Style 99 Roust-A-Bout Couplings

Similar documents
Lenntech Tel Fax

Vic-Strainer WARNING. System No. Submitted By Spec Sect Para Location Date Approved Date IPS CARBON STEEL PIPE - GROOVED ACCESSORIES SERIES 730

Series 706 Butterfly Valves (300 PSI/2065 kpa)

Series W706 AGS Butterfly Valves (300 PSI/2065 kpa)

Series 709 Butterfly Valves (175 psi/1270 kpa)

Series W709 AGS Butterfly Valves (175 psi/1270 kpa)

Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

Housing Coating: Orange enamel. Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

QuickVic Rigid Coupling for Steel. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE GROOVED COUPLINGS

B NPT. Dimensions Inches/millimeters

Series 751 FireLock European Alarm Check Valve Stations

SEE VICTAULIC PUBLICATION FOR DETAILS

Series 769 FireLock NXT Deluge Valve

Series 756 FireLock Dry System Check Valve

Series 758 FireLock Actuated System Valve

08.08 Vic-Check Valves

Couplings. Ductile Iron Housing Specifications. Coatings. Gasket Specifications. Bolt/Nut Specifications

Pressfit System for Carbon Steel Pipe

EMCO Corporation Waterworks is not responsible for any errors and discrepencies in the products depicted herein. Information is provided directly

Size Inches UL ULC FM. Pipe Sch.

Stainless Steel Pipe System. System No. Submitted By Spec Sect Para Location Date Approved Date TEMPERATURE ( F/ C)

Model 7706 Reducing Coupling. Deg. Axial Displacement

11.02 Mechanical-T Bolted Branch Outlets

REQUEST PUBLICATION 18.11

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Style Flange Adapter

Victaulic Suction Vibration Isolation Pump Drop Series 337 Korea Only

Product Submittals for Project

Style 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date

Victaulic Discharge CBV Vibration Isolation Pump Drop Series 383/383G

Vic -300 Butterfly Valves

General Price List Main effective MAY 13, General Price List. Main

FIG Gruvlok Flange Adapter

08.12 Vic-Plug Balancing Valve

VICTAULIC Shouldered Solutions

The applicable material specifications for ductile iron and rubber gaskets apply:

Model C10 / C11 / C20 / C60 Grooved Fitting For Copper Tubing Nominal Pipe Pipe C10 90 o Elbow C11 45 o Elbow C20 Tee C60 Cap

Fire Protection Price List. Piping. Systems. Solutions A FP.

GROOVED FITTINGS FOR COPPER TUBING

GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101

Vic -300 Butterfly Valves

Victaulic Standard Grooved and Advanced Grooved (AGS) Piping System for IPS Steel 2 (DN 50) through 60 (DN1500)

08.20 VIC -300 MasterSeal Butterfly Valves

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

STAINLESS STEEL SYSTEMS

Mechanical MATERIAL SPECIFICATIONS. Stainless Steel Housing Specifications. Gasket Specifications. Bolt / Nut Specifications

SJ-300N. Model SJ-300N-L Butterfly Valve with Lever Handle Max. Working Pressure (CWP)* PSI Bar Dimensions A B C D E in.

Victaulic Specification Power Industry

B U I L D I N G C O N N E C T I O N S T H AT L A S T

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

From the world s leader in mechanical piping systems... The complete system for stainless steel piping.

FIG Gruvlok Flanges

SJ-300N J-04. Model SJ-300N-L Butterfly Valve with Lever Handle

Grooved Piping System for Fire Protection Services

Typical Specifications Grooved Piping Method

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved Piping System for Fire Protection Services

Fire Protection Price List

Advantages of Grooved Fittings

Hole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole

INTRODUCTION. General Notes

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS


GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

COOPLOK Grooved Submittal. Material Specifications

Operators: Lever Handle: 1 1/2 3"/40 80 mm Carbon steel, zinc plated, plastic grip. 4 & 6"/100 & 150 mm Carbon steel, enamel paint

