Motor driven diaphragm metering pump P D S V N PUMP HEAD MATERIAL. O RING V FKM B D Dutral LUBRICANT TYPE

Similar documents
PRIUS Motor driven diaphragm metering pump

PRIUS D Motor driven diaphragm metering pump

PRIUS D MF AP. Multi-Function motor driven diaphragm metering pump P D M F K V N PUMP HEAD MATERIAL PVDF SS

PRIUS D OPERATING MANUAL MOTOR DRIVEN DIAPHRAGM METERING PUMP SPRING RETURN MECHANISM PVDF PUMP HEAD PP PUMP HEAD SS PUMP HEAD

HL - MHL SPA SOCIETÀ ITALIANA TRASMISSIONI INDUSTRIALI. INSTALLATION, OPERATION and MAINTENANCE MANUAL

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES HT 14 / A / 103 / 0309 / E

USE AND MAINTENANCE BOOKLET DIAPHRAGM PUMP SERIES. SuperMicroLib-2. Pag. 1 a 7

USE AND MAINTENANCE BOOKLET DIAPHRAGM PUMP LIBELLULA 1/4"

SERIES R - MD MOR & GOR

Operating Instructions

Your Partner in Solutions 24/7. EMAW Worm Gearboxes. Tel: Fax: Web:

Operating, lubrication and maintenance instructions for gearboxes and motors

Chemical dosing and control equipments

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1

Service instructions. Table of contents. DMX and DMH

Planetary Gearboxes. cat planetarios 200 pags 2008.in1 1 31/03/ :49:57

CHC SERIES HELICAL GEAR UNITS

NMRV - MCV - NRV NMRV+NMRV PC+NMRV

7.3 Drive Chain Q

Ex Pressostat EXPK 944/947/953. Applications. Features

RAINTIGHT ENCLOSURE. mecair CSN

CHO HELICAL-HYPOID GEAR UNITS

ATTENTION: Industrial machinery for professional use. These instructions are for qualified personnel USE AND MAINTENANCE MANUAL

CYLINDRICAL CAM INDEXING ROTARY TABLES IR TABLES HEAVY SERIES IR IR IR 2001 COLOMBO FILIPPETTI SPA

GEAR BOXES AND MOTORS

DOCUMENTATION - INSTALLATION _ MAINTENANCE

W SERIES TECHNICAL CATALOGUE

Floodlight LED Series 6125

314 ORDINARY MAINTENANCE MANUAL FOR. PGA series VERTICAL MOUNTING POSITION. Release A02/15

INSTRUCTIONS FOR USE FACE GEARBOXES

CUT CAM TOOL CHANGERS CUT31 - CUT41 - CUT51

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application

USO E MANUTENZIONE USE AND MAINTENANCE EMPLOI ET ENTRETIEN GEBRAUCH UND WARTUNG USO Y MANTENIMIENTO I GB F D E G25. roteritalia

Admiss. counterpressure. Admiss. pressure at pump inlet 115 S

HSERIES. Helical geared motors

VR Version. VSX (Atex) Version

VALVES WITH SA ELECTRIC ACTUATOR

Planning Section. Environmental conditions. Different power supply. Industrial solutions

VALVES WITH NA ELECTRIC ACTUATOR

Certified Quality System UNI EN ISO 9001 : 2008 SERVICE MANUAL PGRF series Release A10/14

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type)

Centrifugal medium-pressure fans fitted with multi-blade

KAVITSU Excellence in Gear Technology. The compact And Efficient

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

5 Gear units, types of installation, lubricant quantities. 5.1 Standard fitting positions/ types of installation for Bauer geared motors

Section 3.1. Machine Maintenance - Machine Maintenance Information. Important Preventive Maintenance Information: Maintenance Charts & Diagrams:

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Pro M i n e nt Sigma/ 2 Diaphragm Meter i ng Pu mps

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

motor driven metering pumps

Explosion and flame-proof cast iron electric motors

Admiss. counterpressure. stroke

DDA AR-PVC/V/C with access.

motor driven metering pumps

EX-D ENCLOSURES AND DISTRIBUTIONS

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Versions. f.s. Worm gear units CMRV CMRV-CMRV... PC-CMRV... CRV CRV-CMRV...

Handbuch für installation, betrieb und wartung Planetengetriebe

VALVE WITH SA ELECTRIC ACTUATOR

BALL VALVE SERIES Electric actuator - El-O-matic

GRUNDFOS DATA BOOKLET. DMX and DMH. Dosing pumps

motor driven metering pumps

GRUNDFOS DATA BOOKLET. DMX and DMH. Dosing pumps

SM-1000 SERIES ROTARY ACTUATORS

MS25, MST25, MS20, MST20

COMBUSTION AND ENERGY

SP3A-15NE 1.1kW 3x V 50Hz

Compact Sheet-Steel Light Fittings Series 6114/1

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

High Torque Geared Motors GB

PKX MA/A. Characteristics

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Circulation pumps BFP-ATEX-T3/T4

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

Sensor boxes SRBE Key features and product range overview

Catalogue geared motors. Edition 01/

Technical Datasheet. Differential Pressure Gauge Diaphragm DG Range. Performance characteristics. Product applications. How can we help you?

