Addendum to the Operating Instructions

Similar documents
Operating Instructions

MOVIMOT mounting close to the motor (remote)

Addendum to the Operating Instructions

11 DR Series AC Motors with Decentralized Technology

Assembly Instructions

Operating Instructions

Necessary information regarding the machine to be driven Technical data and environmental conditions Positioning accuracy Travel cycle calculation

For regenerative operation, the MOVIPRO is connected to an external braking resistor.

Addendum to the Operating Instructions

Addendum to the Operating Instructions

Assembly Instructions

Addendum to the Operating Instructions

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

7 Important information on selection tables and dimension drawings

Drive Technology \ Drive Automation \ System Integration \ Services. Data sheet. MOVIAXIS Multi-Axis Servo Inverter. Information regarding UL

10 Other options and design types

Drive Technology \ Drive Automation \ System Integration \ Services. Revision MOVIFIT FC

CMS Electric Cylinder. Addendum to the Operating Instructions. Edition 11/ / EN

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating Instructions

8 Important Information about Tables and Dimension Sheets

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating Instructions

Manual. Brake Diagnostics (as of V ) * _0415* Phone: Fax: Web: -

Exchange of rollers from the XTS-Mover

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

Addendum to the Geared Servomotors Catalog

Operating Instructions

Caution: Wear protective goggles danger of chipped pieces! 01733AXX

Addendum to the Operating Instructions

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

Assembly and Maintenance Manual Type RSBW

Motorized roller MRA50

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

13 Technical data of the motors

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Chain wheel rolling door drives DKM 170, 250, 350, 500 and 750 WKM 170

Wilo-Control SC-Fire Jockey

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

WBF /-T003 bar magnet insert for Wombat filter housing

Operating Instructions K Always on the safe side.

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Addendum to the Operating Instructions

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Original Operating Manual

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Revision MOVITRAC LTE-B * _1114*

Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B. Revision. Edition 07/ / EN

CENTAFLEX-K Assembly and operating instructions 014K S... M EN Rev. 1

IMPORTANT ATTENTION INSTALLERS:

Operating Instructions INTERROLL Belt Conveyor Type 4081

* _1015* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Drive Unit MGF..-DSM

Operating Instructions

Shaft mounted rolling door drives DFM/DFE 100, 170, 250, 350, 500 and 750 WFM/WFE 170

Addendum to the Assembly and Operating Instructions

Description CMP servomotors are delivered with 2-pole resolvers as standard. Further information on other resolvers is available on request.

Installation. Active Valve Control Control of Exhaust Valves MB W205 C43 AMG C63 (S) AMG

Operating Instructions (Translation)

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

Netzteil Power Supply TPS TPS

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Dash Logger Extension Cable PART# - RS11850-MD60-EC-11. APPLICATION(S): RIVA/Athena Dash Logger with 2011 & Newer Sea Doo 4-TEC Models

INSTALLATION INSTRUCTIONS

MOVIMOT. Operating Instructions Category 3D (Dust Explosion Protection) Edition 03/ X / /011/98

X JET (Counter current system) Instruction Manual

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Operating Instructions

Operating Instructions

INSTALLATION INSTRUCTIONS

The vehicle manufacturer's body fitting guidelines must be adhered to and AMF-Bruns original parts need to be used for the installation!

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

Tri-Clover Manual and Air Actuated Fractional Valves

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Operating Instruction. Junction Box 80 A/125 A. Part-Number BAL a-EN Original document page 1 of 20

Assembly instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Assembly and Maintenance Manual Type ASNU

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

Operating instructions Flow monitor SI / / 2013

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

PHOENIX CONTACT - 01/2008

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Assembly and Maintenance Manual Type AS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

W BW GW. Workshop manual. Mechanical suspensions BPW, series ECO Cargo W / BW / GW. BPW-WH-W-BW-GW e

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

Installation Instructions. PowerFlex 700 Drive - Frame 7 Components Replacement

Extension Boot System

The vehicle manufacturer's body fitting guidelines must be adhered to and AMF-Bruns original parts need to be used for the installation!

Baelz-electrodyn Actuator for modulating duty Motorized linear actuator baelz 373-E45

Installation instructions

Installation instructions

TPM + Bosch Rexroth IndraDrive. Quick Startup Guide D Revision: 02

Revision. Mechatronic Drive System MOVIGEAR DBC-B, DAC-B, DSC-B, SNI-B, * _0315*

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions SEWEURODRIVE GmbH & Co KG P.O. Box 3023 D76642 Bruchsal/Germany Phone +49 7251 750 Fax +49 7251 751970 sew@seweurodrive.com www.seweurodrive.com MOVIMOT MM..D Retrofit Set for AC Motors DRS/DRE/DRP Edition 02/2010 16742419 / EN

1 General Information Structure of the safety notes MOVIMOT Æ MM..D Retrofit Set AC Motor Series DRS/DRE/DRP 1 General Information 1.1 Structure of the safety notes Pictogram Signal word Meaning Consequences if disregarded Example: DANGER Imminent danger Severe or fatal injuries General danger WARNING Possible dangerous situation Severe or fatal injuries Specific danger, e.g. electric shock CAUTION Possible dangerous situation Minor injuries NOTICE Possible damage to property Damage to the drive system or its environment INFOR MATION Useful information or tip. Simplifies the handling of the drive system. 1.2 Right to claim under limited warranty A requirement of faultfree operation and fulfillment of any right to claim under limited warranty is that you adhere to the information in the MOVIMOT documentation. Therefore, read the operating instructions before you start working with the unit. Make sure that the operating instructions are available to persons responsible for the plant and its operation, as well as to person who work independently on the unit. You must also ensure that the documentation is legible. 1.3 Exclusion of liability You must comply with the information contained in the MOVIMOT documentation to ensure safe operation of MOVIMOT and to achieve the specified product characteristics and performance requirements. SEWEURODRIVE does not assume liability for injury to persons or damage to equipment or property resulting from nonobservance of these operating instructions. In such cases, any liability for defects is excluded. 2 Addendum to the Operating Instructions MOVIMOT MM..D Retrofit Set AC Motors DRS/DRE/DRP

General Information Other applicable documentation 1 1.4 Other applicable documentation This additional information does not replace the detailed operating instructions. Only electrical specialists are allowed to perform installation and startup observing applicable accident prevention regulations and the "MOVIMOT MM..D with AC Motors DRS/DRE/DRP" operating instructions. 1.5 Available retrofit sets NOTICE Only (brake) motors are allowed to be retrofitted with: Rated motor voltage AC 230/400 V, 50 Hz Rated brake voltage AC 230 V for MM03 MM15 AC 120 V for MM22 MM40 No retrofit sets are available for UL units. MOVIMOT retrofit sets are configured to order. This is the reason why retrofit sets do not have a part number. 1.5.1 Retrofit sets for DRS motors 1400 rpm 0.37 DRS71S4 MM03D,, DRS DRS71S4/.../MM03D 0.55 DRS71M4 MM05D,, DRS DRS71M4/.../MM05D 0.75 DRS80S4 MM07D,, DRS DRS80S4/.../MM07D 1.1 DRS80M4 MM11D,, DRS DRS80M4/.../MM11D 1.5 DRS90M4 MM15D,, DRS DRS90M4/.../MM15D 2.2 DRS90L4 MM22D,, DRS DRS90L4/.../MM22D 3.0 DRS100M4 MM30D,, DRS DRS100M4/.../MM30D 4.0 DRS100LC4 MM40D,, DRS DRS100LC4/.../MM40D 2900 rpm 0.55 DRS71S4 MM05D,, DRS DRS71S4/.../MM05D 0.75 DRS71M4 MM07D,, DRS DRS71M4/.../MM07D 1.1 DRS80S4 MM11D,, DRS DRS80S4/.../MM11D 1.5 DRS80M4 MM15D,, DRS DRS80M4/.../MM15D 2.2 DRS90M4 MM22D,, DRS DRS90M4/.../MM22D 3.0 DRS90L4 MM30D,, DRS DRS90L4/.../MM30D 4.0 DRS100M4 MM40D,, DRS DRS100M4/.../MM40D Addendum to the Operating Instructions MOVIMOT MM..D Retrofit Set AC Motors DRS/DRE/DRP 3

1 General Information Available retrofit sets 1.5.2 Retrofit sets for DRE motors 1400 rpm 0.75 DRE80M4 MM07D,, DRE DRE80M4/.../MM07D 1.1 DRE90M4 MM11D,, DRE DRE90M4/.../MM11D 1.5 DRE90L4 MM15D,, DRE DRE90L4/.../MM15D 2.2 DRE100M4 MM22D,, DRE DRE100M4/.../MM22D 3.0 DRE100LC4 MM30D,, DRE DRE100LC4/.../MM30D 4.0 DRE132S4 MM40D,, DRE DRE132S4/.../MM40D 2900 rpm 1.1 DRE80M4 MM11D,, DRE DRE80M4/.../MM11D 1.5 DRE90M4 MM15D,, DRE DRE90M4/.../MM15D 2.2 DRE90L4 MM22D,, DRE DRE90L4/.../MM22D 3.0 DRE100M4 MM30D,, DRE DRE100M4/.../MM30D 4.0 DRE100LC4 MM40D,, DRE DRE100LC4/.../MM40D 1.5.3 Retrofit sets for DRP motors 1400 rpm 0.75 DRP90M4 MM07D,, DRP DRP90M4/.../MM07D 1.1 DRP90L4 MM11D,, DRP DRP90L4/.../MM11D 1.5 DRP100M4 MM15D,, DRP DRP100M4/.../MM15D 2.2 DRP100L4 MM22D,, DRP DRP100L4/.../MM22D 3.0 DRP112M4 MM30D,, DRP DRP112M4/.../MM30D 4.0 DRP132M4 MM40D,, DRP DRP132M4/.../MM40D 2900 rpm 1.1 DRP90M4 MM11D,, DRP DRP90M4/.../MM11D 1.5 DRP90L4 MM15D,, DRP DRP90L4/.../MM15D 2.2 DRP100M4 MM22D,, DRP DRP100M4/.../MM22D 3.0 DRP100L4 MM30D,, DRP DRP100L4/.../MM30D 4.0 DRP112M4 MM40D,, DRP DRP112M4/.../MM40D 1.5.4 Braking resistors for motors without brake For motors without mechanical brake, we recommend to connect an integrated braking resistor BW... The braking resistor is not included in the scope of delivery of the retrofit set and must be ordered separately: MOVIMOT type Braking resistor Part number MM03D to MM15D BW1 0 822 897 3 1) MM22D to MM40D BW2 0 823 136 2 1) 1) The scope of delivery includes 2 screws M4 x 8. 4 Addendum to the Operating Instructions MOVIMOT MM..D Retrofit Set AC Motors DRS/DRE/DRP