FIRE PROTECTION PRODUCTS

BULLETIN D NOVEMBER DeZURIK KSL-SD SLURRY KNIFE GATE VALVES TECHNICAL SPECIFICATIONS

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

24.01 Pipe Preparation Tool Specifications

*Applies to 6 x 4" No. 650 Reducer only. C to E. No No º Elbow Approx. Wgt. Each Lbs. kg. C to E Inches mm JOB/OWNER CONTRACTOR ENGINEER

Steel Fabricated Coupling

PARTS ORDERING INFORMATION

SUBMITTAL PACKAGE FIRE PROTECTION VALVES

Ford Service Saddles and Tapping Sleeves

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

Ford Service Saddles and Tapping Sleeves

Ford Fabricated Steel Products

INTEGRATED PIPING SYSTEMS. Technical manual. VSH Shurjoint

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

DeZURIK KSL-LA SLURRY KNIFE GATE VALVES TECHNICAL SPECIFICATIONS

Grinnell Grooved Fire Protection Products Grooved Fittings

American Flow control Series 2500

FITTINGS AND FABRICATIONS DESIGNED AND ENGINEERED HIGH DENSITY POLYETHYLENE PIPE

Mueller Super Centurion 250 Fire Hydrant

60.08 Style 233S Restrained Flexible Coupling For Dynamic Joint Deflection

Section 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings

Smith-Blair OMNI Coupling System Advantages:

Fire Protection Systems

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION

Butterfly Valves T5 (Wafer) and T6 (Lugged) Series

Grooved Piping Products

Section 18 Butterfly Valves

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

I-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS

030/TL 03/01 50M, Copyright 2001, Anvil International $3. 50

Ford Bolted Flex Couplings. Section M. 5/2008; Web Revision 10/2010

Transcription:

R IPS CARBON STEEL PIPE PLAIN END SYSTEM Style 99 Roust-A-Bout Couplings 14.02 VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION 1 1 / 2-12" Sizes 14-18" Sizes Style 99 Roust-A-Bout couplings are designed with heavy housings and grips to provide a strong component for joining plain and beveled end, including Schedule steel pipe and Victaulic plain end fittings. Roust-A-Bout couplings are not designed for use on plastic pipe, pipe with brittle linings, cast or ductile iron pipe nor any pipe with a surface hardness greater than 10 Brinell. Pipe is secured together by heavy jaws, which are set into the housing. The jaws provide a much greater gripping area than single spot grips. All sizes are supplied with painted housings and plated nuts and bolts. Galvanized housings are available. U L U L C See Victaulic publication.01 for details. WARNING Style 99 Roust-A-Bout couplings must be assembled with nuts tightened to full torque specifications. (Exaggerated for clarity) (Exaggerated for clarity) 1 1 / 2-18" Sizes 1"; 76,1 & 139,7 mm Sizes MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-36, grade 6-4-12. Ductile iron conforming to ASTM A-39, grade 6-4-1, is available upon special request. Housing Coating: Orange enamel. Optional: Hot dipped galvanized and others. Jaws: Carbon steel, case hardened, electroplated, except sizes 1"; 76,1 mm and 139,7 mm, which utilize stainless steel, Type 416, hardened. Gasket: (specify choice*) Grade E EPDM EPDM (Green color code). Temperature range F to +2 F ( 34 C to +1 C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86 F (+ C) and hot +1 F (+82 C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade T nitrile Nitrile (Orange color code). Temperature range 20 F to +1 F ( 29 C to +82 C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +10 F (+66 C) or for hot dry air over +1 F (+60 C). *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. s/nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. REGISTERED TRADEMARK OF VICTAULIC COPYRIGHT 200 VICTAULIC PRINTED IN U.S.A. SKU #WCAS- 6BER2 1671 REV. G United States Phone: 1-0-PICK-VIC (1-0-742-842) Fax: 6-20-8817 e-mail: pickvic@victaulic.com Canada Phone: 90-884-7444 Fax: 90-884-9774 e-mail: viccanada@victaulic.com Europe Phone: 32-9-381-100 Fax: 32-9-3-4438 e-mail: viceuro@victaulic.be UK Phone: 44(0)14387410 Fax: 44(0)1438313883 e-mail: viceuro@victaulic.be Central and South America Phone: 6-9-30 Fax: 6-9-3608 e-mail: vical@victaulic.com Australasia Phone: 86-21-8811 Fax: 86-21-881298 e-mail: vicap@victaulic.com

