ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

Similar documents
ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZK4-PE PI-Spring Terminal Blocks Ground

ZS4-PE Screw Clamp Terminal Blocks Ground

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS10 Screw Clamp Terminal Blocks Feed-through

ZK6 PI-Spring Terminal Blocks Feed-through

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS50-PE Screw Clamp Terminal Blocks Ground

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZDP Pluggable Terminal Blocks Feed-through

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZP2.5-PE Spring Terminal Block Ground

ZP2.5-4P Spring Terminal Block Feed-through

DBL distribution blocks 3x1 pole

ZS4-SF1 Screw Clamp Terminal Block

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Thermal overload relay TF140DU and TF140DU-V1000

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starter MS116

Thermal overload relay TF65 and TF96

MS General Information Extended Product Type: MS

Manual motor starter MS132

Thermal Overload Relays

Mini contactors B6, BC6 with 3 pole

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Manual motor starter MS116

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

AF40... AF96 3-pole contactors Technical data

Manual motor starter magnetic only MO325

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DX³ RCCBs - ID 4P up to 100 A

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Manual motor starter MS132

Manual motor starter MS132

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

RX 3 M.C.B A up to 63 A

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

RX 3 M.C.B A up to 63 A

TX³ RCCBs 2P up to 100 A

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Data sheet. W-Series WDU 4 SL/EN

Phase + Neutral, neutral on left side

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

AE 9... AE 40 Contactors NE... Contactor Relays

up to 63 A (1 module per pole)

Overloadrelay,10-16A,1N/O+1N/C. Articleno

DX³ 4-pole RCBO 6000 A/10 ka

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

ABB i-bus KNX DG/S x DALI-Gateway Basic

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Data sheet... W-Series WPE 4

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Transcription:

Technical Datasheet 1SNK16D01 Catalogue Page 1SNK1641S01 ZK.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: - Rail contact non operator dependent, - Performances above the requirements of the IEC 60947-7- terminal block standard, - Secured snap on or off the rail, - Profile aligned with ZK.5-4P. 1SNK16V0014 1SNK0159F0000 D CAD outline drawings available on "Control Product D" portal 1SNC0565 F0000 PI-Spring Terminal Blocks.5 mm² 1 AWG Ordering Details Color Green-yellow Type Order Code EAN Code 5. mm 0.5 in Spacing Pack (ing) Weight (1 pce) reen-yellow ZK.5-PE-4P 1SNK70515R0000 4759705154 1.6 g CE CB RoHs USR CNR CSA GOST R ATEX IECEx BV ATEX Declaration

CE CB RoHs USR CNR CE CB RoHs USR CNR 1SND5151C* 1SND1617A0* 1SND055F0* 1SND161A0* CSA CSA 1SND1614A0* GOST R GOST R 1SND1605A11* ATEX ATEX 1SND1609A17* IECEx IECEx 1SND16A17* BV BV 1SND161A0* Atex Declaration Atex Declaration 1SND5C* Explosive Atmosphere: ATEX Classification Group Category IM II GD Ex eb I/IIC/IIIC Protection Method Ex e: increased security In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D General Information The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail Wire stripping length IEC 60947-1 TH 5-7.5, TH 5-15 Denudage IP TH 5-7.5, TH 5-15 11 mm NEMA 0.4 in Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver.5 mm 0.1 in Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL94 V0 NF F 161 IF Connecting capacity per clamp 1 Rigid - Solid / Stranded conductor 1 Flexible conductor 1 Flexible conductor with non insulated ferrule 1 Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter Needle flame testec 60615-11-5 Compliant PI Spring IEC60947-7- UL59 0.... 4 mm² 6... 1 AWG IEC60947-7- 0.....5 mm² 0.....5 mm² 6... 14 AWG 0.....5 mm² 6... 14 AWG.4 mm IEC 60947-1 Ferrule 4.65 mm The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS- (crimping capacity up to mm²). Technical Datasheet 1SNK16D01 ABB

Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors Flexible conductors Flexible conductors with twin ferrule Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS- (crimping capacity up to mm²) Cross section Rated cross section IEC60947-7-.5 mm² UL59 1 AWG Maximum Cross section 4 mm² 1 AWG Electrical characteristics Current Rated current IEC60947-7- Field and factory wiring Cat. UL 59 Factory wiring Cat.1 UL 59 CSA-C-. n 15 Maximum Exe current IEC/EN 60079-7 Rated short-time withstand current 1 s (Icw) Short-time withstand current 0.5 s 5 s s 0 s 1 min IEC60947-7- 00 A Rated short-circuit withstand current CSA-C-. n 15 Max. current (45 temperature increase) / Max. cross section (mm²) Maximum short circuit current (1s) 00 A 4 mm² Short Circuit Current Rating (SCCR) SA UL 59 supplement SCCR UL 59 With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating J T RK1 RK5 G CC Voltage Rated voltage IEC 60947-1 Rated voltage UL 59 Use Group UL 59 B, C, D Rated voltage CSA-C-. n 15 Rated voltage Ex e IEC/ EN 60079-7 Rated impulse withstand voltage IEC 60947-1 000 V Dielectric test voltage IEC 60947-1 0 V Pollution degree IEC 60947-1 Overvoltage category IEC 60947-1 III ABB Technical Datasheet 1SNK16D01

Temperature range Ambient temperature min/max Storage -55... +1 C Installing -5... +40 C Service -55... +1 C -67... +0 F -... +4 F -67... +0 F Current Derating curve for continuous service temperature Dissipated power Maximum dissipated power at rated current IEC 60947-1 Maximum dissipated power at maximum Exe current IEC 60079-7 Rated power dissipation at an ambient temperature of C - IEC 60947-7- Separate arrangement / Overload and short-circuit protection Separate arrangement / Exclusive short-circuit protection 1 fuse and 4 feed-through blocks Compound arrangement / Overload and short-circuit protection Compound arrangement / Exclusive short-circuit protection 5 fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 6006- Compliant Temperature 1 C Duration of test 96 h IEC 6006-0 Compliant Temperature 55 C Relative humidity 95 % Number of cycles (1 cycle = 4h) IEC 6006-1 Compliant Temperature -55 C Duration of test 96 h IEC 6006--7 Compliant Temperature 40 C Relative humidity 9 % Duration of test 96 h Corrosion Salt mist IEC 6006-11 Duration of test Concentration ISO 69 SO Compliant Duration of test 4 h Concentration 0. dm³ Flowing mixed gas corrosion test IEC 6006-60 Compliant Number of the test method Duration of test Compliant 00 h 5 % 1 j 4 Technical Datasheet 1SNK16D01 ABB

Vibrations and shocks Sinusoidal vibrations Functional random vibrations Category 1 Class B axes Long life testing at increased random vibrations Category 1 Class B axes Shock Category 1 Class B axes IEC 6006--6 Compliant Frequency range 5... 0 Hz Number of cycles 1 Acceleration 7 m/s² IEC 617 Compliant Duration of test mn Frequency range 5... 1 Hz Acceleration 1 m/s² IEC 617 Compliant Duration of test 5 h Frequency range 5... 1 Hz Acceleration 5.7 m/s² IEC 617 Compliant Duration of test 0 ms Acceleration 5 G ZK.5-PE-4P Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. Description Type Order Code Pack (ing) Weight pieces g (1 pce) 1 End Stops BAM 1SNK900001R0000 1.0 1 1 4 5 6 6 7 7 9 End Stops End Stops End Sections Cross Spacing Jumpers Circuit Separators Test Adapters Test Adapters Test Connectors Test Connectors Tools BAZ1 BAZH1 EK.5-4P JB5- JB5- JB5-4 JB5-5 JB5- JB5- JB5- CS-R TP TP4 TC5 TC5-R1 PR.G PR4 PR5 PR0 PR.Z PR PS- MC51 MC51-YL MC51PA PROCAP5 UMH SAT5 1SNK90000R0000 1SNK900R0000 1SNK70591R0000 1SNK90R0000 1SNK90R0000 1SNK904R0000 1SNK905R0000 1SNK905R0000 1SNK905R0000 1SNK90060R0000 1SNK9007R0000 1SNK900R0000 1SNK9005R0000 1SNK9000R0000 1SNK9001R0000 1SNA16400R000 1SNA160R10 1SNA16700R0 1SNA17R00 1SNA17400R1700 1SNA1759R0400 1SNK9006R0000 1SNK140000R0000 1SNK140004R0000 1SNK149999R0000 1SNK900609R0000 1SNK900611R0000 1SNK900614R0000 0 1 5 5.0.90.7 1.0.00.70. 7. 6..0 6.4 1.7.41 5. 5. 915.00.00 1.00 0.00 9.00 9.00.00 0.69 0. 6.00 ABB Technical Datasheet 1SNK16D01 5

1SNK16D01 - PDF Contact us ABB France Low Voltage Products Division Export Department, rue Ampère Z.I. - B.P. 114 F-6965 Chassieu cedex / France Tel. + (0)4 7 17 Fax + (0)4 7 195 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties written consent of ABB. Copyright 11 ABB All rights reserved