Optimal Power Flow Formulation in Market of Retail Wheeling

Similar documents
Complex Power Flow and Loss Calculation for Transmission System Nilam H. Patel 1 A.G.Patel 2 Jay Thakar 3

Available Transfer Capacity with Renewable Energy

TRANSMISSION LOSS MINIMIZATION USING ADVANCED UNIFIED POWER FLOW CONTROLLER (UPFC)

Effect of Load Variation on Available Transfer Capability

EEEE 524/624: Fall 2017 Advances in Power Systems

Comparison of Wheeling Cost using Power Flow Tracing Methods in Deregulated Electric Power Industry.

Management of Congestion in the Deregulated Energy Market

Module 7 : Power System Structures. Lecture 33 : Structure of a Deregulated Industry. Objectives. Overview of A Deregulated Industry

A Novel Distribution System Power Flow Algorithm using Forward Backward Matrix Method

Optimal Power Flow (DC-OPF and AC-OPF)

JCHPS Special Issue 1: February Page 275

A Method for Determining the Generators Share in a Consumer Load

IMPACT OF THYRISTOR CONTROLLED PHASE ANGLE REGULATOR ON POWER FLOW

Pricing Of System Security through Opf and Scopf Methods with N-1 Contingency Criteria in Deregulated Electrcity Market

LOCATIONAL MARGINAL PRICING APPROACH FOR A DEREGULATED ELECTRICITY MARKET

Available Transfer Capability Calculation Using ACPTDF & DCPTDF on IEEE-24 bus System Under Deregulated Environment

Simulation of Security Constraint Optimal Power Flow Using Power World Simulator

Deploying Power Flow Control to Improve the Flexibility of Utilities Subject to Rate Freezes and Other Regulatory Restrictions

EITF Issue 15-A, Application of the Normal Purchases and Normal Sales Scope Exception to Certain Electricity Contracts within Nodal Energy Markets

ECONOMIC EXTENSION OF TRANSMISSION LINE IN DEREGULATED POWER SYSTEM FOR CONGESTION MANAGEMENT Pravin Kumar Address:

VOLTAGE STABILITY CONSTRAINED ATC COMPUTATIONS IN DEREGULATED POWER SYSTEM USING NOVEL TECHNIQUE

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 13 Issue 1 MARCH 2015.

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

Islanding of 24-bus IEEE Reliability Test System

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Islanding of 24-bus IEEE Reliability Test System

Simulation of Voltage Stability Analysis in Induction Machine

A Novel Approach for Optimal Location and Size of Distribution Generation Unit in Radial Distribution Systems Based on Load Centroid Method

CONTINGENCY ANALYSIS AND RANKING ON 400 KV KARNATAKA NETWORK BY USING MIPOWER

VOLTAGE STABILITY IMPROVEMENT IN POWER SYSTEM BY USING STATCOM

1 Benefits of the Minivan

Load Flow Analysis on 400 KV Sub-Station- A Case Study

Power Quality Improvement Using Statcom in Ieee 30 Bus System

Identification of Best Load Flow Calculation Method for IEEE-30 BUS System Using MATLAB

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Computer Aided Transient Stability Analysis

Electric Power Research Institute, USA 2 ABB, USA

CONGESTION MANAGEMENT FOR COMPETITIVE ELECTRICITY MARKETS

Optimal placement of SVCs & IPFCs in an Electrical Power System

OPTIMAL Placement of FACTS Devices by Genetic Algorithm for the Increased Load Ability of a Power System

ECE 740. Optimal Power Flow

POWERWORLD SIMULATOR. University of Texas at Austin By: Mohammad Majidi Feb 2014

Electrical Power Systems

United Power Flow Algorithm for Transmission-Distribution joint system with Distributed Generations

Power System Economics and Market Modeling

Coordinated Charging of Plug-in Hybrid Electric Vehicles to Minimize Distribution System Losses

IEEE SESSION COMPUTER AIDED SMART POWER GRID

OPTIMAL OPERATION OF SMART HOUSE FOR REAL TIME ELECTRICITY MARKET. University of the Ryukyus, Okinawa, Japan

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

Why Japan remains skeptical of restructuring Study of Electricity Market Bidding Characteristics for Modeling Generation Capacity Growth