DIMENSIONS Y X 1-6" sizes Y X 8-12" sizes Y X 14-18" sizes Z Z Z Work Press. psi kpa Dimensions Inches/millimeters End Load Lbs.* N Required Lb. Ft.** N m /Nut No. - Size Inches X Y Z 1 1.31 600 0 3 2.6 4.2 2.2 1.7 2 33,7 41 360 47, 2-3 / 8 X 2 6 8 7 0,8 1 1 / 2 1.900 70 20 60 3.2.0 2.88 3.6 2-1 / 2 X 2 1 / 48,3 17 934 81,4 2 83 1 73 1,6 2 2.37 70 30 10 3.7 6.7 3.38.3 0 60,3 17 1468 203,4 2 - / 8 X 3 1 / 4 9 171 86 2,4 2 1 / 2 2.87 600 3890 10 4.2 7.13 3.38.7 2 - / 8 X 3 1 / 6 73,0 41 173 203,4 4 8 181 86 2, 76,1 mm Aprx. Weight Each Lbs. kg 3.000 0 282 9 4.69 6.2 2.7 4.4 76,1 2700 1200 128,8 2-1 / 2 X 2 3 / 4 119 19 70 2,0 3 3.00 600 770 200.00 8.0 3.38 8.7 88,9 41 2676 271,2 2-3 / 4 X 4 1 / 4 127 216 86 3,9 3 1 / 2 4.000 00 62 200.0 9.2 3.63.6 2-3 / 4 X 4 1 / 90 1,6 340 27946 271,2 4 1 23 92 4,8 4 4.00 40 71 200 6.13.00 4.00 12.8 0 114,3 318 271,2 2-3 / 4 X 4 1 / 4 16 24 2,8 139,7 mm.00 20 9 160 7..7 3.19 9.0 139,7 1700 264 217,0 2-3 / 4 X 200 260 81 4,1.63 0 20 7.2 11.38 4.38 17.3 12 141,3 20 3782 339,0 2-7 / 8 X 184 289 111 7,8 6 6.62 0 3 20 8.0 13.38 4.38 23.2 2-1 X 6 10 168,3 206 46013 339,0 216 3 111, 16,1 mm 6.00 0 99 20 8.38 13.2 4.38 22.2 2-1 X 6 16,1 206 440 339,0 213 337 111,1 8 8.62 20 14600 20.88 14.38.00 37.2 200 219,1 1700 64970 339,0 4-7 / 8 X 276 36 127 16,9.70 20 22700 0 13.38 16.38.00 48.2 20 273,0 1700 1 6,8 4-7 / 8 X 3 416 127 21,9 12 12.70 20 31900 1.0 19.63.13 60.0 0 323,9 1700 1419 474,6 4-1 X 6 1 / 2 394 499 1 27,2 14 14.000 200 0 16.7 20.7.38 89.0 3,6 10 137060 474,6 8-1 X 6 1 / 2 42 27 137,4 16 16.000 10 200 19.00 22.63.38.0 0 6,4 00 134390 474,6 8-1 X 6 1 / 2 483 7 137 47,6 18 18.000 10 38200 21.00 23.0.38 12.0 40 47,0 00 169990 474,6 8-1 X 6 1 / 2 33 97 137 6,7 * Working Pressure and are total, from all internal and external loads, based on coupling properly assembled, with bolts fully torqued to listed specifications, on plain end or beveled end standard weight (ANSI) steel pipe and Victaulic plain end fittings. Couplings are designed to be used with plain end pipe and Victaulic plain end fittings only. ** torque ratings shown must be applied at installation. Metric thread size bolts (plated) are available (color coded) for all coupling sizes upon request. Contact Victaulic for details. WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. 2 Style 99 Roust-A-Bout Couplings

