Installation Instructions for Eaton Surge Protective

Similar documents
BSPA Type 1 and Type 2 surge protective devices

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

MaxLite LED UTILITY WRAP FIXTURES

Motorized Stainless 2-Way Valves

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

INSTALLATION & OWNER'S MANUAL

Installation Power Management Unit Battery Cables and Battery Harness

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

The Da-Lite Difference.

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

BMRX Series ROTARY LEVEL CONTROL

Quik-Spec Coordination Panelboard Specifications

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Installation Manual & Warranty

LED LARGE WALL PACK (CUTOFF & STANDARD)

Air Curtain. Installation, Operating and Maintenance Instructions

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

The easiest and fastest way to select and specify the right control circuit fuse

O & M Manual for the EATON Generator Ready Loadcenter

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Installation Instructions

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

3-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Patient Care Facility

SPC-PANEL Simplex, Single Phase Pump Control Panel

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

BP1204 INSTALLATION/OWNER'S MANUAL

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

5-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors

The Da-Lite Difference.

MIL-24/2600Q MIL-24/3200DQ

The Da-Lite Difference.

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Pump Installation and Service Manual HRS Hydromatic Retractable System

Filtered PWM Speed Control for Permanent Magnet DC Motors

MaxLite LED Linear HighBay Fixtures

Instruction Manual. Fudge Puppy Display Case

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

Instruction Book for. ContouR ElECtRol

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

INSTALLATION/OWNERS MANUAL

READ AND SAVE THESE INSTRUCTIONS FOR THE DUCTSTAT TEMPERATURE SENSITIVE SWITCH

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

DC Distribution Panel User Guide # S

Grundfos MAGNA, Relay Module

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS BULLETIN MODEL DA750 March MAGNETIC INSPECTION UNIT

TC26-B Vehicle Sensor

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

Operators Manual ECO-AIR-IVS Internal Valve Actuation System

HA/HAB Fiberglass Wall Mount Ventilators

AUTO CHARGE D PUMP PLUS

OWNERS MANUAL JANUARY 2007 ISO

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

A2P Single Phase Automatic Industrial Battery Charger

Installation Instructions

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

CTFRP Series Power Supplies

DC to AC Power Inverters

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

ADI-125/750 ADI-125/1500 ADI-125/2500

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Model C230 Pump Controller

Non-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.

HBC-20 - LED HIGH BAY

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Kitchen Tech Series Air Curtain

Transcription:

Contents Description Page PH Model Introduction.... 2 Safety Precautions.... 2 Operation.... 2 Preparation... 2 Installation Procedures... 3 Enclosure Mounting (New Applications - Eaton PH and PV Models).... 3 Enclosure Mounting (Existing Aegis HW applications).... 3 Wiring Instructions Eaton PH Model.... 3 Enclosure Mounting (Existing Aegis VL applications).... 5 Wiring Instructions Eaton PV Model.... 5 Specifications... 7 Diagnostics.... 7 Maintenance.... 7 Terms and Conditions.... 7 Warranty... 8 PV Model

