GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA - 390 007 TENDER FOR Design,Engineering, manufacturing, supply, erection, testing & commissioning of 66 kv HYBRID equipments, materials on turn key basis including all civil works related to Hybrid at 66KV Tragad S/S, Ahmedabad & 66KV Nilkanth S/S, Rajkot. TENDER NO : GETCO / TURN KEY /66KV Tragad & Nilkanth/60 PART III Price Bid Sign & seal of Bidder 1
This page has been kept intentionally Blank. Sign & seal of Bidder 2
SUMMARY Sr No Name of S/S Supply Erection 1 66 kv Tragad S/S. 2 66Kv Nilkanth S/S. TOTAL Total in Rs. (Figure in words : ) Bidder's Name : Signature : Name : Designation : Bidder's Seal Date : Sign & seal of Bidder 3
Sr. No. Description In Nos. Rate unit Ex Works 1 2 3 4 ANNEXURE A to Bidding schedule for supply prices Name 0f Substation :--------------------- Frei -ght cha rge s Insur ance char ges 5 6 Unit F.O.R. in Rs. (4 + 5+6) 7 8 Excise duty. % as well as amount Rate in % of Ex-Works price 9 Unit E.D. Sale Tax % as well as amount CST = ON (4+9) VAT = ON (4+9) 10 11 Rate in % Amount Rs. CST VAT Total amount Rs. Unit end Cost Price in Rs. (7+9+11) 12 13 Total Amount in Rs FOR COST IN RS. (3 X 7 ) 14 END COST IN RS. (3 X 12 ) Total Material Description & shall be as per supply price schedules I/ We agree to supply the articles noted above at the rates herein tendered by me/ us subject to the condition of tender and supply of the Tender inquiry, which I / We have carefully read and thoroughly understood. I/ We hereby agree to keep this offer open for 180 days after the date of the opening of technical bid of tenders and shall be bound by communication of acceptance dispatched within the prescribed time. Bidder's Name : Signature : Name : Designation : Bidder's seal Date : * Sign & seal of Bidder 4
ANNEXURE B -Bidding schedule for erection & commissioning prices Name of Substation:---------------------- Amount in Rs. SR. NO. Descripti on Unit No./ wt. Particulars Erection/Commis sioning rate per unit (inclusive of Service tax ) Any othe r Tax Unit rate of erection & comm. charges +any other tax Total erection & commissionin g charges on end cost basis ( x Unit rate TOTAL Material Description & shall be as per Erection price schedule. The prices quoted shall be inclusive of service tax. No separate service tax shall be quoted. I/ We agree to execute the articles noted above at the rates herein tendered by me/ us subject to the condition of tender and execute of the Tender inquiry, which I / We have carefully read and thoroughly understood. I/ We hereby agree to keep this offer open for 180 days after the date of the opening of technical bid of tenders and shall be bound by communication of acceptance dispatched within the prescribed time. Bidder's Name : Signature : Name : Designation : Bidder's Seal Date : Sign & seal of Bidder 5
The service tax shall be reimbursed on production of evidence of payment of service tax to appropriate authority by contractor. I/ We agree to execute the articles noted above at the rates herein tendered by me/ us subject to the condition of tender and execute of the Tender inquiry, which I / We have carefully read and thoroughly understood. I/ We hereby agree to keep this offer open for 180 days after the date of the opening of technical bid of tenders and shall be bound by communication of acceptance dispatched within the prescribed time. Bidder's Name : Signature : Name : Designation : Bidder's Seal Date : Sign & seal of Bidder 6
