Industrial Fluid Controls

Similar documents
Manufacturers of liquid level controls for overfill prevention.

ROTARY Point Level Measurement for Inventory Control

Mobrey 003 Ultrasonic Liquid Level Switch

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement Point level measurement - RF Capacitance switches

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

RS85 Vibrating fork level switch

Cryogenic Dry Disconnects and Breakaway Couplings. dixonvalve.com Customer Service:

R F C a p a c i t a n c e TrueCap

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

Valve Position Monitors

Point level measurement Capacitance switches

Tank Filling Systems. for Petroleum Products

RF Point Level Control with Sensor Monitor

PROCAP Capacitance Level Sensors

Valve Position Monitors

Tank Filling Systems for Petroleum Products

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

PROCAP Capacitance Level Sensors

Dixon Sanitary General Products. dixonvalve.com Customer Service:

ISTEC MAGNETIC METERS

Why measure viscosity in-line?

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

LIMIT SWITCHES & POSITION INDICATION

NOW UL LISTED. Patented

Bayloc Dry Disconnects

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Installation, Operation & Maintenance Manual. Bulletin: IOMS-PUL CHEMAlarm LEAK DETECTIONI

MAGNETIC LEVEL GAUGES

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

Mobrey 003. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP117, Rev DA. Self-contained liquid level alarm.

Level Measurement Point level measurement - RF Capacitance switches

TotalPac 3 Firecyle III Wet pipe Remote controlled system

Mobrey Squitch 2 Ultrasonic Liquid Level Switch

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Installation and Operating Manual

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Super-Safe-Plus Roto-Bin-Dicator

Bayloc Dry Disconnects

Relay Contact Ratings. Operating Temperatures. Life Expectancy. Humidity Tolerance Enclosure Mounting Weight

TRANSPARENT GLASS MAGNETIC LEVEL GAGES INDICATORS REFLEX GLASS

CAPACITANCE LEVEL SWITCH

V200 Series Positioners

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

V200 Series Positioners

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

PRO REMOTE Series CAPACITANCE PROBE

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

Shock/Vibration Control Switches

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

V200 Series Positioners

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

THE ORIGINAL DRY BULK LEVEL MEASUREMENT & CONTROL

7330 Pro-Stik II Magnetostrictive Level System

ELECTRIC ACTUATORS. Series 70 Pgs 4-11 PRODUCT QUALITY & PRECISION INTRODUCTION

TotalPac 3 Deluge, Electric release Remote controlled system

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Customized Solutions. Safety & Reliability Stainless steel 316 products

Water Valve Shutoff. WVS Water Valve Shutoff

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

OutdoorXUPS-600AHV-8364

LIMIT SWITCH BOX MODEL - APL

Ultrasonic Two-Wire Point Level Control

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Redundant Control System

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Explosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Mobrey dry products level measurement and control

* * Rev. 9 01/18 Product Manual

Z4-Series DREXELBROOK DATA SHEET. Easy-Installation. Z-tron IV Point Level Switch, a reliable low-cost, on/off level switch.

Updated: October 2012

OPTISWITCH 4000/5000. Vibration level switches for liquids

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

LTX RF LEVEL SENSOR. Instruction Manual

2N1 TM PROXSENSOR ACCESSORIES VALVE STATUS MONITOR SERIES 52 2 INDUCTIVE PROXIMITY SENSORS AC, DC & INTRINSICALLY SAFE VERSIONS

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.

DIESEL Engine Fire Pump Controllers Features

GENSET CONTROL MODULE A121A / A241A

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

3D TRASAR Automation - Boiler Blowdown Equipment

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

Bin-Dicator FEATURES AND BENEFITS

Prism PI Intelligent features offer advanced performance

Innovative Controls Inc. SL Series Tank Level Monitor

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

HFS - High Frequency Limit Level Sensor

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

ICL Three Pump Controller

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Application Engineering

Transcription:

UFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTU Industrial Fluid Controls Manufacturers of liquid level controls for overfill protection Customer Service: 513.874.8499

