HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Similar documents
HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

Accessories. Series REC

RKB. Heat recovery units from 100 to m 3 /h >50 %

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

Air Cooled Packaged Units

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

AQVSL/AQVSH STAR 85 to 140

CH5000 Heat Recovery Ventilator

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

High Static Pressure Duct Fan Coil Unit

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Everest XV. ErP. High Efficiency HRV Fan Unit READY

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Prepared By : Checked By : Approved By : Page 1 out of 6

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

TECHNICAL MANUAL SOFFIO Ducted units

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

ifan Copford Box Range

DIRECT-AIR ILB / ILT Series Rectangular duct fans

technical catalogue tetris KW Chiller and heat pumps air/water

RECU-NOVO. heat recovery unit

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

HERU 90 LP EC HERU 90 LP EC

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series

series RVV Variable flow rate controllers

BASTONE (dual) fancoil Units

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

ROOF FAN ROOFMASTER STEC

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

AQWL/AQWH/AQWR 1404 to 2406

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

CATCH THE OPPORTUNITIES OF NEW REGULATIONS

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

VAV Terminal Units SDS

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Centrifugal fan with highly efficient EC drive motor

Ductable water unit FWD UNT-PRC002-E4

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Sentinel D-Box Twin Fan

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

UMXCA/UMXCBA ECVA/ECVBA

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Swimming Pool CSR2 Heat Recovery Equipment

D M S 760 C01 A A 1 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

WQL/WQH/WQRC 524 to 1204

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

Ducted Split System Air Conditioners

Uniclass L7534. Manufacture controlled to ISO9001

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

CornerAir. CornerAir. Active chilled beam

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

AHN 064 to 304 EHN/CHN 064 to 304

The World Leading Air-conditioning Company

NEW Slimpak EC Box Fan (SLPT EC)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

AZURA. Air/water multifunctional chiller&heat pump, kw

Transcription:

4 Lmf Clima 6 HRH High efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4.3 m³/h The HRH units have been designed for non-residential applications for which a forced and mechanical air changeover is requested. In accordance with the new EU 3/4 norm, they are equipped with a high efficiency counter-flow plate heat recovery unit (in conditions, superior to the minimum efficiency prescribed by the law of 67%), with filters with extremely low pressure drops (F7 on fresh air and M on room air exhaust, efficiency calculated according to EN 779:) and with backward-curved blades fans, directly coupled with EC motors, guaranteeing power absorptions well below the limits indicated by the norm. The casing is made with double skin panels, with mm thick rockwool insulation with fire reaction class ASd; external panels are in prepainted steel, internal panels in galvanized steel. Integrated by-pass system with actuator, for free-cooling operations. Access to fans and filters sections is ensured by doors with hinges and locking devices; additional access is given to the filters thanks to lift-off panels. The units are complete with an electronic control box for the setting of the ventilation and temperature, monitoring of the status of the filters, week programming, defrost management and anti-freeze device for the additional water coil module. >7 % EU 3-4 COMPLIANT PLUG&PLAY EC FANS EFFICIENCY HORIZONTAL ORIENTATION VERTICAL ORIENTATION

Lmf Clima 6 4 Accessories Electric heater for PRE or POST heating External module with water coil (change-over use) External module with R4A direct expansion coil CDX Face/top/bottom air damper (only with ) SKR Side air damper (only with ) SKR ON/OFF damper actuator SSE Modulating 3-way valve with actuator V33 Filters differential pressure switch PSTD Differential pressure transducer DPS Ductable CO probe AQS Roof cover for base unit (horizontal versions) TPR-H Roof cover for base unit (vertical versions) TPR-V Roof cover for module (horizontal versions) TPR-CH Roof cover for module (vertical versions) TPR-CV Flexible connection - upper/lower (only with ) GAT Flexible connection - side (only with ) GAT Round adapter for circular ducts - upper/lower (only with ) Round adapter for circular ducts - side (only with ) Plenum with multiple connections ALUMINIUM PLATES HIGH EFFICIENCY HEAT RECOVERY UNIT INTEGRATED MULTIFUNCTIONAL ELECTRONIC CONTROL STEEL SUPPORT BEAM INSIDE FULL OUTSIDE

