Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

Similar documents
GS2 Series - Introduction

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

USERS MANUAL MCD REMOTE OPERATOR

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Low voltage AC drives

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

ABB Component Drives ACS150, 0.5 to 5 Hp

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B. Revision. Edition 07/ / EN

High performance Vector Control. Ratings. System configuration

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

VSD Series II Variable Speed Micro Drives

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

JC-VSD FP Series II Drives Product Bulletin 1

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

J1000. Compact Inverter Series.

HVAC Products. Introducing the SED2 Variable Frequency Drives

ABB component drives ACS150, 0.5 to 5 Hp

EPS/ELA-Series User Manual EPS/ELA 250W


HIB Enclosed Inverter User Guide

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

ALTIVAR 18 AC Drives. File 8805

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

Fincor Series 2230 MKII/2240

User Manual. Solar Charge Controller 3KW

Altistart 48 Y-Range Soft Start Controllers Installation Guide

L300P Inverter Specifications

Description 1/8-7.5HP

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Delta Products VFD CP2000 Bypass Control Packages.

SD1 Series General Purpose AC Variable Speed Drives

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

RVS-AX Instruction Manual

BR Second Position Voltages. AA Fourth Position

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

V1000. Inverter Series.

V1000 Inverter Series

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Revision MOVITRAC LTE-B * _1114*

VSD Series II Variable Speed Open Drives

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Electronic Ballast EVG 2000-T

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

CATALOG. ABB micro drives ACS255, 0.25 to 20 hp / 0.37 to 15 kw

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

MULTI LANGUAGE KEYPAD

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

User Manual Solar Charge Controller 3KW

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Application Description

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

MaxPak Plus Analog DC V S Drive

Frequency Inverters SJ Series Type P1

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Shenzhen Sine Electric Co., Ltd.

SYSDrive Frequency Inverter

Variable speed drive ALSPA MV1000. Power Conversion. General Drives

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

MATRIX LLC LEVEL CONTROL PANEL

Frame size R2, IP20 / NEMA 1

MCW Application Notes 24 th August 2017

VSD Series II Variable Speed Enclosed IntelliPass and IntelliDisconnect Drives

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

Continental Hydraulics Installation Manual CEM-AA-A

VFD E Series. Features

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

SSW07. Soft Starters. Applications. Standard Features

ABB standard drives ACS550, Hp

Technical Information

Quick Start Guide of CV50- ControlVIT Series

Stock Drives Catalogue. Variable Speed Drives & Accessories

RVS-DN Digital Reduced Voltage Motor Starter

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

ABB Drives ACS550-U1-059A-2, 20 HP, 3PH, 200 VAC, Wall Mount VFD

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

ALTIVAR 58 AC Drives

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

DYNEO Synchronous motors with permanent magnets-drive Commissioning

Appendix: Safety and application notes for 19

Mclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546

Transcription:

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP Edition 03/2009 Catalog 16798015 / EN

SEW-EURODRIVE Driving the world

1 Important Notes... 4 1.1 Structure of the safety notes... 4 1.2 Application environment... 5 1.3 Waste disposal... 5 2 Safety Notes... 6 2.1 Installation and startup... 6 2.2 Operation and servicing... 6 3 General specifications... 7 3.1 Input voltage ranges... 7 3.2 Product designation... 8 3.3 Output power and current ratings... 9 3.4 Overload capability... 19 3.5 Protection features... 19 3.6 Conformance... 19 3.7 Environmental... 20 3.8 Dimensions... 21 3.9 IP20 housing: mounting and dimensions of switch cabinet... 23 3.10 Signal terminal overview... 25 3.11 Communication Interfaces... 26 3.12 User interface... 27 3.13 Parameter specifications:... 28 3.14 Selection of Parameter P2-01, Digital Input Function... 35 4 Accessories... 42 4.1 Braking resistors... 42 4.2 Line chokes... 49 4.3 Output chokes... 51 4.4 DIN rail mounting kit... 54 4.5 Remote keypad option LT BG-00... 54 4.6 Cable splitter 1 in and 2 out... 56 4.7 Prefabricated cables with RJ11 connector... 56 4.8 Interface adapter option UWS11A... 57 4.9 Interface adapter option LT-W-USB-RJ11... 58 4.10 Second relay output... 59 4.11 Third relay output... 61 4.12 Two indicator relay... 63 4.13 Converter card... 65 4.14 Local switchboard... 67 4.15 Lock... 68 4.16 MC LTP CE, Pocket PC BG LT OWDCE... 68 4.17 Fieldbus Communication... 69 5 Select a motor... 70 5.1 Project planning flowchart... 70 5.2 Inverter motor combinations... 71 6 Index... 77 Catalog MOVITRAC LTP 3

Important Notes 1 Structure of the safety notes Catalog 1 Important Notes 1.1 Structure of the safety notes The safety notes in these operating instructions are structured as follows: Symbol SIGNAL WORD Nature and source of hazard. Possible consequence(s) if disregarded. Measure(s) to avoid the hazard. Symbol Signal Word Meaning Consequences if disregarded Example: HAZARD Imminent hazard Severe or fatal injuries General hazard WARNING Possible hazardous situation Severe or fatal injuries CAUTION Possible hazardous situation Minor injuries Specific hazard, e.g. electric shock STOP Possible damage to property Damage to the drive system or its environment NOTE Useful information or tip Simplifies drive system handling Unless the information in the operating instructions is adhered to, it will be impossible to ensure: Trouble-free operation Fulfillment of any rights to claim under guarantee Consequently, read the operating instructions before you start working with the unit! The operating instructions contain important information about servicing. Therefore, keep the operating instructions close to the unit. 4 Catalog MOVITRAC LTP

Important Notes Application environment 1 1.2 Application environment The following applications are forbidden unless measures are expressly taken to make them possible: Use in explosion-proof areas Use in environments with harmful substances: Oils Acids Gases Vapors Dust Radiated interference Other harmful environments Use subject to mechanical vibration and shock loads in excess of the requirements in EN 50178 If the inverter performs safety functions which have to guarantee the protection of machinery and people 1.3 Waste disposal Please follow the current instructions: dispose in accordance with the regulations in force: Electronics scrap (printed-circuit boards) Plastic (housing) Sheet metal Copper Catalog MOVITRAC LTP 5

Safety Notes 2 Installation and startup 2 Safety Notes MOVITRAC LTP drive inverters may not perform safety functions without higher-level safety systems. Do not use MOVITRAC LTP drive inverters for any safety functions in conjunction with hoist applications. 2.1 Installation and startup Never install damaged products or take them into operation. Please submit a complaint to the transport company immediately in the event of damage. Installation, startup and service work on the unit only by trained personnel. The personnel must be trained in the relevant aspects of accident prevention and must comply with the regulations in force (e.g. EN 60204, VBG 4, DIN VDE 0100/0113/0160). Follow the specific instructions during installation and startup of the motor and the brake! Make sure that preventive measures and protection devices correspond to the applicable regulations (e.g. EN 60204 or EN 50178). Grounding the unit is a necessary protective measure. Overcurrent protection devices are a necessary protective measure. The unit meets all requirements for reliable isolation of power and electronics connections in accordance with UL508. All connected circuits must also satisfy the requirements for reliable isolation so as to guarantee reliable isolation. Take suitable measures to ensure that the connected motor does not start up automatically when the inverter is switched on. To do this, you can connect binary inputs DI01 through DI03 to GND. 2.2 Operation and servicing WARNING Danger of electrical shock. High voltages are present in the terminals and in within the drive for up to 10 minutes after the electrical supply has been disconnected. Severe or fatal injuries. Disconnect and isolate the MOVITRAC LTP from the electrical supply at least 10 minutes before commencing any work on it. Dangerous voltages are present in the output terminals and the cables and motor terminals connected to them when the unit is switched on. Dangerous voltages may also be present when the unit is inhibited and the motor at a standstill. The unit is not necessarily deenergized when the LEDs and the 7-segment display are off. Safety functions inside the unit or a mechanical blockage may cause the motor to stop. The removal of the source of the malfunction or a reset can result in an automatic restart of the drive. If, for safety reasons, this is not permissible for the driven machine, disconnect the unit from the supply system before correcting the fault. 6 Catalog MOVITRAC LTP

General specifications Input voltage ranges kva i P f n Hz 3 3 General specifications 3.1 Input voltage ranges Depending upon model and power rating, the drives are designed for direct connection to the following supplies: MOVITRAC LTP 240 V units: 200 240 V ± 10 %, 1-phase* / 3-phase, 50 60 Hz ± 5 % NOTE *It is also possible to connect 1-phase MOVITRAC LTP units to 2-phases of a 200 240 V, 3-phase mains. MOVITRAC LTP 400 V units: 380 480 V ± 10 %, 3-phase, 50 60 Hz ± 5 % MOVITRAC LTP 525 V units: 480 525 V ± 10 %, 3-phase, 50 60 Hz ± 5 % (Sizes 5 & 6 only) MOVITRAC LTP 575 V units: 500 600 V ± 10 %, 3-phase, 50 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance of 3 % between phases. For input supplies which have a supply imbalance greater than 3 % (typically the Indian subcontinent and parts of Asia Pacific including China) we recommend that input chokes are used. Catalog MOVITRAC LTP 7

n kva 3 f General specifications i Product designation P Hz 3.2 Product designation MC LTP A 0015 2 0 1 1 00 (60 Hz) 60 Hz American version only Type Quadrants Connection type Interference suppression on the supply side Mains voltage Recommended motor power 00 = Standard IP20 / NEMA 1 housing 10 = IP55 / NEMA 12 housing 20 = IP55 / NEMA 12 housing with switch 50 = 525 V, standard IP20 / NEMA 1 housing 0M = Optional Modbus Firmware 1 = 1Q (without brake chopper) 4 = 4Q (with brake chopper) 1 = 1-phase 3 = 3-phase 0 = class 0 A = class A B = class B 1 = 115 V 2 = 200 240 V 5 = 380 480 V 6 = 500 600 V 0015 = 1.5 kw Version A Product type MC LTP 8 Catalog MOVITRAC LTP

General specifications Output power and current ratings kva i P f n Hz 3 3.3 Output power and current ratings 3.3.1 1-phase system AC 230 V for 3-phase AC 230 V motors (Size 1) Standard MOVITRAC MC LTP A... 0004 2B1 1-00 0008 2B1 1-00 0015 2B1 1-00 Part number 8286914 8286922 8299226 IP55 / NEMA 12 housing MOVITRAC MC LTP A... 0004 2B1 1-10 0008 2B1 1-10 0015 2B1 1-10 Part number 8291756 8291764 8299234 IP55 / NEMA 12 with switch MOVITRAC MC LTP A... 0004 2B1 1-20 0008 2B1 1-20 0015 2B1 1-20 Part number 8291799 8291802 8299242 INPUT Supply voltage [V mains ] 200 240 V ± 10 %, 1-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 10 16 20 Nominal input current [A] 6.7 12.5 19.3 OUTPUT Recommended motor power [kw] 0.37 0.75 1.5 [hp] 0.5 1 2 Output voltage [V] 3 20 250 V Output current [A] 2.3 4.3 7 Motor cable size Cu 75C [mm 2 ] 1.5 [AWG] 16 Max motor cable length Shielded 25 [m] Unshielded 40 GENERAL Heat loss at nominal output power [W] 11 22 45 Minimal braking resistor value [Ω] Catalog MOVITRAC LTP 9

kva 3 f General specifications Output power and current ratings i n P Hz 3.3.2 1-phase system AC 230 V for 3-phase AC 230 V motors (Size 2) Standard MOVITRAC MC LTP A... 0015 2B1 4-00 0022 2B1 4-00 Part number 8286949 8286957 IP55 / NEMA 12 housing MOVITRAC MC LTP A... 0015 2B1 4-10 0022 2B1 4-10 Part number 8291772 8291780 IP55 / NEMA 12 with switch MOVITRAC MC LTP A... 0015 2B1 4-20 0022 2B1 4-20 Part number 8294925 8294933 INPUT Supply voltage [V mains ] 200 240 V ± 10 %, 1-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 20 32 Nominal input current [A] 19.3 28.8 OUTPUT Recommended motor power [kw] 1.5 2.2 [hp] 2 3 Output voltage [V] 3 20 250 V Output current [A] 7 10.5 Motor cable size Cu 75C [mm 2 ] 1.5 [AWG] 16 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 45 66 Minimal braking resistor value [Ω] 33 22 10 Catalog MOVITRAC LTP

