INTERPLANT STANDARD - STEEL INDUSTRY

Similar documents
INTER PLANT STANDARDIZATION STEEL INDUSTRY

INTER PLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR AC CABIN FAN. Corresponding IS does not exist IPSS:

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

INTER PLANT STANDARD STEEL INDUSTRY

SPECIFICATION FOR BUTTON HEAD CEASE NIPPLES

INTERPLANT STANDARD STEEL INDUSTRY ACCEPTANCE NORMS FOR CRANE GEAR BOX FOR TWO STAGE HORIZANTAL Corresponding IS does not exist

INTER PLANT STANDARD STEEL INDUSTRY

INTER PLANT STANDARD STEEL INDUSTRY. SPECIFICATION FOR GENERAL PURPOSE SQUIRREL CAGE INDUCTION MOTORS (Fifth Revision) BASED ON IS 325:1996

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

INTER PLANT STANDARD IN STEEL INDUSTRY SPECIFICATION OF HYDRAILIC HOSE ASSEMBLY & END FITTING FOR HYDRAULIC LINES

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

INTERPLANT STANDARD - STEEL INDUSTRY. SPECIFICATION FOR SINGLE, DOUBLE & TRIPLE SHEAVE PULLEY BLOCKS FOR FIBRE ROPE (Second Revision )

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

045 : 2000 CEB STANDARD

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

The galvanic separation of the primary or actuating circuit and the load circuits

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

AF series contactors (9 2650)

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

INTERNATIONAL STANDARD

Utilization of Electric Power Laboratory 3 rd Year G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications

AF series contactors (9 2650)

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

INTERNATIONAL STANDARD

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Pretest Module 29 High Voltage Unit 1

INTERNATIONAL STANDARD

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

34-SDMS-02 SPECIFICATIONS FOR

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

Type SOQ Negative Sequence Time Overcurrent Relay

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

INSTRUCTION MANUAL MODEL CB-7120A CIRCUIT BREAKER

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Electropneumatic Timing Relays Series 7000 Industrial

Auxiliary Relay. Type RXP8n, RXPQ8n

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

COM Overcurrent Relay

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Thermal Overcurrent Circuit Breaker 3120-F...

MAGNETIC MOTOR STARTERS

SPECIFICATION FOR AUTOMATIC PRIMING AND OPERATING SYSTEM FOR CENTRIFUGAL PUMPS.

Typical Specification

General Purpose Relay

Meta Solution. Contactors and Overload relays

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Miniature Circuit Breaker

Control Relays Overview

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

The Contactor. Antonino Daviu, Jose Alfonso Departamento de Ingeniería Eléctrica. Universitat Politècnica de València

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

INTERNATIONAL STANDARD

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Miniature Circuit-Breakers (MCBs)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

INTERNATIONAL STANDARD

34-SDMS-01 SPECIFICATIONS FOR

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

GB/T / IEC :2007

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

33KV INDOOR SWITCHGEAR

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Circuit Protectors CP31F, 32F, 33F

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

General technical data. Ambient conditions

Thermal Overcurrent Circuit Breaker 3120-F...

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

026-2 : 1996 CEB STANDARD

up to 63 A (1 module per pole)

Selection Guide Motor Control Device Solutions

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

IN2 Enclosed Switches and Circuit Breakers

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-magnetic Miniature Circuit Breaker 4230-T...

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

Transcription:

INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION FOR MAGNETIC OVER- CURRENT RELAYS FOR ac AND dc MOTORS PROTECTION UP TO 650 V (FIRST REVISION) CORRESPONDING INDIAN STANDARD DOES NOT EXIST IPSS:1-04-008-11 Formerly: IPSS:1-04-008-84 0. FOREWORD 0.1 This Interplant Standard has been prepared by the Standards Committee on Electrical Components, IPSS 1:4, with the active participation of the representatives of the steel plants and established manufacturers of relays & was adopted in March 2011. 0.2 Interplant Standards for steel industry primarily aim at achieving rationalization and unification of parts and sub-assemblies used in steel plant equipment and accessories, and provide guidance in indenting store or equipment for existing or new installations by individual steel plants. For exercising effective control on inventories, it is advisable to select a fewer of sizes (or types) from among those mentioned in this standard for the purpose of company standards of individual steel plants. It is not desirable to make deviations in technical requirements. 1. SCOPE This Interplant Standard covers performance requirements of magnetic overcurrent relays used for protection of ac and dc motors against excessive currents. 2. TERMINOLOGY For the purpose of this standard, definitions given in IS 1885 (Part 9):1992 `Electrotechnical vocabulary: Part 9 Electrical relays (first revision)', IS 5834 (Part 1):1994 `Specification for electrical timer relays for industrial purposes: Part 1 Pneumatic (first revision)', and IS 5834 (Part 2):1993 `Specification for electrical timber relays for industrial purposes : Part 2 Motorized (first revision)' shall apply. 3. APPLICATION This relay in general should be applied under the following conditions, where as thermal relay will cause nuisance tripping: a) For the protection of continuous duty motors which have been chosen for 15 or more starts per hour. b) For the protection of 40 percent CDF motors which have been chosen for 50 or more starts per hour. Page 1 of 6