4 Lmf Clima 6 Models HRH 3 4 Airflow rate Nom m³/h 4 8 3 9 8 38 m³/s,,,36,8,778,6 External static pressure () Nom Pa 6 7 9 7 m sound pressure level Nom db(a) 3 3 4 6 6 6 Overall power input Nom 33 34 9 93 8 9 W Max 34 34 9 93 Overall input current Nom,7,9 6, 6, 3, 3,4 A Max,8,9 6, 6, 3,4 3, Power supply V-Ph-Hz 3-- 4-3+N- Fan speed control - V External leakage max 3,% @ -4 Pa (EN 34-7) Internal leakage % max,% @ + Pa (EN 34-7) Yearly filter energy consumption kwh 476 79 33 6 48 39 Recovery efficiency () % 86, 83,4 83,7 84, 83,4 83, Recovery capacity () kw 3 64 984 44 86 Supply temperature () C 6,3,,6,7,, CONFORMITY TO EU 3/4 Recovery efficiency (3) % 79, 76, 76, 76, 76, 7,8 Efficiency bonus W/m³/s 36 7 76 8 7 64 Filter correction factor - SFP int limit W/m³/s 4 437 4 46 33 36 Total internal air pressure drop (3) Pa 7 7 693 64 76 76 Overall fan static efficiency (4) % 47,3,6 48,8 46, 6,4 8,3 SFP int W/m³/s 33 39 4 4 3 3 WORKING LIMITS Air temperature C - 4 Air relative humidity % 9 Working environment Not explosive, not corrosive, not chlorinated, not saline Capacity kw,, 4,, 7,, ΔT () C 9,8 9, 9, 7,7 7,9 8, Air pressure drop () Pa 6 Power supply V-Ph-Hz 3-- 4-3+N- Cooling capacity (6) al,46 4,47 6,83,6 6,4,68 kw sensible,3,4 3,76,84 8,7,37 Heating capacity (7) kw 3,3,86 9,34 4,3,83 7, Water flow rate (6) l/h 43 76 88 836 77 364 Water pressure drop (6) kpa 8 9 3 9 Air pressure drop (6) Pa 3 4 Weight kg 8 3 3 4 8 Nominal connection diameter mm 3 3 4 Connection strip mm Nominal air pressure drop Pa 7 7 6 9 6 () Fresh air/supply air circuit () At wet conditions : outside air temperature 7 C 8% RH, room air temperature C % RH (3) At conditions : outside air temperature C, room air temperature C (4) Including motor & speed controller efficiency () At nominal airflow rate (6) Air inlet condition 8, C 6% RH; in/out water temperature 7 / C (7) Air inlet condition 3 C; in/out water temperature 4 /4 C

9, 9 93, 8 9, 7 89, Lmf Clima 6 87, 6 EFF% 4 83, 3 8, EFF% Performance 77, 7, 9, 7 89, 6 87, 8, EFF% 4 83, 3 7, 3 4 3 4 6 ) 4 6 ACCESSORIES PRESSURE DROPS 3 3 4 4 77, 4 79, 3 4 4 4 4 4 3 3 3 3 4 8, EFF% 3 6 8 8 93, 9, 9 RETURN 79, 43 8, 4 3 4 EFF 3 % % EFF 6 6 % EFF 4 6 9, 9, 88, 88, 86, 86, 84, 84, 8, 8, 8, 8, 78, 78, 6 76, 76, 74, 74, 8 8 9 9 7 8 9 7 8 9 7 7 HRH 8 9, 44 86, 3 3 4 4 6 3 8, 76, 74, 4 6 8 7 3 3 4 4 9 4 4 4 6 6 9, 6 4 6 7 78, 8 8 6 7 8, 84, 4 3 88, 6 7 8 88, 9, 86, 88, 84, 86, 8, 84, 8, 8, 78, 6 7 8 9 8, 6 7 8 9 76, 78, 74, EFFAir % flow rate (m3/h) 76, 7, 9 3 4 674, 6 7 8 9 6 4 3 4 3 4 4 6 HRH 6 7, 3 4 6 3 4 6 3 4 6 8 7 4 6 7 8 86, 9 84, 4 8, 3 8, 6 4 7 8 9 6 7 8 8 6 4 3 4 9 4 7 8 9 7 8 9 74, 6 76, 7, 6 6 8 4 6 78, 8 6 88, 4 9, 6 6 7 8 9 6 7 8 9 3 4 6 3 4 6 HRH 6