General specifications Output power and current ratings kva i P f n Hz 3 3.3.3 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 2) Standard MOVITRAC MC LTP A... 0015 2B3 4-00 0022 2B3 4-00 Part number 8299250 8299269 IP55 / NEMA 12 housing MOVITRAC MC LTP A... 0015 2B3 4-10 0022 2B3 4-10 Part number 8299277 8299285 IP55 / NEMA 12 with switch MOVITRAC MC LTP A... 0015 2B3 4-20 0022 2B3 4-20 Part number 8299293 8299307 INPUT Supply voltage [V mains ] 200 240 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 20 32 Nominal input current [A] 19.3 28.8 OUTPUT Recommended motor power [kw] 1.5 2.2 [hp] 2 3 Output voltage [V] 3 20 250 V Output current [A] 7 10.5 Motor cable size Cu 75C [mm 2 ] 1.5 [AWG] 16 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 45 66 Minimal braking resistor value [Ω] 33 22 Catalog MOVITRAC LTP 11

kva 3 f General specifications Output power and current ratings i n P Hz 3.3.4 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 3) MOVITRAC MC LTP A... 0030 2A3 4-00 0040 2A3 4-00 0055 2A3 4-00 Part number 8286965 8286973 8286981 INPUT Supply voltage [V mains ] 200 240 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 32 50 Nominal input current [A] 16.1 17.3 25 OUTPUT Recommended motor power [kw] 3 4 5.5 [hp] 4 5 7.5 Output voltage [V] 3 20 250V Output current [A] 14 18 24 Motor cable size Cu 75C [mm 2 ] 2.5 4 [AWG] 12 10 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 90 120 165 Minimal braking resistor value [Ω] 15 3.3.5 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 4) MOVITRAC MC LTP A... 0075 2A3 4-00 0110 2A3 4-00 0150 2A3 4-00 0185 2A3 4-00 Part number 8287007 8287015 8287023 8287031 INPUT Supply voltage [V mains ] 200 240 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 50 63 80 Nominal input current [A] 46.6 54.1 69.6 76.9 OUTPUT Recommended motor power [kw] 7.5 11 15 18.5 [hp] 10 15 20 25 Output voltage [V] 3 20 250 V Output current [A] 39 46 61 72 Motor cable size Cu 75C [mm 2 ] 10 16 [AWG] 6 4 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 225 330 450 555 Minimal braking resistor value [Ω] 6 12 Catalog MOVITRAC LTP

General specifications Output power and current ratings kva i P f n Hz 3 3.3.6 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 5) MOVITRAC MC LTP A... 0220 2A3 4-00 0300 2A3 4-00 0370 2A3 4-00 0450 2A3 4-00 Part number 8287058 8287066 8287074 8287082 INPUT Supply voltage [V mains ] 200 240 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 160 200 250 300 Nominal input current [A] 92.3 116.9 140.2 176.5 OUTPUT Recommended motor power [kw] 22 30 37 45 [hp] 30 40 50 60 Output voltage [V] 3 20 250 V Output current [A] 90 110 150 180 Motor cable size Cu 75C [mm 2 ] 25 35 55 70 [AWG] 4 3 2 / 0 3 / 0 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 660 900 1110 1350 Minimal braking resistor value [Ω] 3 3.3.7 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 6) MOVITRAC MC LTP A... MC LTP A... 0550 2A3 4-00 0750 2A3 4-00 0900 2A3 4-00 Part number 8287090 8287104 8287112 INPUT Supply voltage [V mains ] 200 240 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 315 350 400 450 500 Nominal input current [A] 217.2 255.7 302.4 OUTPUT Recommended motor power [kw] 55 75 90 [hp] 75 100 120 Output voltage [V] 3 20 250 V Output current [A] 202 240 300 Motor cable size Cu 75C [mm 2 ] 90 120 170 [AWG] 3 / 0 4 / 0 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 1650 2250 2700 Minimal braking resistor value [Ω] 3 Catalog MOVITRAC LTP 13

kva 3 f General specifications Output power and current ratings i n P Hz 3.3.8 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 2) Standard MOVITRAC MC LTP A... 0008 5A3 4-00 0015 5A3 4-00 0022 5A3 4-00 0040 5A3 4-00 Part number 8287147 8287155 8287163 8287171 IP55 / NEMA 12 housing MOVITRAC MC LTP A... 0008 5A3 4-10 0015 5A3 4-10 0022 5A3 4-10 0040 5A3 4-10 Part number 8292582 8292590 8292604 8292612 IP55 / NEMA 12 with switch MC LTP A... 0008 5A3 4-20 0015 5A3 4-20 0022 5A3 4-20 0040 5A3 4-20 MOVITRAC Part number 8292620 8292639 8292647 8292655 INPUT Supply voltage [V mains ] 380 480 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 6 10 10 16 20 Nominal input current [A] 2.9 5.4 7.6 12.4 OUTPUT Recommended motor power [kw] 0.75 1.5 2.2 4 [hp] 1 2 3 5 Output voltage [V] 3 20 480V Output current [A] 2.2 4.1 5.8 9.5 Motor cable size Cu 75C [mm 2 ] 1.0 1.5 [AWG] 17 16 Max. motor cable length Shielded 50 100 [m] Unshielded 75 150 GENERAL Heat loss at nominal output power [W] 22 45 66 120 Minimal braking resistor value [Ω] 47 33 3.3.9 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 3) MOVITRAC MC LTP A... 0055 5A3 4-00 0075 5A3 4-00 0110 5A3 4-00 0150 5A3 4-00 Part number 8287198 8287201 8287228 8287236 INPUT Supply voltage [V mains ] 380 480 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 32 50 Nominal input current [A] 16.1 17.3 25 32.9 OUTPUT Recommended motor power [kw] 5.5 7.5 11 15 [hp] 7.5 10 15 20 Output voltage [V] 3 20 480V Output current [A] 14 18 24 30 Motor cable size Cu 75C [mm 2 ] 2.5 4.0 6.0 [AWG] 12 10 8 Max motor cable length Shielded 100 (unshielded) [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 165 225 330 450 Minimal braking resistor value [Ω] 22 14 Catalog MOVITRAC LTP

General specifications Output power and current ratings kva i P f n Hz 3 3.3.10 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 4) MOVITRAC MC LTP A... 0185 5A3 4-00 0220 5A3 4-00 0300 5A3 4-00 0370 5A3 4-00 Part number 8287244 8287252 8287260 8287279 INPUT Supply voltage [V mains ] 380 480 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 80 80 100 100 125 Nominal input current [A] 46.6 54.1 69.6 76.9 OUTPUT Recommended motor power [kw] 18.5 22 30 37 [hp] 25 30 40 50 Output voltage [V] 3 20 480 V Output current [A] 39 46 61 72 Motor cable size Cu 75C [mm 2 ] 10 16 [AWG] 6 4 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 555 660 900 1110 Minimal braking resistor value [Ω] 12 3.3.11 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 5) MOVITRAC MC LTP A... 0450 5A3 4-00 0550 5A3 4-00 0750 5A4 4-00 0900 5A3 4-00 Part number 8287287 8287295 8287309 8287317 INPUT Supply voltage [V mains ] 380 480 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 160 200 250 300 Nominal input current [A] 92.3 116.9 150.2 176.5 OUTPUT Recommended motor power [kw] 45 55 75 90 [hp] 60 75 100 120 Output voltage [V] 3 20 480V Output current [A] 90 110 150 180 Motor cable size Cu 75C [mm 2 ] 25 55 70 [AWG] 4 2 / 0 3 / 0 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 1350 1650 2250 2700 Minimal braking resistor value [Ω] 6 Catalog MOVITRAC LTP 15

kva 3 f General specifications Output power and current ratings i n P Hz 3.3.12 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 6) MOVITRAC MC LTP A... 1100 5A3 4-00 1320 5A3 4-00 1600 5A3 4-00 Part number 8287325 8287333 8287341 INPUT Supply voltage [V mains ] 380 480 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 315 350 400 450 500 Nominal input current [A] 217.2 255.7 302.4 OUTPUT Recommended motor power [kw] 110 132 160 [hp] 150 175 200 Output voltage [V] 3 20 480V Output current [A] 202 240 300 Motor cable size Cu 75C [mm 2 ] 90 120 170 [AWG] 4 / 0 5 / 0 6 / 0 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 3300 3960 4800 Minimal braking resistor value [Ω] 6 3.3.13 3-phase system AC 575 V for 3-phase AC 575 V motors (Size 2) Standard MOVITRAC MC LTP A... 0008 603 4-00 0015 603 4-00 0022 603 4-00 0037 603 4-00 0055 603 4-00 Part number 8286833 8286841 8286868 8286876 8286884 IP55 / NEMA 12 housing MC LTP A... 0008 603 4-10 0015 603 4-10 0022 603 4-10 0037 603 4-10 0055 603 4-10 MOVITRAC Part number 8290814 8290822 8290830 8290849 8290857 IP55 / NEMA 12 with switch MC LTP A... 0008 603 4-20 0015 603 4-20 0022 603 4-20 0037 603 4-20 0055 603 4-20 MOVITRAC Part number 8290865 8290873 8290881 8290903 8290911 INPUT Supply voltage [V mains ] 500 600 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 6 10 20 Nominal input current [A] 2.2 4.1 6.1 7.6 11.7 OUTPUT Recommended motor power [kw] 0.75 1.5 2.2 3.7 5.5 [hp] 1 2 3 5 7.5 Output voltage [V] 3 20 575 V Output current [A] 1.7 3.1 4.1 6.1 9 Motor cable size Cu 75C [mm 2 ] 1.0 1.5 [AWG] 17 16 Max motor Shielded 100 cable length [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 22 45 66 111 165 Minimal braking resistor value [Ω] 47 16 Catalog MOVITRAC LTP

General specifications Output power and current ratings kva i P f n Hz 3 3.3.14 3-phase system AC 575 V for 3-phase AC 575 V motors (Size 3) MOVITRAC MC LTP A... 0075 603 4-00 0110 603 4-00 0150 603 4-00 Part number 8286892 8286906 8298139 INPUT Supply voltage [V mains ] 500 600 V ±10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 25 32 Nominal input current [A] 16.1 17.3 25.1 OUTPUT Recommended motor power [kw] 7.5 11 15 [hp] 10 15 20 Output voltage [V] 3 20 575 V Output current [A] 14 18 24 Motor cable size Cu 75C [mm 2 ] 2.5 4 [AWG] 14 10 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 185 330 450 Minimal braking resistor value [Ω] 22 3.3.15 3-phase system AC 575 V for 3-phase AC 575 V motors (Size 4) MOVITRAC MC LTP A... 0220 603 4-00 0300 603 4-00 0450 603 4-00 Part number 8298149 8298157 8298165 INPUT Supply voltage [V mains ] 500 600 V ±10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 50 63 80 Nominal input current [A] 46.6 54.1 69.6 OUTPUT Recommended motor power [kw] 22 30 45 [hp] 30 40 60 Output voltage [V] 3 20 575 V Output current [A] 39 46 62 Motor cable size Cu 75C [mm 2 ] 10 16 [AWG] 6 4 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 660 900 1350 Minimal braking resistor value [Ω] 12 Catalog MOVITRAC LTP 17

kva 3 f General specifications Output power and current ratings i n P Hz 3.3.16 3-phase system AC 525 V for 3-phase AC 500 V motors (Size 5) MOVITRAC MC LTP A... 0550 603 4-50 0750 603 4-50 0900 603 4-50 Part number 8299315 8299323 8299331 INPUT Supply voltage [V mains ] 480 525 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 125 160 200 Nominal input current [A] 92.3 116.9 150.2 OUTPUT Recommended motor power [kw] 55 75 90 [hp] 75 100 120 Output voltage [V] 3 20 525 V Output current [A] 90 110 150 Motor cable size Cu 75C [mm 2 ] 35 50 70 [AWG] 4 2 / 0 3 / 0 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 1650 2250 2770 Minimal braking resistor value [Ω] 6 3.3.17 3-phase system AC 525 V for 3-phase AC 500 V motors (Size 6) MOVITRAC MC LTP A... 1320 603 4-50 1600 603 4-50 2000 603 4-50 Part number 8299358 8299366 8299374 INPUT Supply voltage [V mains ] 480 525 V ± 10 %, 3-phase Supply frequency [f mains ] 50 / 60 Hz Supply fuse rating [A] 300 400 Nominal input current [A] 217.2 255.7 290 OUTPUT Recommended motor power [kw] 132 160 200 [hp] 175 210 250 Output voltage [V] 3 20 525 V Output current [A] 202 240 270 Motor cable size Cu 75C [mm 2 ] 90 120 170 [AWG] 5 / 0 6 / 0 Max motor cable length Shielded 100 [m] Unshielded 150 GENERAL Heat loss at nominal output power [W] 3960 4800 6000 Minimal braking resistor value [Ω] 6 18 Catalog MOVITRAC LTP

General specifications Overload capability kva i P f n Hz 3 3.4 Overload capability All MOVITRAC LTP units have a possible overload of: 150 % for 60 seconds 175 % for 2 seconds 3.5 Protection features Output short-circuit, phase-to-phase, phase-to-ground Output over-current Trip set at 175 % of rated drive current. Overload protection Drive delivers 150 % of rated motor current for 60 seconds. Braking transistor protected against short-circuit. Braking resistor overload (when enabled) Over-voltage trip Set at 123 % of drive maximum rated supply voltage. Under-voltage trip Over temperature trip Under temperature trip Drive will trip if enabled below 10 C Supply phase imbalance A running drive will trip if there is a supply imbalance of > 3 % persisting for more than 30 seconds. Supply phase loss A running drive will trip if one phase of a 3-phase supply is lost for more than 15 seconds. 3.6 Conformance All products conform to the following international standards: UL 508C Power conversion equipment EN 61000-6 / -2, -3, -4 Generic immunity / Emission standards (EMC) Enclosure protection level according to NEMA 250, EN 60529 Flammability rating according to UL 94 cul Power conversion equipment, certified for Canada Catalog MOVITRAC LTP 19

n kva General specifications 3 f i Environmental P Hz 3.7 Environmental Operational ambient temperature range Maximum ambient temperature derating 0 50 C at default PWM frequency (IP20) 0 40 C at default PWM frequency (IP55, NEMA 12k) 4 % / C up to 55 C for IP20 drives 4 % / C up to 45 C for IP55 drives Storage ambient temperature range 40 +60 C Maximum altitude for rated operation 1000 m Derating above 1000 m 1 % / 100 m to max. 2000 m Maximum relative humidity 95 % (non-condensing) Protection rating cabinet drive IP20 Protection rating high enclosure drive IP55, NEMA 12 k 20 Catalog MOVITRAC LTP

