DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

The Da-Lite Difference.

Owner s Guide. For Model: CA1B5. Flashlogic FLRS RF Upgrade Kit

Model 2300DL Installation Guide

Owner s Guide PE1BZ PE1BZLR

Installer Guide smart connect

SECTION 1 1 INSTRUMENTS AND CONTROLS

SECTION 1 2 OPERATION OF INSTRUMENTS AND CONTROLS 03_SEQUOIA_U (L/O 0301) Keys and Doors

IVTM Installation Manual

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing.

TWO-WAY LED MANUAL TRANSMISSION REMOTE STARTER. User Guide WARNING

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

Check with your installation center for features and functions operational on your system.

Easy-On Wireless Tail Lights User s Guide

Model 2300JL Installation Guide

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

Owner s Guide. For Model: PE5BZ. Flashlogic FLRS RF Upgrade Kit

The Da-Lite Difference.

p wered BLINDS control at your fingertips Installation, Programming & Operation Guide 12Vdc Powered Roman Blind

Monnit Wireless Range Extender Product Use Guide

Thunder Power Tarp Kit Operation

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Owner s Guide CA2LCD5

TWO-WAY LED MANUAL / AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 OPERATE 1

Parkit360 Transformer

Operators Type /24 DC and 120V-60Hz AC

Auto-Lift Operating System

CA-510a Installation Instructions

INSTALLATION GUIDE. FCC ID NOTICE

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318

Installation Instructions: Read these instructions in its entirety before performing any installation work.

)LUHQ]H installation manual

Remote Engine Starter System I User s Information Manual

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Dual Roller Fascia Coupled FlexShades Assembly and Installation Instructions

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL

AIR HOGS BOEING AH-64D APACHE RC HELICOPTER INSTRUCTION MANUAL

SECTION 1 2 OPERATION OF INSTRUMENTS AND CONTROLS MR2 U. Keys and Doors. Engine immobiliser system Side doors Power windows...

Manual. and installation instructions. TigerShark 2.0. Technology by:

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

401B/1KDB CoolRite/FreezeRite Installation Manual I003

CA 421 Installation Instructions

TRAC-Station BT Installation Instructions

WirelessONE. Kit INSTALLATION GUIDE. Key Fob Activated Compressor System

Owner s Guide PE2LCDZ PE1M2LCDZ

Solar Powered Wireless Temperature Station & Sensor

Surepowr Series 100 Installation Manual

Wireless Portable Amplifier System Operation manual

PowerControl VI: Getting Started May 4th

Installation, Operation and Maintenance Manual

WIRELESS CAMPER JACK LITERATURE NUMBER REV. C CCD WARNING PERSONAL INJURY & PROPERTY DAMAGE WARNING EXPLOSION. Effective NOV 2018

Smart Sensor Pro+ User Guide

V-D2425 and V-D2440 Digital Clock

CAUTION-ELECTRICALLY OPERATED PRODUCT

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

Rolli o RTS. Quick Commissioning Guide XSE

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Access XL Electric Projection Screen by Draper

USER MANUAL QUICK INSTALLATION GUIDE MRGB65B

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

Installation Instructions for Drapery System Drapery

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents:

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

INSTALLATION M ANUAL

Sonesse 30 WireFree RTS. Instructions

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

AS-1774 / 1774U. User Guide 5-BUTTON AUTOMATIC / MANUAL TRANSMISSION REMOTE STARTER

Damper Actuator Installation

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

ALTITUDE ARMS AND CANOPY

CSI-300 Installation Instructions

AUTOMATIC CONTROL ROLLING DOOR OPENER

Owner s Guide CA2LED5

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

Technology Versatility Practicality

Tors mo Tubular

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

TPMS (Tire Pressure Monitoring Systems)

TRAC-3 TENSION READOUT AND CONTROL

APS-687TWE of 12. Table Of Contents: Owners Guide Deluxe 7 Channel LED Remote Start System With Keyless Entry

AS-RFK2315. User Guide. Two-Way FM LED Remote System. Available functionalities depend on vehicle. Consult your dealer for more information.