Solar Project Development in Regulated Markets. Smart and Sustainable Campuses Conference 2017

Application Method Algorithm Genetic Optimal To Reduce Losses In Transmission System

Optimal Placement of Distributed Generation for Voltage Stability Improvement and Loss Reduction in Distribution Network

Fuzzy Based Unified Power Flow Controller to Control Reactive Power and Voltage for a Utility System in India

Cost-Efficiency by Arash Method in DEA

An Approach for Formation of Voltage Control Areas based on Voltage Stability Criterion

ATC Computation with Consideration of N-1 Contingency and Congestion Removal Using FACTS Devices

Predicting Solutions to the Optimal Power Flow Problem

Identification of Source-Sink Connections for Transmission Cost Calculations by. Wan King Him D. Final Report

Island Smart Grid Model in Hawaii Incorporating EVs

PLANNING, ELIGIBILITY FOR CONNECTION AND CONNECTION PROCEDURE IN EMBEDDED GENERATION

Power System Economics and Market Modeling

A Viewpoint on the Decoding of the Quadratic Residue Code of Length 89

OPF for an HVDC feeder solution for railway power supply systems

Design of a Low Voltage DC Microgrid Based on Renewable Energy to be Applied in Communities where Grid Connection is not Available

OPF for an HVDC Feeder Solution for Railway Power Supply Systems

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

DIgSILENT Pacific PowerFactory Technical Seminar

Moment-Based Relaxations of the Optimal Power Flow Problem. Dan Molzahn and Ian Hiskens

Statcom Operation for Wind Power Generator with Improved Transient Stability

The Optimal Location of Interline Power Flow Controller in the Transmission Lines for Reduction Losses using the Particle Swarm Optimization Algorithm

Maintaining Voltage Stability in Power System using FACTS Devices

Overview of ISO New England and the New England Wholesale Power Markets

Computation of Sensitive Node for IEEE- 14 Bus system Subjected to Load Variation

Energy Systems Operational Optimisation. Emmanouil (Manolis) Loukarakis Pierluigi Mancarella

TABLE OF CONTENTS. Table of contents. Page ABSTRACT ACKNOWLEDGEMENTS TABLE OF TABLES TABLE OF FIGURES

Master Slave Control Of Interline Power Flow Controller Using PSO Technique

Microgrids Optimal Power Flow through centralized and distributed algorithms

Phase Shifting Autotransformer, Transmission Switching and Battery Energy Storage Systems to Ensure N-1 Criterion of Stability

Vehicle Dynamics and Drive Control for Adaptive Cruise Vehicles

Characterization of Voltage Rise Issue due to Distributed Solar PV Penetration

POWER FLOW SIMULATION AND ANALYSIS

Industry Results Transmission Systems

MthSc 810 Mathematical Programming Case Study: The Global Oil Company

Implementation of FC-TCR for Reactive Power Control

ENERGY MANAGEMENT 4/22/2014. What are your approximate yearly energy costs? (Electricity, natural gas, etc.)

An Architectural View of Emerging Changes to the Grid

IMPROVEMENT OF LOADABILITY IN DISTRIBUTION SYSTEM USING GENETIC ALGORITHM

EMS of Electric Vehicles using LQG Optimal Control

The Effect Of Distributed Generation On Voltage Profile and Electrical Power Losses Muhammad Waqas 1, Zmarrak Wali Khan 2

INCREASING electrical network interconnection is

Cyber-Physical Systems for Smart Grid

INDUCTION motors are widely used in various industries

Forecasting of Utility Cost in a Deregulated Electricity Market by Using Locational Marginal Pricing

Adaptive Power Flow Method for Distribution Systems With Dispersed Generation

REGIONAL TRANSMISSION ORGANIZATIONS / INDEPENDENT SYSTEM OPERATORS AND THE ENERGY IMBALANCE MARKET: AN OVERVIEW OF THE PICTURE IN THE WEST

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

CHAPTER I INTRODUCTION

INTELLIGENT DC MICROGRID WITH SMART GRID COMMUNICATIONS: CONTROL STRATEGY CONSIDERATION AND DESIGN

Power Consump-on Management and Control for Peak Load Reduc-on in Smart Grids Using UPFC

Transcription:

Optimal Power Flow Formulation in Market of Retail Wheeling Taiyou Yong, Student Member, IEEE Robert Lasseter, Fellow, IEEE Department of Electrical and Computer Engineering, University of Wisconsin at Madison, Madison, Wisconsin, USA Abstract: Power system deregulation along with retail wheeling was proposed in legislation for the future power system operation. Retail wheeling implies customers have more choices. One important option is the power supplier providing cheaper power. In this paper we introduce new concepts of generation sets and load sets to model the behavior of power supply and load distribution in the new retail wheeling market. Formation of optimal power flow (OPF) problem, in which the public interests are maximized, is demonstrated.. IEEE-14 bus system is used as an example. Key words: Power System Deregulation, Retail Wheeling, Optimal Power Flow, Generation and Load Shifting 1. Introduction Electric power system deregulation is underway in the US. The heart of deregulation is retail wheeling. Retail wheeling will create an open market to encourage vigorous and fair competition in electric supply. Past power system structures are vertical. One utility controls the power generation, transmission and distribution in an area. The rate of electricity is regulated. The market is monopoly. Retail wheeling allows customers to choose power suppliers. The utilities have to provide better services and cheaper power to attract customers. The deregulation has already allowed free access to the generation market. The power suppliers are the agencies who sell power to customers. They may not produce power, but they buy shares from generation units. Retail wheeling may allow distribution agencies to enter the distribution market. They represent a group of customers and buy distribution right to acquire power from transmission system. This restructuring of power system challenges the old concepts of power system analysis. Optimal power flow is an optimizing tool for power system planning, energy management etc. Use of the optimal power flow is becoming more important in the deregulated power industry to deploy the resources optimally. In the past time, researchers focused on how to formulate some practical constraints, such as bus voltage range, generation limits, line transfer capability, contingency constraints, environment concerns etc. and how to solve the optimal power flow problem efficiently. Techniques such as Newton method, sequential linear and quadratic programming method, PQ de-coupling method etc [1,2] are used. However some new concerns on optimal power flow arise in the retail wheeling market. In the deregulated power system, Suppliers and Customers exchange power in the energy market. The price of power is determined in the market. The Independent System Operators (ISO) will manage the transmission system operation to ensure completion of the business transactions. Public interest is the objective of the ISO. In this paper, we introduce some new concepts in the formulation of optimal power flow to meet the new environment. A simple IEEE-14 bus system is used to establish the new optimal power flow problem. 2. Description of new concepts Power systems are restructuring to create a more competitive power market. Power systems include two interactive parts, physical transmission system and the power market. Power suppliers and customers are the basic elements in the power market. Power suppliers will sell power to customers through physical transmission system. In the future, the power system structure can be described in the Fig 1. It s possible for power suppliers to be different from the power producers. They make their profits by buying power from the producers, such as hydro power plants, nuclear power plants etc and selling power to consumers. The suppliers have contracts with customers promising the power supply. Here we define a generation set to model the relationship between power suppliers and power generation. Definition of generation set: Generation set is a group of generators where the suppliers can obtain the generation.