General specifications Dimensions kva i P f n Hz 3 3.8 Dimensions MOVITRAC LTP is available in 2 housing versions: Standard IP20 / NEMA 1 housing for use in switch cabinets IP55 / NEMA 12 version for size 1 and size 2 drives The IP55 / NEMA 12 housing is protected against moisture and dust. Therefore, the drives can be operated indoors under harsh conditions. Electronically, the drives are identical and the only differences are the dimensions of the housing and the weight. 3.8.1 Dimensions of the IP20 / NEMA 1 housing b a b c A d C c B 54769AXX 54781AXX 54770AXX Dimension Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 1) Height (A) [mm] 155 260 260 520 1045 1100 [in] 6.10 10.20 10.20 20.47 41.14 43.31 Width (B) [mm] 80 100 171 340 340 340 [in] 3.15 3.94 6.73 13.39 13.39 13.39 Depth (C) [mm] 130 175 175 220 220 330 [in] 5.12 6.89 6.89 8.66 8.66 12.99 Weight Unit = 55 [kg] 1.1 2.6 5.3 28 68 Choke = 27 [lb] 2.43 5.73 11.68 61.73 149.91 149.91 a [mm] 72 92 163 320 320 320 [in] 2.84 3.62 6.42 12.6 12.6 12.6 b [mm] 4 4 4 9.5 9.5 9.5 [in] 0.16 0.16 0.16 0.37 0.37 0.37 c [mm] 25 25 25 50 50 50 [in] 0.98 0.98 0.98 1.97 1.97 1.97 d [mm] 105 210 210 420 945 945 [in] 4.13 8.27 8.27 16.54 37.21 37.21 Power terminal [Nm] 1 1 1 4 8 8 torque settings [lb.in] 8.85 8.85 8.85 35.4 70.8 70.8 Fixings 2 M4 2 M4 4 M4 4 M8 4 M8 4 M8 1) Size 6 comes with an external line choke Catalog MOVITRAC LTP 21

n kva General specifications 3 f i Dimensions P Hz 3.8.2 Dimensions of the IP55 / NEMA 12 housing (LTP xxx 10 and 20) b a b c Z A d X Y X B C c 60198AXX 60200AXX 60199AXX 60497AXX Dimension Size 1 Size 2 Height (A) [mm] 200 310 [in] 7.9 12.2 Width (B) [mm] 140 165 [in] 5.5 6.5 Depth (C) [mm] 165 176 [in] 6.5 6.9 Weight [kg] 2.3 4.5 [lb] 5.1 9.9 a [mm] 128 153 [in] 5 6 b [mm] 6 6 [in] 0.23 0.23 c [mm] 25 25 [in] 0.98 0.98 d [mm] 142 252 [in] 5.6 9.9 X [mm] 22 25 [in] 0.87 0.98 Y 1) [mm] 22 22 [in] 0.87 0.87 Z 1) [mm] 17 17 Power terminal torque settings Control terminal torque settings [in] 0.67 0.67 [Nm] 1 1 [lb.in] 8.85 8.85 [Nm] 0.5 0.5 [lb.in] 4.43 4.43 Fixings 2 M4 4 M4 1) Glands Y and Z are flip out glands. 22 Catalog MOVITRAC LTP

General specifications IP20 housing: mounting and dimensions of switch cabinet kva i P f n Hz 3 3.9 IP20 housing: mounting and dimensions of switch cabinet For applications that require a higher IP rating than the IP20 offered by the standard drive, the drive must be mounted in a switch cabinet. The following guidelines should be observed for these applications: The switch cabinet should be made from a thermally conductive material, unless forced ventilation is used. When a vented switch cabinet is used, there should be venting above and below the drive to ensure good air circulation. Air should be drawn in below the drive and expelled above the drive. If the external environment contains contamination particles (e.g. dust), a suitable particle filter should be fitted to the vents and forced ventilation implemented. The filter must be serviced and cleaned appropriately. High moisture, salt or chemical content environments should use a suitably sealed (non-vented) switch cabinet. 3.9.1 Dimensions of non-vented metal switch cabinet Sealed switch cabinet Drive power rating A B C D [mm] [in] [mm] [in] [mm] [in] [mm] [in] Size 1 0.75 kw 230 V 300 11.81 250 9.84 200 7.87 50 1.97 Size 1 1.5 kw 230 V 400 15.75 300 11.81 250 9.84 75 2.95 Size 2 1.5 kw 230 V 0.75 kw, 1.5 kw, 2.2 kw 400 V 2.2 kw 400 V 400 15.75 300 11.81 300 11.81 60 2.36 Size 2 2.2 kw 230 V 4.0 kw 400 V 5.5 kw 575 V 600 23.62 450 17.72 300 11.81 100 3.94 C B D A D Figure 1: Switch cabinet 54784AXX Catalog MOVITRAC LTP 23

kva 3 f General specifications IP20 housing: mounting and dimensions of switch cabinet i n P Hz 3.9.2 Dimensions of vented switch cabinet Vented switch cabinet Drive power rating A B C D [mm] [in] [mm] [in] [mm] [in] [mm] [in] Size 1 1.5 kw 400 15.75 300 11.81 150 5.91 75 2.95 Size 2 5.5 kw 600 23.62 400 15.75 250 9.84 100 3.94 Size 3 15 kw 800 31.50 600 23.62 300 11.81 150 5.91 Size 4 22 kw 1000 39.37 600 23.62 300 11.81 200 7.87 Size 4 37 kw Size 5 90 kw Size 6 160 kw 3.9.3 Dimensions of force-vented switch cabinet Force-vented switch cabinet (with fan) Drive power rating A B C D [mm] [in] [mm] [in] [mm] [in] [mm] [in] Air Flow Size 1 1.5 kw 275 10.83 150 5.91 150 5.91 50 1.97 > 15 m 3 / h Size 2 5.5 kw 320 12.60 200 7.87 250 9.84 75 2.95 > 45 m 3 / h Size 3 15 kw 400 15.75 250 9.84 250 9.84 100 3.94 > 80 m 3 / h Size 4 22 kw 800 31.50 500 19.69 300 11.81 130 5.12 > 300 m 3 / h Size 4 37 kw 800 31.50 500 19.69 300 11.81 130 5.12 > 300 m 3 / h Size 5 90 kw 1500 59.06 600 23.62 400 15.75 200 7.87 > 900 m 3 / h Size 6 160 kw 1600 62.99 600 23.62 400 15.75 250 9.84 > 1000 m 3 / h 24 Catalog MOVITRAC LTP

General specifications Signal terminal overview kva i P f n Hz 3 3.10 Signal terminal overview The User Control terminals are available via an 11-way pluggable connector. All terminals are galvanically isolated, allowing direct connection to other equipment. STOP! Danger of damage to the MOVITRAC LTP unit. Do not connect mains supply voltages to any terminals other than the user relay output. Doing so will result in permanent damage to the unit. The user relay output can handle up to AC 250 V. All other inputs only withstand DC 30 V without damage. The functionality of the inputs and outputs is user configurable. All operating modes are set up via the parameter set. Up to 100 ma can be sourced from the User +24 V output and up to 20 ma from the analog output. IP20 and IP55 IP55 with switch option +24 V DI 1 DI 2 DI 3 +10 V AI/DI 0 V AO/DO 0 V Relay contact Relay common +24 V DI 1 DI 2 DI 3 +10 V AI/DI 0 V AO/DO 0 V Relay contact Relay common 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 FWD REV 64485AEN The signal terminal block has the following signal connections: 64608AEN Terminal Signal Connection Description no. 1 +24 V +24 V ref out Ref. to activate DI1 DI3 (100 ma max.) 2 DI1 Digital input 1 Positive logic 3 DI2 / DO2 Digital input 2 / Digital output 2 4 DI3 / AI2 Digital input 3 / Analog input 2 "Logic 1" input voltage range: DC 8 30 V "Logic 0" input voltage range: DC 0 8V Positive logic (P2-33) "Logic 1" input voltage range: DC 8 30 V "Logic 0" input voltage range: DC 0 8V 0 10 V, 0 20 ma, 4 20 ma 5 +10 V +10 V ref out 24 V ref for analog input (pot supply +, 100 ma max., 1 kω min.) 6 AI / DI Analog input (12 bit) Digital input 4 0 10 V, 10 +10 V, 0 24 V, 24 +24 V "Logic 1" input voltage range: DC 8 30 V (P2-30) 7 0 V 0 V common 0 V ref for analog input (pot supply ) 8 AO / DO Analog output (8 bit) Digital output 0 10 V, 4 20 ma analog 24 V, 20 ma digital (P2-36) 9 0 V 0 V common 0 V ref for analog output 10 Relay contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 11 Relay common Relay common Catalog MOVITRAC LTP 25

n kva 3 f General specifications i Communication Interfaces P Hz 3.10.1 Key information on the control terminal Maximum input voltage on any terminal: DC 30 V All outputs are short-circuit proof Recommended potentiometer resistance: 1 k Ω Digital input response time: < 8 ms Bipolar analog input response time: < 16 ms. Resolution ±12-bit (0.025 %) Second analog input response time: < 16ms. Resolution +11-bit (0.05 %) Analog / digital output response time: < 16ms. Resolution 8-bit (0.25 %) 3.11 Communication Interfaces 3.11.1 RJ11 Communication socket The RJ11 communication socket can be used to set up RS-485 communication to the PC via UWS11A. With MOVITRAC LTP units it is possible to use this RJ11 connector to set up a MODBUS communication network. [1] [2] [3] [4] [5] [6] 57406AXX [1] RS-485 / MODBUS 1) [2] RS-485+ / internal bus 1) [3] RS-485 / internal bus 1) [4] +24 V [5] 0 V [6] RS-485+ / MODBUS 1) 1) The bit format is fixed as: 1 start bit, 8 data bits, 1 stop bit, no parity The internal bus works with 115 k Baud (bps). It can be used for drive-to-drive communication. In this case, up to 63 drives can communicate. The MODBUS RTU works between 9.6 and 115 k Baud (bps). It can be used to communicate directly with an external PLC or with a fieldbus gateway. In this case, up to 63 drives can be controlled via bus communication. 26 Catalog MOVITRAC LTP

General specifications User interface kva i P f n Hz 3 3.11.2 Infra-red/IrDA interface The optical interface, which is located next to the RJ11 connector, is mainly used for commissioning and monitoring the drive with a pocket PC. When LT shell CE is installed the pocket PC can be used to commission the drive and monitor the current status of the drive. Additionally the infra-red interface can be used to set up a master slave network. However the maximum number of slaves is limited to 2. 3.12 User interface 3.12.1 Keypad Each MOVITRAC LTP has an integrated keypad as standard, allowing drive operation and set up without any additional equipment. The keypad consists of 5 keys with the following functions: Start / Run Stop / Reset Navigate Up Down Enable running of motor Stop motor / Reset trip Press and release to display A / Hz / rpm Press and hold to enter / exit parameter edit mode Increase Parameter / Value Decrease Parameter / Value The Start / Stop buttons on the keypad are disabled when the parameters have their factory default settings. To enable the operation of the <start> / <stop> buttons on the keypad, set P-12 to 1 or 2 (see chapter "Standard parameters" on page 28). The Navigate key alone is used to gain access to the parameter edit menu. Pressing and holding this key (> 1 second) allows the user to toggle between the parameter edit menu and the real time display (where the drive operating status / running speed is displayed). By pressing this key (< 1 second) the user is able to toggle between the operating speed and operating current during drive operation. [1] [2] [4] [5] [3] [6] 54787AXX [1] Display [2] Start [3] Stop / Reset [4] Navigate [5] Up [6] Down Catalog MOVITRAC LTP 27

n kva 3 f General specifications i Parameter specifications: P Hz 3.13 Parameter specifications: 3.13.1 Standard parameters Par. Title Range Default Description P1-01 Max speed limit (Hz or rpm) P1-02 P1-09 x 5 (up to 2000 Hz max) 50.0 Hz (60 Hz) 1) 1) If the default value is 60 Hz (460 V), this is shown on the name plate as 60 Hz. Sets the maximum speed limit. Display of Hz or rpm dependent on P1-10. Maximum speed limit dependent on switching frequency: Max Limit = P2-24 / 16. P1-02 Min speed limit (Hz or rpm) 0 P1-01 0.0 Hz Minimum speed limit. Hz or rpm display depending on P1-10. P1-03 Acceleration ramp time (s) 0.0 s 3000 s 5.0 s Time to ramp from 0 to rated frequency (P1-09) P1-04 Deceleration ramp time (s) 0.0 s 3000 s 5.0 s Time to ramp from rated frequency (P1-09) to 0. If a braking resistor is not fitted the ramp time will be extended automatically to prevent over-voltage trip. P1-05 Stop mode select 0: Ramp to stop P1-06 Energy optimisation (V/f mode only) If the supply is lost and P1-05 = 0 then the drive will try to continue running by reducing 1: Coast to stop the speed of the load using the load as a 0: Ramp to stop 2: Ramp to stop generator. If P-05 = 2, the drive ramps on 2nd deceleration ramp P2-25 to stop. 0: Disable 0 When enabled, automatically reduces 1: Enable applied motor voltage on light load. P1-07 Motor rated voltage 20 V 250 V 230 V Set to motor rated voltage from nameplate. Range limited to 250 V for 230 V drives. 20 V 500 V 400 V (460 V) 1) Rated (nameplate) voltage of the motor in 20 V 600 V 575 V volts. The value is limited to 250 V for low voltage drives. Setting to 0 disables voltage compensation. P1-08 Motor rated current limit 20 % to 100 % of drive related current Drive rating Set to motor rated current from nameplate (Amps). P1-09 Motor rated frequency 25 2000 Hz 50.0 Hz Set to motor rated frequency from nameplate (Hz). (60.0 Hz) 1) Maximum limit dependent on switching frequency: Max Limit = P2-24 / 16. P1-10 Motor rated speed 0 60000 rpm 0 When not set to 0 all speed-related parameters are displayed in rpm. P1-11 Preset speed 1 P1-01 +P1-01 50 Hz (60 Hz) 1) Sets jog / preset speed at which drive runs when preset speed 1 selected via digital inputs (see P2-01). P1-12 Terminal / Keypad control of drive 0: Terminal control 1: Keypad control (fwd only) 2: Keypad control (fwd and rev) 3: Enable user PID 4: Enable MODBUS network control 0: Terminal control Set to 0 for terminal control. Set to 1 for uni-direction keypad control. Set to 2 for bi-directional keypad control. Keypad <start> key toggles between forward and reverse. User PID (feedback control) set in parameter group 3. Drive controlled via integrated MODBUS RTU interface. P1-13 Trip log Last 4 trips stored Latest 4 trips stored. Most recent displayed first. P1-14 Extended menu access code 0 30000 0 Permits access to extended menu when P1-14 = P2-37. Default access value = 101. 28 Catalog MOVITRAC LTP