TB-690 Conveyor/Stacker

4 WAY WIRELESS REMOTE CONTROL SYSTEM. User Manual

Installation & Operation Manual

RS-230-DP. Operation Guide

AutoLabeler. User s Guide A (3/02).01

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Transcription:

Table Of Contents Motor Selection Guide 2-12 - Shades, Shutters and Doors - Retractable Awnings Installation Instructions 13-1 - Operator Adaptors - Operator Limit Adjustment - Wiring Considerations - Hz Operator Quick Programming Guide Operators 20-32 - 3.5, 5, 6, 5DMI, 6DMI, 5 Hz, 5 DMI Hz, 6 Hz and 6 DMI Hz (Uses: Shade, Shutter and Awnings) - 8, and Central (Uses: Shutters, Doors) Operator Accessories 33-42 - Safety Brakes, Motor Brackets and Adaptors Electronic Controls 43-57 - Hz Wireless Controls, Radio Controls, Environmental Controls, Battery Back Control, Switches and Transformers Manual Accessories 58-70 - Gears, Universals, Springs, Handles, Wall Brackets and Plates Copyright SIMU U.S., Inc. All rights reserved. No part of this catalog may be reproduced in any manner, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, photocopying or otherwise without the prior written permission of SIMU U.S., Inc. 1 Printed in the USA September 7

For Rolling Shutters and Doors To select a motor in this guide you need to know the following: 1. of Slat: Height and Width 2. Total weight of shutter 3. Diameter of the tube of slat: It is important to consider the total size of the product you plan to produce before choosing an operator, since these variables affect the weight of what an operator can lift. The following charts represent some of the most common motor solutions. Choose the one that most closely corresponds to the weight that you calculate. Total Weight of Shutter Height of Housing Height Total weight = Width x (Height Height of Housing) x Weight per sq. ft. surface Important Note: The choice of a motor also depends on the type of installation. - If you use one motor for two or more shutters add 20% for the first additional shutter to derive the total weight. Add an additional 10% for every shutter after that. Examples: 2 shutters/one motor = 20% to the total weight. 3 shutters/one motor = 20% 10% to the total weight. W id th - If the shutter is over feet in height, add 10% to the total weight for every three feet beyond. Example: 11 feet in height= total weight an additional 10% to the effective load to be lifted. Diameter of Tube: The lifting capacity of an operator decreases when the tube diameter increases. Therefore, it is necessary to choose the smallest tube while considering the load capacity of the tube and the optimum roll-up diameter of the slats. Keep in mind that if tube spacer rings are used, you have increased the tube diameter. After choosing the chart that corresponds to the tube size being used, select the operator according to the total weight of the shutter. 2

For 3.5 Operators 36mm (1.5 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 353 25(lbs.) 356 4(lbs.) 35 74(lbs.) 40mm (1.7 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 353 21(lbs.) 356 43(lbs.) 35 65(lbs.) 50mm (2.0 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 353 (lbs.) 356 37(lbs.) 35 55(lbs.) -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity. 3

For 5 Operators 50mm (2.0 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 505 510 37(lbs.) 62(lbs.) 515 2(lbs.) 520 123(lbs.) 525 154(lbs.) 530 5(lbs.) 535 216(lbs.) 246(lbs.) 308(lbs.) 60mm (2.5 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 505 510 30(lbs.) 4(lbs.) 515 74(lbs.) 520 8(lbs.) 525 530 123(lbs.) 148(lbs.) 535 172(lbs.) 15(lbs.) 246(lbs.) -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity. 4

For 5 Operators 70mm (2.75 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 505 27(lbs.) 510 45(lbs.) 515 67(lbs.) 520 8(lbs.) 525 530 112(lbs.) 134(lbs.) 535 157(lbs.) 17(lbs.) 224(lbs.) 78mm (3.0 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 505 25(lbs.) 510 515 41(lbs.) 62(lbs.) 520 (lbs.) 525 530 535 103(lbs.) 123(lbs.) 143(lbs.) 1(lbs.) 205(lbs.) -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity. 5

For 5 Operators 85mm (3.25 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 505 22(lbs.) 510 515 520 525 530 38(lbs.) 57(lbs.) 76(lbs.) 5(lbs.) 114(lbs.) 535 132(lbs.) 152(lbs.) (lbs.) 0mm (3.5 inch) TUBE DIAMETER 27 36 45 55 1 20 40 60 80 120 505 21(lbs.) 510 515 520 525 530 535 35(lbs.) 53(lbs.) 70(lbs.) 88(lbs.) 105(lbs.) 123(lbs.) 141(lbs.) 176(lbs.) -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity. 6

For 6 Operators 60mm (2.5 inch) TUBE DIAMETER 1 1 1 20 2 420 440 460 480 25(lbs.) 34(lbs.) 6 43(lbs.) 70mm (2.75 inch) TUBE DIAMETER 1 1 1 20 2 420 440 460 480 268(lbs.) 358(lbs.) 6 448(lbs.) 78mm (3.0 inch) TUBE DIAMETER 1 1 1 20 2 420 440 460 480 246(lbs.) 328(lbs.) 6 410(lbs.) -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity. 7

For 6 Operators 85mm (3.25 inch) TUBE DIAMETER 1 1 1 20 2 420 440 460 480 226(lbs.) 303(lbs.) 6 37(lbs.) 0mm (3.5 inch) TUBE DIAMETER 1 1 1 20 2 420 440 460 480 210(lbs.) 281(lbs.) 6 352(lbs.) mm (4.0 inch) TUBE DIAMETER 1 1 1 20 2 420 440 460 480 5(lbs.) 246(lbs.) 6 308(lbs.) -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity. 8

For 8 Operators mm (4.0 inch) TUBE DIAMETER Scale Changes 1 205 250 278 25 3 341 3 386 40 432 455 545 5 636 6 727 450 600 650 700 750 800 850 00 50 0 1 1 1 0 1 0 0 551(lbs.) 40 60 is not available for mm tube 80 114mm (4.5 inch) TUBE DIAMETER Scale Changes 1 205 250 278 25 3 341 3 386 40 432 455 545 5 636 6 727 450 600 650 700 750 800 850 00 50 0 1 1 1 0 1 0 0 544(lbs.) 40 60 is not available for 114mm tube 80 -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity.

For 8 and Operators mm (5.0 inch) TUBE DIAMETER Scale Changes 1 205 250 278 25 3 341 3 386 40 432 455 545 5 636 6 727 450 600 650 700 750 800 850 00 50 0 1 1 1 0 1 0 0 40(lbs.) 40 86(lbs.) 60 1478(lbs.) 80 80 is not available for mm tube mm (5.5 inch) TUBE DIAMETER Scale Changes 1 205 250 278 25 3 341 3 386 40 432 455 545 5 636 6 727 450 600 650 700 750 800 850 00 50 0 1 1 1 0 1 0 0 445(lbs.) 40 86(lbs.) 60 1344(lbs.) 80 80 is not available for mm tube -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity. 10

For 8 and Operators mm (6.25 inch) TUBE DIAMETER Scale Changes 1 205 250 278 25 3 341 3 386 40 432 455 545 5 636 6 727 450 600 650 700 750 800 850 00 50 0 1 1 1 0 1 0 0 3(lbs.) 40 787(lbs.) 60 0(lbs.) 80 1574(lbs.) 210mm (8.25 inch) TUBE DIAMETER Scale Changes 1 205 250 278 25 3 341 3 386 40 432 455 545 5 636 6 727 450 600 650 700 750 800 850 00 50 0 1 1 1 0 1 0 0 26(lbs.) 40 56(lbs.) 60 84(lbs.) 80 113(lbs.) -This chart reflects the recommended 30% security factor that is used for most applications. -Shutters more than feet high: add 10% to the effective load for every additional 3 feet. -Double span shutters: add 20% to the effective load to be lifted. -All chart calculations are based on the (O.D.) outside diameter. Please take caution when sizing shutters with tube spacer rings as this will reduce the amount of operator lifting capacity. 11

For Retractable Awning Systems B Number of Arms C Length of Installation 1 Pair (2 arms) 20 ft. (6m) 2 Pair (4 arms) 33 ft. (10m) 3 Pair (6 arms) 50 ft. (15m) 4 Pair (8 arms) 66 ft. (20m) 5 Pair (10 arms) ft. (25m) 6 Pair (12 arms) ft. (30m) A Projection of Arms 5 ft. (1.50m) D Roller Tube O.D. Sizes 2.5" (63) 3.0" (78) 3.5" (8) 525 535 535 535 6.5 ft. (2.00m) 2.5" (63) 3.0" (78) 3.5" (8) 525 535 535 6 8 ft. (2.40m) 2.5" (63) 3.0" (78) 3.5" (8) 535 6 ft. (2.70m) 2.5" (63) 3.0" (78) 3.5" (8) 6 6 10 ft. (3.00m) 2.5" (63) 3.0" (78) 3.5" (8) 6 6 13.5 ft. (4.00m) 16.5 ft. (5.00m) 2.5" (63) 3.0" (78) 2.5" (63) 3.0" (78) 6 6 6 Above chart is approximate. For more specific information, refer to factory. This chart can be used to select the most suitable type of motor for your lateral arm awning system. Important: The lateral arms referred to here are the standard aluminum type with built-in tension springs. When considering arms made of steel and/or using other types of spring mechanisms, please request additional information. 1. Locate the projection of your lateral arm on the above chart at point (A); e.g. 5 ft., 6 ft., 8 ft., etc. 2. Determine which roller tube diameter (D) is being used in your installation. 3. Locate the number of arms (B) and the length of your installation (C). 4. Read the correct motor from the chart at the intersection of your selections. NOTE: Because this chart must take into consideration lateral arms being manufactured by many different companies, it is only approximate. The relationship between the number of arms and the length of the awning is only a guide and will vary slightly from manufacturer to manufacturer. 12

Adaptor Installation Instructions Installation Instructions For Snap-On Adaptors 3.5 / 5 / 6 / 5DMI / 6DMI HARD CLIP (Fixed) Drive Wheel Motor Shaft Locked in Place Motor Shaft SOFT CLIP (Removable) Drive Wheel Motor Shaft in Place Clips Closed Grooves Open Grooves Installation of the drive wheel to the motor shaft: Push the drive into the motor shaft until you hear a "click". Two clips lock the drive wheel into the motor shaft. There are two types of drive wheels: Removable or "Soft Clip" type, and fixed or "Hard Clip" type. The "Soft Clip" drives are available only for round tubes in 2", 2.5" and 2.75" diameters. The drive wheel can be removed by physically pulling it off the motor shaft. For the ease of identification all "Soft Clip" drives are brown. The "Hard Clip" drives can only be removed from the shaft by pressing the two clips inward at the same time. The motor must be out of the tube in order to have access to the clips. These drives are black. Installation in round tubes: The drive must be riveted to the tube after the motor is inserted. Installation in profiled tubes: The drive doesn't need to be riveted to the tube because it is already in a positive lock position within the profiled tube. Installation Instructions For Adaptors 8 / Operators Drive Wheel Drive Locking Nut Motor Shaft 13

Limit Switch Adjustment 3.5 / 5 / 6 8 and Operators MATERIAL ROLLS DOWN ON SAME SIDE AS LIMITS UP LIMIT ADJUSTMENT SCREW MATERIAL ROLLS DOWN ON OPPOSITE SIDE FROM LIMITS DOWN LIMIT ADJUSTMENT SCREW DOWN LIMIT ADJUSTMENT SCREW 1 UP LIMIT ADJUSTMENT SCREW 2 1) Identify which limit adjustment screw controls the up limit and which controls the down limit (see above diagrams). It is important to note that the arrows by the limit adjustment screw refer to the tube's rotation. Thus if the material comes off the tube on the back side and the limit adjustment screws face the front (as per diagram 2), the limit adjustment screw facing up controls the down limit and vice versa. 2) Turning an adjustment screw clockwise will increase the maximum travel in the direction that it controls, and turning it counterclockwise will decrease the maximum travel. 3) To set a limit, run the motor in the selected direction. 4) If the motor stops on its own before reaching the desired stop, turn the appropriate limit screw positive (clockwise). Every 2 to 3 turns of the limit adjustment screw will allow the motor to travel about 1 inch further. After every few turns of the limit adjustment screw, use the control switch to move the motor to the new limit position. (If the motor does not stop on its own before reaching the desired limit, go to step 6) 5) When you are approximately at the desired limit position, use the control switch to run the motor away from the limit 2 to 3 feet, and then back. This will allow you to see precisely where the limit is set. Make small adjustments and repeat. 6) If the motor does not stop on its own at least 6 inches before the desired limit position, stop the motor with the control switch. Then turn the limit adjustment screw in the negative (counterclockwise) direction. Confirm that the motor is stopped at the limit and set the limit as per steps 4 and 5. If the motor is not stopped at the limit, continue turning the limit adjustment screw counterclockwise (up to 120 turns may be required ) NOTE: The motor has a built in thermal cutoff. If after several minutes of use the motor will not run in either direction, allow the motor to cool for approximately 20 minutes. 14

Limit Switch Adjustment 5 and 6 DMI Operators MATERIAL ROLLS DOWN ON SAME SIDE AS LIMITS UP LIMIT ADJUSTMENT SCREW MATERIAL ROLLS DOWN ON OPPOSITE SIDE FROM LIMITS DOWN LIMIT ADJUSTMENT SCREW DOWN LIMIT ADJUSTMENT SCREW UP LIMIT ADJUSTMENT SCREW MOTOR CABLE MOTOR CABLE LIMIT ADJUSTMENT SCREWS ON OPPOSITE SIDE FROM MOTOR CABLE 1 2 LIMIT ADJUSTMENT SCREWS ON SAME SIDE AS MOTOR CABLE MATERIAL ROLLS DOWN ON SAME SIDE AS LIMITS MATERIAL ROLLS DOWN ON OPPOSITE SIDE FROM LIMITS DOWN LIMIT ADJUSTMENT SCREW UP LIMIT ADJUSTMENT SCREW MOTOR CABLE MOTOR CABLE UP LIMIT ADJUSTMENT SCREW 3 4 DOWN LIMIT ADJUSTMENT SCREW 1) Identify which limit adjustment screw controls the up limit and which controls the down limit (see above diagrams). It is important to note that the arrows by the limit adjustment screw refer to the tube's rotation. Thus if the material comes off the tube on the back side and you are adjusting the limits from the side that the motor cable is not on (as per diagram 2), the limit adjustment screw with the arrow facing up controls the down limit and vice versa. 2) Turning an adjustment screw positive () will increase the maximum travel in the direction that it controls, and turning it negative (-) will decrease the maximum travel. For the adjustment screws on the side without the motor cable, turning clockwise is positive () and counterclockwise is negative (-). For the adjustment screws on the side with the motor cable, turning clockwise is negative (-) and counterclockwise is positive () 3) To set a limit, run the motor in the selected direction. 4) If the motor stops on its own before reaching the desired stop, turn the appropriate limit screw positive. Every 2 to 3 turns of the limit adjustment screw will allow the motor to travel about 1 inch further. After every few turns of the limit adjustment screw, use the control switch to move the motor to the new limit position. (If the motor does not stop on its own before reaching the desired limit, go to step 6) 5) When you are approximately at the desired limit position, use the control switch to run the motor away from the limit 2 to 3 feet, and then back. This will allow you to see precisely where the limit is set. Make small adjustments and repeat. 6) If the motor does not stop on its own at least 6 inches before the desired limit position, stop the motor with the control switch. Then turn the limit adjustment screw in the negative direction. Confirm that the motor is stopped at the limit and set the limit as per steps 4 and 5. If the motor is not stopped at the limit, continue turning the limit adjustment screw. (up to 120 turns may be required ) NOTE: The motor has a built in thermal cutoff. If after several minutes of use the motor will not run in either direction, allow the motor to cool for approximately 20 minutes. 15

Wiring Considerations ( Four Wire Operators ) Because of the type of motor (Asynchronous with built-in capacitor) and the built-in limit switches, it is important to follow two important recommendations to assure proper operation of the motorized systems - SIMU operators are not universal motors. 1. Do Not Wire SIMU Operators in Parallel. Parallel Wiring Means: Several Operators are Wired to Only One Electrical Contact Per Direction of Rotation. There will be constant feedback from one motor to another, so stopping points will not be stable and there is a risk of motor burn out. Correct: Correct wiring solution is to use a double pole, double throw, center off switch which would isolate both motors. Incorrect: Motor A stops at its limit in direction 2 before Motor B. Current in Motor B feeds back to Motor A through the capacitor C2 and microswitches M3 and M1. Both operators keep rotating in opposite directions at reduced power. 2. Do Not Control One SIMU Operator from Several Locations Without Using a Proper Controller. Correct: Possible problem: When switch (1) is turned on, the motor will begin running in direction 1. As it reaches its limit, the microswitch M1 will open. If at the same moment in time switch (2) is turned on, the motor will operate in the opposite direction. This is why we recommend the use of momentary switches with the SIMU TR115 sequence relay control. Incorrect: The microswitch M1 closes, short-circuiting the capacitor which is loaded at its maximum voltage (V). As a result the microswitch M1 is damaged. Solution: Use relays to build priorities between controls sending opposite signals. Do not use standard a light switch as a motor control. Note: SIMU Control Systems are designed to comply with these two basic criteria and assure reliable operation of motorized systems. Non-compliance to these two basic principles void the SIMU warranty. HOT 1 2 4 GND M1 M2 SWITCH C W1 W2 120V - 60Hz TP NEUTRAL 3 M1 M2 C W1 Microswitch Microswitch Capacitor Motor Wiring SYMBOLS W2 TP GND Motor Winding Thermal Protector Ground CORRECT M1 M1 M2 A TP M2 C1 MOTOR A TP DP DT SWITCH M3 M3 M4 B TP M4 C2 MOTOR B TP HOT 120V - 60Hz NEUTRAL HOT 120V - 60Hz NEUTRAL CORRECT INCORRECT SWITCH 1 Relay M1 M2 C W1 W2 TP 3 SWITCH 1 M1 M2 C W1 W2 TP 3 SWITCH 2 SWITCH 2 120V - 60Hz HOT 120V - 60Hz NEUTRAL HOT CORRECT NEUTRAL 16 INCORRECT

Wiring Considerations ( Three Wire Operators / Hz Operators) OPERATOR WIRING CHART MOTOR CABLE BLACK WHITE GREEN POWER 120VAC HOT NEUTRAL GROUND POWER 120VAC 60Hz HOT NEUTRAL GROUND BLACK WHITE GREEN 1) FCC -This device complies with part 15 of the FCC Rules. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. -Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. 2) Hz Operator Wiring All wiring must conform to the National Electrical Code and local codes -The Hz operator can be wired to power in parallel (unlike normal AC tubular operators) -It is recommended that provisions be made to cut power individually when wiring Hz operators. This can be in the form of an inline off/on switch, a disconnect plug, or access to the operator cable for use of a installers power cable with off/on switch. The ability to cut the power to each motor individually is required to easily program the receiver in the operator. 3) Installation -The Hz motor uses standard T5 (not DMI) accessories. -Use only SIMU accessories (brackets, adaptors, clips...) -Mount Hz motor heads at least inches from each other to prevent RF interference. -Always install the power cable with a drip loop to prevent water penetration -SIMU motors conform to IP44 requirements and as such must be protected against direct weather elements such as rain, sleet,...etc. 17

Hz-02 Plus Operators (Electronic Limit) Basic Programming STEP 1 Wake the motor by pressing the UP and DOWN buttons simultaneously until the motor jogs Note: After every command the motor will jog to confirm STEP 2 Check the direction of rotation with the UP or DOWN button. If needed, change the direction of rotation by pressing and holding the STOP button until the motor jogs. STEP 3 Run the motor to the desired upper limit. Press the STOP and DOWN buttons simultaneously until the motor starts to run downward. Use the STOP button to stop the motor near the desired lower limit. STEP 4 Use the UP or DOWN button to run the motor to the exact desired lower limit. Press the STOP and UP buttons simultaneously until the motor starts to run. Use the STOP button to stop the motor. STEP5 Press and hold the STOP button until the motor jogs to confirm the limit settings. Note: Until this step, the up or down limit can be moved by repeating step 3 or step 4 STEP 6 Press and hold the PROGRAM button on the back of the transmitter until the motor jogs. The buttons no long have to be held for the motor to run. Double check the limits are in the desired position IMPORTANT: The programming button in step 6 will not work until the limits have been confirmed as per step 5 ADJUSTING THE LIMITS AFTER THE MOTOR HAS BEEN PROGRAMMED. To change the upper limit run the motor to its upper limit and let it stop. Press the UP and DOWN buttons simultaneously until the motor jogs. Run the motor to the new desired upper limit. Press and hold the STOP button until the motor jogs. Check the new limit. To change the lower limit run the motor to its lower limit and let it stop. Press the UP and DOWN buttons simultaneously until the motor jogs. Run the motor to the new desired lower limit. Press and hold the STOP button until the motor jogs. Check the new limit. To add or delete a remote/channel press the PROGRAMMING button on the back of an already programmed remote/channel until the motor jogs. Next press the PROGRAMMING button on the back of the remote/channel you wish to add or delete until the motor jogs. To reset the motor to factory mode start with the motor connected to power. Cut power for 8 seconds, reconnect power for 8 seconds, cut power for 8 seconds and then reconnect power. The motor should start to run (if this does not happen repeat the 8 second power cuts until the motor does run). Allow the motor to stop on its own (do not press stop, up or down or you will have to repeat the double power cut) Once the motor stops on its own, press and hold the PROGRAMMING button for over 8 seconds. The motor should jog twice.

Hz-02 (Progressive Limit) Basic Programming STEP 1 Wake the motor by pressing the UP and DOWN buttons simultaneously until the motor jogs. Note: After every command the motor will jog to confirm STEP 2 Check the direction of rotation with the UP or DOWN button. If needed, change the direction of rotation by pressing and holding the STOP button until the motor jogs. STEP 3 Press and hold the PROGRAM button on the back of the transmitter until the motor jogs. The buttons no long have to be held for the motor to run. Double check the limits are in the desired position. To add or delete a remote/channel press the PROGRAMMING button on the back of an already programmed remote until the motor jogs. Next press the PROGRAMMING button on the back of the remote you wish to add or delete until the motor jogs. To reset the motor to factory mode start with the motor connected to power. Cut power for 8 seconds, reconnect power for 8 seconds, cut power for 8 seconds and then reconnect power. The motor should start to run (if this does not happen repeat the 8 second power cuts until the motor does run). Allow the motor to stop on its own (do not press stop, up or down or you will have to repeat the double power cut) Once the motor stops on its own, press and hold the PROGRAMMING button for over 8 seconds. The motor may jog twice. Wall Switch Transmitter Decorator Wall switch Side of Transmitter Handheld Transmitter Hz Timer PROGRAM BUTTON SINGLE CHANNEL FIVE CHANNEL PROGRAM BUTTON SINGLE CHANNEL FIVE CHANNEL PROGRAM BUTTON PROGRAM BUTTON 1