Climate chamber with illumination

Similar documents
Climate chambers with illumination

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating oven with natural convection

Heating oven with mechanical convection

Heating chamber with mechanical convection

Heating oven with mechanical control

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Heating chamber with mechanical convection

Refrigerated incubator with Peltier technology

Safety drying oven with expended temperature range

Safety drying ovens. Advantages: Areas of application: FDL series 115

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

Safety drying ovens with expanded temperature range

geass.com Environmental simulation chambers for cyclic temperature testing MK MKT series Alternating temperature and climate testing

Drying ovens. ED Drying oven with natural convection. Performance features and equipment :

Drying ovens. FD 53 - Drying oven with forced convection. Performance features and equipment :

MK MKF MKT MKFT Environmental simulation chambers

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Environmental simulation chambers MK MKF MKT MKFT

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection

MDL series Safety drying ovens with first class safety features and an expanded temperature range

Dynamic climate chambers. MK MKF MKT MKFT series

FUNCTION LINE HEATING AND DRYING OVENS

GENERAL PURPOSE INCUBATOR

Environmental/Analytical LabCivil Engineering Lab Equipment

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

Flash Point Process Analyzer

Optidew Vision Optical Dew-Point Meter

STABILITY TESTING CLIMATIC CHAMBER

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

Incubators. Incubators

Cooled incubators (ST), laboratory refrigerators

INCUBATORS I PAGE 4-8. COMPRESSOR-COOLED INCUBATORS ICPeco PAGE COMPRESSOR-COOLED INCUBATORS ICP PAGE 19-20

emp. & Humid. Chambers

Cyclic Corrosion Test CORR Series

flowtronic Sensor Series S8005 flowtronic Sensor Series S8005 Product Information Version GREGORY Technology GmbH

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

WR series. WR 200 WR 200 i WR 240 WR 240 i WR 250

Penetration. Test Methods

emp. & Humid. Chambers

GHMsilverline Handheld Instruments

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Nexa 1200 Fuel Cell System

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

-86 0 C FREEZER. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Electronic Flow Monitor for liquids

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Laboratory refrigerators

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

NEW. Large range of models, customizable performance output Flexible equipment options Easy and clear operation. LAUDA Variocool. Circulation chillers

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Refrigerators/Freezers

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

Shaking Incubators & Shakers

CFPP Process Analyzer

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Environmental Chamber

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

EBI 3x0 PDF Data Loggers

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Cyclic Corrosion Chamber C.C.T AUTO Series

Salt Spray Chamber HKT 1000

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Ovens. UL Certified Ovens WON, WOF & WOV models. WiseVen. High-Clean Air Ovens

Vacuum Evaporator with optional separate remote controller with or without shaking feature page 2 page 3 page 3. Incubator with cooling feature

VTZ variable speed Reciprocating compressors

Actuators IC 20, IC 40

Heavy Duty Orbital Shakers

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

Blue e+ chillers with the principle

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

CEAST - HDT & VICAT. Thermal Testing Instruments

Usb data loggers for cold chain monitoring

MOBILE MEASUREMENT TECHNOLOGY

Flow VA 550 / 570. DVGW tested. Flow.

Dissolved Oxygen Measurement System with Air Blast Cleaner

better measurement Simply a question of

LAUDA Variocool. Numerous options, compact design, easy operation

JUMO ecotrans Lf 01/02

Installation & Operation Manual

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Differential Pressure Sensors

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Flexel Drum for LevMixer

Professional thermometer and food oil monitor

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

MESSKO MTraB product line (see application table page 3) MESSKO MTraB connection requirements

HETTICH BENELUX PLANT GROWTH CABINETS. HETTICH BENELUX B.V.

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Transcription:

KBW series (E5.1) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows this climate chamber to create constant lighting and temperature conditions. Advantages: Homogeneous light distribution Natural growth conditions Temperature & light in one unit Areas of application: Cosmetics Industry Plant / Insect Growth Packaging Industry

