transport, it is not allowed to be packed in the open vehicles or ship. It should be not packed with the inflammable and explosive articles. When it is transshipped on the way, it should be not stored in the open air. During transportation, it should be kept away from rain, snow or other liquid substance, long-term basking of sunshine and mechanical damage and so on. 4.2 Storage When the equipment is stored, the placement direction should strictly follow the direction indicated on the packing box. The packing box should be cushioned with 20cm away from the ground and at least 50cm away from the wall, heat source, cold source, window or air inlet. The environment temperature of storage is -40~70 and the relative humidity is 93%. There should be no various harmful gases, inflammable or explosive articles and corrosive chemicals in the warehouse and there should be no strenuous mechanical vibration, impact and strong action of a magnetic field. The storage period is generally 6 months under the conditions specified in this article if there are no other regulations. When it exceeds 6 months, the inspection should be carried out again. - 13 -