ISO Management Power Transmission Network Generation Power Suppliers Order Load Power Distributors Power Customers Fig. 1 Restructured electric power system Using this definition, it s easy to include the power plants which are regulated by states, such as nuclear power plants, large hydro power plants, along with small power plants. Retail wheeling would allow end-use electricity consumers, individually or in aggregate (together with other consumers), to choose among different energy suppliers and place a demand order. This could include terms and condition as quantities, times, prices, and other factors. The power distributors don t control the power level. They maintained the distribution system to ensure the load flow from the transmission system to customers. The distribution systems absorb the power from one or more buses of the transmission system. The load at transmission system may shift between a group of load buses (physically power substations). We can call the group of buses where the load shifts as a load set. Typically the geographical range of loads is limited. The load can only shift among buses in the neighborhood. The load set can also be called as neighborhood set of load. Definition of load set: Load set is a group of load buses with shifting demand. The concept of load set can model the aggregate consumers, or some large electricity consumers, such as large manufacturers. All the transactions of power supply contracts have to be completed through the transmission system. At the system level, public interests concerns, both technically and economically are dominated. Technical aspects, power flow must be satisfied. Electricity must be produced at the instant it is to be used. Large quantities of electric energy cannot be economically stored. Reliability in the supply of electricity is crucial to many applications, and absolutely essential to others. Any reduction in system reliability must be weighed against the potential damage to our economy, our standard of living, and our national security. The transmission system must be maintained at a safe level. Independent System Operator will manage the transmission system in the public interests. Once the new concepts are introduced, some concerns are raised. The loads at transmission system buses are not constant. But the load demand of customers is a fixed value over a period. This constraint, Σ j L ij = L i where L ij = s ij L i ; i: index of load, j: index of elements in the load set of load i; s ij is the share of loads at bus j, And Σ i Σ j L ij = D. D is the total consumer demand, which is equal to the load absorbed by distributors from load buses. The power injection of generator buses to the transmission system is still constrained by the possible output range of generators. But the price of power at each power plant may be different among shares of suppliers. The summation of shares of different suppliers must be in the range of generator output. Σ j G ij = G i, where G ij = h ij G i; i: index of power suppliers, j: index of generators where power suppliers can obtain power to inject into transmission system. h ij is the generator j s shares held by supplier i. The generated power must be equal to the supply requirement Σ i Σ j G ij = S, where S means the total power supply. Market clearing (electricity must be consumed instantly) implies that total supply must be equal to the total load demand S=D. The system loss is compensated by some physical swing buses which maintain the system frequency. The price of power is determined in the market. 3. New Formulation of OPF Retail wheeling causes many complex implications for the existing interconnected transmission and distribution systems in terms of reliability, quality of service, and responsibility for restructured services. Moreover, this transaction has significant financial and implications for electric providers, shareholders, consumers, local units of government, and states. For current systems, important economic benefits are being realized through the coordinated planning and operation of the highly integrated electric generation and transmission systems. These benefits are the result of reduced generation capacity margin requirements and the ability to schedule generation on a lowest incremental cost basis over broad geographical areas. The in the old OPF formulation, the production cost is the objective to minimize, and at the same time, some constraints, including entire power flow equations, generation

limits, voltage ranges and line transfer capability etc., has to be satisfied. The production cost typically is considered as quadratic functions or as a piecewise linear approximation. For a quadratic cost function, the OPF problem we can formulate as Min Cost=Σ(α i *Pg i 2 +βi *Pg i +γ i ) i: index of generators, α i, β i, γ i are the coefficients of quadratic production cost functions. f(pg,qg,v, δ) = 0 Line(Pg,Qg,V, δ) Line max V min V V max Real Power Output Range of Each Unit Pg min Pg Pg max Reactive Power Output Range OF Each Unit Qg min Qg Qg max Other constraints, such as contingency can be added. As discussed in the previous section, we need to reconsider the objective to achieve and the constraints applied to the supply side and demand side. ISOs have to manage the transmission system to benefit all the consumers with considering the system safety. The objective is to maximize the public interests, i.e. to minimize the total transmission loss. The other objective fun can be set to maximize the public interests, such as maximize the social welfare. In this paper, to simplify the formulation, we take the cost minimization as objective function. Generally the constraints of optimal power flow still include the entire AC power flow, generation output range, bus voltage limits, transmission line transfer capabilities. Additional constraints related to the retail wheeling need to be added. For a system with N buses, L lines, J generators, K loads and an associated power market with I suppliers, M customers, mathematically we formulated the OPF in market of retail wheeling as, Min Loss=Σ l P l (S, D, s, h,v, δ) P l is the line power load in two directions. f(s, D, s, h,v, δ) = 0, f is a 2Nx1 vector which contains the real power and reactive power balances at N buses transmission system. Line(S, D, s, h,v, δ) Line max, Line is a 2Lx1 vector, which contains the magnitude of 2-direction flow in all the transmission lines. V min V V max Power Output Range of Each Generation Unit G jmin Σ i G ij G jmax, G ij 0. G ij is the power generated by generator j for supplier i,. i: index of Suppliers, j: index of generators. Load Set Constraints real(σ k L km = L m ), L km = s km L m Σ k s jk =1, m: index of customers, k: index of buses in load set of customer m. Generation Set Constraints real(σ j G ij = G i ), G ij = h ij G i Σ j h ij =1, i: index of suppliers, j: index of generators in generator set of supplier i Elements in Shares s and h are between 0 and 1. 1 s km 0, 1 h ij 0, In the formulation, S is a vector representing all the suppliers power injection through generation sets. D is a vector representing all customers demand absorbed from load set. s and h are the shares of generation of suppliers and shares of load of customers. V and δ are Nx1 vectors, representing the magnitude and angle of each bus voltage. And the other constraints, such as contingency constraints can also be formulated with variables {S, D, s, h, V, δ}. Those intermediate buses, where there is no supply and demand, are still treated as constant. In the new formulation, the loads absorbed from the transmission system buses are not constants, but variables constrained by load sets, which define the distribution choices of customers. In the power supply side, the power output is not only limited by generator ratings, but also constrained by the suppliers choices. This models the free access to generation markets and transmission systems. 4. Sample system formulation Using the proposed formulation, we can create a retail wheeling system. IEEE-14 bus system is used as the base