Customer benefits Features Customer benefits Characteristics APT.line climate technology Same test conditions throughout the chamber interior Independent of specimen size and quantity No drying out of specimens APT.line Constant and gentle circulation of air through large-surface side walls even under a full load Homogeneous climate conditions throughout all specimens Light Cooling system Standard equipment Unit design Accessories and Services Up to 20% greater usable space Light sources adjustable to specimen sizes Same irradiation results throughout the chamber interior Reliable testing independent of ambient conditions No extra costs Chamber is easily moved on casters Minimum space requirements Easy assembly Large chamber interior volume Easy cleaning Complete solution Everything from one source BINDER Service is always nearby Flexible positioning and fully removeable illumination cassettes Excellent light uniformity for all specimens on the entire shelf Different light spectra can be used Powerful compressor cooling system with large power reserves for lighting applications No freezing thanks to double evaporator plate Carefully measured cooling Comprehensive standards Communication interface Access port diameter 30 mm BINDER test certificate Casters Inner glass door and double outer door seal Door heated against condensation ptimal ratio of usable space and footprint Large access area thanks to wide design Chamber interior made out of high-quality stainless steel Closed illumination cassettes No permanent fixtures Comprehensive product portfolio Various options: BINDER Data Logger Kits, access ports in various sizes and positions, control and documentation software APT-CM Years of proven and recognized validation and documentation materials Worldwide service network BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Performance characteristics Electronically controlled APT.line preheating chamber assuring temperature accuracy and reproducible results Temperature range 0 C to 70 C (without illumination) Temperature range 5 C to 60 C (with illumination) 2 variable positioned illumination cassettes with 5 daylight illumination tubes, each, in steps switchable The patented illumination system assures an unique homogeneous light distribution MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections Integrated week program timer with real time function Digital temperature setting with an accuracy of a tenth of a degree Adjustable ramp functions via program editor Adjustable fan speed Elapsed time indicator Access port Ø 30 mm, left side Inner glass door Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm RS 422 interface for communication software APT-CM DataControlSystem Adjustable intervals for printer 2 stainless steel racks BINDER test confirmation BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications KBW 240 (E5.1) Exterior dimensions Heat compensation with illumination Width (mm) 930 Height (incl. casters) (mm) 1460 Depth (incl. door handle, I-triangle, connection 80 mm) (mm) 800 Wall clearance, rear (mm) 100 Wall clearance, side (mm) 100 Heat compensation without illumination Steam space volume (l) 348 Number of doors (ea.) 1 Inner glass door(s) (ea.) 1 Interior dimensions Width (mm) 650 Height (mm) 785 Depth (mm) 485 Interior volume (l) 247 Racks (number standard/max.) 2 / 9 Load per rack (kg) 30 Permitted total load (kg) 100 Weight (empty) (kg) 202 Variable position illumination cassettes 2 Temperature data (without illumination) Temperature range ( C) 0-70 Temperature variation (± K) 0,5 Temperature fluctuation (± K) 0,1 Max. heat compensation up to 40 C (W) 350 Temperature data (with 100 % illumination) Temperature range ( C) 5-60 Temperature variation (± K) 0,5 Temperature fluctuation (± K) 0,1 Max. heat compensation up to 40 C (W) 250 Illumination data (per illumination cassette) Daylight tubes (Lux) / (W/m2) 10.000 / 36 Fluora growth lamps (Lux) / (W/m2) 6.500 / 34 Arabidopsis tubes (Lux) / (W/m2) 10.000 / 40 BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications KBW 240 (E5.1) Electrical data IP protection class acc. to EN 60529 IP 20 Voltage (± 10 %) 50 Hz (V) 230, 1 N ~ Nominal power (kw) 1,4 Energy consumption 1) without illumination at 0 C (W) 360 with illumination at 4 C (W) 520 with illumination at 25 C (W) 495 with illumination at 37 C (W) 525 Noise level (db (A)) 52 1) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time. BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

ptions Variable illumination The illumination selection is based on the application, light spectrum and intensity. For example: FLURA growth fluorescent tubes may be exchanged for daylight fluorescent tubes BINDER Data Logger Kits The new BINDER Data Logger Kits Makes independent recording of temperature and humidity data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount Access port With silicone plugs for introducing external measuring instruments into the chamber, access ports with 30, 50 or 100 mm diameters Analog output Analog output for temperature 4-20 ma with 6-pin DIN socket (output not adjustable) Calibration certificate & validation BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

ptions KBW 240 (E5.1) Access ports with silicone plug 30, 50, 100 mm Securing elements for additional fastening of racks (1 set of 4 pieces) Additional PT 100 temperature sensor, flexibly installed, with external connection, including DIN connector (6-pin) Ethernet interface for communication software APTCM DataControlSystem Factory calibration certificate. Measurement in center of chamber at 37 C or at specified testing temperature Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 C or at specified temperature with measuring protocol and certificate Data Logger Kit T 220: For the continuous temperature recording of -90 C to 220 C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable (RS 232) Rack, stainless steel Shelf, perforated, stainless steel Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces), max. load 70 kg Vibration compatible shelf / platform (positioned at bottom level) to be mounted inside the chamber for shaker / spinner / roller operation. ther positions available on request Temperature safety device, class 3.3 (DIN 12880) with optical alarm Analog temperature output, 4-20 ma, with 6-pin DIN socket (output not adjustable) Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 2 relay outputs via 2 of the programmable controller s controller contacts. utputs can be switched on and off either automatically, or also manually Waterproof interior socket 230 V AC (max. 200 W), IP65 protected, with corresponding plug (IP66 protected) Max. allowed operating temperature 50 C FLURA growth lamps set as replacement for the standard tubes for 230 V Arabidopsis fluorescent tubes set as replacement for the standard tubes for 230 V Replacement set of standard daylight illumination tubes for one illumination cassette Replacement set of FLURA illumination tubes for one illumination cassette Replacement set of Arabidopsis illumination tubes for one illumination cassette Locking door handle with key BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany