CONCRETE CONTROLS CORPORATION 1311 N. CONGRESS DRIVE CHANDLER AZ FAX

Similar documents
150 PSI ILLUMINATED DASH PANEL GAUGE KIT

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

UNIMIX EM. Operations Manual. Supplied by:

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

From the industry leader in concrete batch plants and mixers... Rugged Reliability Superior Performance. PRINTED IN U.S.A.

BRAKE SYSTEM, HYDRAULICALLY ACTUATED - 631G TRACTOR Cat Tractors with standard shoe/drum brakes

HP10098 BASIC INDEPENDENT AIR SPRING ACTIVATION KIT

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS

ONBOARD AIR HOOKUP KIT

11202 INSTALLATION INSTRUCTIONS

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

MODEL: ATV Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

The Mark V Air/Fuel Controller - Technical Manual -

INSTALLATION MANUAL - v4

30,000 lb. HEAVY DUTY PPF 195 POST PULLER

HP FUEL PUMPS P/N & Installation Instructions 199R10569

ONBOARD AIR SYSTEM FOR ALL VEHICLES APPLICATIONS

OWNER S MANUAL REMOTE CONTROL, DUAL HEAD FOGGING SYSTEMS

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Installation & Operating Manual

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

Constant Speed Control

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

HP FUEL PUMPS P/N ERL & ERL Installation Instructions 199R11108

HP10134 & HP10135 KITS BASIC SIMULTANEOUS AIR SPRING ACTIVATION KIT

UNISTEER Performance Products UNIVERSAL HOT ROD ELECTRA-STEER KIT

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

1200 Southeast Ave Tallmadge, Ohio to 2014 Mustang (V6 & V8) Summit Racing Roll Stop Install Instructions.

New & Improved VariFlo Plural Component Equipment. Low Pressure Polymer Dispensing Equipment

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

WORKHORSE. Assembly / Operation Instructions / Parts

PROPER ELECTRICAL CONNECTIONS

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Reference Manual /12

TIPSTER ELECTRICAL/HYDRAULIC INSTALLATION GUIDELINES 2DAK HOIST

Installation Instructions

Parts & Service Information K810054C PRODUCT IMPROVEMENT

APOLLO Gate Operators, Inc.

Installation Notes for Ford Excursion 7.3L

Putty 2000 Chop Check Start-Up Instructions

DOMINATOR FUEL PUMPS P/N & Installation Instructions 199R10573

77 Ton Tele-Boom Crawler Crane. mantiscranes.com

INSTRUCTION, TRAIL CHARGER KIT P/N

DIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Air Spray Proportioning Valve

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

REAR MOUNT AERIAL LADDER USED AS A WATER TOWER

To ensure proper installation, digital pictures with contact information to before startup.

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

Overview. Selection of System Components VT BBK/CWH. Chart LNG Vehicle Tank and Fuel System Installation Guidelines

Hose Reel Kit for Multi-Pro 1200 and 1250 Sprayers. Installation Instructions. Form No Model No Serial No.

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

Owner's Manual. Model: ATVBK-3025 ( ) (Boomless Nozzle Kit for ATV Mounting) Technical Specifications. Assembly. General Information

CRUISE CONTROL SYSTEM

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

Dodge Cummins Positive Air Shutoff

WORKHORSE. Assembly / Operation Instructions / Parts

OPERATION AND PARTS MANUAL

Pump Operating and Maintenance Manual - Models

DIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500

Installation & Operating Manual

Hose Reel Kit for Workman 200 Spray Systems. Installation Instructions. Form No Rev A. Model No Serial No.

10,000 lb. REGULAR DUTY PPF 203 POST PULLER

CORPORATION REPAIR MANUAL HWH TOUCH PANEL-CONTROLLED LEVELING SYSTEM 310 SERIES FEATURING:

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

RAIN BIRD - AQUAGATOR AQUAGATOR INSTALLATION & TROUBLESHOOTING MANUAL

radial GATES Waterman Industries of Egypt

Fuller Automated Transmissions TRDR0082

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

C40008 & C40009 EXHAUST BRAKES

Owner's Manual. Model: UTL-60-7-TSC ( ) (60 Gallon Utility Sprayer w/ 7-Nozzle Boom Assembly) Technical Specifications.