Lmf Clima 6 44 7 89, 6 7 87, 89, 8, 87, 6 4 77, 79, 7, 77, 3 4 6 7 8 9 7, 3 4 6 7 8 9 RETURN ACCESSORIES PRESSURE DROPS 7 89, 87, 8, 8, 79, 77, 4 6 4 9 7, 3 4 6 7 8 9 3 4 6 7 8 9 8 7 3 8 6 8 83, 6 4 79, 8, HRH 8, 83, 3 Performance 83, 8, 3 4 3 4 6 7 8 9 84, 83, 4 3 8, 86, 6 3 4 6 7 8 9 3 4 6 7 8 9 88, 87, 8, 8, 8, 79, 78, 77, 76, 7, 4 6 8 6 4 8 3 3 3 3 8 4 9 88, 87, 8, 6 8 7 3 4 6 7 8 9 84, 6 8, 8, 3 8, 79, 78, 4 6 3 8 77, 76, 4 6 7 4 8 6 9 8 3 7, 6 8 7 6 6 4 8 Air flow rate (m /h) 3 6 4 4 4 7 83, HRH 3 86, 8 6 4 6 8 3 4 3 4 3 6 4 8 3 Air flow rate (m /h) 3 87, 88, 8, 87, 86, 8, 84, 86, 83, 84, 8, 83, 8, 8, 8, 8, 79, 8, 78, 79, 3 77, 78, 76, 77, 7, 76, 44 7, 4 8 3 36 4 4 8 3 36 4 44 8 88, 6 86, 6 8 4 6 HRH 4 4 8 3 84, 3 83, 8, 8, 3 8, 79, 78, 77, 76, 4 4 6 8 8 3 36 4 Air flow rate (m3/h) 6 4 8 3 7, 44 3 8 6 4 4 8 3 36 4 44 4 8, 87, 4 8 6 8 4 6 4 4 8 3 36 4 44 4 8 3 36 4 44 76 88, 4 8 3 36 4 4 8 3 36 4 44 44

Lmf Clima 6 4 Noise levels The table lists the sound power values (SWL) in octave bands and als; it also indicates the values of sound pressure level (SPL) at m, m and m at supply, return and at the outside of the unit. All values refer to the operation of the ducted unit at FULL speed and at the nominal flow rate. SPL return SPL supply SPL external HRH SWL [db] OCTAVE BAND [HZ] SWL SPL SPL RETURN SPL OUTSIDE m m m m m m m m m 63 4 8 db db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) 6 9 6 6 63 63 6 3 7 69 6 47 4 3 39 33 44 3 4 6 8 64 64 6 6 6 3 7 68 6 47 4 3 39 33 44 3 4 6 9 6 6 63 63 63 7 7 6 48 4 4 4 3 4 3 66 64 74 73 69 68 68 67 79 76 68 4 48 6 46 4 37 3 3 69 66 74 76 7 7 67 67 8 77 69 49 6 47 4 38 3 4 68 69 7 73 69 7 66 6 79 76 68 4 48 6 46 4 37 3 Dimensions and weights HORIZONTAL VERSION HRH 3 4 L mm 3 47 8 8 W mm 68 8 3 46 46 84 H mm 33 37 4 4 9 9 W mm 76 9 4 4 9 X mm 3 3 39 6 9 78 Y mm 6 3 3 48 48 E mm,,,,,, F mm 46 46 46 46 G mm 8 3 8 7 7 7 D mm ½ M D mm ¾ M ¾ M ¾ M ¾ M M M L mm 3 4 4 4 L mm 34 38 46 46 8 8 Weight kg 8 7 3 9 36 E H Y E D D 4 4 F G F L L L W W VIEW FROM THE TOP

46 Lmf Clima 6 Dimensions and weights VERTICAL VERSION HRH 3 4 L mm 3 47 8 8 W mm 33 37 4 4 9 9 H mm 68 8 3 46 46 84 X mm 3 3 39 6 9 78 Y mm 6 3 3 48 48 E mm,,,,,, F mm 46 46 46 46 G mm 8 3 8 7 7 7 D mm ½ M D mm ¾ M ¾ M ¾ M ¾ M M M L mm 3 4 4 4 L mm 34 38 46 46 8 8 Weight kg 8 7 3 9 36 E Y E H D X G X F F D L D L W Configuration HORIZONTAL VERSION type A type B FRESH AIR EXHAUST VIEW FROM THE TOP (CDX) RETURN RETURN (CDX) VIEW FROM THE TOP FRESH AIR EXHAUST VERTICAL VERSION type C type D FRESH AIR RETURN RETURN FRESH AIR EXHAUST (CDX) (CDX) EXHAUST

Lmf Clima 6 47 Controls Automatic / manual speed selection EC fans management Manual ON/OFF Management of cold / change-over valve +V33 Management of hot valve +V33 -v control of direct expansion coil CDX Management of heat recouperator defrost Management of water coil anti-freeze device ON/OFF control of pre-heating battery Modulating control of pre-heating battery Management of free-cooling damper Management of filters differential pressure switch PSTD Management of ventilation with CO probe AQS Management of ventilation with pressure sensor DPS Management of ventilation with PIR occupancy detector Management of motorized dampers SKR+SSE Management of Boost by keyboard Alarms management Post ventilation Weekly programming Remote ON/OFF Fire alarm digital input Mode change (heating/cooling) from digital input Digital input for PIR occupancy Remote display with built-in sensor BMS Modbus protocol RS48 Reference diagram 8