General specifications Parameter specifications: kva i P f n Hz 3 3.13.2 Extended parameters Par. Description Range Default Explanation P2-01 Digital input function select 0 22 0 Defines the function of the digital inputs. P2-02 Preset speed 2 P1-01 +P1-01 0.0 Hz Sets jog / preset speed 2 P2-03 Preset speed 3 P1-01 +P1-01 0.0 Hz Sets jog / preset speed 3 P2-04 Preset speed 4 P1-01 +P1-01 0.0 Hz Sets jog / preset speed 4 P2-05 Preset speed 5 P1-01 +P1-01 0.0 Hz Sets jog / preset speed 5 P2-06 Preset speed 6 P1-01 +P1-01 0.0 Hz Sets jog / preset speed 6 P2-07 Preset speed 7 P1-01 +P1-01 0.0 Hz Sets jog / preset speed 7 P2-08 Preset speed 8 P1-01 +P1-01 0.0 Hz Sets jog / preset speed 8 P2-09 Skip frequency P1-02 P1-01 0.0 Hz Centre point of skip frequency band set up in conjunction with P2-10. P2-10 Skip frequency band 0 P1-01 0.0 Hz (disable) P2-11 Analog output / Digital output 1 Function select P2-12(h) P2-12(L) Digital output control high limit Digital output control low limit P2-13 User relay output function select 1) Analog output format refers to P2-36 Width of skip frequency band centred on frequency set in P2-09. (Digital output mode) 7 Digital output mode. Logic 1 = DC +24 V 0: Drive enabled 0: Logic 1 when drive enabled (running) 1: Drive healthy 1: Logic 1 when no fault condition exists on drive 2: Motor at target speed 2: Logic 1 when motor speed matches setpoint speed 3: Motor speed > 0 3: Logic 1 when motor runs above zero speed 4: Motor speed limit 4-6: 5: Motor torque limit Digital output enabled using level set in P2-12h and P2-12L 6: 2nd analog input limit (Analog output mode) (Analog output mode) 1) 7: Motor speed 7: Motor speed, 0 10V=0 P-01 8: Motor torque 8: Motor torque, 0 10 V = 0 200 % of motor rated torque 9: Motor power (kw) 9: Motor power, 0 10 V = 0 150 % of drive rated power 10: Motor current 10: Motor current, 0 10 V = 0 200 % of P1-08 Speed : 0 200 % (200 % = max speed) Torque : 0 200 % (200 % = rated torque) PID feedback : 0 200 % (200 % = max 2nd analog input) 100 % Digital output state set to logic 1 when selected value in P2-11 larger than this limit. Limit in P2-12 relates to speed if P2-11 = 4, to motor torque if P2-11 = 5 or to the PID feedback value (2nd analog input) if P2-11 = 6. 0 P2-12(h) 100 % Digital output state back to logic 0 when selected value in P2-11 less than or equal to this limit. (P2-11 = 4,5 or 6) 0: Drive enabled 1 If P2-15 = 0 (Normally Open), the relay 1: Drive healthy contacts are closed when the selected condition is fulfilled. 2: Motor at target speed If P2-15 = 1 (Normally Closed), the relay 3: Motor speed > 0 contacts are open when the selected condition is fulfilled. 4: Motor speed limit 5: Motor torque limit 6: 2nd analog input limit Catalog MOVITRAC LTP 29

n kva 3 f General specifications i Parameter specifications: P Hz Par. Description Range Default Explanation P2-14(h) P2-14(L) User relay output control high limit User relay output control low limit Speed : 0 200 % (200 % = max speed) Torque : 0 200 % (200 % = rated torque) PID feedback : 0 200 % (200 % = max 2nd analog input) 100 % User relay output closes (P2-15=0) when selected value in P2-13 larger than this limit. Limit in P2-14 relates to speed if P2-13 = 4, to motor torque if P2-13 = 5 or to the PID feedback value (2nd analog input) if P2-13 = 6. 0 P2-14(h) 100 % Digital output state back to logic 0 when selected value in P2-13 less than or equal to this limit. (P2-13 = 4,5 or 6) P2-15 Relay output mode 0: Normally Open (NO) 0 (NO) The drive must be powered up for the relay 1: Normally Closed (NC) contacts to be closed. P2-16 Zero Speed holding time 0 60 s P2-17 Start mode select Edgr-r Close digital input 1 after power up to start drive P2-18 Spin Start Enable (V/f mode only) Auto-0 Auto- 1 5 Drive runs whenever digital input 1 is closed As Auto-0, except 1..5 attempts to restart after a trip 0.2 s Determines the time for which the zero speed is held on the output before disabling the drive. Auto-0 When set to Edge-r, if drive is powered up with digital Input 1 closed (enabled), drive will not run. The switch (digital input 1) must be opened and closed after power up or after a clearing a trip for the drive to run. When set to Auto-0, drive will run whenever digital input 1 is closed (if not tripped). Auto-1 5 makes 1 5 attempts to automatically restart after a trip (20 s between attempts in default). Drive must be powered down to reset the counter. 0: Disable 0 When enabled, drive detects motor speed 1: Enable and starts driving the motor from this speed (the motor speed can be in both directions: forward or reverse). A short delay of approx. 1 s will result after enabling the drive before speed is detected. This function only works when parameter P4-01 = 2. P2-19 Keypad restart mode 0: Minimum speed 1 If set to 0 or 2, drive will always start from 1: Previous speed minimum speed. If set to 1 or 3, drive ramps up to the operating 2: Min-speed (Auto-r) speed prior to the last STOP com- 3: Previous speed (Auto-r) mand. If set to 2 and 3, the status of digital input 1 controls drive to start or stop. The start and stop button will not work in this case. P2-20 Standby mode 0: Disable 1 60 s 0.0 s If P2-20 > 0, drive enters standby mode (disables output) if minimum speed is maintained for the time specified in P2-20. If P2-16 > 0, this function is disabled. P2-21 Display scaling factor 0.000 30.000 0.000 Disabled if set to zero. The variable selected in P2-22 is multiplied by this factor and displayed as a real-time value on the drive, in addition to speed, current and power. P2-22 Display scaling source 0: 2nd analog input 0 Selects the variable to be scaled by the 1: Motor speed factor set in P2-21. 2: Motor torque 3: Motor current 30 Catalog MOVITRAC LTP

General specifications Parameter specifications: kva i P f n Hz 3 Par. Description Range Default Explanation P2-23 Brake circuit enable 0: Disable 0 Enables the internal brake chopper. 1: Enable + lo power Overload protection in software when set to 1 or 2. See rating tables for resistor sizing 2: Enable + hi power guidelines. 3: Enable, no protection P2-24 Effective switching S1, S2 230 V, 4 32 khz 16 khz Effective power stage switching frequency. frequency X1: higher switching frequency means less S2 400 V, 4 32 khz 8 khz noise development on the motor but higher S3, S4 400 V, 4 24 khz 4 khz losses at output stage. S5, S6 400 V, 4 16 khz 4 khz Auto "Auto" selects minimum possible switching frequency for the speed range selected to minimize losses in spindle applications. (P2-24 must be 16 x P1-01 or greater.) P2-25 Second deceleration ramp time P2-26 MODBUS communication baudrate P2-27 Drive communication address 0 s 3000 s 0.0 s Selected automatically on mains loss if P1-05 = 2. Can also be selected via digital inputs during operation. t9.6, t19.2, t38.4, t57.6, t115.2 r9.6, r19.2, r38.4, r57.6, r115.2 0 Kbaud MODBUS RTU serial data link communication baudrate. A t suffix indicates the drive will trip if communication with the network master is lost, after the time period set in P6-08. An r suffix indicates that the drive will ramp to stop if communication with the network master is lost, after the time period set in P6-08. 0: Disable 1 Distinct drive address used for all drive 1 63: Communication address serial communications. P2-28 Master / Slave mode select 0: Slave mode 0 When in Master mode, the drive transmits 1: Master mode its operational status via the serial data link. Used to control slave drives via the serial link. P2-27 must be 1 for Master mode. P2-29 Digital speed reference preset scaling factor P2-30 Bipolar analog input format 0 24 V 0 10 V 10 +10 V 24 +24 V P2-31 Bipolar analog input scaling 0 500 %, steps of 0.1 % 100.0 % The digital speed reference input to the drive is scaled by this factor when P2-35 = 1. Operates on references originating from the serial data link. Can be used as an electronic gearbox for Master / Slave applications. 0 24 V Configures the analog input format to match the reference signal connected to terminal 6. Only voltage signals can be directly connected, ma reference signals require an external resistor connection. 0 500 % 100.0 % Scales the analog input by this factor. Set to 200 % to give full speed range control with 0 5 V input (whenp2-30=0 10V). P2-32 Bipolar analog input offset 500 % +500 % 0.0 % Sets the offset from zero at which speed starts to ramp up. Value is % of the full scale input voltage. P2-33 2nd analog input format 0 / 24 V (digital input) 0 10 V, 4 20 ma, 0 20 ma 0 / 24 V Determines the format of the 2nd analog input.selecting 0 / 24 V sets up the input as a digital input. P2-34 2nd analog input scaling 0 500 % 100.0 % Scales the 2nd analog input by the factor set in this parameter. Catalog MOVITRAC LTP 31

n kva 3 f General specifications i Parameter specifications: P Hz Par. Description Range Default Explanation P2-35 Digital speed reference scaling control 0: Disabled (no scaling) 0 Only active in keypad mode 1: Scaled by P2-29 2: Scaled by P2-29, bipolar with analog input added as offset 3: Scaled by P2-29 and by bipolar analog input P2-36 Analog output format 0 10V, 4 20mA, 10 0V, 20 4mA P2-37 Extended menu access code define (P1-12 = 1 or 2) and Master / Slave mode. 1: Actual speed = digital speed P2-29 2: Actual speed = (digital speed P2-29) + bipolar analog reference 3: Actual speed = (digital speed P2-29) bipolar analog reference 0 10 V Determines the analog output format. Min load impedance in voltage mode: 1k Ω Max load impedance in current mode: 1k Ω 0 9999 101 Defines the extended menu access code used in P1-14. P2-38 Parameter Lock 0: Unlocked 0 When locked, all parameter changes are 1: Locked prevented. P2-39 Hours run clock 0 99999 hours Read only P2-40 Drive type / rating Read only Indicates the number of hours the drive has been running since new. Indicates drive power rating, type code and voltage rating. 32 Catalog MOVITRAC LTP