SMC Leveling System. 2001,2002 & 2003 Marquis, Patriot & Contessa

CORPORATION SERVICE MANUAL HWH TOUCH PANEL-CONTROLLED 310 SERIES LEVELING SYSTEM FEATURING:

Assembly / Operation Instructions / Parts

WESTINGHOUSE / CUTLER HAMMER DS POWER BREAKERS

HEAVY DUTY ONBOARD AIR SYSTEM

MODEL NO. ATVBK NOZZLE BOOM ASSEMBLY FOR ATV MOUNTING ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

SECTION B: SYSTEM OPERATING COMPONENTS

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

Kits 25415, INSTALLATION GUIDE. Magnetic Height Sensor

Model &

TELESCOPIC BOOM CRAWLER CRANE 45 TON CAPACITY

Dodge Cummins Positive Air Shutoff

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

WORKHORSE. Assembly / Operation Instructions / Parts

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

F76 Water Filters. Specifications. and MV876 Automatic-Backwash Control Accessory (not included)

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

Index. 1. Important safety instructions Overview of the lift Installation instructions Operation instructions 8-9

Tools Needed for Mounting Cleá Filling Station

Items # and #

Removal and Installation of Fuel Injection Pumps

Transcription:

CONCRETE CONTROLS CORPORATION 1311 N. CONGRESS DRIVE CHANDLER AZ 85226 1-800-345-6654 FAX 1-480-821-1138 INSTALLATION INSTRUCTIONS FOR DIAL-A-MATIC & SEMI-MATIC HYDRA-SLUMP TECHNICAL INFORMATION SHEET, DHS-94 A. INSTALL 1. PARTS: Check to see that all these parts are present: control unit, solenoid valve, needle valve, flow control, two hydraulic hose fittings, control unit cable, and in-line fuse holder. 2. LOCATION: Select a location in the cab that will provide easy view and reach for the driver. Take great care not to obstruct drivers vision. 3. MOUNTING: Fabricate a metal bracket (see Figure 1 and template A ) and mount control unit. For easy opening dashboards, two large sheet metal screws will suspend unit under dash easily. Also mount needle valve to the back of the control unit now. 4. PLUMBING: The solenoid and flow control are installed to bypass the manual water add valve. (See Fig. #2). The solenoid should be mounted horizontally to facilitate drainage. Note direction of flow stamped on valve body. Install the flow control up stream of the valve. Note flow direction stamped on the flow control. A hand valve to shut off the bypass system is recommended. Finally, a piece of rubber or plastic hose placed somewhere in the circuit is recommended to relieve any strain. 5. HYDRAULIC: Using the O ring fitting supplied, connect a hydraulic hose of appropriate burst strength to the test port of the hydraulic motor which is pressurized in the mix direction. To determine which test port to use; loosen each test port plug, engage drum in mix direction taking note of which port leaks. Save the test port plug in case of hose failure. Find or make as appropriate opening in the cab wall or floor, taking care to route the hose away from extreme sources of heat and abrasion, and pass the hose into the cab. With the remaining hydraulic fitting, connect the hose to the needle valve making sure that the needle valve is fully closed. 6. ELECTRICAL: Using a customer supplied two wire cable, extend the solenoid wires to the yellow control unit cable as shown in Fig. #3. Connect the white control cable wire to a +12 volt source. Note: IN POSITIVE GROUND VEHICLES, THE HOT WIRE IS NOT THE +12 VOLT SOURCE. Also Note: THE IN-LINE FUSE MUST BE INSTALLED IN THIS LINE. connect the green wire to any -12 volt source and either of the solenoid wires. The other solenoid wire must be connected to the black control wire.

CHECK - 1. CONTROL UNIT NEEDLE VALVE IN PLACE AND COMPLETELY OFF. 2. SOLENOID VALVE AND FLOW CONTROL DIRECTION OF FLOW PROPER. 3. ALL HYDRAULIC FITTINGS TIGHT. 4. FUSE IN-LINE HOLDER, 3-5 AMPS. TEST - 1. Turn Power to unit ON. 2. Water tank not pressurized. 3. Station one man at solenoid valve. 4. Turn timer to at least 3 minutes. 5. Turn function switch to MANUAL. (ON on SHS model) 6. NOTE if light activates and the solenoid actuates. 7. Turn function switch to OFF. 8. Start engine and engage drum in mix direction. 9. Open needle valve JUST ENOUGH for a 100 psi/sec. rise. Steps 10-13 for DHS MODELS ONLY 10. Turn timer to at least three minutes. 11. Turn function switch to AUTO. 12. Turn set hand to a reading lower than black hand. 13. Note if light activates and the solenoid actuates. 14. Turn function switch to OFF. 15. Pressurize water system and check for leaks.