Mechanical Installation Scope of delivery of the retrofit set 2 2 Mechanical Installation 2.1 Scope of delivery of the retrofit set Check the scope of delivery of the MOVIMOT MM03D MM40D retrofit set for completeness using the following figure. [A] [B] [C] [D] [E] [F] [G] [J] [I] [A] Terminal box gasket [E] PE screw [I] DriveID module [B] Connection box [F] Connection cable [J] 2 screws [C] 4 screws [G] Cover with inverter [D] Connection pcb [H] 4 screws Parts [B] and [D] through [J] are already installed when the retrofit set is delivered. [H] 783979147 2.2 Assembly DANGER Disconnect the drive from the power supply before removing the terminal box cover. Severe or fatal injuries from electric shock. Disconnect the drive drive from the supply system and secure it against unintentional reconnection to the voltage supply. Then wait at least for 1 minute. 1. Unscrew the terminal box cover and remove the power supply cable. Result as shown in the figure to the right: * Brake control, optional (only with brakemotors) * 9007200042328587 Addendum to the Operating Instructions MOVIMOT MM..D Retrofit Set AC Motors DRS/DRE/DRP 5

2 Mechanical Installation Assembly [1] [2] [3] [4] 9007200042336011 2. If present, disconnect the brake control cables [1] and [2]. 3. Remove the nuts [4] and jumpers [3]. [7] [6] [5] [A] [B] 9007200042421003 4. Unscrew the lower part of the terminal box [5]. 5. Remove the gasket [6]. 6. Clean the sealing surface [7]. 7. Place the new gasket [A] onto the terminal box [B]. 6 Addendum to the Operating Instructions MOVIMOT MM..D Retrofit Set AC Motors DRS/DRE/DRP

Mechanical Installation Assembly 2 8. Place the connection box [B] onto the motor and secure it using 4 screws [C]. (Tightening torque 3.1 5.3 Nm / 29 47lb.in) Check that the gasket is fitted correctly. The recess for the terminal board on the underside of the connection terminal must point toward the fan guard. [B] [C] 9. Plug the connection cables [F] onto the bolts of the terminal board as shown in the wiring diagram. Tighten the connection cables using the previously unscrewed nuts. (Tightening torque 1.6 2.0 Nm / 14 18 lb.in) YE WH BN 9007200042429195 10.Connect the connection cables [F] to the terminals [1] on the connection board according to the wiring diagram to the right. BU RD BK W2 U2 V2 W1 V1 U1 YE WH BN BU RD BK [F] [1] 11.Insert the connection board [D] into the terminal box and secure it using 2 screws [J]. (Tightening torque 2.0 3.3 Nm / 18 29 lb.in) 9007200043039883 Be careful not to damage or squeeze the cables. [D] [J] 788423563 Addendum to the Operating Instructions MOVIMOT MM..D Retrofit Set AC Motors DRS/DRE/DRP 7

X1: 13 X1: 14 X1: 15 X1: 13 X1: 14 X1: 15 2 Mechanical Installation Assembly 12.Only for brakemotors: Connect the connection cables of the BE.. brake as follows: Red to terminal X1:13 White to terminal X1:14 Blue to terminal X1:15 (Tightening torque of the terminals 0.8 1.1 Nm / 7 10 lb.in) RD WH BL BE 13.Only for motors without a brake: Install the BW.. braking resistor in the terminal box using 2 screws. (Tightening torque 1.4 1.6 Nm / 12 14 lb.in) 9007200043226123 Connect the BW.. braking resistor to terminals X1:13 and X1:15. (Tightening torque of the terminals 0.8 1.1Nm / 7 10lb.in) Terminal X1:14 must not be assigned. BW1 / BW2 14.Place the MOVIMOT inverter onto the terminal box and secure it using 4 screws. (Tightening torque 3.0 Nm / 27 lb.in) 9007200043479691 2602175499 After successful retrofitting, startup the MOVIMOT drive according to the "MOVIMOT MM..D with AC Motors DRS/DRE/DRP" operating instructions. 8 Addendum to the Operating Instructions MOVIMOT MM..D Retrofit Set AC Motors DRS/DRE/DRP