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

Load disconnect switch Series 8146/5-V11

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment

ELADOS EMP-KKS Diaphragm Piston Pump Type

XS VALVE WITH SA05 / SA-X05 ELECTRIC ACTUATOR. Model/Ref:

5 TANK ¾ VALVE AND 6 TANK 1 VALVE HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS

10 Load and Motor Switchgear

XS VALVES WITH SA ELECTRIC ACTUATOR. Model/Ref:

F01 Electric Actuators

Euro-HYGIA. Euro-HYGIA s. Construction. Technical data. Applications. Materials. Sanitary pumps 50 Hz. Euro-HYGIA I and II. Food and beverage industry

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

ProMinent Pro M inent Sigma/ 3 Diaphragm Meter ing Pu mps. Diaphragm Rupture Warning System

SP9-11 Rp2 4"1X /50 2.2kW

ExBin-P Pressure switches 5 Pa Pa

Floodlight LED Series 6525

Floodlight Series 6121

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

10 mm solenoid valves on manifold with multiconnection D-SUB

200 SERIES THREADED VALVES PENTAIR CLEAN AIR SYSTEMS

Motorized Butterfly Valve

Transcription:

Motor-driven diaphragm dosing pump, mechanical actuated, PRIUS combines efficiency and chemical resistance to a wide capacity range for an extensive number of applications. ATEX II 2 G c IIB T3, T4 II 2 D IIIC T125 C, resp T135 C Three phase motor power supply Spring return mechanism Manual degassing valve Identification code CIRCUIT CUSTOM. PACKAGING INTERNAL P D 0 0 0 1 0 0 6 0 S V 1 2 0 0 N 0 0 0 BAR CAPACITY 50 Hz 60 Hz 010060 60 l/h @ 10 bar 010055 55 l/h @ 10 bar 010105 105 l/h @ 10 bar 010100 100 l/h @ 10 bar 007160 160 l/h @ 7 bar 007150 150 l/h @ 7 bar 005240 240 l/h @ 5 bar 005230 230 l/h @ 5 bar 010030 30 l/h @ 10 bar 010027 27 l/h @ 10 bar 010056 56 l/h @ 10 bar 010050 50 l/h @ 10 bar 007086 86 l/h @ 7 bar 007075 75 l/h @ 7 bar 005128 128 l/h @ 5 bar 005115 115 l/h @ 5 bar 010024 24 l/h @ 10 bar 010042 42 l/h @ 10 bar 007064 64 l/h @ 7 bar 005096 96 l/h @ 5 bar 010012 12 l/h @ 10 bar 010016 16 l/h @ 10 bar S L/H PUMP HEAD MATERIAL SS COLOR & POWER SUPPLY A 0,18Kw - 1400G - B14 ATEX GAS B 0,25Kw - 1325G - ATEX DUST C 0,37Kw - 1375G - ATEX DUST D 0,37Kw - 1400G - B14 ATEX GAS REDUCTION GEAR 1 8:1 2 15:1 3 10:1 4 20:1 5 40:1 O RING V FKM B D Dutral LUBRICANT TYPE BRAND MODEL MOBIL MOBILGEAR 632 SHELL OMALA OIL 320 BP ENERGOL GR-XP 320 IP MELLANA OIL 320 ESSO SPARTAN EP 320 AGIP BLASIA 320

PRIUS SerieS - 50 Hz / 3-PHASE Features Aluminium enclosure (epoxy coating) Spring return mechanism Power supply 220-240/380-420 V - /Y Environment temperature: -10 40 C (14 104 F) Chemical temperature with SS pump head: -10 90 C (14 194 F)* Installation class... II Pollution level... 2 Audible noise... 78 dba (± 5 db) Protection degree... IP 55 Max suction height... 3 m Oil capacity... 0,3 lt (Refer to Lubricant type table) * The specified temperature can be exceeded temporarily (max 15 ) for sterilization or flushing with hot water.