Introduction Eaton s PH and PV products are premium Surge Protective Devices (SPDs) with filtering. They are applied to protect sensitive electronic equipment (critical loads) from transients and electrical line noise. Correct installation is critical for the proper operation of the Eaton PH and PV devices. Please read the entire installation and operating instructions prior to installing the Eaton PH or PV devices. Safety Precautions IMPROPER INSTALLATION COULD CAUSE DEATH, INJURY AND EQUIPMENT DAMAGE. FOLLOW ALL WARNINGS AND CAUTIONS. COMPLETELY READ AND UNDERSTAND THE INFORMATION IN THIS MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THIS EQUIPMENT. IMPROPER WIRING COULD CAUSE DEATH, INJURY AND/OR EQUIPMENT DAMAGE. ONLY LICENSED/QUALIFIED ELECTRICIANS WHO ARE TRAINED IN THE INSTALLATION AND SERVICE OF ELECTRICAL SERVICES ARE TO INSTALL AND SERVICE THIS EQUIPMENT. HAZARDOUS VOLTAGES ARE PRESENT INSIDE THE SPD DURING NORMAL OPERATION. FOLLOW ALL SAFE PRACTICES TO AVOID ELECTRICAL SHOCK. Operation Properly installed, Eaton s PH and PV devics will protect electronic equipment from surges and electrical line noise. They are installed in series with the load to be protected. Under normal conditions, the Eaton PH and PV devices will only draw a small capacitive current from the line. When electrical surges or line noise exists, the Eaton PH and PV devices will remove that portion of the disturbance. Preparation Before installation, verify that the amperage and voltage ratings of the Eaton PH or PV device matches the application. The maximum amperage rating of Eaton s PH and PV devices are identified on the nameplate located on the side of the enclosure. The maximum amperage of the critical load must be equal to or less than Eaton s PH or PV device being installed. If the amperage rating is exceeded, the unit can overheat and fail. To verify the voltage rating, check the nameplate on the side of the enclosure. The maximum voltage will be the same from Line to Neutral (L - N), Line to Ground (L - G), and Neutral to Ground (N - G). This makes the Eaton PH and PV devices suitable for bonded systems that are L, N, G as shown in Figures 1 and 3 or for Unbonded systems that utilize L, L, G as shown in Figures 2 and 4. The amperage and voltage rating is also indicated in the catalog number. The catalog number can also be found on the nameplate. Review the application to ensure physical space exists for the product installation. Review and check the grounding system. All grounding and bonding systems must meet NEC, CEC and/or applicable local codes. A poor ground or grounding and bonding violations will seriously affect the ability of Eaton s PH and PV to function as specified. The Eaton PH and PV input ground and output ground are internally wired together. Loads that require a separate ground must use the output ground from the Eaton PH and PV. Loads that are grounded to the chassis of the equipment do not require the output ground from the Eaton PH and PV to prevent ground loops. The Eaton PH and PV input ground should be connected to the local ground point in all installations. Overcurrent protection is required to protect the distribution system from an unlikely failure of the Eaton PH and PV or downstream load. Overcurrent protection must be sized according to the downstream load with an additional 1, 1.5, or 2.5 ampere margin for the Eaton PH and PV capacitive current draw as shown in Table 1. Table 1. Capacitive Current Voltage Frequency Capacitive Current 120V 50 to 60 Hz 1 amp 120V 400 Hz 2.5 amp 220V 50 to 60 Hz 1.5 amp This ampere margin is especially important for loads under five (5) amperes. The ampere current draw of the Eaton PH and PV device is capacitive and may increase if there is significant noise on the power line. This will not detract from the output current rating of the Eaton PH and PV as the current rating of the Eaton PH and PV is based on the output current only. An external circuit breaker in series with the load is required for a permanently connected two-port SPD and shall be suitably rated for branch-circuit protection in accordance with the National Electrical Code, ANSI/NFPA-70 and Canadian Electrical Code (CEC). See Table 2. Circuit Breaker Recommendations. Table 2. Circuit Breaker Recommendations Filter Model xxpvxxxxx xxphxxxxx Recommended Circuit Breaker Eaton P/N: WMZT1C07 or equiv. 7 amp circuit breaker Eaton P/N: WMZT1C25 or equiv. 25 amp circuit breaker 2

Instruction Manual IM01005022E Installation INSTALLING AN SPD THAT IS IMPROPERLY RATED FOR THE ELECTRICAL SYSTEM VOLTAGE COULD CREATE A POTENTIALLY HAZARDOUS CONDITION, RESULTING IN INJURY OR EQUIPMENT DAMAGE. CAUTION EATON SPD PRODUCTS MUST BE INSTALLED OR REPLACED BY A QUALIFIED ELECTRICIAN TO AVOID INJURY OR EQUIPMENT DAMAGE. TURN OFF THE POWER SUPPLY BEFORE WORKING IN ANY ELECTRICAL CABINET OR ON ANY CIRCUIT BREAKER PANEL. FAILURE TO DO SO COULD RESULT IN INJURY OR DEATH FROM ELECTRICAL SHOCK. NOTICE A POOR GROUND, OR GROUNDING/BONDING VIOLATIONS, COULD PREVENT THE SPD FROM PERFORMING AS SPECIFIED. For optimal protection, place the Eaton PH and PV as close as possible to the load being protected. Eaton recommends that the wiring from the Eaton PH and PV output terminals to the input terminals of the electronic equipment be kept as short and straight as possible. This will prevent the wiring from acting as an antenna that picks up high frequency noise from the environment. Wiring length to the input terminals of the Eaton PH and PV is not critical. To prevent the risk of electrical shock, TURN OFF and Lock Out all power sources to the electrical circuit where the Eaton PH or PV is to be installed. Verify that the power has been disconnected with a portable voltmeter or other measuring device. Enclosure Mounting (Existing Aegis HW applications) Aegis HW devices were mounted either with the use of a DIN Rail or by the enclosure s base feet with two screws. If the device was mounted using the enclosure s base feet, uninstall the Aegis HW and dispose of the old hardware. If the Aegis HW was mounted using the DIN Rail feature, place a screwdriver in the slot on the DIN Clip (Output side at bottom of enclosure), pulling the DIN Clip out to release the enclosure from the DIN Rail. If the previous device was DIN Rail mounted you can reuse the existing DIN Rail to mount the new Eaton PH device. Engage the Eaton PH base (Output side, enclosure bottom) of the DIN Clip to the DIN Rail and compress DIN clip spring by pushing the enclosure towards the Input terminal side of the enclosure until the opposite side of the DIN Clip hook engages. Then slowly release the spring pressure securing the Eaton PH enclosure to the DIN Rail. Wiring Instructions Eaton PH Device - Install an overcurrent protection device on the input side of the Eaton PH device. Wire from the overcurrent protection device to the input terminal(s) of the Eaton PH device. The terminals are marked L, N, and G. Wire gauge should be selected to match the amperage of the overcurrent protection device. Ensure that the proper color wire is used (green or green/yellow ground, white or light blue neutral, black and/ or red phase). Tighten all input and output terminal connections to 9 lb-in. Wire from the Eaton PH output terminals to the input terminals of the protected load. Tighten all input and output terminal connections to 9 lb-in. Install terminal block covers by pressing into place on both the input and output terminals. If the Form C contact is used for remote monitoring there will be one N.O. and one N.C. contact. The terminal connections are labeled on the top of the enclosure. To activate, connect the Form C output terminals to an alarm, light or building monitoring system. Tighten all Form C terminal connections to 4 lb-in. The relay is rated for a maximum of 250V and 8 amperes. Recheck all connections. Restore power to the electrical circuit. Check that the status indicator (green LED) is illuminated. If using the Form C relay contact, check to see that it is operating as desired. Enclosure Mounting (New applications) Every Eaton PH and PV device includes a DIN Rail and two mounting screws (#8 Sheet metal screw) to mount the device. Drill appropriate hole sizes, based on material and thickness, at desired spacing using the DIN Rail slots as a template. After the DIN Rail has been secured, engage the Eaton PH or PV base (Output side, enclosure bottom) of the DIN Clip onto the DIN Rail and compress DIN clip spring by pushing the enclosure towards the Input terminal side of the enclosure bottom until the opposite side of the DIN Clip hook engages the DIN Rail. Then slowly release the spring pressure of the DIN clip securing the Eaton PH or PV enclosure to the DIN Rail. Proceed to the appropriate Wiring Instructions. Figure 1. PH Model Dimensions. 3

Figure 2. Eaton PH Premium Hybrid Filter Bonded System Block Diagram. Figure 3. Eaton PH Premium Hybrid Filter Unbonded System Block Diagram. 4

Instruction Manual IM01005022E Enclosure Mounting (Existing Aegis VL applications) CAUTION THE INPUT AND OUTPUT TERMINAL LOCATIONS ARE NOT POSITIONED ON THE SAME SIDE OF THE ENCLOSURE TOP COVER AS THE FORMER AEGIS VL MODELS. ROUTE WIRING TO ACCOMMODATE THE NEW INPUT AND OUTPUT TERMINAL LOCATIONS. Aegis VL devices mounted to a DIN Rail using the attached DIN clip. Remove the existing device from the DIN Rail by placing a screw driver in slot on the DIN Clip (Output side at base), pulling the DIN Clip out to release the enclosure from the DIN Rail. Now install the Eaton PV device using the attached DIN clip mounted on the bottom of the enclosure. Engage the Eaton PV base (Output side, enclosure bottom) of the DIN Clip to the DIN Rail and compress DIN clip spring by pushing the enclosure towards the Input terminal side of the enclosure until the opposite side of the DIN Clip hook engages. Then slowly release the spring pressure securing the Eaton PV enclosure to the DIN Rail. Wiring Instructions Eaton PV - Install an overcurrent protection device on the input side of the Eaton PV. Wire the overcurrent protection device to the input terminal(s) of the Eaton PV. The terminals are marked L, N, and G. Wire gauge should be selected to match the amperage of the overcurrent protection device. Ensure that the proper color wire is used (green or green/yellow ground, white or light blue neutral, black and/or red phase). Wire from the Eaton PV output terminals to the input terminals of the protected load. Tighten all input and output terminal connections to 9 lb-in. Install terminal block covers by pressing into place on both the input and output terminals. Recheck all connections. Restore power to the electrical circuit. Check that the status indicator (Green LED) is illuminated. Figure 4. PV Model Dimensions.. 5

Figure 5. Eaton PV Premium Filter Bonded System Block Diagram. Figure 6. Eaton PV Premium Filter Unbonded System Block Diagram. 6

