ZG 521 Padvault Three-Phase Transformer

Similar documents
UNDERGROUND CONDUIT SYSTEMS for Primary and Secondary Conductors (Rev. 7)

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

COMMERCIAL QUICK REFERENCE

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

OBE-3-FT Outdoor Series

Electric Utility Applications. The Right Enclosure The Right Location The Right Application

Three-Phase Pole Mounted Recloser

Section 6 Electric Metering: Residential

EMERGENCY GENERATOR SET

Fertilizer Type B 2 CWT $ $ $60.00 $ $60.00 $ Sod Water 60 MGAL $60.60 $3, $30.00 $1, $30.00 $1,

SECTION 17 FIRE HYDRANT ASSEMBLIES General

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

1. General Requirements

FROM B.C. HYDRO ENCLOSURE (SEE NOTE 4) RIGID CONDUITS (SEE NOTE 8) ALTERNATIVE TO LOAD BARRIER (SEE NOTE 7) SERVICE ENTRANCE ENCLOSURE

10 Commercial, Industrial, Agricultural Services

5. Contractor Information 3M Model 2300 Series System Layout Checklist

Pretest Module 24 Three-phase Service Entrance

LIFT STATION 11 ONE-LINE DIAGRAM

BUCKEYE LEGACY POLISHED CONCRETE ENHANCER & PROTECTANT MODEL SPECIFICATION

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

CHAPTER 1C PREPARING FOR INSTALLATION

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

SOUTH AFRICAN NATIONAL STANDARD

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

INTERNATIONAL STANDARD

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP

Indianapolis Power & Light Company

UTILITY CROSSING DETAIL

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

SUGGESTED SPECIFICATIONS

For Conduit Inspections

Underground Distribution Switchgear

SECTION VII METERING INSTALLATIONS

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

St. Johns River State College BID-SJR Addendum Three ADDENDUM THREE DATED JUNE 13, 2016

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

DURALITE. Surprisingly Light. Exceptionally Strong. DURALITE Surprisingly Light. Exceptionally Strong.

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Purchasing Services 4202 East Fowler Avenue, SVC 1073 Tampa, Florida (813) Addendum No. 1

Technical Specifications

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

31-SDMS-01 REV. 03 SPECIFICATIONS FOR

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Approved Meter Sockets and Cabinets

34-SDMS-02 SPECIFICATIONS FOR

Meter Installation. -and- Padmount Transformer Guide

The cost estimation methodology used to update the charges and credits is the same methodology the Company utilized in the prior year s filing.

A. Submit manufacturer's literature and technical data before starting work.

PARKING LOT REHABILITATION PROJECT FOR: SJRSC PALATKA CAMPUS

City of Ottawa Street Lighting. HID Shoebox Style Luminaire

TOPAS 2130A (Draft v3)

D. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:

7 Single Family Service

PERMANENT RESIDENTIAL UNDERGROUND SERVICE

RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS SECTION II RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS

RPS Station. Solutions for the North American Solar Market

Support and management of this policy. Ensure policy is adhered to by all employees. Follow requirements contained in this policy.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.


Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

ADDENDUM #2 TO BID # BID NUMBER: ISSUE DATE: Friday, January 18, 2019

Electric Vehicle Charging Station

Table of Contents. Electrical Service Requirements. 1. General Requirements

Associated equipment As related to metering equipment: such as the current transformers, CT wiring and test switches.

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION WATER DISTRIBUTION VALVES

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

University of Houston Master Construction Specifications Insert Project Name

12-SDMS-02 REV. 05 ( )

INSTRUCTION MANUAL L WIND CONE

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications

SOUTH AFRICAN NATIONAL STANDARD

Alliant Energy - Gas Service Manual Chapter 4 Gas Meter Connections

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

SOUTH AFRICAN NATIONAL STANDARD

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

TV Lift System Model L-75i Installation Instructions

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

OBE-3 Outdoor Series

Commercial Electric Policy

Transcription:

E n g in e e r :R.An th o n Ap p r o v e r :Jo s h u a Jo n e s 2 0 De c 1 7 2 0 De c 1 7 ZG 521 Padvault Three-Phase Transformer ZG 521 Padvault Three-Phase Transformer 1. Scope This material specification outlines the minimum requirements for padvaults to be used in conjunction with company-owned, three-phase, pad-mounted transformers (see Figure 1). The material specification applies whether the padvault is to be installed by company personnel, contractor, customer, or the supplier. 2. Applicable Documents The latest revisions of the documents, standards, codes, and requirements listed in 2.1, Company s, and 2.2, Codes and Standards, in effect on the date of invitation to bid apply to the extent specified herein. 2.1. Company s ZG 301, General Equipment Base and Enclosure Requirements ZG 311, Concrete Requirements ZG 621, Padvault 5' 7' (56 84 ), for Three-Phase Sectionalizing Cabinets and Metering Equipment ZG 641, Padvault Shallow, 7' 7' (84 84 )P ZG 811, Full Traffic Cover and Frame Assembly 2.2. Codes and Standards ASTM C 857 A-16 AASHTO H-20 (for vault, beneath roadways) ASTM C 857 A-8 (for vault, beneath incidental light truck traffic) 3. Definition Company refers to PacifiCorp. PacifiCorp refers to Pacific Power and Rocky Mountain Power. 4. General This material specification states material and construction requirements that are applicable to all three-phase transformer pads. 5. Applicable Stock Item Numbers Materials being submitted for the following company stock item numbers are subject to evaluation in accordance with requirements in this material specification. 7992600: Includes a 56ʺ x 84ʺ x 48ʺ padvault plus an 84ʺ x 112ʺ padvault pad for 2.4-25 kv, 75-750 kva transformers Page 1 of 8

7992958: Includes an 84ʺ x 84ʺ x 54ʺ padvault plus a 84ʺ x 112ʺ padvault pad for 2.4-25 kv, 1000-2500 transformers 7992602: Includes a 56ʺ x 84ʺ x 48ʺ padvault plus an 96ʺ x 112ʺ padvault pad for 35 kv, 75-7500 kva transformers 7992959: Includes an 84ʺ x 84ʺ x 54ʺ padvault plus a 96ʺ x 112ʺ padvault pad for 35 kv, 1000-2500 transformers 6. Design and Manufacturing Requirements The purpose of a three-phase transformer padvault is to support a three-phase transformer. 6.1. Padvault Layout The three-phase transformer padvault is a combination of a padvault and a padvault pad (lid). Unless otherwise approved by the company, all dimensions and placement of hardware shall conform to those shown in Figure 1 and Figure 3 of this document. The three-phase transformer padvaults use two common bases. The first base is a 56ʺ x 84ʺ x 48ʺ padvault. The second base is an 84ʺ x 84ʺ x 54ʺ padvault. Also, each padvault will use two different pads (lids) to offer adequate space for multiple sizes of transformers and associated voltages. 6.2. Mounting and Mounting Hardware The supplier shall provide: two 2ʺ x 4ʺ x 24ʺ composite boards for a three-phase transformer, cast flush with the top of the padvault lid, at the locations specified in Figure 1 and Figure 3. two 1-¼ʺ x 2-½ʺ stainless steel hold-down cleats with ¼ʺ lift and 9 / 16ʺ x 1-½ʺ holes. All loose hardware shall be packaged, and the package shall be attached to one of the padvault walls. Page 2 of 8

Figure 1 Padvault for 2.4-25 kv Three-Phase 75-750 kva Transformer (SI#7992600) Page 3 of 8

Figure 2 Padvault for 35 kv Three-Phase 75-750 kva Transformer (SI#7992602) Page 4 of 8

Figure 3 Padvault for 2.4-25 kv Three-Phase 1000-2500 kva Transformer (SI#7992958) Page 5 of 8

Figure 4 Padvault for 35 kv Three-Phase 1000-2500 kva Transformer Padvault (SI# 7992959) Page 6 of 8

6.3. Pulling Attachments Refer to ZG 621 and ZG 641 for pulling attachment specifications. Pulling attachments shall be rated for 6000 lbs of pulling tension. 6.4. Conduit Entrances Refer to ZG 621 and ZG 641 for locations of conduit entrances. 6.5. Lifting Attachments Enough lifting attachments shall be provided to ensure safe installation of all pieces at the site. 6.6. Access Panels All three-phase transformer pads that rest on an padvault shall have a single access door no larger than 24ʺ x 60ʺ. The access door must meet all requirements in specification ZG 811. 6.7. Installation This unit shall be installed at the site by the supplier or contractor. There shall be a 6ʺ base of ¾ʺ-minus gravel under any part of the pad that hangs off the padvault. The 6ʺ gravel base shall be compacted to 90% dry density, and shall be level to the top of the padvault. The joint between the pad and padvault shall be sealed using tar or mastic. The top of the pad should be two to four inches above final grade, when installed. 7. Testing 7.1. Test Compliance Padvaults submitted under this material specification shall meet all tests and requirements contained in ZG 301, General Equipment Base and Enclosure Requirements, ZG 311, Concrete Requirements, and this material specification. Padvaults shall also comply with requirements in applicable national standards. 7.2. Security Test Transformer padvaults must be designed and tested to ensure that padmount equipment is not compromised by uneven pad setting. And, with the appropriate transformer mounted, attempt to pass a #14 AWG soft-drawn copper wire through the interface between the cabinet and pad. If the wire can be passed through, the padvault has failed the test and is not acceptable. 8. Issuing Department The engineering standards and technical services department of PacifiCorp published this material specification. This material specification shall be used and duplicated only in support of company projects. Page 7 of 8

This page is left blank intentionally. Page 8 of 8