PRIUS - 50 Hz Power supply... 220-240/380-420 V - /Y PRIUS 50 Hz - ATEX GAS PRESSURE CAPACITY REDUCTION GEAR PUMP HEAD MODEL 010060 10 145 60 15,8 175 0,18 kw 8 : 1 NM R1/2 G1/2 010105 10 145 105 27,7 175 0,37 kw 8 : 1 TM R3/4 G3/4 007160 7 101,5 160 42,3 175 0,37 kw 8 : 1 TM R3/4 G3/4 005240 5 72,5 240 63,4 175 0,37 kw 8 : 1 TM R3/4 G3/4 010030 10 145 30 7,9 94 0,18 kw 15 : 1 NM R1/2 G1/2 010056 10 145 56 14,8 94 0,37 kw 15 : 1 TM R3/4 G3/4 007086 7 101,5 86 22,7 94 0,37 kw 15 : 1 TM R3/4 G3/4 005128 5 72,5 128 33,8 94 0,37 kw 15 : 1 TM R3/4 G3/4 010024 10 145 24 6,3 70 0,18 kw 20 : 1 NM R1/2 G1/2 010042 10 145 42 11,1 70 0,37 kw 20 : 1 TM R3/4 G3/4 007064 7 101,5 64 16,9 70 0,37 kw 20 : 1 TM R3/4 G3/4 005096 5 72,5 96 25,4 70 0,37 kw 20 : 1 TM R3/4 G3/4 010012 10 145 12 3,17 35 0,18 kw 40 : 1 NM R1/2 G1/2 010016 10 145 16 4,22 35 0,18 kw 40 : 1 NM R1/2 G1/2 PRIUS 50 Hz - ATEX DUST PRESSURE CAPACITY REDUCTION GEAR PUMP HEAD MODEL 010060 10 145 60 15,8 175 0,25 kw 8 : 1 NM R1/2 G1/2 010105 10 145 105 27,7 175 0,37 kw 8 : 1 TM R3/4 G3/4 007160 7 101,5 160 42,3 175 0,37 kw 8 : 1 TM R3/4 G3/4 005240 5 72,5 240 63,4 175 0,37 kw 8 : 1 TM R3/4 G3/4 010030 10 145 30 7,9 94 0,25 kw 15 : 1 NM R1/2 G1/2 010056 10 145 56 14,8 94 0,37 kw 15 : 1 TM R3/4 G3/4 007086 7 101,5 86 22,7 94 0,37 kw 15 : 1 TM R3/4 G3/4 005128 5 72,5 128 33,8 94 0,37 kw 15 : 1 TM R3/4 G3/4 010024 10 145 24 6,3 70 0,25 kw 20 : 1 NM R1/2 G1/2 010042 10 145 42 11,1 70 0,37 kw 20 : 1 TM R3/4 G3/4 007064 7 101,5 64 16,9 70 0,37 kw 20 : 1 TM R3/4 G3/4 005096 5 72,5 96 25,4 70 0,37 kw 20 : 1 TM R3/4 G3/4 010012 10 145 12 3,17 35 0,25 kw 40 : 1 NM R1/2 G1/2 010016 10 145 16 4,22 35 0,25 kw 40 : 1 NM R1/2 G1/2

PRIUS SERIES - 60 Hz / 3-PHASE Features Aluminium enclosure (epoxy coating) Spring return mechanism Power supply: 40-480 V - Y connection Environment temperature: -10 40 C (14 104 F) Chemical temperature with SS pump head: -10 90 C (14 194 F)* Installation class...ii Pollution level...2 Audible noise...78 dba (± 5 db) Protection degree...ip 55 Max suction height...3 m Oil capacity...0,3 lt (Refer to Lubricant type table) * The specified temperature can be exceeded temporarily (max 15 ) for sterilization or flushing with hot water.

PRIUS - 60 Hz Power supply... 440-480 V - Y PRIUS 60 Hz - ATEX GAS 010055 10 145 55 15,4 175 0,18 kw 10 : 1 NM R1/2 G1/2 010100 10 145 100 26,4 175 0,37 kw 10 : 1 TM R3/4 G3/4 007150 7 101,5 150 39,6 175 0,37 kw 10 : 1 TM R3/4 G3/4 005230 5 72,5 230 60,8 175 0,37 kw 10 : 1 TM R3/4 G3/4 010027 10 145 27 7,1 87 0,18 kw 20 : 1 NM R1/2 G1/2 010050 10 145 50 13,2 87 0,37 kw 20 : 1 TM R3/4 G3/4 007075 7 101,5 75 19,8 87 0,37 kw 20 : 1 TM R3/4 G3/4 005115 5 72,5 115 30,4 87 0,37 kw 20 : 1 TM R3/4 G3/4 PRIUS 60 Hz - ATEX DUST PUMP HEAD PRESSURE CAPACITY REDUC- MODEL TION GEAR PUMP HEAD PRESSURE CAPACITY REDUC- MODEL TION GEAR 010055 10 145 55 15,4 175 0,25 kw 10 : 1 NM R1/2 G1/2 010100 10 145 100 26,4 175 0,37 kw 10 : 1 TM R3/4 G3/4 007150 7 101,5 150 39,6 175 0,37 kw 10 : 1 TM R3/4 G3/4 005230 5 72,5 230 60,8 175 0,37 kw 10 : 1 TM R3/4 G3/4 010027 10 145 27 7,1 87 0,25 kw 20 : 1 NM R1/2 G1/2 010050 10 145 50 13,2 87 0,37 kw 20 : 1 TM R3/4 G3/4 007075 7 101,5 75 19,8 87 0,37 kw 20 : 1 TM R3/4 G3/4 005115 5 72,5 115 30,4 87 0,37 kw 20 : 1 TM R3/4 G3/4

Dimensions DIMENSIONS (mm) NM pump head (SS) TM pump head (SS) A 320 310 B 280 278 C 157 157 L 177 220 G 163 163 H 190 190 I 97,5 110 F 400 460 E 125,2 125,2 D 108,6 108,6 fixing holes 8 8 Exploded view