COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

Similar documents
Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Effective June 2016 New Issue

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Effective March 2015 Supersedes S August 2012

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

Type NR oil switch installation and operation instructions

Effective May 2017 Supersedes December 2004 (S )

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

Figure 1. Kearney Type HX cutout.

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

Factory Authorized Mechanism Enhancement (FAME)

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

Instruction Booklet IB E. Contents

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

CCP2-FLR1-21_ flange-rod operating mechanism

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Two-way cable interlock kit for Magnum fixed circuit breakers

3-way multi-family drawout cable interlock kit - type 32 - RF

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

Two-way cable interlock kit for Magnum drawout circuit breakers

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

COOPER POWER SERIES. Type VSA12, VSA12B, VSA16, VSA20, and VSA20A operation and installation instructions. Reclosers MN280063EN

COOPER POWER SERIES. RVAC Fluid-insulated Vacuum Switchgear; Installation, Operation, and Maintenance Instructions. Switchgear MN285005EN

Installation Instructions For Motor Control Center (MCC) Units

O & M Manual for the EATON Generator Ready Loadcenter

Effective May 2017 Supersedes October 2002 (S )

Effective October 2016 Supersedes January 2014 (S )

COOPER POWER SERIES. Type MOST Fluid-Insulated Switchgear; Installation, Operation, and Maintenance Instructions

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

K-Limiter high ampere Companion II fuse

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

Instructions for using Functional Test Kit on Digitrip 520 and 1150 family of Power Circuit Breaker Trip Units and Series G and FD MCCB Trip Units

CM52 Network Protector with Arc Flash Reduction Module

A 1.2 kv class externally removable secondary bushing

Advanced Test Equipment Rentals ATEC (2832)

COOPER POWER SERIES. Type PST Model-9 Automatic Source Transfer Switchgear with ist Control; Installation, Operation, and Maintenance Instructions

Vacuum Circuit Breaker (Vehicle)

Edison modular fuse, vault application products

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

600 A 28 kv class Cleer loadbreak connector system

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

SPX9000 FR10 FR12 Adjustable Frequency Drives

COOPER POWER SERIES. Type PST Model-9 automatic source transfer switchgear with ist control installation, operation, and maintenance instructions

ELF -LR current-limiting fuse

600 A 15 and 25 kv class Cleer grounding elbow

Flush Mount AIN ALPHA Meters. General. Hardware Kit

Transcription:

Reclosers MN280069EN Effective April 2017 Supersedes February 1982 (S280-80-19) COOPER POWER KA1169R Closing Coil Transfer-Switch Accessory Operation SERIES

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... ii SAFETY FOR LIFE... iv SAFETY INFORMATION... iv Safety instructions...iv INTRODUCTION.... 1 Read this manual first...1 Additional information...1 DESCRIPTION.... 1 Ratings...1 OPERATION.... 2 When the source side is energized...2 When the source side is de-energized and the load side is energized...2 When both the source and the load sides are de-energized...2 VERIFICATION OF OPERATION... 3 Hydraulically-controlled reclosers...3 Electronically-controlled reclosers...3 iii

KA1169R Closing Coil Transfer-Switch Accessory! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around highand low-voltage lines and equipment. G103.3 WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling, or maintenance can result in death, severe personal injury, and equipment damage. G101.0 WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury, and equipment damage. G102.1 WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install, or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.2 iv

KA1169R Closing Coil Transfer-Switch Accessory Introduction Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before operating this equipment. Ratings The closing coil transfer switch accessory is applicable for 2.4- to 14.4/24.9-kV distribution systems. It has a rated maximum voltage of 27 kv and a BIL rating of 125 kv. Additional information These instructions cannot cover all details or variations in the equipment, procedures, or process described, nor provide directions for meeting every possible contingency during installation or operation. When additional information is desired to satisfy a problem not covered sufficiently for the user s purpose, contact your Eaton representative. Description The closing coil contactor-and-transfer-switch accessory (Figure 1) allows Eaton Cooper Power series three-phase reclosers, which use a high-voltage solenoid for closing, to be energized directly from either side without the use of bulky and costly closing equipment (stepdown, low-voltage closing, etc.). The transfer switch provides a simple, selfcontained, automatic means of switching the connection for the closing solenoid coil from the source side to the load side when a closing operation is initiated while source-side power is de-energized. The accessory consists of a mechanically-operated DPST closing contactor and DPDT transfer switch. It is an alternative to the standard closing solenoid contactor of the recloser. It mounts in the same position and is operated in a similar manner. Accessory catalog numbers applicable to specific Eaton Cooper Power series reclosers and applications are shown in Table 1. Figure 1. Closing solenoid coil contactor- and transferswitch accessory mounted on recloser mechanism in place of standard closing solenoid contactor Table 1. Accessory catalog numbers Electronically-Controlled Recloser* Hydraulically-Controlled Recloser Recloser Type RVE** RXE WE WVE** VWE VWVE RV** RX W WV** VW VWV Accessory Catalog No. KA1169R5 KA1169R6 KA1169R7 KA1169R8 KA1169R11 KA1169R12 KA1169R1 KA1169R2 KA1169R3 KA1169R4 KA1169R9 KA1169R10 * When this accessory is used with electronically-controlled reclosers, it is recommended that the electronic control be equipped with the control fuse elimination accessory, KA531ME3. ** Transfer switch can be used on 2.4- to 24.9-kV distribution systems. Switch has 27-kV max design and 125-kV BIL ratings. 1

