HEATING & CHILLED SYSTEM PRESSURISATION UNITS AQUAPACK ET SERIES

Similar documents
COLD WATER BOOSTER SETS

AQUAMATIC HY-AV 2020Plus SERIES

Associated controllers Controller selection

ELECTRONICS TRANSFORMERS SWITCHING POWER SUPPLIES

PCU CORE FIRE PROTECTION ELECTRICAL DETAIL

ELECTRONIC TRANSFORMERS SWITCHING POWER SUPPLIES


VQD: 2-way flanged valve, PN 6

The Mikrofill Electronic Filling Device. (EFD)

Full Port Ball Valves

VUP: Pressure-relieved 2-way flanged valve, PN 25 (el.)

M Point & 3-Point Electric Damper-Actuator

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION

VQE: 2-way flanged valve, PN 16

DATA SHEET LC-D CONTACTORS

Symbol indicating an action that must not be done. Symbol indicating an action that should be done. Symbol indicating related or useful information

Z SLIDERS. Introducing a low profile actuator installing a circulating type linear guide!

Hydronic Accessories H YDRONIC C OMPONENTS & S YSTEMS. Taco Catalog # Supersedes: Dated: 02/1/01

Three Way Ball Valves

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

BUG: 3-way flanged valve, PN 25/16 (el.)

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Access Rectangular In-Line Fans (ARH)

www. ElectricalPartManuals. com l Basler Electric DGC-1000 DIGITAL GENSET CONTROLLER DESCRIPTION and SPECIFICATIONS pages 2 and 3

76.126/1. BUS: Flanged three-way valve, PN 40. Sauter Components

Axial fans Product-specific information

www. ElectricalPartManuals. com Westinghouse

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

Standby Amper VOLTAGE

Nickel Cadmium Battery

Diaphragm Seals NEW! For Pressure Products For Pressure Products

Three-phase Induction Motors. Empowering the Future

Pent-A-Boost Compact Domestic Booster Sets

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Product description. EM converterled

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

VEGETABLE CUTTING MACHINE OPERATION MANUAL TT-F60 / TT-F65 TT-F60 TT-F65

Low-watt Type Solenoid Valve

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Datasheet. Flamcomat - Pressureless Expansion System

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

V6R: 2-way valve with female thread, PN 16 (el.)

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.


TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Illuminator Series CR NEMA 3R

DIESEL Engine Fire Pump Controllers Features

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Characteristics TeSys contactors 0 Model d

Standby Amper VOLTAGE

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Standby Amper VOLTAGE

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Technical Data Sheets

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

V6R: 2-way valve with female thread, PN 16 (pn.)

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Technical Data Sheets

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

B BASIC HEAT TREATMENT CONSOLE

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

SAF MODUL t AIR SUSPENSION SYSTEM WITH DISC AND DRUM BRAKE 17.5, 19.5 AND 22.5

Load Capacity (inertia vs. time) 2 Stop

AQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

CM707 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

RVS-DN Digital Reduced Voltage Motor Starter

HIGH CAPACITY COILS UNIT CONNECTION SIZES CONNECTION SIZES B C CONNECTION SIZES

Standby Amper VOLTAGE

Industrial Chargers and

SCHEDULE DISTRIBUTION USE OF SYSTEM CHARGES

Boost-A-Break - Break Tank & Booster Sets

X-M 6, X-W6, X-F 7, X-M 8, M 10, W 10 Threaded Studs for Concrete

SCHEDULE DISTRIBUTION USE OF SYSTEM CHARGES

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

DIESEL GENERATOR SETS

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

EFFEKTA Power Supplies

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

DIESEL GENERATOR SET. 60 Hz FEATURES

Technical specification

DEEP SEA ELECTRONICS PLC

DKG-114 MANUAL AND REMOTE START UNIT

lubrication systems CME Electric pump for oil and soft grease volumetric

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Transcription:

For more information on AquaTeh Pressmain visit www.barbourprodutsearh.info HEATING & CHILLED SYSTEM PRESSURISATION UNITS AQUAPACK ET SERIES group member Datasheet No: Issue No: Date: 207 9 03/12/07

For more information on AquaTeh Pressmain visit www.barbourprodutsearh.info AQUAPACK ET Single or twin pump Pressurisation Unit with Miroproessor Control STANDARD FEATURES: Boiler ratings up to 5000kW @ 82 C System ontents up to 50,000 litres Temperature range up to 120 o C (when using intermediate ooling vessel) Cold fill pressure 1.2 bar to 3.0 bar (ET45) or 3.0 bar to 7.0 bar (ET90) Reliable 2000Plus Miroproessor/transduer ontrol Boiler / Chiller safety interlok relay Audible alarm with mute & reset operates on high & low pressure Expansion vessels - tested to BS6144 - max working pressure 10 bar Twin pump models with duty/standby pumps & automati alternation of duty pump to even wear Enhaned models are fully ompatible with Building Management Systems Fluid atagory 3 (water supply regulations 1999) Built to latest CE requirements and in aordane with ISO9001 OPTIONAL FEATURES: C1 abinet unit enlosing pumps, break tank and ontrols (an be floor or wall mounted) Leak detetion via frequeny of starts alarm SPECIFICATION FOR AQUAPACK PRESSURISATION UNITS FOR HEATING & CHILLED WATER APPLICATIONS GENERAL The Aquapak ET Series pressurisation unit is designed to maintain a minimum set pressure in a sealed heating or hilled water system. One the system has been initially filled via a quik filling loop, should the pressure fall below the old fill pressure the unit operates automatially to restore that pressure. If high or low-pressure onditions should our the boiler/hiller operation an be interrupted via the volt-free ontats provided. The unit is used in onjuntion with a suitably sized expansion vessel from our Aquatank range of replaeable diaphragm vessels tested to BS6144. All pakaged equipment is manufatured in aordane with ISO9001 quality assurane proedures. STANDARD SPECIFICATION AquaTeh ET series, heating or hilled water pressurisation unit. Suitable for old fill pressures up to 3.0 bar/45psi ET45 and 7.0 bar/98psi with ET90 model. Controlled by AquaTeh 2020Plus miro-proessor ontroller with pressure transduer for long-term reliability and auray, n-volatile EPROM memory and data logging funtion. Fully pakaged unit irporating; single or twin pressurisation pumps, (auto hange-over to even wear with twin pump models); Solid state pump drives with thermal overload protetion; Automati periodi pump pulsing to prevent pump seizure; Combined high/low system pressure ut-out relay volt-free ontat; RS232 or 422/485 serial ommuniations port; 18-litre mains water break-tank with 15mm float valve having a type AA air gap to Water Supply Regulations 1999; Fasia ontrols to provide indiating lights for eah pump ondition or status, run, hand, off, auto; User friendly Fasia keypad to enter & set operational parameters, reset alarm & mute; Plain English 2 Line LCD illuminated display. Automati ut-out and reset on tank low water level to prevent pump from dry running, 8 BMS Volt free relay onnetions, Fasia lights for pump tripped ondition. All ontrols ontained within a powder oated sheet steel dust and damp proof enlosure to IP54, with interloking door isolator. Optional C1 abinet models have all ontrols and interonneting piping and wiring ontained within the abinet. 2ET45 Eletrial supply: Single Phase, 240 Volt AC, 50Hz, 6 Amp; Max power: 0.74kW

For more information on AquaTeh Pressmain visit www.barbourprodutsearh.info QUICK SELECTION Example: 4 storey building with 400 kw boiler power running at a temperature of 80 C Flow and 70 C Return. The plantroom is on the ground floor. From hart 1; From hart 2; Superimposed pressure at 80 C is bar. Stati height is taken as 4 storeys at 3 metres per floor = 12 metres = 1.2 bar. Plus superim posed pressure of bar (from hart 1) equals 1.4 bar, whih is our low pressure alarm point. Add bar for support pump start, plus bar for duty pump start, plus bar for duty pump stop. therefore old fill pressure = 1.2 + + + + = 2.0 bar. From hart 3; Cross referene 400 kw boiler power (assuming 10 litres per kw for system ontent) with 2.0 bar old fill pressure, gives pressurisation unit model 1ET45 or 2ET45 (twin pump) From hart 4; Cross referene 400 kw with boiler flow temperature of 82 C gives expansion vessel size 500VR. Model seleted: Aquapak 1ET45, or 2ET45 for twin pump unit, omplete with 500VR expansion vessel. CHART 1 EXPANSION & SAFETY PARAMETERS FOR HEATING PRESSURISATION UNITS CHART 2 PRESSURE SETTINGS CHART FOR HEATING SYSTEM PRESSURISATION EQUIPMENT FLOW TEMPERATURE C EXPANSION PERCENTAGE % SUPERIMPOSED PRESSURE BAR 40 0.78 50 60 70 80 90 105 110 115 120 1.21 1.71 2.28 2.91 3.60 4.35 4.77 5.15 5.62 6.01 0.3 0.6 0.9 1.3 1.7 125 130 135 140 145 150 6.52 7.00 7.50 8.00 8.53 9.06 2.2 2.7 3.2 3.7 4.4 5.1 LTHW MTHW HTHW LOW PRESSURE CUT-OUT SETTING (STOPS BOILERS AND RAISES ALARM) 20000 15000 ZERO 0.0 METRES (GAUGE PRESSURE) DUTY PUMP STOP = COLD FILL PRESSURE DUTY PUMP START (SETPOINT) & SUPPORT PUMP STOP SUPPORT PUMP START MAXIMUM WORKING PRESSURE OF BOILER AND SAFETY VALVE HIGH PRESSURE CUT-OUT SETTING (STOPS BOILERS AND RAISES ALARM) NORMAL WORKING PRESSURE OF SYSTEM SUPERIMPOSED PRESSURE' ADDED TO ENSURE HEATING CIRCUIT IS ALWAYS FULL AND DOES NOT FLASH OVER TO STEAM AT HIGH FLOW TEMPERATURES STATIC HEIGHT' OF UPPER MOST PART OF HEATING CIRCUIT, ABOVE PRESSURISATION UNIT, MEASURED IN BAR PRESSURE RISE DUE TO EXPANSION / TEMPERATURE STATIC HEIGHT SUPERIMPOSED PRESSURE CHART 4 EXPANSION VESSEL SELECTION COLD FILL PRESSURE IN BAR 7.0 6.0 5.0 4.0 3.0 2.0 1.0 20 CHART 3 PRESSURISATION UNIT SELECTION 40 60 ET90 ET45 200 400 600 0 2000 BOILER POWER IN kw BASED ON 10 l/kw @ 82 C 4000 6000 00 20000 EXPANSION VOLUME OF SYSTEM IN LITRES 00 5000 4000 3000 2000 0 500 400 300 200 50 40 30 20 10 200 300 400 500 SYSTEM CONTENT IN LITRES 0 2000 3000 4000 5000 00 120 C (MTHW) Boiler Flow Temperature 90 C (LTHW) Boiler Flow Temperature 82 C (LTHW) Boiler Flow Temperature 30 C ambient - Chilled system with 35% Glyol 30 C ambient - Chilled system with 20% Glyol 30 C ambient - Chilled system with 0% Glyol 20000 30000 40000 50000 70000 000 150000 3x 4x AQUAPACK 60VR VR 200VR 300VR 500VR 2x500VR NOT ECONOMIC FOR AQUAPACK RANGES 500VR 500VR 10 20 30 40 50 200 300 400 500 BOILER/CHILLER POWER IN kw FOR MEDIUM CONTENT SYSTEMS (10l/kW) 0 2000 3000 4000 5000 7000 00 3

For more information on AquaTeh Pressmain visit www.barbourprodutsearh.info ET PRESSURISATION UNIT TYPES Having seleted the model required for your projet, below are various different model types to hoose from:- AQUAPACK MODEL REFERENCES 1 OR 2 ET XX -Y- ZZZ -E 1 = SINGLE PUMP 45 = 2 = TWIN PUMP SEALED SYSTEM 90 = PRESSURISATION UNIT, MICROPROCESSOR CONTROLLED TWIN PUMP UNITS OF- FER % STANDBY WITH AUTOMATIC DUTY ROTATION COLD FILL PRESSURES 1.2 TO 3 BAR COLD FILL PRESSURES 3 TO 7 BAR BLANK P = LOOSE EXPANSION VESSELS CABINETISED CONTROLS & C1 = PUMP/S SEE SELECTION CHART 3 SEE SELECTION CHART 4 SEE PAGE 2 C2 = = PACKAGED ON BASE WITH EXPANSION VESSELS FULL CABINET INCLUDING EXPANSION VESSEL VESSEL SIZE WHEN PACKAGED ON A BASE (I.E. P, C1 & C2 MODELS) BLANK = E = STANDARD CONTROLS SPEC ENHANCED CONTROLS SPEC. FOR BMS 2ET45-P-500-E 2ET45-C1-E Twin pump pakaged unit with 500VR expansion vessel all on base Twin pumps with ontrols & breaktank in abinet. Supplied with loose expansion vessels or all on base FASCIA DISPLAYS & BMS OUTPUTS OPERATIONAL DATA DISPLAY: System Pressure System Status Inluding Warnings Alarms With Type of Fault Pump/s Tripped Transduer Fault Boiler/s Cut-out INFORMATION DISPLAYS: Hours Run for Eah Pump Hours Elapsed Sine Last Servie Parameter Settings Display High Pressure Cut-out Setting Pump Stop (Cold Fill Pressure) Low Pressure Cut-out Setting Support Pump Delay Time *WARNING DISPLAYS: High Pressure Approah Low Pressure Approah High Water Level Approah Low Water Level Approah Serviing Reminder BMS VOLT FREE RELAY CONNECTIONS High System Pressure Low System Pressure Low/High Water Level Exessive Frequeny of Start/Demand Pump Tripped/Failed Transduer Fault Common Warning Signal for all Warning Displays* Boiler/Chiller Cut-out Note: Standard ontrol speifiation inludes fasia keypad & LCD display with information & warning displays as above (exluding water level alarms & pump/s tripped), plus boiler / hiller volt free relay onnetion only. 4

For more information on AquaTeh Pressmain visit www.barbourprodutsearh.info ELECTRICAL CONNECTIONS (ENHANCED UNIT) A1 F1 Pump1 T1A A2 A3 F2 Pump2 T1A B1 B2 B3 High Pressure Low Pressure High/Low Water Pump Starts Exessive Pump Failed Transduer Failed Common Warning Boiler Cut-out n n n n n A B C D E F GH J K L M N OP R S T U VW X Y Z n n n 0V 12VAC BMS volt free outputs max 240VAC 50Hz 1.5A 2000PLUS MOTHERCARD 24VAC L N E 1 5 3 7 Isolator IS1 2 6 4 8 Typial Boiler Interrupt Ciruit n X Y Z SUPPLY IP1 IP2 4 Channel 4-Channel Analogue Level Input Sensing Module Module Control thermostat Pressure fault Control relay N Boiler/burner ontrols WIRING BY CUSTOMER TYPICAL SCHEMATIC LAYOUT DIAGRAM FOR ET SERIES Water supply with isolating valve Control Panel System onnetion if vessels supplied IMPORTANT Make onnetion to UNDERSIDE of system pipework, at a point on sution side of irulating pumps and boilers Expansion vessel(s) when supplied System onnetion if ooling vessel is supplied HOT Cooling Vessel when supplied Overflow warning if required Drain off ok COOL System onnetion if expansion vessel(s) supplied Installer to provide WORK REQUIRED ON SITE Bolt baseplate to plinth Fit float valve into tank in the best position to suit onditions and provide type AA air gap if required. Connet ½ BSP (15mm) mains water supply. Provide and fit ¾ BSP (22mm) overflow pipe from break tank to suitable drain. Wire single phase ontrol supply onto terminals provided and boiler/hiller thermostat ontrol iruits onto boiler/ hiller relay within the ontrol panel. Connet AQUAPACK unit to system as installation instrutions. 5

For more information on AquaTeh Pressmain visit www.barbourprodutsearh.info AQUAPACK ET 2020PLUS SERIES PACKAGED UNIT DIMENSIONS Control Panel Supply 240VAC 1Ph 50Hz H System Connetion (Module B) 1/2" Float Valve /w Type "AA" Air Gap 18 Litre Mains Water Tank Pressurisation Pumps System onnetion (Module A) 22mm Overflow Warning Pipe Foot Valve & Strainer Lokshield Valve W OW Drain Cok MODULE A = Pump & Controls Unit Only, For Use With Module C or Free Standing Vessels (see page 8) MODULE B = Pump & Controls Unit With 1 Expansion Vessel MODULE C = 2 x 500 Litre Expansion Vessels A MODULES B C POSSIBLE CONFIGURATION OF VESSELS L OL (With Control Panel Door Open) 0 vessel A 1 vessel B 2x500 vessels A+C 3x500 vessels B+C 4x500 vessels A+C+C 5x500 vessels B+C+C Model Referene Pump & Controls Module Only (loose vessel) 1ET45 2ET45 1ET90 2ET90 2 x 500 (vessels only) No. of Vessels Module Base Overall Max. L W OL OW H System Connetion Weight Kg. 0 A 480 450 670 450 1025 ½" BSP 50 -P-60 1 x 60 B 1 450 1290 450 1025 1" BSP 78 -P- 1 x B 1 450 1290 485 1025 1" BSP 95 -P-200 1 x 200 B 1 450 1300 640 1025 1" BSP 110 -P-300 1 x 300 B 1 450 1300 640 1320 1" BSP 125 -P-500 1 x 500 B 1 450 1400 745 1520 1" BSP 150 -P-2-500 2 x 500 A + C 2270 745 1520 1¼" BSP 220 -P-3-500 3 x 500 B + C (refer to individual 1600 1490 1520 1½ BSP 320 -P-4-500 4 x 500 A + C + C module dimensions) 2270 1490 1520 1½ BSP 390 -P-5-500 5 x 500 B + C + C 2350 1490 1520 1½ BSP 418 2 x 500 C 1600 620 1600 745 1520-170 All dimensions in mm unless stated otherwise

For more information on AquaTeh Pressmain visit www.barbourprodutsearh.info AQUAPACK AQUAPACK ET ET 2020PLUS 2000PLUS SERIES SERIES C1 C1 UNIT UNIT DIMENSIONS DIMENSIONS Control Panel Supply 240VAC 1Ph 50Hz H PCB1 Interfae ard TX1 IS1 Pressurisation Pumps Lokshield valve System onnetion (Module A) System Connetion (Module B) 18 Litre Mains Water Tank 1/2" Float Valve /w Type "AA" Air Gap 22mm Overflow Warning Pipe Lokshield Valve W Foot Valve & Strainer OW Drain Cok MODULE A = Pump & Controls Unit Only, For Use With Module C or Free Standing Vessels (see page 8) MODULE B = Pump & Controls Unit With 1 Expansion Vessel MODULE C = 2 x 500 Litre Expansion Vessels A MODULES B C POSSIBLE CONFIGURATION OF VESSELS 0 vessel A L OL (With Control Panel Door Open) 1 vessel B 2x500 vessels A+C 3x500 vessels B+C 4x500 vessels A+C+C 5x500 vessels B+C+C Model Referene Pump & Controls Module in Cabinet (loose vessel) 1ET45 2ET45 1ET90 2ET90 No. of Vessels Module Base L W OL OW H 0 A 380 620 980 620 840 ½" BSP 50 -C1-60 1 x 60 B 1 620 1390 620 840 1" BSP 78 -C1-1 x B 1 620 1460 620 885 1" BSP 95 -C1-200 1 x 200 B 1 620 1620 640 1020 1" BSP 110 -C1-300 1 x 300 B 1 620 1620 640 1320 1" BSP 125 -C1-500 1 x 500 B 1 620 1720 745 1520 1" BSP 150 -C1-2-500 2 x 500 A + C 2580 745 1520 1¼" BSP 220 -C1-3-500 3 x 500 B + C (refer to individual 1720 1490 1520 1½ BSP 320 -C1-4-500 4 x 500 A + C + C module dimensions) 2580 1490 1520 1½ BSP 390 -C1-5-500 5 x 500 B + C + C 2470 1490 1520 1½ BSP 418 2 x 500 (vessels only) 2 x 500 C 1600 620 1600 745 1520-170 All dimensions in mm unless stated otherwise 7 Overall Max. System Connetion Weight Kg.

For more information on AquaTeh Pressmain visit www.barbourprodutsearh.info EXPANSION VESSEL DIMENSIONS (WHEN SUPPLIED LOOSE) AQUATANK VR Series: The diaphragm vessels for speial appliations; Meets or exeeds EC rms for pressure vessels 97/23/EC; Max working pressure: 10 bar; Vessel Material: Steel RSt 37-2.; All vessel parts in ontat with water are oated against orrosion; Diaphragm: Made of speial high quality rubber material; Filling Valve: Shraeder-valve-type; Surfae Treatment: Blue, durable powder oating finish. Type 25 HR 60 VR VR 200 VR 300 VR Nominal Content litres 25 60 200 300 D mm 295 409 480 634 634 D1 mm 228 - - - - H mm 485 740 840 980 1280 Water Connetion DN BSP 1 1 1 1 ¼ 1 ¼ Dry Weight Kg 5.6 25 32 50 55 Max. working Pressure-bar 10 10 10 10 10 D H 60 VR 300 VR H D 25 HR DN DN D1 CONSTRUCTION STANDARDS FOR AQUAPACK ET SERIES ITEM MODEL/SERIES STANDARD/CLASS REMARKS Quality System Manufaturing ISO 9001: 1994 Cert No. FM33090 Wiring Standards BSEN 60204: Part 1:1998 Mahinery Diretive European Diretive 89/392/EEC: 1994 EMC Diretive European Diretive 89/336/EEC: 1992 Mains Water Breaktank 18 Litres Nominal Capaity WRC Approved Mains Float Valve BS1212 part 2 0.5" Type 'AA' Air Gap Pipework Release Nylon Tubing Pipe Fittings TUV 9205-8323-501 Pumps P4 (ET45) / P7 (ET90) 240v, 1 ph, 50hz Pump Motors P4 (ET45) / P7 (ET90) TEFC IP44, Class F Insulation Thermal Overload Proteted Control Cabinet P & C1 IP54 Interloked Door Isolator LA2 & LA3 BS, UL, CSA, VDE, IEC Miroproessor Enhaned 2000+ Motherard 89/336/EEC Transduer Control 392 SS/Cerami 8 Bar Max. Test Pressure The information in this speifiation is orret at time of issue; as AquaTeh Pressmain design and development programmes are ontinuous, we reserve the right to make any hanges to this speifiation without prior tie. Leaders in the design, manufature and assembly of pakaged fluid pumping equipment and ontrol systems. Appliations: Cold Water Supply; Fire Fighting; Heating & Chilled System Pressurisation; Tank Level Monitoring.