Sr. No. A B i ii Package 1 BOQ for 66 KV Nilkanth (Hybrid switchgear) Sub Station Particulars of Item Supply, Erection Testing & Commissioning of 66kV Hybrid Switchgear Module with structure having 2 Nos. of Disconnectors, 1 no. of SF6 CB, 1 Set of CTs, Local control Centre, Terminal connectors (suitable for 2.5" IPS aluminum tube / ACSR Zebra conductor) connecting to Single Bus system, as per respective technical specifications and relevant special conditions. Sign & seal of Bidder 7 Unit Erection Supply 1) 66kV Hybrid Switchgear Module for Line bay No. 2 2 2) 66kV Hybrid Switchgear Module for Transformer bay (1 Nos Spare Bay) Hybrid Earthing Twin Earthing connection from Hybrid body to structure and from structure to earth mat through risers using GI strip having size of 50x6 mm. (Earth mat will be provided by GETCO). No. 5 5 Earthing connection from Hybrid LCC to structure using single flexible copper cable of 50 sqmm. No. 5 5 C Hybrid Civil work : Design, Supply of materials & construction of RCC Foundation of Hybrid modules including required foundation bolts and materials. i 2 nos foundations for 66kV Line bay 2 nos foundations for 66kV Transformer bay 1 nos foundation for 66 kv Spare Transformer Module D E 1 No. Protection BOQ for 66 KV NILKANTH (HYBRID) Sub Station (for Hybrid Switchgear Package) Set 5 5 Supply, Erection, Testing & Commissioning of Protection equipments and materials as per respective technical specifications and relevant special conditions and suitable for Single Main Bus system on 66kV side Control & Relay Panel for 66kV bays ( Control Voltage - 110V DC ) as per tech specifications & suitable for Hybrid switchgear modules with following break up. 1) Control & Relay Panel for Line No. 2 2 2) Control & Relay Panel for Transformer With Differential Relay No. 3 3 Supply and installation of materials/item for Power Cable and control Cable wiring as per approved wiring schedule. Supply and Laying of 1.1 kv PVC armoured copper/aluminum control/lt power cable in trench including binding/clamping of cable with PVC locable wire tie as per requirement including supply and fixing of identification tags on both ends and at distance of every 100mtr. (Note :- Aluminium cables of size 185 mm 2 & above shall be XLPE type) 1) 2c x 2.5 mm 2, armoured copper control cable Mtr. 750 750 2) 2c x 4 mm 2, armoured copper control cable Mtr. 150 150 3) 4cx2.5 mm 2, armoured copper control cable Mtr. 0 0 3 3
2 2a 3 4) 4c x 4 mm 2, armoured copper control cable Mtr. 400 400 5) 7c x 2.5 mm 2, armoured copper control cable Mtr. 0 0 6) 12c x 2.5 mm 2, armoured copper control cable Mtr. 400 400 7) 12c x 4 mm 2, armoured copper control cable Mtr. 250 250 8) 19c x 2.5 mm 2, armoured copper control cable Mtr. 750 750 9) 27c x 2.5 mm 2, armoured copper control cable Mtr. 750 750 Termination of the control cable at panel / MK box/equipment including PVC binding dressing/shaping drilling of holes in panels for glands nuts for following size. The work also includes Looping in panel and MK box with using crimping type of lugs of suitable size with ferruling with proper size of copper cable wire. The loops should be bunched with using button tape and proper shaping etc. 1) cables from 2 core to 7 core of 2.5 & 4.0 Sq.mm size No. 50 50 2) cables above 7 core No. 75 75 Supply, Erection, Testing and Commissioning of Modular Multidiameter Cable sealing system as per respective technical specification and relevant special conditions wherever the electrical / instrumentation / communication / LT Power cable LS underground and over-ground enter or leave bay kiosks / control room of substations / cable trench / basement. Providing and fixing of GI tray of suitable size with necessary size of bands & joints and top covers for cable protection of LCC as per instruction of Engineer-in-charge. 66 KV Switch Yard Mtr. 15 15 Package-2 BOQ for 66 KV Tragad (Hybrid switchgear) Sub Station Supply, Erection Testing & Commissioning of 66kV Hybrid Switchgear Module with structure having 2 Nos. of Disconnectors, 1 no. of SF6 CB, 1 Set of CTs, Local control A Centre, Terminal connectors (suitable for 2.5" IPS aluminum tube / ACSR Zebra conductor) connecting to Single Bus system, as per respective technical specifications and relevant special conditions. 