Automated Design Service, Inc. (ADS) is now operating as Dixon Industrial Fluid Control to manufacture products specifically designed for liquid terminal operations. Our standard product offering is shown on the following pages. However, there are numerous additional applications, materials and custom designs available. Please call 513.874.8499 or 877.582.3569 for technical information or assistance with ordering these products or visit /ADS ADS Outalarms with Probe specifically designed for liquid terminal operation on batch loading and overfill protection, tank cars, tanks trucks, marine barges, suitable for open and closed dome Sizes: 24", 36", 48" and 60" probe lengths standard, other lengths available wetted materials: 316 stainless steel, PTFE standard, other materials available totally self-contained; no wires, tubing or external power rugged weather and corrosion resistant construction no moving parts, tip sensitive phase shift digital capacitance sensor for conductive and nonconductive fluid, conductivity sensor with integral splash shield requires no calibration or adjustment adjustable insertion length through a standard ½" NPT fitting high intensity audible and flashing visual outputs optional opto-isolated solid state contact output full, hard graduated laser engraved rod A100 operates up to 2500 hours on a single 9V alkaline battery fail safe continuous battery monitor goes to alarm state on low battery battery current drain <0.23 ma during standby; <50 ma in alarm state Specifications: minimum dielectric constant 1.7 temperature range: capacitance probe: -14 F to 250 F (-26 C to 121 C) high-temp capacitance probe: -14 F to 325 F (-26 C to 163 C) activation point ¼" above liquid surface compatible with any liquid or dry bulk material with a dielectric constant of 1.7 or greater horn intensity 101 db at 2' light output 3 each 3000 mcd high intensity flashing LED's pressure rating on standard unit: 50 PSI, consult Dixon for applications up to 300 PSI Approvals: intrinsically safe design per ANSI/UL913 for Class I, Div I Groups A, B, C and D Hazardous Areas A100 Probe A100 capacitance probe Capacitance 250 F (121 C) max Hi-temp Capacitance 325 F (163 C) max Conductivity for conductive fluids 12" A100C12A A100HC12A A100CSS12A 24" A100C24A A100HC24A A100CSS24A 36" A100C36A A100HC36A A100CSS36A 48" A100C48A A100HC48A A100CSS48A 60" A100C60A A100HC60A A100CSS60A 72" A100C72A A100HC72A A100CSS72A 84" A100C84A A100HC84A A100CSS84A 2 513.874.8499

ADS Spillguard Systems s h utdown and alarm system for tank cars, tank trucks, barges and ships, suitable for open and closed dome Sizes: standard cable lengths: 15', 25' and 50', other lengths available insertion lengths 4" to 60" standard, other lengths available wetted materials: 316 stainless steel and PTFE standard, other materials available controller housing NEMA 4X, NEMA 7, Explosion Proof, Class I, II, Groups B, C and D probe monitor rugged, explosion proof, weather, chemical and corrosion resistant LED status lights visible through glass cover inserts into tank through standard ½" NPT fitting probe can be portable or permanently installed in the vessel laser engraved graduated rod with ¼" graduations probe-to-controller cable protected by stainless steel interlocking armor sheath and heavy duty latching connectors at both ends fail safe design, unit trips in the event of an open or shorted cable or loss of power choice of capacitance, conductivity, ultrasonic, temperature or float sensors input power: 120 VAC, 240 VAC or 24 VDC, 2.5 watts output relay de-energizes on high level, broken or shorted sensor cables or loss of power sensor excitation open circuit voltage 8 VDC, short circuit current 8 MA with built-in FM approved barrier optional self test feature, tilt and ground verification interlocks and latching circuit available cable Specifications: probe temperature range: -14 F to 212 F (-26 C to 100 C) probe pressure rating: 50 PSI with standard fitting, consult Dixon for applications up to 300 PSI sensor suitable for Class I, II, III, Div 1, Groups A, B, C and D when used with supplied controller and cable lengths of 10,000' or less output relay contacts 2 form C (2PDT) rated 2 amps at 120/240 VAC, 1 form C (SPDT) with optional latching circuit and reset switch Approvals: c a ble connectors designed for repeated mating meet IP 65 mechanical and environmental specifications FM, CSA HAZ Loc Class I Div I, Groups B, C and D A210 Spillguard Monitors Monitor Options 24V DC 120V DC A210 Spillguard monitor A210-24 A210-120 with bypass timer A210B-24 A210B-120 with external reset switch A210R-24 A210R-120 513.874.8499 3

ADS Spillguard Probes f or materials with dielectric constant > 1.7, liquids, powders, slurries probe: 316 stainless housing: NEMA 4X, IP66 Capacitance Probes ½" NPT sliding fitting standard, ¾" fitting optional open dome adapter and washout fitting available tilt sensor optional Specifications: capacitance probe: 250 F (121 C) maximum high temp probe: 325 F (163 C) maximum Capacitance Capacitance High-Temp 12" A200PC12A A200PHC12A 24" A200PC24A A200PHC24A 36" A200PC36A A200PHC36A 48" A200PC48A A200PHC48A 60" A200PC60A A200PHC60A 72" A200PC72A A200PHC72A 84" A200PC84A A200PHC84A Conductivity Probes for conductive fluids such as acids and water based mixtures probe: 316 stainless, Hastelloy available for HCL service housing: NEMA 4X, IP66 ½" NPT sliding fitting standard, ¾" fitting optional open dome adapter and washout fitting available pressure and tilt sensor options single electrode protected in housing dual electrodes exposed for easy cleaning Conductivity Single Electrode Dual Electrode 12" A200PCSS12A A200PCSSDP12A 24" A200PCSS24A A200PCSSDP24A 36" A200PCSS36A A200PCSSDP36A 48" A200PCSS48A A200PCSSDP48A 60" A200PCSS60A A200PCSSDP60A 72" A200PCSS72A A200PCSSDP72A 84" A200PCSS84A A200CPSSDP84A Float Probes for use with foaming, very low density, or highly viscous liquids probe: 316 stainless, Hastelloy available for HCL service housing: NEMA 4X single point standard, dual or multi-level float available open dome adapter and washout adapter available A100 battery powered monitor A100 Outalarm Float Probe A200 Float Probe 24" A100F24DA A200F24DA 36" A100F36DA A200F36DA 48" A100F48DA A200F48DA Muti-Point Ultrasonic Probes for use when multiple detection points are required such as dribble mode, pump shutoff and overfill alarm Up to 5 sense points available pressure sensor ground verification tilt storage probe only active in vertical operational position ADS Spillguard ultrasonic probes are built special order to customer specifications. Contact Dixon Bayco at 513-874.8499 to discuss with our technical specialists. 4 513.874.8499

