DIAPHRAGM PUMPS: Instruction Manual

Similar documents
HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

DP-139 PUMP DIMENSIONS

Electric Pressure Washer

Mod: KLD6-12/35XLAS-N

Owners Manual: - Pumps

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual

BELT CONVEYOR CB/M5 Series

1100W PORTABLE GENERATOR

Pump Operating and Maintenance Manual - Models

MODEL: ATV Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Air Compressor. Operating & Maintenance Instructions 1110 ENGINE DRIVEN - 1 -

SAFETY AND OPERATING MANUAL

3-POINT SPRAYERS. Operation, Service & Parts Manual For G50E. FORM: G50EBook.QXD

Maintenance Instructions for All Models

SUBMERSIBLE WATER PUMP

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

INSTRUCTIONS FOR: BROADCAST / SPOT SPRAYERS. MODEL No's: SS60, SS98 1. SAFETY INSTRUCTIONS 2. INTRODUCTION

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

1200W INVERTER GENERATOR

the heavy duty knapsack sprayer product manual 16 litre model

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

OWNERS MANUAL ECODIVER

BELT CONVEYOR PNL/4 Series User and maintenance manual

WORKHORSE. Assembly / Operation Instructions / Parts

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

OPERATION & MAINTENANCE INSTRUCTIONS

POND PUMP Model Nos:SPP3 & SPP6 0200

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

SUBMERSIBLE WATER PUMPS

PNEUMATIC PUMP Series

F 167/94 07/ GM-

Starting up hydraulic systems

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Operating and Maintenance Manual

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

ENGINE DRIVEN 3 FULL TRASH PUMP

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

GRUNDFOS ALLDOS INSTRUCTIONS. DMB dosing pump. Installation and operating instructions (basic version)

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

PETROL DRIVEN POWER WASHER

OPERATION & MAINTENANCE INSTRUCTIONS

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Model No. LG27-3PT 25 Gallon Sprayer GENERAL INFORMATION

original operating manual Operating manual Translation of the Item-No.: ,

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

MODEL NO. LG Volt Lawn & Garden Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

MATERIAL SAFETY DATA SHEET Page 1 of 5 MSDS#: BA

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

Operations and Parts Manual

Owner's Manual. Model: LS-PCO-100-GEM ( ) (100 Gallon Skid-Mounted High Pressure Sprayer) Technical Specifications. General Information

Broadcast/ Spot Sprayer

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

SUBMERSIBLE DIRTY WATER PUMP

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

DulcoFlex Peristaltic Pump: DFB13B

KNAPSACK ELECTRIC SPRAYER

Water pump Owner's Manual

Engine oil. Introduction. Warning and indicator lights WARNING

Assembly and Maintenance Manual Type ASNU

VT Oil-Free Range Operators Handbook

Bertolini Sprayer Operator s Manual

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

SUBMERSIBLE PUMP HSE RANGE

MODEL NUMBER: BD-132 USER GUIDE

US - UP2/OIL 12V US - UP2/OIL 24V

720W PORTABLE GENERATOR

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

SELF PRIMING CHEMICAL SERVICE PUMPS

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

BELT CONVEYOR CBD/8 Series

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

Hydraulic Immediate Need Power Pack

Medium and high pressure pumps

Geo-Prime Tank. Table of Contents. Installation, Operation & Maintenance Instructions AFCG1PT Revision: 7/3/14. Replacing a Pump 12

Installation, Operation, Repair and Parts Manual

DP DIAPHRAGM PUMP Parts & Instruction Manual

The MCS III system can only be assembled on Nolan helmets pre-set for N-Com.

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

C3 Operating Instructions

MATERIAL SAFETY DATA SHEET

TBE-700. Operation, Safety and Maintenance Manual. Stainless Steel Weld Cleaning System. Ensitech Pty Ltd

Assembly and Operating Instructions

Manual for all Rittenhouse Skid Mount & Trailer Sprayers

MODEL NUMBER: BD-116C USER GUIDE

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Plunger Heads Use and Maintenance Manual

Hydraulic PTO Flow Device

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

Transcription:

INTRODUCTION DIAPHRAGM PUMPS: Instruction Manual Congratulations for choosing a product Imovilli Pompe, the result of a careful manufacturing process supported by over fifty years of specific experience in the agricultural spraying industry. Before leaving the works each product undergoes strict control tests to guarantee its performance and quality. Before putting it to work you should read this use and maintenance manual, which contains the basic instructions for its correct installation and use in safe working conditions. In this manual you can also find useful suggestions for the care and maintenance of the pump, which will help you to maintain its functional characteristics. This use and maintenance manual is an integral part of the pump and must be made available to the end user, who should read the same carefully before starting the pump. If the pump is installed in a machine or a system, the manufacturer of the same must take care that the essential information contained in this booklet is transmitted to the end user. After reading this manual, keep it at hand in a safe place for future reference. PRESENTATION IMOVILLI POMPE piston diaphragm pumps are of the semi-hydraulic type and are made for: agricultural crop protection spraying, weeding, disinfecting, pressure washing. The pumps must work with liquid at ambient temperature, max. 50 C, and are not recommended for continuous duty applications. All the pumps are supplied complete with an identification label, showing the main pump characteristics, where: Q = delivery; P = pressure; RPM = revolutions per minute. INTRODUCTION: Imovilli Pompe srl is not responsible for damage caused by: the non-observance of the contents of this instruction manual (or of the use and maintenance manual of the machine or system where the pump is installed) use of the pump different from that explicitly indicated in the paragraph ENVISAGED USE any use in contrast with the existing regulations on safety and the prevention of accidents at work incorrect installation lack of maintenance modifications or interventions non-authorized by the manufacturer use of non-original spare parts or parts unsuitable for the specific pump model use of non-original or unsuitable accessories for the specific pump model repairs carried out by personnel not qualified The most important instructions and rules about safety are marked with the international symbol meaning warning or caution. MOVING & FIXING

To move pumps and pump sets that weigh more than 25.00 Kg it is suggested the use of appropriate lifting gears with fabric belts securely hooked for a strong and safe hold that allows a well balanced lift of the pump. Always fix the pump firmly to the frame of the machine using the appropriate holes on the base. Periodically check for tightness the bolts fixing the pump. SAFETY DEVICES The pump, or the machine where the same is contained, cannot be put into service if the safety devices listed below have not been installed previously. 1. Safety valve Optional extra. This is a valve suitably calibrated to discharge excess in pressure caused by a possible malfunction in the system. 2. Protective cover for the pump shaft and accessories Available as an accessory, these are devices that stop the operator or others from accidentally touching the rotating components of the pump. The installer must protect all of the rotating parts and guarantee the effectiveness of the protective covers on all the optional devices (Pulleys, belts, joints, anti-rotation devices, etc.) 3. Valve for limiting and adjusting the pressure Some models are equipped with a valve that permits to regulate the working pressure. The same valve is available as an accessory for other models. It also lets the excess liquid flow through the By-Pass and, through taps, to direct the fluid under pressure to the utilities. The valve and taps are usually called the Control Unit. If the pump is supplied without the regulating valve or control unit from IMOVILLI POMPE, at least one adjustment valve must be installed on the delivery line suitable for discharging the total capacity of the pump. We also recommend installing a safety valve on the delivery line that discharges into the tank, the operational pressure of which should be 10% higher than the maximum pressure envisaged for the pump, or for the plant, if lower than that of the pump. ENVISAGED USE The pump is only intended for the following uses: Treatments for protection of cultivations in the agricultural sector and gardening Pumping detergents and colors in water-solutions Pumping water NOT fit for consumption It is absolutely forbidden to use the pump for the following purposes: Pumping drinking water Pumping liquids for alimentary use Pumping liquids or others substances for feeding or watering animals Pumping combustibles and flammable liquids (Petrol, etc.) Pumping liquefied gas (LPG, etc.) Pumping liquids with a viscosity or density higher than that of water