General specifications Parameter specifications: kva i P f n Hz 3 3.13.3 User feedback control (PID control) These parameters are not available in drives with MODBUS software (-xm). Par. Description Range Default Explanation P3-01 Proportional gain 0.1 30.0 2 PID Controller Proportional Gain. Higher values provide a greater change in the drive output frequency in response to small changes in the feedback signal. Too high a value can cause instability. P3-02 Integral time constant 0.0 s 30.0 s 1 s PID Controller Integral Time. Higher values provide a more damped response for systems where the overall process responds slowly. P3-03 Differential time constant 0.00 s 1.00 s 0.00 Can be set to zero (disabled) for most applications. P3-04 PID operating mode 0: Direct 1: Inverse P3-05 PID Setpoint / reference select 0: Digital 1: Analog 0 Direct operation: Motor speed increases with an increase in the feedback signal. Inverse operation: Motor speed decreases with an increase in the feedback signal. 0 Sets the source for the PID reference / setpoint. 0: P3-06 is used 1: Bipolar analog input is used P3-06 PID digital reference 0 100 % 0.0 % Sets the preset digital PID reference / setpoint. P3-07 PID controller high limit output P3-08 PID controller low limit output P3-09 PID output limit / function control P3-10 PID feedback source select P3-08 100 % 100 % Limits the maximum value output from the PID controller. 0 P3-07 0.0 % Limits the minimum output from the PID controller. 0: Digital output limits 1: Analog upper limit 2: Analog lower limit 3: PID output + biploar analog input reference 0: 2nd analog input 1: Bipolar analog input 0 0: PID output range limited by P3-07 & P3-08 1: PID maximum output limited by signal applied to the bipolar analog input. 2: PID minimum output limited by signal applied to the bipolar analog input 3: PID output added to speed reference applied to the bipolar analog input 0 Selects the source of the PID feedback signal. Catalog MOVITRAC LTP 33

n kva 3 f General specifications i Parameter specifications: P Hz 3.13.4 High performance motor control Par. Description Range Default Explanation P4-01 Control mode 0: Speed control (vector) 1: Torque control (vector) 2: Speed control (V/f) P4-02 Motor parameter auto-tune 0: Disable 1: Enable P4-03 Speed controller Proportional gain P4-04 Speed controller Integral time constant 0 4096 (internal value) Drive rating P4-05 Motor factor power 0.50 0.99 Drive rating P4-06 Torque reference select 0: Preset value 1: Bipolar analog input 2: 2nd analog input 3: MODBUS ref P4-07 Torque reference preset value P4-08 Minimum torque reference limit P4-09 V/f characteristic adjustment frequency P4-10 V/f characteristic adjustment voltage 2 Whenever changing control mode, ensure that an Auto-tune (P4-02) is always carried out for best motor performance. Set to 0 for speed control with variable torque limits. 0 When set to 1, the drive immediately carries out a static (non-rotating) motor parameter measurement operation to configure the motor parameters. P1-07, P1-08 and P1-09 must be set correctly according to the motor nameplate before enabling this function. Auto-tune runs automatically on first enable after parameter default operation and P1-08 has been changed. No hardware enable is required. Too high a value can cause instability. Only available in vector mode. 0.000 1.000 s 0.05 s Higher value gives slower, more damped response. Only available in vector mode. Motor nameplate power factor (cos Φ). Required for all vector control modes. 0 Used when in vector control mode to set a maximum torque limit. 0 200 % 200.0 % Preset value used when P4-06 = 0. 100 % is rated motor torque. 0 150 % 0.0 % Defines the minimum limit for output motor torque 0 P1-09 0.0 Hz Sets the frequency at which the adjustment voltage (P4-10) is applied. 0 P1-07 0 Sets the motor voltage to this value at the frequency set in P4-09. 34 Catalog MOVITRAC LTP

General specifications Selection of Parameter P2-01, Digital Input Function kva i P f n Hz 3 3.14 Selection of Parameter P2-01, Digital Input Function The functionality of the digital inputs within the MOVITRAC LTP is user programmable, allowing the user to select the functions required for the application. The following tables define the functions of the digital inputs depending on the value of parameter P1-12 (Terminal / keypad control) and P2-01 (Selection of digital input function). 3.14.1 Selection table if P1-12 = 0 (Terminal mode) P2-01 Digital input 1 (DI1) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments / Preset value 0 O: Stop (Disable) 1 O: Stop (Disable) 2 O: Stop (Disable) 3 O: Stop (Disable) 4 O: Stop (Disable) 5 O: Stop (Disable) 6 O: Stop (Disable) 7 O: Stop (Disable) C: Run Forward 8 O: Stop (Disable) C: Run Forward 9 O: Stop (Disable) C: Run Forward O: Analog input C: Preset speed 1, 2 O: Preset speed 1 C: Preset speed 2 O: Preset speed 1 C: Preset speed 2 O: Preset speed 1, 2 C: Preset speed 3 Bipolar analog input O: Preset speed 1,2,3 C: Preset speed 4 DI3 selects speed if DI2 is closed Open Open Open Preset speed 1 Closed Open Open Preset speed 2 Open Closed Open Preset speed 3 Closed Closed Open Preset speed 4 Open Open Closed Preset speed 5 Closed Open Closed Preset speed 6 Open Closed Closed Preset speed 7 Closed Closed Closed Preset speed 8 O: Forward C: Reverse O: Forward C: Reverse O: Forward C: Reverse O: Forward C: Reverse O: Stop (Disable) C: Run Reverse O: Stop (Disable) C: Run Reverse O: Stop (Disable) C: Run Reverse O: Analog input C: Preset speed 1 2nd analog input Bipolar analog input Bipolar analog input P4-06 = 0 or 1 speed reference at 2nd analog input P4-06 = 2 bipolar input is speed reference, 2nd analog input is torque ref. P2-36 sets format of DI3 Open Open Preset speed 1 Closed Open Preset speed 2 Open Closed Preset speed 3 Closed Closed Preset speed 4 External trip input: O: Trip C: OK O: Analog input C: Preset speed 1 O: Preset speed 1 C: Analog input Bipolar analog input Bipolar analog input Bipolar analog input Connect an external PTC motor thermistor or similar to DI3 Open Open Preset speed 1 Closed Open Preset speed 2 Open Closed Preset speed 3 Closed Closed Preset speed 4 Catalog MOVITRAC LTP 35

kva 3 f General specifications Selection of Parameter P2-01, Digital Input Function i n P Hz P2-01 Digital input 1 (DI1) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments / Preset value 10 O: Stop (Disable) C: Run Forward 11 O: Stop (Disable) 12 O: Stop (Disable) 13 Normally Open (NO) Momentarily close to run forward 14 Normally Open (NO) Momentarily close to run forward 15 O: Stop (Disable) 16 O: Stop (Disable) 17 Normally Open (NO) Momentarily close to run forward 18 O: Stop (Disable) 19 O: Stop (Disable) 20 O: Stop (Disable) 21 O: Stop (Disable) 22 O: Stop (Disable) O: Stop (Disable) C: Run Reverse O: Analog input C: Preset speed 1 O: Preset speed 1 C: Analog input Normally Closed (NC) Momentarily open to run Normally Closed (NC) Momentarily open to stop O: Forward C: Reverse O: Forward C: Reverse Normally Closed (NC) Momentarily open to stop External trip input: O: Trip C: OK External trip input: O: Trip C: OK External trip input: O: Trip C: OK O: Analog input C: Preset speed 1 Normally Open (NO) Momentarily close to run reverse O: Decel ramp 1 C: Decel ramp 2 O: Decel ramp 1 C: Decel ramp 2 Normally Open (NO) Momentarily close to run reverse Bipolar analog input Bipolar analog input Bipolar analog input Bipolar analog input Bipolar analog input Bipolar analog input O: Preset speed 1 C: Preset speed 2 O: Preset speed 1 C: Keypad mode Connect an external PTC motor thermistor or similar to DI3 Connect an external PTC motor thermistor or similar to DI3 Connect an external PTC motor thermistor or similar to DI3 Up and Down buttons can be used to set the speed when analog input is set to keypad mode. Open Open O: Terminal mode Preset speed 1 Closed Open C: Keypad mode Preset speed 2 Open Closed Preset speed 3 Closed Closed Preset speed 4 O: Analog input C: 2nd analog input 2nd digital output (+24 V) 2nd digital output (+24 V) 2nd digital output (+24 V) 2nd analog input O: Analog input C: Preset speed 1 O: Forward C: Reverse External trip input: O: Trip C: OK Bipolar analog input Bipolar analog input Bipolar analog input Bipolar analog input 2nd digital output shows drive healthy 2nd digital output shows drive healthy 2nd digital output shows drive healthy NOTE When P2-01 = 20, the 2nd digital input is configured as an output, which outputs +24 V when the drive is healthy. If the drive is not healthy, the output will be 0 V. When connecting a motor thermistor, connect it between terminals 1 and 4. Set P2-01 to 6, 10, 11, 12 or 22 (uses external trip input). 36 Catalog MOVITRAC LTP

General specifications Selection of Parameter P2-01, Digital Input Function kva i P f n Hz 3 3.14.2 Selection table if P1-12 = 1 or 2 (Keypad mode) P2-01 Digital input 1 (DI1) 0 O: Stop (Disable) 1 O: Stop (Disable) 2 O: Stop (Disable) 3 9, 13, 14, 16 1) O: Stop (Disable) 10 O: Stop (Disable) 11 O: Stop (Disable) 12 O: Stop (Disable) 15 O: Stop (Disable) 17 O: Stop (Disable) 18 O: Stop (Disable) 19 O: Stop (Disable) 20, 21 O: Stop (Disable) 22 O: Stop (Disable) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments / Preset value C: Increase speed C: Decrease speed No effect Close DI2 & DI3 simultaneously to start drive. C: Increase speed External trip input: O: Trip C: OK C: Increase speed O: Digital speed ref C: Preset speed 1 C: Decrease speed Close DI2 & analog input simultaneously to start drive. Connect an external PTC motor thermistor or similar to DI3. Analog input > 5 V reverses rotation. C: Increase speed C: Decrease speed O: Forward C: Reverse O: Digital speed ref C: Analog input O: Digital speed ref C: Preset speed 1 O: Preset speed 1 C: Analog input O: Digital speed ref C: Preset speed 1 O: Digital speed ref C: Analog input O: Digital speed ref C: Preset speed O: Digital speed ref C: 2nd analog input 2nd digital output: (+24 V) 2nd digital output: (+24 V) External trip input: O: Trip C: Run External trip input: O: Trip C: Run External trip input: O: Trip C: Run O: Decel ramp 1 C: Decel ramp 2 O: Digital / analog speed C: Preset speed 1 Analog speed ref Analog input > 5 V reverses rotation. Analog input > 5 V reverses rotation. Analog input > 5 V reverses rotation. Analog speed ref Reverse operation only available in P1-12 = 2. Close DI2 & DI3 simultaneously to start drive. Connect an external PTC motor thermistor or similar to DI3. Connect an external PTC motor thermistor or similar to DI3. Connect an external PTC motor thermistor or similar to DI3. DI3 overrides DI2. Open Open Preset speed 1 Closed Open Preset speed 2 Open Closed Preset speed 3 Closed Closed Preset speed 4 No effect O: Digital speed ref C: Preset speed 1 External trip input: O: Trip C: Run Analog input > 5 V reverses rotation. Analog input > 5 V reverses rotation. Analog input > 5 V reverses rotation. 2nd digital output shows drive healthy. Connect an external PTC motor thermistor or similar to DI3. 2nd digital output shows drive healthy. 1) In addition to the speed being set using the pushbuttons on the front of the drive, these settings allow the speed to be controlled remotely using remote pushbuttons connected to digital inputs 1, 2 and 3. When P2-01 = 17 or 18, keypad mode is selected from within terminal mode (see page 35). For this reason, the remaining digital inputs have no effect. When P2-19 = 2 or 3 in keypad mode, the drive start and stop is controlled from the hardware enable input (terminal 2). In this case, the <start> / <stop> buttons are not required and therefore have no effect. Reverse rotation control by analog input only works when P1-12 = 2. When connecting a motor thermistor, connect it between terminals 1 & 4 and set P2-01 to 6, 10, 11, 12 or 22 (uses external trip output). Catalog MOVITRAC LTP 37

kva 3 f General specifications Selection of Parameter P2-01, Digital Input Function i n P Hz Example: Motor potentiometer function - crane applications To run the motor potentiometer function, the following parameters must be set: P1-02 = Minimum speed (ex. 100 rpm) P1-03 = Acceleration time (ex. 10 s) P1-04 = Deceleration time (ex. 10 s) P1-11 = Safety end limit speed set point (ex. 300 rpm) P1-12 = 1 (keypad mode) P2-01 = 2 (digital input function) P2-19 = 2 (auto restart, minimum speed) 1 2 3 4 5 6 7 [1] [2] [3] [4] 57211AXX [1] Enable / Ramp down [2] Ramp up [3] Preset speed 1 [4] Change direction (forward / reverse) 38 Catalog MOVITRAC LTP

General specifications Selection of Parameter P2-01, Digital Input Function kva i P f n Hz 3 3.14.3 Selection table if P1-12 = 3 (User PID mode) The following table defines the function of the digital inputs when the drive is in User PID control mode (set using P1-12 = 3). P2-01 Digital input 1 (DI1) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments 0 10, 13 18 O: Stop (Disable) 11 O: Stop (Disable) 12 O: Stop (Disable) 17 O: Stop (Disable) 19 O: Stop (Disable) 20, 21 O: Stop (Disable) 22 O: Stop (Disable) No effect No effect Bipolar analog input O: PID control C: Preset speed 1 O: Preset speed 1 C: PID control O: PID control C: Analog input O: PID control C: 2nd analog input 2nd digital output: (+24 V) 2nd digital output: (+24 V) External trip input: O: Trip C: Run External trip input: O: Trip C: Run No effect 2nd analog input No effect External trip input: O: Trip C: Run Connect an external PTC motor thermistor or similar to DI3. P3-10 = 1 for external trip. Connect an external PTC motor thermistor or similar to DI3. P3-10 = 1 for external trip. 2nd digital output shows drive healthy. Connect an external PTC motor thermistor or similar to DI3. P3-10 = 1 for external trip. 2nd digital output shows drive healthy. Catalog MOVITRAC LTP 39

kva 3 f General specifications Selection of Parameter P2-01, Digital Input Function i n P Hz 3.14.4 Selection table if P1-12 = 4 (MODBUS control) The following table defines the function of the digital inputs when the drive is in MODBUS control mode (set using P1-12 = 4). P2-01 Digital input 1 (DI1) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments 0, 1, 2, 4 6 9, 13, 15, 18 O: Stop (Disable) 3 O: Stop (Disable) 5 O: Stop (Disable) 10 O: Stop (Disable) 11 O: Stop (Disable) 12 O: Stop (Disable) 17 O: Stop (Disable) 19 O: Stop (Disable) 20, 21 O: Stop (Disable) 22 O: Stop (Disable) No effect No effect No effect O: Forward C: Reverse O: Master speed ref C: Preset speed 1 O: Master speed ref C: Digital speed ref O: Master speed ref C: Preset speed 1 O: Master speed ref C: Analog speed ref O: Master speed ref C: Analog speed ref O: Master speed ref C: 2nd analog input 2nd digital output: (+24 V) 2nd digital output: (+24 V) O: Master speed ref C: Preset speed 1 No effect Open Open Preset speed 1 Closed Open Preset speed 2 Open Closed Preset speed 3 Closed Closed Preset speed 4 External trip input: O: Trip C: Run External trip input: O: Trip C: Run External trip input: O: Trip C: Run O: Master / analog input speed ref C: Preset speed 1 No effect No effect Analog speed reference Analog speed reference 2nd analog input No effect O: Master speed ref C: Preset speed 1 External trip input: O: Trip C: Run No effect No effect Connect an external PTC motor thermistor or similar to DI3. Connect an external PTC motor thermistor or similar to DI3. Connect an external PTC motor thermistor or similar to DI3. If DI3 is closed, DI2 has no effect. 2nd digital output shows drive healthy. Connect an external PTC motor thermistor or similar to DI3. 2nd digital output shows drive healthy. NOTE If P2-19 = 2 or 3, the drive can only be started or stopped by closing or opening digital input 1. If P2-19 = 0 or 1, the start / stop signal must be set via bus and digital input 1. 40 Catalog MOVITRAC LTP