SERVICE INFORMATION Pack your meters CAREFULLY, protecting faces, enclose a note as to the malfunction and ship by UNITED PARCEL SERVICE to: SOUTHWEST SLUMPMETER SERVICE 2017 W. SILVERGATE DRIVE CHANDLER, AZ. 85224 1-480-820-1314 SERVICE BULLETIN - #DHS-1 E F F E C T I V E I M M E D I A T E L Y TO: SERVICE MANAGER RE: NEEDLE VALVE SETTINGS THIS SERVICE BULLETIN IS NECESSARY DUE TO THE NUMBER OF INDICATOR FAILURES ON THE CONCRETE CONTROLS CORPORATION HYDRAULIC DIAL-A-MATIC ELECTRIC TRUCK TEL-A-SLUMP OR THE DIAL-A-MATIC HYDRA SLUMP. IT HAS BEEN OUR EXPERIENCE THAT HYDRAULIC GAUGE NEEDLE FAILURES ARE DUE TO IMPROPER NEEDLE VALVE SETTINGS. THE PURPOSE OF THE NEEDLE VALVE IS TO REMOVE ALL RAPID HYDRAULIC OSCILLA- TIONS. THE FOLLOWING PROCEDURE SHOULD BE PERFORMED AS SOON AS POSSIBLE TO INSURE A LONG LIFE FOR THE HYDRAULIC GAUGE AND GAUGE INDICATOR NEEDLE. 1. WITH ENGINE OFF, CLOSE NEEDLE VALVE FULLY. 2. START ENGINE AND ENGAGE DRUM IN MIX DIRECTION. 3. OPEN NEEDLE VALVE TO GET A 100 PSI PER SECOND RISE ON GAUGE NEEDLE. 4. HAVE DRIVER OBSERVE INDICATOR NEEDLE DURING MIXING. IF ANY OSCILLA- TIONS ARE OBSERVED, THE NEEDLE VALVE CAN BE FURTHER CLOSED TO REMOVE THE UNWANTED OSCILLATION.

FOR DRIVER LEAVE IN CAB!! Hydra-Slump Instructions: THE MANUAL TIMER MUST NOT BE TURNED ON UNTIL THE HYDRAULIC PRESSURE HAS STOPPED FALLING WHICH INDICATES THE CONCRETE IN THE DRUM IS THOROUGHLY MIXED!! 1. Upon taking charge of materials OBSERVE hydraulic pressure reading. 2. While driving to job, continue to observe hydraulic pressure until pressure stops falling, which indicates that necessary mixing is now complete. 3. Turn MANUAL TIMER SWITCH to enough time for controller to adjust the slump. 4. RED LIGHT ON means water is flowing into mixer. 5. Light will go out when water is off. SLUMP CHART INCHES OF SLUMP HYDRAULIC PRESSURE

To: DRIVERS OF READYMIX TRUCKS WITH THE HYDRA-SLUMP Learning to use this system is a two-step process. The first is calibration, and the second is actually controlling the slump. The calibration step involves learning to translate the hydraulic pressure gauge reading into inches of slump. The gauge tell how much effort is being used to turn the drum. The drier the load, the more effort is needed to turn the drum, and the higher the gauge reading will be. Since you see hundreds of loads every year, you will quickly see the relationship between the slump and the hydraulic pressure reading. Here are some guidelines to follow as you learn the relationship between a specific slump and a hydraulic pressure. 1) Observe the gauge after the load is completely mixed. When the gauge reading stops falling and holds steady, the load is completely mixed. 2) After the load is mixed, observe the gauge on the way to the job with the drum speed set about 5 RPM and your road speed about 30 MPH. 3) If your company requires your load to be thoroughly mixed before you leave the yard, observe the gauge with the engine and drum speeds the same each load. 4) If your gauge needle vibrates excessively, close the needle valve on the back of the instrument until the gauge reading is smooth. 5) Load size is not significant. See the note at the bottom of the page for an explanation. One can still get good readings without uniform engine and drum RPM s, but the more uniform these factors are the more accurate the results of your observations. Quality control engineers will most likely want uniformity in these factors if they are assisting you in the calibration process. If you are making slump cone tests do not take your sample from the first discharge revolution. After observing the pressure readings on several different loads of different slumps begin to pencil in your readings on the slump chart. If slump tests are made check your figures and make any adjustments. You might also work with your batchman to hold back water so you can observe a wider range of pressure readings. You will quickly become familiar with the system and be able to produce the slump desired by the customer and your supervisor LOAD SIZE IS NOT A MAJOR FACTOR Load size makes surprisingly less difference in the power requirement than most people think it should be. Several factors contribute to this seemingly paradoxical situation. Power requirements are mostly proportional to lifting action. With a full drum lifting action is minimal. Lifting action, or room to lift, goes up as the size of the load goes down. Simultaneously, the center of gravity of the load moves away from the center of the drum. As the load size goes down the length of the lever arm is increased so that when one yard of concrete is in the drum the distance between the axis of the drum and the center of gravity of that load may be three feet or more while the center of gravity of 7 yards of concrete may be only a few inches away from the axis.

FIG. #1 WELD 3/4" COUPLING & DRILL OUT WITH 1/2 " BIT SOLENOID FIG. #2 10 GPM FLOW CONTROL WASH HOSE CONNECTION IN-LINE FUSE WHITE WIRE CONTROL UNIT 12 VDC SOURCE GREEN WIRE BLACK WIRE FIG. #3