1) 66kV Hybrid Switchgear Module for Line bay No. 4 4 2) 66kV Hybrid Switchgear Module for Transformer bay (1 Nos Spare Bay) No. 4 4 B Hybrid Earthing Twin Earthing connection from Hybrid body to structure and i from structure to earth mat through risers using GI strip having size of 50x6 mm. (Earth mat will be provided by GETCO). No. 7 7 ii Earthing connection from Hybrid LCC to structure using single flexible copper cable of 50 sqmm. No. 7 7 C Hybrid Civil work : Design, Supply of materials & construction of RCC Foundation of Hybrid modules including required foundation bolts and i materials. 4 nos foundations for 66kV Line bay 3 nos foundations for 66kV Transformer bay 1 nos foundation for 66 kv Spare Transformer Module Set 8 8 Sign & seal of Bidder 8
Protection BOQ for 66 KV TRAGAD (HYBRID) Sub Station (for Hybrid Switchgear Package) Sr. No. D E 1 2 2a Particulars of Item Supply, Erection, Testing & Commissioning of Protection equipments and materials as per respective technical specifications and relevant special conditions and suitable for Single Main Bus system on 66kV side Unit Erection Supply Control & Relay Panel for 66kV bays ( Control Voltage - 110V DC ) as per tech specifications & suitable for Hybrid switchgear modules with following break up. 1) Control & Relay Panel for Line No. 4 4 2) Control & Relay Panel for Transformer With Differential Relay No. 3 3 Supply and installation of materials/item for Power Cable and control Cable wiring as per approved wiring schedule. Supply and Laying of 1.1 kv PVC armoured copper/aluminum control/lt power cable in trench including binding/clamping of cable with PVC locable wire tie as per requirement including supply and fixing of identification tags on both ends and at distance of every 100mtr. (Note :- Aluminium cables of size 185 mm 2 & above shall be XLPE type) 1) 2c x 2.5 mm 2, armoured copper control cable Mtr. 1100 1100 2) 2c x 4 mm 2, armoured copper control cable Mtr. 150 150 3) 4cx2.5 mm 2, armoured copper control cable Mtr. 0 0 4) 4c x 4 mm 2, armoured copper control cable Mtr. 850 850 5) 7c x 2.5 mm 2, armoured copper control cable Mtr. 0 0 6) 12c x 2.5 mm 2, armoured copper control cable Mtr. 550 550 7) 12c x 4 mm 2, armoured copper control cable Mtr. 250 250 8) 19c x 2.5 mm 2, armoured copper control cable Mtr. 1100 1100 9) 27c x 2.5 mm 2, armoured copper control cable Mtr. 1100 1100 Termination of the control cable at panel / MK box/equipment including PVC binding dressing/shaping drilling of holes in panels for glands nuts for following size. The work also includes Looping in panel and MK box with using crimping type of lugs of suitable size with ferruling with proper size of copper cable wire. The loops should be bunched with using button tape and proper shaping etc. 1) cables from 2 core to 7 core of 2.5 & 4.0 Sq.mm size No. 75 75 2) cables above 7 core No. 100 100 Supply, Erection, Testing and Commissioning of Modular Multi-diameter Cable sealing system as per respective technical specification and relevant special conditions wherever the electrical / instrumentation / communication / LT Power cable underground and over-ground enter or LS leave bay kiosks / control room of substations / cable trench / basement. 3 Providing and fixing of GI tray of suitable size with necessary size of bands & joints and top covers for cable protection of LCC as per instruction of Engineer-in-charge. 66 KV Switch Yard Mtr. 15 15 Note: The bidder has to submit separate price bid for 66KV Tragad & 66KV Nilkanth S/S, however bidder can quote for only one package. Sign & seal of Bidder 9