General specifications Selection of Parameter P2-01, Digital Input Function kva i P f n Hz 3 3.14.5 Real-time monitoring parameters Parameter group zero provides access to internal drive parameters for monitoring purposes. These parameters cannot be adjusted. Par. Description Display range Explanation P0-01 Bipolar analog input value 100 % +100 % 100 % = max input voltage P0-02 2nd analog input value 0 100 % 100 % = max input voltage P0-03 Speed controller reference 500 % +500 % 100 % = Base frequency (P1-09) P0-04 Digital speed ref (digi pot) P1-01 +P1-01 Speed displayed in Hz / rpm P0-05 Torque controller reference 0 200 % 100 % = motor rated torque P0-06 User PID ref input 0 100 % PID controller reference value P0-07 User PID feedback 0 100 % PID controller feedback value P0-08 User PID error input 0 100 % Reference Feedback P0-09 User PID P-term 0 100 % Proportional component P0-10 User PID I-term 0 100 % Integral component P0-11 User PID D-term 0 100 % Differential component P0-12 User PID output 0 100 % Combined output P0-13 Output Torque 0 200 % 100 % = motor rated torque P0-14 Magnetizing current A rms Magnetizing current in A rms P0-15 Rotor current A rms Rotor current in A rms P0-16 Field strength 0 100 % Magnetic field strength P0-17 Stator resistance Ohm [Ω] Phase - Phase stator resistance P0-18 Stator inductance H Stator inductance in Henry P0-19 Rotor resistance Ohm [Ω] Calculated rotor resistance P0-20 DC bus voltage V DC Internal DC bus voltage P0-21 Drive temperature C Internal drive temperature P0-22 Supply voltage L1 L2 V rms, ph-ph Phase phase supply voltage P0-23 Supply voltage L2 L3 V rms, ph-ph Phase phase supply voltage P0-24 Supply voltage L3 L1 V rms, ph-ph Phase phase supply voltage P0-25 Estimated Rotor speed Hz or rpm Applies to vector modes only P0-26 kwh meter 0.0 999.9 kwh Cumulative energy consumption P0-27 MWh meter 0.0 60000 MWh Cumulative energy consumption P0-28 Software ID, IO processor e.g. 1.00, 493F Version number and check sum P0-29 Software ID, Motor control e.g. 1.00, 7A5C Version number and check sum P0-30 Drive serial number 000000 999999 00-000 99-999 Unique drive serial number e.g. 540102 / 24 / 003 Catalog MOVITRAC LTP 41

Accessories 4 Braking resistors 4 Accessories 4.1 Braking resistors 4.1.1 Braking resistor circuit MOVITRAC LTP units have a built in braking transistor which can be used with an external braking resistor to convert re-generated energy from the motor into thermal energy. This braking circuit is generally needed for applications with a fast deceleration ramp or with a high inertia load. SEW also recommends protecting the wire and grid resistors against overload using a bimetallic relay as shown below. The relay output must open up the supply voltage to the MOVITRAC LTP unit. It must not open up the connection from the braking resistor to the MOVITRAC LTP unit. With SEW-EURODRIVE flat-type braking resistors and any other overload protected braking resistors, the bimetallic relay is not required. The illustration below shows the wiring diagram for the braking resistor connection. U V W + BR F16 BW... affects K11 Figure 2: Wiring diagram for braking resistor connection 57643AEN For some inverter / resistor combinations 2 braking resistors with the same value must be connected in parallel. In this case, the trip current must be set on the bimetallic relay to twice the value of I F entered in the following tables. For the BW...-T and BW...-P braking resistors the temperature switch / overcurrent relay must be connected in series. 42 Catalog MOVITRAC LTP

Accessories Braking resistors 4 4.1.2 Minimum braking resistor values MOVITRAC LTP 230 V 400 V 525 V 575 V 0.75 kw 47 47 1.5 kw 33 47 47 2.2 kw 22 47 47 3.0 kw 15 4.0 kw 15 33 47 5.5 kw 15 22 47 7.5 kw 6 22 22 11 kw 6 22 22 15 kw 6 22 22 18.5 kw 6 12 22 kw 3 12 12 30 kw 3 12 12 37 kw 3 12 45 kw 3 6 12 55 kw 3 6 6 75 kw 3 6 6 90 kw 3 6 6 110 kw 6 6 132 kw 6 6 160 kw 6 6 Catalog MOVITRAC LTP 43

Accessories 4 Braking resistors 4.1.3 Flat design braking resistors The flat-design resistors have degree of protection IP54 and are equipped with internal thermal overload protection (cannot be replaced). Depending on their type, you can install the resistors as follows: With support rail mounting FHS or submounting FKB under the heat sink. The braking resistors in the submounting do not achieve the specified CDF power. The FHS and FKB options are only suitable for the BW027-003 and BW072-003 braking resistors. Attach to a mounting rail using a BS touch guard. Caution: The load capacity applies for a horizontal mounting position [2]. Values are reduced by 10 % for a vertical mounting position [1]. [1] [2] 64745AXX Braking resistor type BW027-003 BW027-005 BW047-003 BW047-005 BW072-003 BW072-005 BW100-005 Part number 826 949 1 826 950 5 826 265 9 826 268 3 826 058 3 826 060 5 826 269 1 100 % CDF 50 % CDF 25 % CDF 12 % CDF 6 % CDF 230 W 310 W 410 W 550 W 980 W 450 W 610 W 840 W 1200 W 2360 W 250 W 330 W 430 W 580 W 1050 W 450 W 610 W 840 W 1200 W 2360 W 230 W 310 W 420 W 580 W 1000 W 450 W 610 W 840 W 1200 W 2360 W 450 W 610 W 840 W 1200 W 2360 W Resistance value R BW 27 Ω ±10 % 47 Ω ±10 % 72 Ω ±10 % 100 Ω ±10 % Trip current I F 1.0 A 1.4 A 0.8 A 1.2 A 0.6 A 1.0 A 0.8 A Ambient temperature ϑ U 20 C to +45 C 44 Catalog MOVITRAC LTP

Accessories Braking resistors 4 4.1.4 Wire and grid resistors Perforated sheet cover (IP20) open towards the mounting surface The short-time load capacity of the wire and grid resistors is greater than in the flattype braking resistors SEW-EURODRIVE recommends also protecting the wire and grid resistors against overload using a bimetallic relay. Set the trip current to the value I F in the table. Do not use any electronic or electromagnetic fuses since even the brief excess currents which are still permitted may cause them to trip. The surfaces of the resistors get very hot if loaded with P N. Bear this aspect in mind when selecting the installation location. Braking resistors are therefore mounted on the control cabinet roof. Assignment to AC 230 V units Braking resistor type BW... BW039-003 BW039-006 BW039-012 BW027-006 BW027-012 Part number 821 687 8 821 688 6 821 689 4 822 422 6 822 423 4 Braking resistor type BW...-T BW039-012-T BW039-026-T BW018-015-P BW018-035-T Part number 1820 136 9 1820 415 5 1820 416 3 1820 138 5 Continuous braking power (100% cdf) 0.3 kw 0.6 kw 1.2 kw 2.6 kw 0.6 kw 1.2 kw 1.5 kw 3.5 kw Load capacity 50 % cdf 1) 0.5 kw 1.1 kw 2.1 kw 4.6 kw 1.1 kw 2.1 kw 2.5 kw 5.9 kw at 25 % cdf 12 % cdf 6 % cdf 1.0 kw 1.8 kw 2.8 kw 1.9 kw 3.6 kw 5.7 kw 3.8 kw 6.0 kw 2) 6.0 kw 2) 6.0 kw 2) 6.0 kw 2) 6.0 kw 2) 1.9 kw 3.6 kw 5.7 kw 3.8 kw 7.2 kw 8.7 kw 2) 4.5 kw 6.7 kw 11.4 kw 10.5 kw 13.0 kw 2) 13.0 kw 2) Observe regenerative power limit of the inverter! (= 150 % of the recommended motor power technical data) Resistance value R BW 39 Ω ±10 % 27 Ω ±10 % 18 Ω ±10 % Trip current (of F16) I F 2.7 A RMS 3.9 A RMS 5.5 A RMS 8.1 A RMS 4.7 A RMS 6.6 A RMS 9.1 A RMS 13.9 A RMS Design Wire resistor Grid resistor Connections / tightening torque Degree of protection Ceramic terminals 2.5 mm 2 (AWG12) / 0.5 Nm IP20 (when installed) M8 stud / 6Nm Ambient temperature ϑ U 20 to +40 C Type of cooling KS = Self-cooling For MOVITRAC LTP (recommended) 0015/0022 0022/0030 0030 0055 3) 1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T D 120 s. 2) Physical power limit due to DC link voltage and resistance value. 3) When connected in parallel, the load capacity and trip current are doubled. Catalog MOVITRAC LTP 45

Accessories 4 Braking resistors Braking resistor type BW...-T/-P BW018-075-T BW915-T BW012-025-P BW012-050-T BW012-100-T BW106-T BW206-T Part number 1820 139 3 1820 413 9 1820 414 7 1820 140 7 1820141 5 1820 083 4 1820 412 0 Continuous braking power (100% cdf) 7.5 kw 15.6 kw 2) 2.5 kw 5.0 kw 10 kw 13.5 kw 18 kw Load capacity 50 % cdf 1) 12.7 kw 15.6 kw 2) 4.2 kw 8.5 kw 17 kw 23 kw 30.6 kw at 25 % cdf 12 % cdf 6 % cdf 13.0 kw 2) 13.0 kw 2) 13.0 kw 2) 15.6 kw 2) 15.6 kw 2) 15.6 kw 2) 7.5 kw 11.2 kw 19.0 kw 15.0 kw 19.6 kw 2) 19.6 kw 2) 19.6 kw 2) 19.6 kw 2) 19.6 kw 2) 39.2 kw 2) 39.2 kw 2) 39.2 kw 2) 39.2 kw 2) 39.2 kw 2) 39.2 kw 2) Observe regenerative power limit of the inverter! (= 150 % of the recommended motor power technical data) Resistance value R BW 18 Ω ±10 % 15 Ω ±10 % 12 Ω ±10 % 6 Ω ±10 % Trip current (of F16) I F 20.4 A RMS 32.6 A RMS 14.4 A RMS 20.4 A RMS 28.8 A RMS 47.4 A RMS 54.7 A RMS Design Grid resistor Connections / tightening torque Degree of protection M8 stud / 6Nm IP20 (when installed) Ambient temperature ϑ U 20 +40 C Type of cooling KS = Self-cooling For MOVITRAC LTP (recommended) 0030 0055 3) 0075 0185 0075 0900 3) 1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T D 120 s. 2) Physical power limit due to DC link voltage and resistance value. 3) When connected in parallel, the load capacity and trip current are doubled. Assignment to AC 400 575 V units Braking resistor type BW... BW147 BW247 BW347 BW039-012 Part number 820 713 5 820 714 3 820 798 4 821 689 4 Braking resistor type BW...-T BW147-T BW247-T BW347-T BW039-012-T BW039-026-T BW039-050-T Part number 1820 134 2 1820 084 2 1820 135 0 1820 136 9 1820 415 5 1820 137 7 Continuous braking power (100% cdf) Load capacity 50 % cdf 1) at 25 % cdf 12 % cdf 6 % cdf 1.2 kw 2.2 kw 3.8 kw 7.2 kw 11 kw 2.0 kw 3.6 kw 6.4 kw 12 kw 19 kw 4.0 kw 7.2 kw 12.8 kw 20 kw 2) 20 kw 2) 1.2 kw 2.1 kw 3.8 kw 7.2 kw 11.4 kw 2.6 kw 4.7 kw 8.3 kw 15.6 kw 24.0 kw 2) Observe regenerative power limit of the inverter! (= 150 % of the recommended motor power technical data) Resistance value R BW 47 Ω ±10 % 39 Ω ±10 % 5.0 kw 8.5 kw 15.0 kw 24.0 kw 2) 24.0 kw 2) Trip current (of F16) I F 5A RMS 6.5 A RMS 9.2 A RMS 5.5 A RMS 8.1 A RMS 11.3 A RMS Design Wire resistor on ceramic core Grid resistor Connections / tightening torque Ceramic terminals 2.5 mm 2 (AWG13) / 0.5 Nm BW347-T: Ceramic terminals 10 mm 2 (AWG18) / 1.6 Nm Degree of protection IP20 (when installed) Ambient temperature ϑ U 20 +40 C Type of cooling KS = Self-cooling For MOVITRAC LTP (recommended) 0040/0055 0055 0150 1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T D 120 s. 2) Physical power limit due to DC link voltage and resistance value. M8 stud / 6Nm 46 Catalog MOVITRAC LTP