KA1169R Closing Coil Transfer-Switch Accessory Operation When the source side is energized When the recloser is locked open or when the recloser is closed, the circuit to the closing coil is opened by the DPST contactor (Figure 2). When a closing operation is initiated, the offset T-bar begins its upward travel and closes the DPST contactor which connects the closing solenoid coil across Phases B and C on the source side of the recloser (Figure 3). Since the source-side lines are energized, the closing operation is completed. As the recloser closes, the T-bar drops down to open the DPST contactor and de-energize the solenoid coil (Figure 2). Note that under these conditions, the operation is the same as the closing operation with a standard closingcoil contactor. The accessory DPDT transfer switch has not operated and is not involved in the operation of the recloser. When the source side is de-energized and the load side is energized If the source side is not energized when the closing operation is initiated, the T-bar closes the DPST contactor and continues its upward movement to operate the DPDT transfer switch. This connects the closing coil across the load-side bushings (Figure 4) and completes the closing operation. As the recloser closes, the T-bar starts its downward travel and opens the DPST contactor to de-energize the closing coil before the DPDT transfer switch operates (Figure 5). As the T-bar completes its downward movement, the transfer switch returns to its original (at rest) position, ready for the next closing operation (Figure 2). Note that the closing-coil circuit is interrupted by the DPST contactor (Figure 5). When both the source and the load sides are de-energized Upward movement of the T-bar closes the DPST contactor (Figure 3). Since source -side lines are de-energized, the T-bar continues its upward travel to operate the DPDT switch and transfer the closing-coil connections to the load side of the recloser (Figure 4). Since no load-side voltage is present, the closing solenoid contactor and transfer switch will remain in this position and the recloser will remain open. For electronically controlled reclosers, after five seconds, this condition will result in blowing the control fuse to interrupt the closing signal. The T-bar will then drop back to its at-rest position (Figure 2). This can be eliminated by equipping the control with the KA531ME3 fuse elimination accessory. Approximately two seconds after transfer to the load side, the fuse elimination accessory will interrupt the closing signal and the T-bar will drop down to its starting position (Figure 2). Then, after a 50-second pause, the fuse elimination accessory will reestablish the closing signal and the transfer switch will again interrogate both sides of the line. This cycle will be repeated until either source-side or load-side power is re established and the recloser closes. For hydraulically controlled reclosers, the sequence of operation of the closing coil contactor-and-transfer switch is the same as for the electronically controlled reclosers, except that the DPDT transfer switch will stay in the transferred position (DPST contactor also closed; Figure 5) until the yellow operating handle on the recloser is operated. When the yellow handle is pulled down, the contactor and switch will drop back to their at-rest positions (Figure 2). Therefore, when both source and load side are de-energized, the yellow handle of the recloser should be pulled down and left in the down position until either side of the line is energized. Then, the handle can be raised to initiate the closing operation. DPDT TRANSFER SWITCH DPST CONTACTOR DPDT TRANSFER SWITCH DPST CONTACTOR FUSES CLOSING SOLENOID COIL T-BAR FUSES CLOSING SOLENOID COIL T-BAR Figure 2. Contactor-transfer switch accessory in normal (at-rest) position Figure 3. When closing sequence is initiated, closing coil is connected across source side of recloser 2

KA1169R Closing Coil Transfer-Switch Accessory Verification of operation Hydraulically-controlled reclosers Refer to Recloser Installation Instructions, Service Information MN280021EN, paragraph Operation of the Closing Solenoid in the TEST PROCEDURES section. With the high-voltage transformer connected to the source side of the recloser (bushings 5 and 3) and the yellow operating handle of the recloser up in the CLOSED position, energize the high-voltage transformer T3. The recloser should close immediately. Manually open the recloser and reconnect the high-voltage transformer to the load side (bushings 6 and 4). Return the yellow operating handle up to the CLOSED position and energize the high-voltage transformer T3. The recloser should close immediately, indicating proper operation of the accessory. Electronically-controlled reclosers Refer to the Recloser Installation Instructions, Service Information MN280060EN, paragraph OPERATION, Manual, From Control Panel. With the high-voltage lines connected to the source side of the recloser (bushings 5 and 3) and energized, move the manual control switch on the control panel to CLOSE. The recloser should close immediately. Manually open the recloser at the control panel and reconnect the high-voltage lines to the load side (bushings 6 and 4). Energize the high-voltage lines and again move the manual control switch on the control panel to CLOSE. The recloser should close immediately indicating proper operation of the accessory. CAUTION At times, a recloser on a radial feed system may be equipped with the transfer switch accessory to permit closing from the load side during emergency backfeed operations or simply for interchangeability with other reclosers used in dual-feed applica tions. For an application where the load side will not normally be energized, loss of source-side power during the instant a closing signal is initiated (due to a backup device trip, for example) could result in a false recloser lockout. For electronically controlled re closers, the fuse elimination accessory will prevent blowing the control fuse and locking out the control. The fuse elimination accessory will cycle the closing signal in a two-secondon, 50-second-off sequence until the source -side voltage is reestablished and the recloser closes. This cycling can con tinue for as long as 15 hours before a fully charged control battery is dis charged. For hydraulically-controlled reclosers, this problem can be eliminated by reversing the recloser installation (con necting the source to the load-side bushings). With this type of installa tion, the transfer switch would first connect the system load side to the closing coil and then transfer to the source side, remaining in that position until source voltage is restored. DPST CONTACTOR DPDT TRANSFER SWITCH DPST CONTACTOR DPDT TRANSFER SWITCH FUSES CLOSING SOLENOID COIL T-BAR FUSES CLOSING SOLENOID COIL T-BAR Figure 5. Contact-de-energized closing coil before transfer contacts operate Figure 4. If source side is de-energized, continued travel of T-bar will transfer closing coil to load side of recloser 3

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN280069EN KA2048-0197 REV 01 April 2017 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.