RECTANGULAR EXTRACT FANS

Similar documents
Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

HIGH TEMPERATURE TWIN SQUIF FANS

NEW Slimpak EC Box Fan (SLPT EC)

Hybrid. DUTIES UP TO 0.95 m 3 /s (950 l/s) Ecovent Hybrid part of a complete range of innovative, flexible products from the HVAC experts

Sentinel D-Box Twin Fan

Duties up to 7.5 m 3 /s

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Sentinel D-Box Single Fan

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Sapphire Horizontal Waterside Control Fan Coil Units

QUBE SQU-HT(S) Product Brochure

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

Air terminal devices

Fan - Powered Terminal Unit Series Flow

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

CYCLONE F 400 smoke extraction casing

QUIETSCROLL TWIN FAN RANGE

AC Commercial Fans Edition. ErP ready

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Square Mixed Flow Fans (MFQ)

to obtain the specified voids due

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

SQUIF HIGH TEMPERATURE FANS

ACOUSTIC CABINET FANS CVB / CVT Series

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

QC RANGE ACOUSTICALLY LINED SINGLE BOX FANS PUREAIR KENT LTD ERP 2015 COMPLIANT

Catalogue. FlowBar. High Capacity Slot Diffuser.

Novenco axial flow fans. ZerAx - Standard January 2010

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

ifan Copford Box Range

CONSTANTFLOW Volume Flow Controllers

NEW Acoustic In-Line Fans (ACQ)

Bifurcated Case Axial Fans (BIFA)

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Ceiling products Acoustic performance data

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

Mixed Flow Roof Fans (RMH)

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

3ph Belt Drive, Run & Standby, Roof & Plantroom Twinfans

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

Acoustic Twin Fans (ATQ)

AXUS HIGH TEMPERATURE AXIAL FANS

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Series VTI Quiet Cased Twin Extract Fan Unit

Mixed Flow Roof Fans (RMH)

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

low profile duct system

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

INHERENTLY QUIET AND POWERFUL 180 MM DEEP SLIMLINE HORIZONTAL WATERSIDE CONTROL IN CEILING

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Sabre Plate Mounted Sickle Fans (VSP)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Extract-air grille with ATK plenum box

HILLSTONE DC LOAD BANK

SILENT MV Ultra Quiet In-line Fans

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Floor Swirls Models BZD and SZD

Warning. Document ref: A October 2015

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

FlowBar High Capacity Slot Diffuser

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

VARYCONTROL VAV Dual Duct Terminal Boxes

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Actionair Control and Shut Off Dampers

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

J L I e x h a u s t h o o d

Ventilation grilles for installation into walls, sills or rectangular

AXIAL FANS Catalogue CN0050C01 May 2008

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

AIR-AIR ENERGY CONSERVATION MODULE

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

BIFLOW SB CON Product Brochure

Uniclass L7534. Manufacture controlled to ISO9001

Roots Packaged Blower Units

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

SDV Vane Swirl Diffusers

Transcription:

RECTANGULAR EXTRACT FANS Wide duty range 0.05m 3 /sec to 3.2m 3 /sec Horizontal or vertical mounting Quick and easy to install VES EXTRACT FANS part of a complete range of innovative, flexible products from the HVAC experts