Accessories Braking resistors 4 Braking resistor type BW...- BW012-025 Part number 821 680 0 Braking resistor type BW...-T/-P BW012-025-P BW012-050T BW012-100-T BW106-T BW206-T Part number 1820 414 7 1820 140 7 1820 141 5 1820 083 4 1820 412 0 Continuous braking power (100% cdf) Load capacity 50 % cdf 1) at 25 % cdf 12 % cdf 6 % cdf 2.5 kw 4.2 kw 7.5 kw 11.2 kw 19.0 kw 5.0 kw 8.5 kw 15.0 kw 22.5 kw 38.0 kw 10 kw 17 kw 30 kw 45 kw 76 kw 13.5 kw 23 kw 40 kw 61 kw 102 kw Observe regenerative power limit of the inverter! (= 150 % of the recommended motor power technical data) Resistance value R BW 12 Ω ±10 % 6 Ω ±10 % 18 kw 30.6 kw 54 kw 81 kw 136.8 kw Trip current (of F16) I F 14.4 A RMS 20.4 A RMS 28.8 A RMS 47.4 A RMS 54.7 A RMS Design Grid resistor Connections / tightening torque Ceramic terminals 2.5 mm 2 (AWG13) / 0.5 Nm BW012-025-P: Terminals 4 mm 2 (AWG12) / 1 Nm Degree of protection IP20 (when installed) Ambient temperature ϑ U 20 +40 C Type of cooling KS = Self-cooling For MOVITRAC LTP (recommended) 0185 0370 1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T D 120 s. 2) When connected in parallel, the load capacity and trip current are doubled. Bolt M8 / 6 Nm 0450 1600 2) Technical data of the braking resistor BW...-T / BW...-P BW...-T / BW...-P Connection cross section for signal contact 1 x 2.5 mm 2 Switching capability of the thermostat s signal contact DC 2 A / DC 24 V (DC11) AC 2 A / AC 230V (AC11) Switch contact (NC) according to EN 61800-5-1 Catalog MOVITRAC LTP 47

Accessories 4 Braking resistors Dimension drawing braking resistors BW... / BW...-T / BW...-P 3 10 M4 B b A 12 C 1 2 2 4 d c C C B A ' a A M12 BW... : 1 = Flat design The connecting lead is 500 mm (19.7 in) long. The scope of delivery includes four M4 stud bolts each of type 1 and 2. 2 = Grid resistor 3 = Wire resistor 4 = Wire resistor with temperature switch (-T/-P) Cable entry (X) is possible from both sides. X B B d a 10 A c C c 8 a A M25 60021BXX Type BW... Mounting position Main dimensions mm (in) Fastening parts mm (in) Cable gland Weight kg (lb) BW..-T/ BW...-P A/A B C a b/c d BW106-T 2 795 (31.3) 270 (10.6) 490 (19.3) 770 (30.3) 380 (15) 10.5 (0.41) - 32 (71) BW206-T 2 995 (39.2) 270 (10.6) 490 (19.3) 970 (38.2) 380 (15) 10.5 (0.41) - 40 (88) BW012-025 2 295 (11.6) 260 (10.2) 490 (19.3) 270 (10.6) 380 (15) 10.5 (0.41) M12 + M25 8.0 (18) BW012-025-P 2 295/355 (11.6/14) 260 (10.2) 490 (19.3) 270 (10.6) 380 (15) 10.5 (0.41) M12 + M25 8.0 (18) BW012-050-T 2 395 (15.6) 260 (10.2) 490 (19.3) 370 (14.6) 380 (15) 10.5 (0.41) - 12 (26) BW012-100-T 2 595 (23.4) 270 (10.6) 490 (19.3) 570 (22.4) 380 (15) 10.5 (0.41) - 21 (46) BW027-006 3 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9) BW027-012 3 486 (19.1) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG11 4.3 (9.5) BW039-003 3 286 (11.3) 120 (4.72) 92 (3.6) 230 (9.06) 64 (2.5) 6.5 (0.26) PG11 1.5 (3.3) BW039-006 3 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9) BW039-012 3 486 (19.1) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG11 4.3 (9.5) BW039-012-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11) BW039-026-T 4 649 (25.6) 120 (4.72) 275 (10.8) 530 (20.9) 240 (9.45) 6.5 (0.26) M12 + M25 7.5 (17) BW039-050-T 2 395 (15.6) 260 (10.2) 490 (19.3) 370 (14.6) 380 (15) 10.5 (0.41) - 12 (26) BW147 3 465 (18.3) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG13.5 4.3 (9.5) BW147-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11) BW247 3 665 (26.2) 120 (4.72) 185 (7.28) 626 (24.6) 150 (5.91) 6.5 (0.26) PG13.5 6.1 (13) BW247-T 4 749 (29.5) 120 (4.72) 185 (7.28) 626 (24.6) 150 (5.91) 6.5 (0.26) M12 + M25 9.2 (20) BW347 3 670 (26.4) 145 (5.71) 340 (13.4) 630 (24.8) 300 (11.8) 6.5 (0.26) PG13.5 13.2 (29.1) BW347-T 4 749 (29.5) 210 (8.27) 185 (7.28) 630 (24.8) 150 (5.91) 6.5 (0.26) M12 + M25 12.4 (27.3) BW168 3 365 (14.4) 120 4.72) 185 (7.28) 326 (12.8) 150 (5.91) 6.5 (0.26) PG13.5 3.5 (7.7) BW168-T 4 449 (17.7) 120 (4.72) 185 (7.28) 326 (12.8) 150 (5.91) 6.5 (0.26) M12 + M25 3.6 (7.9) BW268 3 465 (18.3) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG13.5 4.3 (9.5) BW268-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11) BW072-003 1 110 (4.33) 80 (3.1) 15 (0.59) 98 (3.9) 60 (2.4) - 0.3 (0.7) BW072-005 1 216 (8.5) 80 (3.1) 15 (0.59) 204 (8.03) 60 (2.4) - 0.6 (1) BW100-005 1 216 (8.5) 80 (3.1) 15 (0.59) 204 (8.03) 60 (2.4) - 0.6 (1) BW100-006 4 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9) BW100-006-T 4 549 (21.6) 120 (4.72) 92 (3.6) 430 (16.9) 80 (3.1) 6.5 (0.26) M12 + M25 3.0 (6.6) 48 Catalog MOVITRAC LTP

Accessories Line chokes 4 4.2 Line chokes Line chokes reduce supply harmonic distortion and protect MOVITRAC LTP units against harmful supply disturbances. They are also used to reduce the effects of the MOVITRAC LTP upon supply harmonic distortion. L L H D N1 L N2 B 54801AXX 54886AXX Line chokes are also used to protect the power input circuits of the MOVITRAC LTP against voltage spikes which might originate from lightening strikes or other equipment on the same supply. The following units have built-in DC chokes and therefore do not require an external choke: 240 V, sizes 4 6 480 V, sizes 4 6 575 V, size 3 4.2.1 Technical data Type Part number MOVITRAC LTP Size Rated voltage [V] Phase Rated current [A] Inductance / limb [mh] ND LT 010 290 21 1) 18201644 1 <230 1 10 2.9 ND LT 025 110 21 1) 18201652 2 <230 1 25 1.1 ND LT 006 480 53 1) 18201660 1 <600 3 6 4.8 ND LT 010 290 53 1) 18201679 2 <600 3 10 2.9 ND LT 036 081 53 1) 18201687 3 <600 3 36 0.81 ND LT 016 183 21-55 18217680 1 <230 1 16 1.83 ND LT 025 117 21-55 18217699 2 <230 1 25 1.17 ND LT 006 613 63-55 18217702 1 <600 3 6 4.8 ND LT 010 386 63-55 18217710 2 <600 3 10 3.86 ND LT 020 183 63-55 18217729 3 <600 3 18 2.04 1) Not UL-approved Catalog MOVITRAC LTP 49

Accessories 4 Line chokes 4.2.2 Dimensions Type L B H N1 N2 D Mass [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [kg] [lb] ND LT 010 290 21 66 2.60 80 3.15 70 2.76 50 1.97 51 2.01 5 8 0.2 0.32 ND LT 025 110 21 85 3.35 95 3.74 95 3.74 64 2.52 59 2.32 5 8 0.2 0.32 ND LT 006 480 53 95 3.74 56 2.20 107 4.21 56 2.20 43 1.69 5 9 0.2 0.35 ND LT 010 290 53 125 4.92 71 2.80 127 5.00 100 3.94 55 2.17 5 8 0.2 0.32 ND LT 036 081 53 155 6.10 77 3.03 185 7.28 130 5.12 72 2.83 8 12 0.3 0.47 0.8 1.76 1.8 3.97 1.3 2.87 2.5 5.51 7.2 15.87 ND LT 016 183 21 55 82 3.23 70 2.76 70 2.76 70 2.76 58 2.28 6 0.24 1.0 2.20 ND LT 025 117 21 55 90 3.54 84 3.31 75 2.95 84 3.31 72 2.84 6 0.24 1.3 2.87 ND LT 006 613 63 55 115 4.53 74 2.91 88 3.46 80 3.15 60 2.36 5.5 7 0.22 0.28 1.6 3.53 ND LT 010 386 63 55 175 6.89 99 3.90 137 5.39 130 5.12 79 3.11 5.5 12 ND LT 020 183 63 55 175 6.89 114 4.49 137 5.39 130 5.12 94 3.70 5.5 12 0.22 0.47 0.22 0.47 3.5 7.72 7 15.43 50 Catalog MOVITRAC LTP

Accessories Output chokes 4 4.3 Output chokes Output chokes improve the quality of the output waveform. Therefore the maximum cable length stated in the rating table can be doubled when using an output choke. 64757AXX MOVITRAC LTP units, like the majority of other inverter drives, have unfiltered outputs. In the majority of applications this will give satisfactory performance, however, in a small number of applications output filtering is strongly recommended to improve system functionality, reliability and longevity. These applications include: Long motor cables, up to 300 m (the rated cable length can be doubled if an output choke is used) High capacitance motor cables (i.e. typical "pyro" wire, used for fire protection) Multiple motors connected in parallel Motors without inverter grade insulation (typically older motors) A range of high quality output chokes are available for MOVITRAC LTP with the following key features: Limits output voltage gradient, typically < 200 V/µs Limits transient over voltages at the motor terminals, typically < 1000 V Suppression of mains conducted interference in lower frequency ranges Compensation of capacitive load currents Reduction of RFI emissions from the motor cable Reduction of motor losses and audible noise caused by ripple Catalog MOVITRAC LTP 51

Accessories 4 Output chokes 4.3.1 Technical Data Type Part number IP-protection Size Phase HD LT 008 200 53 1820 1695 Rated voltage [V] Rated current [A] Inductance / Limb [mh] HD LT 030 050 53 1820 1717 3 480 18 0.5 IP00 HD LT 075 022 53 1820 1725 4 600 75 0.22 HD LT 180 009 53 1820 1733 5 3 600 180 0.09 1 480 8 2 HD LT 012 130 53 1820 1709 2 480 12 1.3 HD LT 250 007 53 1820 1741 6 600 250 0.065 HD LT 008 200 63 55 1821 6757 1 480 600 8 2 HD LT 012 120 63 55 1821 6765 IP55 2 480 600 12 1.2 HD LT 018 090 63 55 1821 6773 3 480 600 18 0.9 Comparison of output voltage and current characteristics Without choke [V] 1 1 [A] 2 2 64148AXX With choke [V] 1 1 [A] 2 2 64146AXX NOTE With a filter fitted the switching pulse rises slower and to a lower amplitude. 52 Catalog MOVITRAC LTP

Accessories Output chokes 4 4.3.2 Dimensions [1] L1 L2 L3 L1 L2 L3 [2] PE PE H N1 L ØD N2 B 64032AXX Type L B H N1 N2 D Weight [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [kg] [lb] HD LT 008 200 53 100 3.94 90 3.54 75 2.95 60 2.36 48 1.89 4 0.16 1.5 3.31 HD LT 012 130 53 125 4.92 115 4.53 85 3.35 100 3.94 55 2.17 5 0.20 3 6.61 HD LT 030 050 53 155 6.10 160 6.30 105 4.13 130 5.12 57 2.24 8 0.32 4.5 9.92 HD LT 075 022 53 190 7.48 255 10.04 125 4.92 170 6.69 68 2.68 8 0.32 10 22.04 HD LT 180 009 53 240 9.45 310 12.20 155 6.10 190 7.48 106 4.17 11 0.43 22 48.5 HD LT 250 007 53 300 11.81 390 15.35 210 8.27 240 9.45 121 4.76 11 0.43 40 88.18 HD LT 008 200 63 55 115 4.53 74 2.91 85 3.35 80 3.15 60 2.36 5.5 7 0.22 1.7 3.75 0.28 HD LT 012 120 63 55 140 5.51 87 3.43 110 4.33 100 3.94 70 2.76 5.5 7 0.22 3.2 7.05 0.28 HD LT 018 090 63 55 140 5.51 87 3.43 110 4.33 100 3.94 70 2.76 5.5 7 0.22 0.28 3.2 7.05 Catalog MOVITRAC LTP 53