ADS Outage Gauges Applications: set level fill point for manual / visual fill control measure outage requirements on mobile tanks Material: 316 stainless steel Feature: open dome bracket Standard Outgauge Outgauge with J Bar 2' A800OG2 A8000GJ2 3' A800OG3 A8000GJ3 4' A800OG4 A8000GJ4 5' A800OG5 A8000GJ5 outage gauge with J bar outage gauge laser engraving closeup Setting Outage on Closed Dome with A100LT Locating Tab 1. Screw washout adapter on to washout nozzle 2. Withdraw gauge rod until tab touches inside shell of tank. Note reading on rod. 3. Add desired outage to reading and push down rod to the calculated reading. 4. The probe sensor is now at the desired outage. Setting Outage on Open Dome Operation 1. Clamp bracket to vertical section of dome. 2. Withdraw gauge rod until bar touches inside shell of tank. Note reading on rod. 3. Add desired outage to reading and push down rod to the calculated reading. 4. The bar is now at the desired outage. 5. For tanks with manway protruding past shell, use J-bar gauge. 513.874.8499 5

ADS Gauge Rods used to gauge liquid levels in any mobile tank Size: ½" x.065 weight hardened 316 stainless steel laser engraved scale with ¼" graduations rods come in two sections that screw together at the midpoint foot marks inscribed on rod at 1' intervals below the inch mark heavy duty plastic handle laser engraving closeup Part Number ADS4R ADS8GR ADS12GR Description gauge rod, 4' length, one piece gauge rod, 8' length, two piece gauge rod, 12' length, two piece ADS Spillguard Cables 3 or 5 pin connector 316 stainless steel armoured cable or yellow rubber cable custom lengths available, call 513.874.8499 or 877.582.3569 for more information Armored Cables 3 Pin 5 Pin 15' A200CA3P15 A200CA5P15 20' A200CA3P20 A200CA5P20 25' A200CA3P25 A200CA5P25 50' A200CA3P50 A200CA5P50 Rubber Cable 1 3 Pin 25' A200CB3P25 1 Note: For use with (-M) mini connectors only. 6 513.874.8499

ADS Parts and Accessories Part Number A100DA A100DB A100TTB A100ST A100CA1050 A100CA1050V A100SG-POLY A100LT A100MTR A100CBLMTR A2100CR-3 A210CR-5 A210PZH-24 A210-120TC Description open dome adapter ½" NPT open dome adapter ¾" NPT tank truck 3" wash-out adapter, ¾" NPT self test fitting, 316 stainless steel, ¾" NPT 1" cam and groove coupler and ½" NPT bushing, stainless steel 1" cam and groove coupler with ½" NPT busing and 1" NPT vent tee, stainless A100 / 200 splash guard, with 1⅛" diameter poly locating tab for A100 / 200 probes replacement A100 monitor only cable to monitor adapter cable junction box 3-pin cable junction box 5-pin A210 Piezo horn 24VDC tri color external signal light A100DA / A100DB A100TTB A100ST closed position (normal) open position (for cleaning) A100SG-POLY A100LT A210PZH-24 A210-120TC 513.874.8499 7

Dixon, founded in 1916, is a premier manufacturer and supplier of hose couplings, valves, dry-disconnects, swivels, and other fluid transfer and control products. The company s global reach includes a wide range of products for numerous industries including petroleum exploration, refining, transportation, chemical processing, food & beverage, steel, fire protection, construction, mining and manufacturing. Dixon s strategic objective is to create solutions that make products safer, leak-free, longer lasting, and always available. Customer Service: 513.874.8499 Industrial Fluid Controls Cincinnati, OH 45246 ph 513.874.8499 2017 DVCC Printed in the USA ADS817inhouse