Instruction Manual IM01005022E Specifications Table 3. Specifications Application Eaton PH 2W +G Grounded Systems Eaton PV 2W +G Grounded Systems Input Voltage 120V, 220V, 240Vac single-phase 120V, 220V, 240Vac single-phase Amperage 3, 5, 10, 15, & 20 amperes 1, 3, 5 amperes Frequency 50/60 Hz 50/60 Hz Protection Modes L-N, L-G, & N-G L-N, L-G, & N-G MCOV 150V & 275V 150V & 275V Noise Attenuation (Normal Mode) 75dB @ 110 KHz 50dB @ 100 KHz Filter Bandwidth 10 khz to 100 MHz 10 khz to 100 MHz Total Peak Surge Current 30kA per mode 20kA per mode Operating Temperature -40 F to +122 F (-40 C to +50 C) -40 F to +122 F (-40 C to +50 C) Response Time Less than one nanosecond Less than one nanosecond Agency Approvals UL 1449 3 rd Edition, UL 1283 5 th Edition, CSA UL 1449 3 rd Edition, UL 1283 5 th Edition, CSA Warranty 10 years standard / 5 additional years if registered on-line ** 10 years standard / 5 additional years if registered on-line** Form C Contacts Yes No External Circuit Breaker* Eaton P/N: WMZT1C25 or equiv. 25 amp circuit breaker Eaton P/N: WMZT1C07 or equiv. 7 amp circuit breaker RoHS Compliant Yes Yes *External circuit breaker sold separately. **Register products on-line at www.eaton.com/spd. Then click on Warranty Registration. Diagnostics The Eaton PH and PV are supplied with a green LED that will illuminate and indicate power at the output terminals. If the green LED is not illuminated, it indicates that power is not being supplied to the device. The LED will not illuminate if there has been a utility power failure, or an internal failure of the suppression components. If the internal suppression components fail, a short circuit will result. The short circuit will open the overcurrent device on the power supply, removing power to the device. Whenever power is removed from an Eaton PH or PV device the green LED will not illuminate and the optional monitoring relay (Form C contact), if installed, will change state. Maintenance Preventive Maintenance (Inspection and Cleaning) Periodic system inspections, cleaning, and connection checks are recommended to ensure reliable system performance. There is no defined schedule for preventive maintenance, as conditions will vary from installation to installation. Corrective Maintenance (Repair or Replacement) the Eaton PH and PV are designed to provide years of continuous service. However, even the most reliable equipment may fail. In the unlikely case that the LED monitor or remote monitoring (Form C contact) indicates a failure, check the overcurrent protection on the power supply. Replace or reset the overcurrent protection. If a problem still exists, contact Eaton s Surge Protection application support at: 1-800-809-2772, option 4, option 2. Terms and Conditions of Sale The Terms and Conditions of Sale are listed in the Eaton Selling Policy, Publication No. SP03000001E. 7

Warranty Eaton warrants these products for a period of 10 years from the date of delivery to the purchaser, 15 years if the product is properly registered with Eaton, to be free from defects in both workmanship and materials. Eaton assumes no risk or liability for results of the use of the products purchased from it, including but without limiting the generality of the foregoing: (1) The use in combination with any electrical or electronic components, circuits, systems, assemblies, or any other materials or substances; (2) Unsuitability of any product for use in any circuit or assembly. Register products on-line at www.eaton.com/spd. After the page opens click on the Warranty Registration link in the right hand column. Purchaser s rights under the warranty shall consist solely of requiring Eaton to repair, or at Eaton s sole discretion, replace, free of charge, F.O.B. factory, and defective items received at said factory within said term determined by Eaton to be defective. The giving of or failure to give any advice or recommendations by Eaton shall not constitute any warranty by or impose any liability upon Eaton. The foregoing constitutes the sole and exclusive liability of Eaton AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED OR STATUTORY AS TO THE MERCHANTABILITY, FITNESS FOR PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS OR ANY OTHER MATTER. In no event shall Eaton be liable for special or consequential damages or for delay in performance of the warranty. This warranty does not apply if the product has been misused, abused, altered, tampered with, or used in applications other than specified on the nameplate. At the end of the warranty period, Eaton shall be under no further warranty obligation expressed or implied. The product covered by this warranty certificate can only be repaired or replaced by the factory. For help on troubleshooting the SPD, or for warranty information, call 1-800-809-2772, Option 4, sub-option 2. Repair or replacement units will be returned collect. If Eaton finds the return to be a manufacturer s defect, the product will be returned prepaid. Eaton Electrical Sector 1000 Eaton Boulevard Cleveland, OH 44122 United States 877-ETN-CARE (877-386-2273) Eaton.com 2013 Eaton All Rights Reserved Printed in USA Publication No. IM01005022E / TBG001101 September 2013 Eaton is a registered trademark. All other trademarks are property of their respective owners.