4. SERVICE CONDITIONS 4.1 Ambient Temperature- The reference ambient temperature shall be 50 o C. 4.2 Altitude - The altitude shall not exceed 1000m. 4.2.1 For installations higher than 1000m, it is necessary to take into account the reduction of the dielectric strength and the cooling effect of the air. The relay so used shall be designed or used according to an agreement between the supplier and the purchaser. 4.3 Ambient Air - The ambient air may contain fair amount of conductive dust. 4.4 Humidity - Maximum relative humidity shall be 100 percent. However, both maximum ambient temperature and maximum relative humidity may not occur simultaneously. 4.5 The relay shall be suitable for mounting without any enclosure and shall operate satisfactorily in an industrial atmosphere. (For special application, customer has to specify the enclosure required.) 4.6 The relay shall be suitable for service on EOT cranes, transfer cars and such other mobile equipment; and shall be able to withstand vertical impact 2g, and horizontal impact 1g. 5. RATING 5.1 Rated Insulation Voltage - The rated insulation voltage of the relays shall be 650 V. 5.2 Preferred Rated Current Range - The preferred current ranges of the relays shall be as follows: 0.5-1 A, 1-2 A, 4-8 A, 8-15-A, 15-30 A, 30-63 A, 63-100 A, 100-200 A, 200-350 A, 350-500 A, 500-1000 A and 1000-1600 A. 6. CONSTRUCTION 6.1 The relay shall be of direct acting type; with or without oil dashpot time delay arrangements. 6.2 The relay shall be convertible to self resetting and manual resetting type with minor changes of components only. 6.3 The dc relays shall be of single-pole type and ac relays shall be of single - or threepole design. Page 2 of 6

6.4 There shall be a tray underneath the relay assembly in order to collect dashpot oil splashings on heavy duty operation. 6.5 The safety factor in design shall be such that the relay can sustain short circuit stresses for currents as high as 30 ka for five cycles, for rated currents of 100 A and above. (The verification of this requirement shall be done on the basis of calculations, pending development of indigenous test facilities.) 6.6 The operating coils may be of bare conductor or insulated coil design. Coils shall be able to withstand electro-magnetic stresses due to short circuit currents at the time of fault condition. 6.7 There shall be a calibrated scale with a pointer indicating relay setting range according to the nominal rating of the relay. Arrangement shall be made for proper locking and sealing of the relay after it has been given a specific setting. The calibration scale shall refer to the tripping current of the relay. 7. OPERATIONAL CHARACTERISTICS AND ACCURACY 7.1 The input value at which the relay starts functioning, that is, the armature is pulled in (pick-up value) Xp and the input value at which the relay armature drops out (Dropout value) Xd, shall be such that the Resetting Ratio Xd is between 0.8 to 0.9. In case of dashpot relays, the operating Xp time shall be more than 0.25 second. 7.2 The relay shall be able to withstand 600 starting and plugging operations per hour of motors and shall operate within + 5 percent repeat accuracy of calibrated values. 8. CONTACT RATINGS 8.1 For ac Application - The contacts shall be rated for not less than 6 A, 415 V, 50 Hz for a rated duty of ac-11 [see IS 60947-1:2004] 8.2 For dc Application - The contacts shall be rated for not less than 1 A, 230 V for a rated duty of dc-11[see IS 60947-1:2004] 8.3 The preferred rated thermal current shall be 10 A. 9. DASHPOT OIL The oil shall be of such characteristics that the relay operation is stable between 40-60 0 C. Any other better medium, such as silicon fluid shall also be acceptable. Page 3 of 6

10. TERMINATIONS 10.1 The termination of the auxiliary contact of the relay shall be suitable for connecting cable of 2.5 mm 2 and 4 mm 2 stranded conductors. 10.2 The coil connection shall be suitable for bus bar or cable connection with sockets of appropriate current ratings. Extension leads shall be according to customers specification but shall not exceed 100 mm in length. 10.3 The relay shall have provision for both the front and the rear connections. 11. CONTACTS This standard stipulates one normally closed (NC) contact. However, an additional normally open (NO) contact may be provided if asked for by the purchaser. 12. DUTY CLASS AND ENDURANCE 12.1 Minimum permissible frequency of operation shall be 60 per hour. 12.2 Mechanical service life (number of on-load operation cycles) shall be 0.25 x 10 6 minimum. 12.3 Electrical endurance is resistance to electrical wear characterized by the number of no-load operating cycles. This shall not be less than 1/10 of mechanical service life. 13. TEMPERATURE RISE OF PARTS The limits of temperature rise of various parts of the relay shall be according to IS 13947 : part 4: Sec 1. 14. TESTS 14.1 Type Tests a) General inspection, b) Verification of temperature-rise limits IS 13947 : part 4: Sec 1. c) Verification of dielectric properties IS 13947 : part 4: Sec 1. and d) Verification of performance at 30 ka for five cycles Page 4 of 6

14.2 Routine Test a) General inspection, b) Dielectric test IS 13947 : part 4: Sec 1. and c) Accuracy and calibration test. 14.3 Special Tests a) Mechanical endurance test, b) Verification of mechanical duty class, and c) Electrical endurance test 14.4 A certificate shall be provided for the calibration marked on the scale. 15. MARKING Each relay shall be provided with a name-plate marked within the following information in a durable manner and located such that it is clearly visible in mounted position: a) Manufacturer's name; b) Manufacturer's type reference' c) Rated insulation voltage, rated current, ac/dc; d) Setting indication; e) Serial number/year of manufacturer; and f) Reference to IPSS. 16. All the technical details of the relay shall be given in a separate leaflet which shall include the following details: a) Overall dimensions and mounting details; b) Pick up value and drop off value of currents; c) List of all components with parts numbered; d) Internal wiring diagram; Page 5 of 6

e) Calibration curve showing operating current versus operating time characteristic at rated ambient temperature; f) Specification of oil use, in case of oil dashpot relays; g) Procedure for overhauling, maintenance, reassembly and adjustment of contact gap and pressure; h) Storage and periodicity of checking when in use; and j) Weight of the relay. Page 6 of 6