Pumping seawater or water with a high salt concentration Pumping solvents and thinners of any kind Pumping liquids with temperatures over 40 C and below 5 C Washing persons or animals Any other use different to that indicated as the sole envisaged use of the pump, is considered improper use. Imovilli Pompe is NOT responsible for any damage caused by improper, or erroneous use. BEFORE STARTING 1) Make sure that the oil level is visible between the min. and max. Levels indicated on the oil tank or clearly visible at the level caps (depending on the different pump models). If necessary add SAE 40 anti-foam oil. 2) Check constantly the tightness and conditions of the hoses and plumbing, particularly the ones on the pressurized side of the pump. 3) For the pump models equipped with the pulsation dampener, check and adjust the pressure according to the different spraying pressures, as suggested in the enclosed table. WARNING: NEVER dismantle the pulsation dampener tank without having first drained all of the air inside. HOSE LINES AND PLUMBINGS Always use hoses having an internal diameter corresponding to the size of the hose tails supplied as standard on the pumps. - For the SUCTION LINE we suggest the use of reinforced rubber hose or plastic hose reinforced with metal spiral. AVOID using plastic hoses with nylon spiral reinforcement. To avoid the intake of air, we recommend keeping the suction hose in the tank away from the discharge one; the latter should be suitably fixed in order to prevent accidental spillage the liquid to be pumped. Seal the joints between hoses and hose tails with silicon sealant, fix properly with hose clamps and tighten the fittings on the pumps. AVOID reducing or restricting the diameter of the hose. NEVER use the pump without a suction filter. The filter should be dimensioned to handle twice the pump maximum capacity and equipped with a strainer with a free orifice of max 0,75 mm. Always inspect the filter conditions before spraying. It should be clean and free of deposit. - For the PRESSURE LINE use good quality hoses, adequate to the max. Spraying pressure of the pump. Always use hoses with the max. Allowed spraying pressure clearly marked. - For the BY-PASS/DISCHARGE LINE it is recommended a hose suitable for at least 10-bar pressure. STARTING AND USE NEVER start the pump unless all the safety precautions prescribed in the chapter INSTALLATION has been met. The pump cannot be put into service if the machine in which it is installed does not conform to the safety requisites established by European directives. This is guaranteed by the presence on the same of the CE mark and the Declaration of Conformity supplied by the manufacturer of the machine. Run the pump at the RPM allowed, with the pressure regulating valve open (pressure = 0) for a few moments. When the liquid flows regularly from the discharge, adjust to the required spraying pressure. The max pressure allowed is the one marked on the pump identification label and on the pump data sheet enclosed. smaller pumps, without a pressure gauge, the max. Pressure is achieved by turning the pressure-regulating knob until it reaches a stop. NEVER start the pump if you have reason to believe that the liquid inside the pump might be frozen: doing so can severely damage the pump!

WARNING 1) NEVER exceed the max. Permissible suction lift (see enclosed details). 2) ALWAYS run the pump within the max. Rotation speeds allowed. 3) NEVER exceed the max. Pressure allowed. 4) NEVER stop the pump in pressure. 5) NEVER start the pump in pressure. 6) NEVER use the pump for different applications from the ones for which it has been designed and indicated in the paragraph ENVISAGED USE 7) NEVER direct the spray liquid on persons or animals: remember you are using potentially dangerous products. 8) ALWAYS wear protective clothing (gloves, goggles, masks, respirators, etc.) and follow the instructions given by the manufacturer of the active ingredients you are using. 9) NEVER discharge the residuals of the chemical mixture in the environment, keep them in a container and dispose of them according to the environmental regulations. N.B.: the non-observance of points 1 to 6 makes the guarantees void. AFTER USE 1) When finished spraying, with the pressure relief valve open (pressure = 0), circulate clean water for a few minutes, for rinsing the system, then drain it. 2) For complete drainage, let the pump run dry for 10/15 seconds. For storing periods longer than 3 or 4 months, after rinsing with clean water, circulate in the pump a mixture of water and 30% antifreeze, without draining it: by doing so, it will be protected from possible oxidation and frost. At the end of every spraying season, check the conditions of valves and diaphragms: this will help to prevent inconveniences the next season. Trained personnel should make these last operations only. PUMP SETS Pump sets are equipped with a label with the most important characteristics (see pump instructions). The pump set model corresponds to the pump model used. The instruction manual of the motor is supplied along with the pump and this should also be read and kept in a safe place. ELECTRICAL MOTOR PUMPS 1) Installation: see pump instructions. It is normally advised to fix the pump set on shock absorbers. 2) Hose lines plumbing: see pump instructions. Always position the suction hose away from the bypass line to avoid water turbulence and suction of air bubbles; all hoses should be fixed to prevent accidental spilling of chemicals outside the tank. 3) Starting: Before starting the equipment, make sure that the voltage of the line is the Same as the one showed on the motor label a) Pump set equipped with switch, cable and plug: make sure that the switch is in the OFF position 0, that all the hose lines are properly connected and the adjustment valve of the pump is open (pressure = 0). Insert the plug in the socket and turn the switch to the ON position I, then follow the instructions for STARTING and USING the pump. To stop, after having released the pressure in the pump, turn the switch to the STOP position 0.