RECTANGULAR EXTRACT FANS Why choose VES VES has been supplying products for the HVAC industry for over 40 years, and have the in-depth knowledge and resources to provide solutions to all ventilation related requirements. We are a substantial British manufacturing company with over 200 employees, several factories plus a regional base in the north of England, and sales engineers located throughout the UK. Complete range of products The product range encompasses all types of ventilation products, including those required for commercial, industrial, public and domestic buildings. The emphasis is on low energy products and sophisticated controls to meet the requirements of the Building Regulations. The range extends from a small bathroom extract fan up to a mighty central station air handling unit. There are specialist heat recovery units, high temperature fans for kitchen hood extract; duct, wall, ceiling and roof units; low noise products and silencers; fitted controls. High quality, flexible solutions VES operate a quality assurance system to ISO 9001, monitored by the BSI. The air movement products are tested in-house to BS 848 Part 1, and submitted for external testing and approval when necessary. VES specialise in bespoke designs for ventilation units, and whatever the issue, be it space, noise, temperature etc, can provide a design solution to meet the requirements of the project. Introduction The VES REX rectangular extract fan is suitable for internal use. With horizontal or vertical mounting and five sizes of unit the REX units are suitable for a wide range of applications. REX is simple to install, commission and maintain. Features and Benefits f Five sizes of unit with air volumes from 0.05m 3 /sec to 3.2m 3 /sec. f Optional single or double skinned case. f Accessories include matching silencers and speed regulators. f Easy maintenance - fan plate side withdrawable. f Horizontal or vertical mounting. f Tough case construction in galvanised sheet steel with optional powder coat paint finish. f Quick and easy to install on site. f Units available with side withdrawable disposable cell filter. f All units tested in accordance with BS 848, ensuring guaranteed performance. Superior customer service From the moment we receive your enquiry to delivery and beyond, we have the people in place to give excellent customer service. The VES after sales service covers the whole of the UK and is among the best in the industry. Experience and expertise VES employ a range of experts in disciplines including air movement, noise control, air conditioning, controls, electrics and product refurbishment, and we have key staff who have worked at VES for many years. Manufactured in the UK VES has over 12000m 2 of manufacturing and stores space, and has state of the art sheet metalworking equipment, plus a large powder coating plant. VES also has a substantial controls department, and makes components such as dampers and electric heaters in-house. This not only provides employment for local people, but also many suppliers around the UK. 2

REX Sound Data Sound levels - Sound power level db ref 10-12 w PWL Fan SPL Centre Frequency - Hz Size *dba 63 125 250 500 1000 2000 4000 8000 1 44 65 61 56 55 55 53 51 47 2 46 69 66 58 57 57 55 53 49 3 47 69 66 59 58 58 56 54 50 4 58 69 70 64 69 69 57 65 61 5 58 71 70 64 68 69 57 66 60 6 64 75 76 70 72 75 75 73 67 7 62 73 75 68 72 74 73 70 65 8 64 76 77 70 72 72 71 70 64 9 64 75 76 71 74 74 75 73 68 10 71 83 84 80 81 82 81 69 72 Noise breakout - Sound pressure levels SPL dba at 1 and 3 metres from case Single Skin Case Double Skin Case Fan dba NR dba NR dba NR dba NR Size @1m @1m @3m @3m @1m @1m @3m @3m 1 37 35 32 30 32 30 27 25 2 39 35 34 30 34 30 29 25 3 40 35 35 30 35 30 30 25 4 51 45 46 40 46 40 41 35 5 51 45 46 40 46 40 41 35 6 57 55 52 50 52 50 47 45 7 55 50 50 45 50 45 45 40 8 55 50 50 45 50 45 47 40 9 57 55 52 50 52 50 47 45 10 64 60 59 55 59 55 54 50 3

RECTANGULAR EXTRACT FANS REX Selection Charts REX 1 To specify the unit you require: Case size 1, Fan size 2 = Model REX 12 REX 2 E.g. REX 24 / F REX 3 The size 6 fan can also be required, E.g. Model REX 26 combination, but not above 0.6m 3 /sec due to air velocity 4

REX Selection Charts REX 4 The REX 48 is available with 1 or 3 phase motor. The size 8-1 phase fan must not be used below 100 Pa operating pressure. If the system pressure is below this an iris damper REX 5 The REX 59 is available with 1 or 3 phase motor. The REX 510 is only available with 3 phase motor. The size 9-1 phase fan must not be used below 200 Pa operating pressure. If the system pressure is below this an iris damper 5

RECTANGULAR EXTRACT FANS Dimensions REX 1-4 Units A - Overall Width D - Duct Width C - Overall Width 100 100 B Overall Height E Duct Height Width D x Height E Width D x Height E H - Hole Centres F - Centre of Feet G - Feet Length Access panels and electrical connections are available either left or right hand side looking in Optional Filter: Specify REX 36 / F There is no increase in length REX Units 1-4 Dimensions - mm Dimensions - mm Weights - Kg Model A B C D E F G H Single Skin Double Skin 1 600 325 445 550 275 365 750 670 16 23 2 750 480 575 700 430 495 900 820 36 51 3 850 550 720 800 500 640 1000 920 56 84 4 950 650 750 900 600 670 1100 1020 81 124 Mounting Feet and Anti-Vibration Mounts 6