Accessories 4 DIN rail mounting kit 4.4 DIN rail mounting kit A mounting kit is available to fit the MOVITRAC LTP onto a DIN rail. Type Part number MOVITRAC LTP Size FH LT DINHS 01 18201776 1 FH LT DINHS 02 18201784 2 54888AXX 4.5 Remote keypad option LT BG-00 Part number: 1820 8649 The basic version of the MOVITRAC LTP has an integrated keypad for some applications, however it is necessary to have an additional keypad in a remote area. The keypad option comes with a self-adhesive seal and a 3 m long cable to be plugged into the RJ11 connector on the MOVITRAC LTP unit. The maximum cable length between the keypad and the drive is 25 m for unshielded cable and 100 m for shielded cable. 60201AXX 54 Catalog MOVITRAC LTP

Accessories Remote keypad option LT BG-00 4 4.5.1 Installation in switch cabinet door or control panel To install LT BG-00 in the door of a switch cabinet or in a control panel the metal work has to be cut according to the drawing below. By using the included self-adhesive seal the installed keypad meets the IP54/NEMA 13 standard. a c g [1] b f h d e Dimension Drawing 60245AXX Switch cabinet mounting cut out 60246AXX [a] 81 mm [f] 3 mm [b] 66 mm [g] 70 mm [c] 65 mm [h] 55 mm [d] 21 mm [1] Cut out [e] 55 mm 60247AXX Up to 2 keypads can be installed in a drive network. In this case each drive must have a different address. The 2 keypads can then monitor and control parameters on the same drive or on different drives. The overall cable length in the network must not exceed 25 m for unshielded cable or 100 m for shielded cable. Catalog MOVITRAC LTP 55

Accessories 4 Cable splitter 1 in and 2 out 4.6 Cable splitter 1 in and 2 out Part number: 18208681 The cable splitter LT-RJ-CS-21 is required if the keypad is used in a drive network. 60202AXX 4.7 Prefabricated cables with RJ11 connector The prefabricated cables are available in 3 different lengths. Each cable is equipped with a 6-pin RJ11 connector on each end. Cable length Type Part number 0.3 m unshielded LT K-RJ-003 1820 8657 1.0 m unshielded LT K-RJ-010 1820 8665 3.0 m unshielded LT K-RJ-030 1820 8673 56 Catalog MOVITRAC LTP

Accessories Interface adapter option UWS11A 4 4.8 Interface adapter option UWS11A Part number: 822689X The UWS11A converts RS-232 signals, for example from the PC, into RS-485 signals. These signals can then be routed to the RJ11 connector on the MOVITRAC LTP unit. The USW11A requires a DC 24 V voltage supply (I max = 100 ma). There is no prefabricated cable available for the RS-485 interface. RS-232 interface RS-485 interface The connection between the USW11A and PC is made using a commercially available serial interface shielded cable. A maximum of 64 MOVITRAC LTP units can be networked for communication via the RS-485 interface of the USW11A. The maximum length of the shielded cable is 100 m. Dynamic terminating resistors are permanently installed, so do not connect any external terminating resistors. Permitted line cross section: 1 core per terminal 0.20 2.5 mm 2 (AWG 24 12). 2 cores per terminal 0.20 1 mm 2 (AWG 24 17). X1: RS-485 1 2 3 4 5 1 2 3 4 5 24V RS+ RS- X2: RS-232 75 UWS 5 86 22.5 83 Figure 3: UWS11A dimension drawing (mm) 01219CXX The UWS11A is mounted on a support rail (EN 50022-35 x 7.5) in the control cabinet. Catalog MOVITRAC LTP 57

Accessories 4 Interface adapter option LT-W-USB-RJ11 4.9 Interface adapter option LT-W-USB-RJ11 Part number: 18208703 The LT-W-USB-RJ11 option converts USB signals, for example from the PC into RS-485 signals. These RS-485 signals can then be routed to the RJ11 connector on the MOVITRAC LTP unit. 60203AXX The LT-W-USB-RJ11 option comes with cables, LTP shell CD and software CD for the interface. RS-485 interface A maximum of 63 MOVITRAC LTP units can be networked for communication via the RS-485 interface of the LT-W-USB-RJ11. The maximum length of the shielded cable is 100 m. 58 Catalog MOVITRAC LTP

Accessories Second relay output 4 4.10 Second relay output Type Part number OB LT 2ROUT 1822 3168 The 2nd relay output module can be used in applications where the analog output from the drive is converted to a relay output. Typical applications are where 2 relay outputs are required. The functions of the relays are programmable in the drive and can be any of the following: Drive enabled Drive healthy Drive at set speed Drive at zero speed Drive at maximum speed Motor in overload 1 2 3 4 5 6 7 8 9 10 11 64746AXX 64759AXX Terminal Signal Connection Description no. 1 +24 V +24 V ref out Ref. to activate DI1 DI3 (100 ma max.) 2 DI 1 Digital input 1 Positive logic 3 DI 2 Digital input 2 4 DI 3 Digital input 3 / thermistor contact "Logic 1" input voltage range: DC 8 30 V "Logic 0" input voltage range: DC 0 2 V Compatible with PLC requirement when 0 V is connected. 5 +10 V +10 V ref out 10 V ref for analog input (pot supply +, 10 ma max., 1 kω min.) 6 AI / DI Analog input (12 bit) Digital input 4 0 10 V, 0 20mA, 4 20 ma "Logic 1" input voltage range: DC 8 30 V 7 0 V 0 V common 0 V ref for analog input (pot supply ) 8 Relay 2 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 9 Relay 2 common Relay common 10 Relay 1 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 11 Relay 1 common Relay common Catalog MOVITRAC LTP 59

Accessories 4 Second relay output NOTE Once this option board has been installed and fully wired into an IP55 / NEMA 12 drive, the board must be bent slightly in a downwards direction to enable the front cover to be closed. This does not affect the function of the option board. Specification Max. relay switching voltage AC 250 V / DC 220 V Max. relay switching current 1 A Conformity IP00, UL94V-0 Environmental 10 +50 C Dimensions [mm] 56 24 (not pins) 14 [in] 2.20 0.98 (not pins) 0.56 60 Catalog MOVITRAC LTP

Accessories Third relay output 4 4.11 Third relay output Type Part number LT 3RO 00A 1820 8762 This plug-in output module provides 2 additional relay outputs. Relay 1 and 2 can be programmed via parameters. The third relay output is fixed to represent "Drive healthy" or "Drive tripped", depending on whther the N.C. or N.O. contacts are used. 12 13 14 1 2 3 4 5 6 7 8 9 10 11 65047AXX 64760AXX Terminal Signal Connection Description no. 1 +24 V +24 V ref out Ref. to activate DI1 DI3 (100 ma max.) 2 DI 1 Digital input 1 Positive logic 3 DI 2 Digital input 2 "Logic 1" input voltage range: DC 8 30 V "Logic 0" input voltage range: DC 0 2 V 4 DI 3 Digital input 3 / thermistor contact Compatible with PLC requirement when 0 V is connected. 5 +10 V +10 V ref out 10 V ref for analog input (pot supply +, 10 ma max., 1 kω min.) 6 AI / DI Analog input (12 bit) Digital input 4 0 10 V, 0 20mA, 4 20 ma "Logic 1" input voltage range: DC 8 30 V 7 0 V 0 V common 0 V ref for analog input (pot supply ) 8 Relay 2 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 9 Relay 2 common Relay common Programmable in drive (P2-11) 10 Relay 1 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 11 Relay 1 common Relay common Programmable in drive (P2-13) 12 Relay 3 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 13 Relay 3 contact Relay contact "Drive healthy" or "Drive tripped". Enabled when P2-01 = 20, 21 or 22. 13 Relay 3 common Relay common NOTE Once this option board has been installed and fully wired into an IP55 / NEMA 12 drive, the board must be bent slightly in a downwards direction to enable the front cover to be closed. This does not affect the function of the option board. Catalog MOVITRAC LTP 61

Accessories 4 Third relay output Specification Max. relay switching voltage AC 250 V / DC 220 V Max. relay switching current 1 A Conformity IP00, UL94V-0 Environmental 10 +50 C Dimensions [mm] 56 24 (not pins) 14 [in] 2.20 0.98 (not pins) 0.56 62 Catalog MOVITRAC LTP

Accessories Two indicator relay 4 4.12 Two indicator relay Type Part number OB LT HVAC-B 1821 8180 The HVAC relay option module can be used in applications where 2 indicators are required showing "drive running" and "drive tripped". 12 13 1 2 3 4 5 6 7 8 9 10 11 64748AXX 64760AXX Terminal Signal Connection Description no. 1 +24 V +24 V ref out Ref. to activate DI1 DI3 (100 ma max.) 2 DI 1 Digital input 1 Positive logic 3 DI 2 Digital input 2 "Logic 1" input voltage range: DC 8 30 V "Logic 0" input voltage range: DC 0 2 V 4 DI 3 Digital input 3 / thermistor contact Compatible with PLC requirement when 0 V is connected. 5 +10 V +10 V ref out 10 V ref for analog input (pot supply +, 10 ma max., 1 kω min.) 6 AI / DI Analog input (12 bit) Digital input 4 0 10 V, 0 20mA, 4 20 ma "Logic 1" input voltage range: DC 8 30 V 7 0 V 0 V common 0 V ref for analog input (pot supply ) 8 AO / DO Analog output (10 bit) Digital output 0 10V, 20mA analog 24 V / 20 ma digital 9 0 V 0 V common 0 V ref for analog output 10 Relay 1 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 11 Relay 1 common Relay common 12 Relay 2 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 13 Relay 2 common Relay common NOTE Once this option board has been installed and fully wired into an IP55 / NEMA 12 drive, the board must be bent slightly in a downwards direction to enable the front cover to be closed. This does not affect the function of the option board. Catalog MOVITRAC LTP 63

Accessories 4 Two indicator relay Specification Max. relay switching voltage AC 250 V / DC 220 V Max. relay switching current 1 A Conformity IP00, UL94V-0 Environmental 10 +50 C Dimensions [mm] 56 24 (not pins) 14 [in] 2.20 0.98 (not pins) 0.56 64 Catalog MOVITRAC LTP

Accessories Converter card 4 4.13 Converter card Type Part number Description OB LT VCON A 1821 7672 110 V / 24 V converter OB LT VCON B 1822 1947 240 V / 24 V converter The converter card allows the digital inputs of the drive to be controlled directly from a 110 V or 240 V control supply without the need for interfacing relays. NOTE The existing analog input can still be used by connecting the analog signal input on terminal 6. All other inputs and outputs to the drive are not affected. The digital input terminals are optically isolated from the remaining terminals and the drive terminals. 12 13 1 2 3 4 5 6 7 8 9 10 11 64748AXX 64760AXX Terminal Signal Connection Description no. 1 Neutral Neutral Must not be connected to 0 V 2 DI 1 Digital input 1 AC 80 250 V, 68 k impedance 3 DI 2 Digital input 2 4 DI 3 Digital input 3 5 +10 V +10 V ref out 10 V ref for analog input (pot supply +, 10 ma max., 1 kω min.) 6 AI / DI Analog input (12 bit) Digital input 4 0 10 V, 0 20 ma, 4 20 ma "Logic 1" input voltage range: DC 8 30 V 7 0 V 0 V common 0 V ref for analog input (pot supply ) 8 AO / DO Analog output (10 bit) Digital output 0 10V, 20mA analog 24 V / 20 ma digital 9 0 V 0 V common 0 V ref for analog output 10 Relay 1 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A) 11 Relay 1 common Relay common 12 Neutral Neutral Must not be connected to 0 V 13 DI4 Digital input 4 AC 80 250 V, 68 k impedance Catalog MOVITRAC LTP 65

Accessories 4 Converter card NOTE Once this option board has been installed and fully wired into an IP55 / NEMA 12 drive, the board must be bent slightly in a downwards direction to enable the front cover to be closed. This does not affect the function of the option board. Specification Max. relay switching voltage AC 250 V / DC 220 V Max. relay switching current 1 A Conformity IP00, UL94V-0 Environmental 10 +50 C Dimensions [mm] 56 24 (not pins) 14 [in] 2.20 0.98 (not pins) 0.56 66 Catalog MOVITRAC LTP

Accessories Local switchboard 4 4.14 Local switchboard Type Part number OB LT LOCMO 1820 5607 The local switchboard is an auxiliary way to enable and control the speed of the drive via the input terminal block. The board has switches which are directly connected to the digital inputs. The potentiometer is connected to the analog input. NOTE This option should only be used for test purposes. For field application a hard wire connection must be used to control the drive. 1 2 3 4 5 6 7 8 9 10 11 64770AXX 64771AXX NOTE The terminal connections on the local switchboard are the same as those on the MOVITRAC LTP unit. Specification Conformity IP00, UL90V-0 Environmental 10 +50 C Dimensions [mm] 56 33 (not pins) 16 [in] 2.20 1.31 (not pins) 0.64 Catalog MOVITRAC LTP 67

Accessories 4 Lock 4.15 Lock Type Part number LZ LOCK1-A 1821 7745 65198AXX 65207AXX The lock can be used to secure against unauthorised starting of the inverter. This option can be installed on all drives with switches in IP55 housing. 4.16 MC LTP CE, Pocket PC BG LT OWDCE Type Part number MC LTP CE 1820 1792 The BG LT OWDCE Pocket PC and the LTP Shell CE software provide a fast and efficient means of commissioning of the MOVITRAC LTP, with the ability to upload and download parameters, save drive parameters to a file, export drive parameters to Microsoft Word, control of the drive and monitor status of motor and inputs/outputs. 60392AXX 68 Catalog MOVITRAC LTP