b) Models WITHOUT switch, cable and plug: in the case of motor-driven pumps supplied without these accessories or three-phase motor-driven pumps, we recommend having qualified personnel make the electrical connections, as requested by the law. The electrical connections must be made according to the diagram that can be found inside the terminal board. The earth connection is obligatory by law; the installer must make this connection using the proper terminal marked by the international earth symbol and a green-yellow cable. We recommend installing a main switch on the power line with a contactor that prevents accidental restarting, as well as a thermal-magnetic cutout. Before starting, carry out the same controls indicated above at point a). For starting, follow the instructions provided for STARTING and USING the pump. WARNING a) NEVER move the motor pump with the power cable connected to the power socket. b) ALWAYS in the event of a blackout while using the pump, drain the pressure and turn the switch OFF into position 0 : this will prevent the accidental starting of the pump when the power returns. c) NEVER direct the spray of water to the motor. d) AVOID installing the pump set in environments with high humidity (greenhouses, etc.). e) ALWAYS disconnect the motor from the power line before any intervention. PUMP SETS with INTERNAL COMBUSTION ENGINE 1) Installation: see electric motor pump set. 2) Hose lines- Plumbing: see electric motor pump set. 3) Starting: follow carefully the instructions given for the pump and the engine in their respective use and instructions manuals. CAUTION a) NEVER move the pump set with the engine running. b) NEVER TOUCH the hot parts of the engine: cylinder, head, exhaust, etc. These, even if protected, can cause heat burns. c) NEVER operate the pump set in closed or non-ventilated areas. The internal combustion engines produce carbon monoxide, an odorless gas LETHAL TO HUMANS AND ANIMALS. TROUBLE SHOOTING 1) The pump doesn t prime - intake of air: check the suction line and the gasket of the elbow hose tail. Check the suction filter for possible clogging. 2) Irregular pumping - check valves clogged or worn, intake of air: inspect and change the check valves, check the suction line. 3) Unstable pressure or reduction in pressure: check valves clogged or worn, pressure regulating valve worn, intake of air inspect and change if needed, check the suction line. 4) Pump outlet flow is irregular inspect for air leaks of the suction line, check the prescribed pressure in the pressure dampener. 5) Oil overflow from the oil tank: too much oil in the tank if the oil is whitish or thick and mixed with water, there is a diaphragm failure: if this is the case, stop the pump immediately; have the pump serviced at an IMOVILLI POMPE service centre by trained personnel.

WARNING: a continuous and repeated drop in the level of the oil, even without evidence of leaks, can also indicate the failure of one or more diaphragms. In case proceed as indicated above. LIMITED WARRANTY AND RETURN PROCEDURES The pump is guaranteed for 12 month from the date of delivery. The warranty is limited to the repair or substitution of those parts only that will be recognized defective in material or workmanship by IMOVILLI POMPE authorized personnel. Do not return material to factory unless previously authorized by personnel in charge. The defective parts, supposedly under warranty, should be returned to IMOVILLI POMPE warehouse free of all transport costs. The cost of labor for the work done by the customer or by third parties on behalf of the same is not covered by the guarantee. In no case whatsoever can Imovilli Pompe be held to pay any compensation for damage caused by the use and/or partial or total malfunction of the pump. The guarantee is void in the case of: lack of maintenance, incorrect installation, use of the pump in applications not envisaged in the paragraph envisaged use of the present manual (unless authorized in writing by our qualified personnel), operating outside the allowed limits, tampering by third parties or in the case the use of non-original IMOVILLI accessories or spare parts. Important: If you intend returning material to Imovilli Pompe for replacement or repair, before doing so make sure you have obtained permission from the authorized personnel of Imovilli Pompe. Material returned without prior agreement may be refused. All of the pumps or other components must be carefully flushed cleaned of any chemical residues before shipping in order to protect the environment and the personnel handling it from the risk of contamination with fluids of unknown nature. Material not cleaned properly will not be repaired or will be cleaned at the customer s expense before being repaired. This manual cannot cover all of the situations that may arise during the installation and use of the product. It is solely intended to provide essential information relevant to the safety of the installer and of the user. When in doubt, or needing further explanations, please contact us at the following numbers: PHONE: +39 0522 516595 FAX: +39 0522 514735 Or e-mail to: service@imovillipompe.it