Dimensions REX 5 Unit Access panels and electrical connections are available either left or right hand side looking in REX 5 Weights Extra for Kg Filter Section Single Skinned - 93 9 Double Skinned - 106 17 Flexible Connections Location Width Height (mm) (mm) To unit inlet 1200 700 To silencer 800 700 To discharge spigot 650 600 Inlet Plenum Box Model SAMPL5 REX Filter Size Filter Part Model (mm) Number 1 550 x 270 x 50 SAMDF 1 2 700 x 425 x 50 SAMDF 2 3 800 x 495 x 50 SAMDF 3 4 900 x 595 x 50 SAMDF 4 5 695 x 598 x 100 (2 No.) SAMDF 5 7

RECTANGULAR EXTRACT FANS Electrical Details Motor Output FLC Amps Speed Speed Fan Watts Max RPM Regulator 1 73 0.4 900 T1 2 92 1.1 1300 VS2 3 125 1.3 850 T1 4 250 2.8 910 VS6 5 250 2.8 910 VS6 6 550 6.1 1380 VS6 7 550 8.0 1380 T8 8-1ph 750 5.8 910 T8 8-3ph 1100 3.5 910 SC310 9-1ph 2600 12.2 820 T12 9-3ph 2700 6.3 850 SC310 10-3ph 2700 6.5 850 SC310 Fan Speed Controllers Dimensions (mm) Model Width Height Depth VS2 90 150 45 VS6 95 145 50 T1 120 190 65 T8 160 230 120 T12 190 250 130 SC310 223 320 110 VS2 VS6 T1 T8/T12 SC310 8

Silencers REX unit, on both the inlet and outlet. The splitters and side liners are non-combustible attenuating material. The silencer case is galvanised sheet steel with 25mm proprietary The VA5 silencer is narrower than the REX 5 case, and is located centrally. Should an inlet between the unit and silencer. Dimensions - mm Silencer To fit Weight Model REX Width Height Length FW FH Kg VA1 1 550 275 1000 600 325 23 VA2 2 700 430 1000 750 480 37 VA3 3 800 500 1000 850 550 44 VA4 4 900 600 1000 950 650 62 VA5 5 800 700 1200 850 750 60 Attenuation Insertion Loss, db Centre frequency - Hz Model 63 125 250 500 1000 2000 4000 8000 VA1 4 8 14 28 36 36 28 22 VA2 4 7 13 25 32 32 23 18 VA3 5 9 16 30 39 39 31 26 VA4 4 8 14 28 36 36 28 22 VA5 4 7 13 25 32 32 23 18 Silencer Air Pressure Loss 9

RECTANGULAR EXTRACT FANS Product Specification REX Rectangular Extract Fans 1.1 Quality Standards All units tested to BS 848 Part 1. 1.2 Case support. 1.3 Fan Forward curved centrifugal fan, multi-vane, double inlet double width, direct driven by hub mounted motor. The motors in all 1.4 Filter (Optional) at a face velocity of 1.5m/sec. 1.5 Silencer attenuating material. The splitters are supported with galvanised sheet steel frames, and the silencer case is galvanised sheet steel of lock formed 10

1 2 3 4 5 6 7 8 1 1 page HIGH EFFICIENCY HEAT RECOVERY low energy fans fitted controls with touch screen remote wide range of models for ceiling void, plantroom and outdoor location L2 compliant classroom unit All units suitable for demand ventilation using a VES air quality sensor VES AIR HANDLING UNITS part of a complete range of innovative flexible products from the HVAC experts March 2010 Maintainance 6 Continued Caution Fan assembly removal Fig. Fan assembly removal Fig. Heat exchanger removal Fig. VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF Tel: 08448 156060 Fax: 02380 261204 E-mail: vesltd@ves.co.uk Web: www.ves.co.uk Installation, Operation and Maintenance Manual 10 ORIGINAL INSTRUCTIONS All NRGP units feature plug & socket connections to allow easy removal/replacement of key components. For fan removal follow the instruction below. Separate the plug connection by hand (tools not required) by lifting the locking lever plug/socket apart. DO NOT pull the cable to separate the assembly. and pulling the On reconnection, the connection features a locating lug to ensure correct orientation. Once rejoined,lock the connection together again using the locking lever as shown. The fan support is held into place with 4 M6 fixings located on the inlet side of the fan bulkhead as shown below. Ensure when replacing the assembly that all fixings are replaced correctly. Please note, that on bottom access units, an addition M6 setscrew fixing is used, located between the fan impellor and the casework. Ensure when reinstating the unit that all fixings are replaced correctly and check that the fan impellors are free running. Adjust as necessary for correct alignment. For bottom access units, should it be necessary to remove the heat exchanger from the unit casework take care to ensure that all components are correctly supported during their removal. Remove the lids and central mullion from the unit, exposing the bypass damper. As an additional safety measure the bypass is held into place using PK screws as shown. Remove the required components with with care and ensure all components are replaced correctly. Product informa on at your finger ps Brochures CENTRIFUGAL ROOF EXTRACT UNITS for volume and pressure VERSATILE EXTRACT FAN UNITS FOR HIGHER AIR TEMPERATURES AND PRESSURES Duty range 0.15 to 7.0m 3 /sec Motor out of airstream Up to 90 C operating temperature Easy to clean Inverter speed control Low specific fan power VES ROOF EXTRACT UNITS part of a complete range of innovative flexible products from the HVAC experts VES AIR HANDLING UNITS part of a complete range of innovative flexible products from the HVAC experts O&Ms VES products have never been easier to select. Important VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF Tel: 08448 156060 Fax: 02380 261204 E-mail: vesltd@ves.co.uk Web: www.ves.co.uk ecovent NRGP Air Handling Units Installation, Operation and Maintenance Manual Warning Caution Important Contents Introduction ORIGINAL INSTRUCTIONS VES Ref. ID.880a This manual must be read in full before Installation, Operation and Maintenance of the units supplied Please ensure that this document is passed to the end user. This manual forms an integral part of the product and should be kept for the working life of the product. Additional copies of this and supporting documents are available by contacting VES or by visiting www.ves.co.uk and following the 'Download O & M's' link. The following symbols used within this document refer to potential dangers, advice for safe operation or important points of reference Indicates hazards associated with electric current and high voltages Indicates hazards that require safety advice for personnel or potential unit/property damage Indicates important information Introduction 1 Nomenclature 2 Receipt of Goods & Handling 4 Installation 4 Standard Wiring & Fan Installation 7 Maintenance 9 Declaration of Conformity 12 Extended Warranty The NRGP series is a range of air handling units, with duties upto 0.4m³/s. Suitable for either plantroom, ceiling void or external locations. As standard, each unit will have been supplied pre-wired to an external isolator(s) or fitted control panel, as specified at the time of order. The standard operating temperature of these units is -20 to +35 C. For further technical details regarding dimensions and weights, contact VES on 08448 15 60 60, quoting the sales order (SO) number and the unit type as found on the unit nameplate, or alternatively visit www.ves.co.uk. ecovent NRGP Air Handling Units Specifica ons Product Literature VES produce high specifica on, comprehensive brochures for a wide range of our products. You can order hard copies or simply download the pdf s from our Informa on Centre at www.ves.co.uk. Easy Specifica on There are also comprehensive O&Ms to support every unit we sell, as well as handy specifica on sheets. Innova ve solu ons from the HVAC experts: Call us today to discuss your requirements on 0800 31 66 000, or email info@ves.co.uk www.ves.co.uk 11

Other products and services from the complete range of VES HVAC solutions: Air Handling Units: Duct Fans: Twin Fans: Roof Extract Units: Wall and Ceiling Fans: Kitchen Hood Extract Fans: Control Panels: Noise Control: Specialist Site Services: Buy from 2011 2010 VES VES Issue REX02 DF01 - - 03/2010 08/2011 ISO 9001:2008 Cert. No. Q05375 www.vesdirect.co.uk VES reserve the right to amend product specifications and details without notice. VES Eagle Close, Chandlers Ford Industrial Estate, Chandlers Ford, Eastleigh, Hampshire SO53 4NF, UK Tel: +44 (0)8448 15 60 60 I Fax: +44 (0)23 8026 1204 I Email: info@ves.co.uk www.ves.co.uk