transmission system. The topology of IEEE-14 bus system is shown in Fig2. 1 2 3 5 4 7 8 6 11 10 14 12 9 13 Fig.2 IEEE-14 bus system This is a system with 14 buses, 20 lines and 5 generators {1, 2, 3, 6, 8}, and 11 load substations {2, 3, 4, 5, 6, 9, 10, 11, 12, 13, 14}, one intermediate bus {7}. Assume there are 2 suppliers {S1, S2} and 4 customers {D1, D2, D3, D4} in the energy market of this small system. Suppose the generation sets of suppliers are defined in Table 1. Load sets of customers are defined in Table 2. Supplier Generator Set S1 1, 2, 3 S2 3, 6, 8 Table 1. Generator Set Definition The overlap over generator at bus 3 means both suppliers S1 and S2 buy inject power to transmission system through generator at bus 3. Customer Load Set D1 2, 3 D2 4, 5, 6 D3 6, 11, 12, 13 D4 4, 9, 10, 14 Table 1. Load Set Definition There is no power supply and demand at bus 7. The meaning of load set is, for example, D1 takes power from bus 2 and 3. The overlap of load set for D2 and d3 indicates both D2 and D3 may absorb power from bus 6. Now the formulation of optimal power flow can be written as, Min Loss=Σ l P l (S, D, s, h,v, δ) f(s, D, s, h,v, δ) = 0. f is 28x1 function Line(S, D, s, h,v, δ) Line max Line is 40x1 function V min V V max V is 14x1 voltage magnitude Power Output Range of Each Generation Unit G jmin Σ i G ij G jmax, i:1,2, j: index of generators {1, 2, 3, 6, 8} Load Set Constraints Σ m s km =1, m:1,2,3,4, k index of elements in load set of m. Generation Set Constraints, i:1, 2, j: index of elements in generation set of supplier i. Elements in Shares s and h are between 0 and 1. 1 s km 0, 1 h ij 0, Intuitively the flexibility of load and generation in the transmission system actually optimize the power delivery and increase the system marginal power range. Load flexibility releases the stress of high load buses and transmission lines. The voltage on high load buses will increase due to some load shifting. 5. Conclusion Optimal power flow is formulated for competitive retail wheeling markets. With understanding of both technical and economic concerns, two important concepts of load sets and generation sets are presented. Under this assumption, optimal power flow is applied to maximize the public interests (e.g. minimize the transmission system loss). The solution of the proposed optimal power flow optimizes the load flow of transmission system by shifting the load from heavily loaded buses to the lightly loaded buses. References [1] M. Huneanult, F.D. Galiana, A Survey of the Optimal Power Flow Literature, IEEE Trans. On Power System, Vol.6, No. 2, May 1992 [2] J.A. Momoh etc, Challenges to Optimal power flow, IEEE Trans. On Power System, Vol. 12, No. 1, Feb,1997 [3] Hal R. Varian, Microeconomic Analysis, Third edition,1993 About Authors:

Taiyou Yong, (B.S. 91, M.S. 95), He is a PH.D candidate in University of Wisconsin and doing research on optimal power flow in deregulated environment, such as OPF in retail wheeling market, sparse techniques application. His interests also include power system analysis, control, and power electronics application. Robert H. Lasseter (F 92) received the PH.D in physics at the University of Pennsylvania in 1971. He was a consultant Engineer at General Electric Co. until he joined the University of Wisconsin-madison in 1980.