Carbon Steel Pipe 1 2 1 1 / 2 2 0 2 1 / 2 6 3 3 1 / 2 90 4 0 12 1 2 3 4 6 Pipe Req d Working Pressure 1.31 33,7 1.900 48,3 2.37 60,3 2.87 73,0 3.00 88,9 4.000 1,6 4.00 114,3.63 141,3 Table continued on next page. 0.179 4, 0.133 600 0 3,38 3 41 360 0.9 47, 600 0 2,77 41 360 0.06 0 0 1,6 270 240 0.200 70 20,08 17 934 0.14 70 20 3,68 60 17 934 0.9 81,4 600 1700 2,77 41 76 0.06 0 10 1,6 270 489 0.218 70 30,4 17 1468 0.14 70 30 3,91 10 17 1468 0.9 203,4 0 10 2,77 270 0.06 200 900 1,6 137 0 0.276 600 3890 7,01 41 173 0.203 600 3890,16 10 41 173 203,4 0 1900 3,0 206 84 10 00 3 440 0.0 600 770 7,62 41 267 0.216 600 770,49 200 41 267 271,2 22 2160 3,0 10 96 12 1200 860 3 0.318 00 62 8,08 340 2794 0.226 00 62,74 200 340 2794 271,2 200 200 3,0 137 1112 0 120 690 6 0.337 40 71 8,6 318 0.237 40 71 6,02 200 318 271,2 17 20 3,0 1200 12460 60 90 41 42 0.37 0 9,3 24 3782 0.28 0 6, 20 24 3782 339,0 10 3600 3, 3 16020 0.9 7 10 2,77 1 Style 99 Roust-A-Bout Couplings 3

Carbon Steel Pipe 6 10 16,1 mm 8 200 20 12 0 1 2 3 4 6 Pipe Req d Working Pressure 6.62 168,3 6.00 16,1 8.62 219,1.70 273,0 12.70 323,9 0.432 0 3,97 206 4601 0.2 0 3 7,11 20 206 4601 339,0 0 0 3, 690 17 0.9 7 2600 2,77 1 1170 0.20 0 99 6,3 206 440 0.200 20 17 6000,08 339,0 1200 26700 0.10 0 0 3,81 690 17 0.322 20 14600 8,18 172 64970 0.277 200 11700 7,04 20 137 206 0.148 339,0 0 6000 3,76 690 26700 0.9 0 00 2,77 34 13 0.36 20 22700 9,27 172 1 0.7 17 1900 7, 0 1200 707 0.16 6,8 7 60 4,19 1 260 0 400 3, 34 2002 0.37 20 31900 STD 9,3 172 1419 0.3 10 190 8,38 3 8499 0.1 474,6 0 12700 4,7 690 61 0.16 7 900 4,19 1 4227 14 14.000 0.37 200 0 STD 3,6 9,3 474,6 137 137060 16 16.000 0.37 10 200 STD 0 6,4 9,3 474,6 3 134390 COLUMN 1: Victaulic couplings are identified by nominal pipe size. COLUMN 2: pipe wall thickness. COLUMN 3: Pipe wall thickness schedule as established in ANSI Standard B36, -70. COLUMN 4: torque required for installing Victaulic plain end couplings to achieve pressure ratings listed in Column and Permissible Maximum s listed in Column 6. TORQUE RATINGS MUST BE APPLIED AT INSTALLATION. COLUMN : Maximum line pressure, including surge, to which a joint should be subjected, based on couplings assembled to full torque specifications on plain end or beveled end standard weight steel pipe and/or Victaulic plain end fittings. Working pressure ratings are based on pipe prepared in accordance with Victaulic specifications. COLUMN 6: Maximum end load from all internal and/or external forces to which the joint should be subjected based on couplings assembled to full torque specifications. NOTE: Roust-A-Bout couplings, when sufficiently pressurized, will allow pipe to separate slightly as grips set into pipe. For properly assembled and torqued couplings, this separation should not exceed 1 / 4" (6,4 mm). This should be considered for installations in tightly confined areas. Style 99 couplings are not designed to provide linear or angular movement. ROUST-A-BOUT STYLE 99 COUPLINGS ARE DESIGNED FOR USE WITH PLAIN END OR BEVELED END PIPE AND VICTAULIC PLAIN END FITTINGS ONLY. 4 Style 99 Roust-A-Bout Couplings

Stainless Steel Pipe 1 33,4 1¹ ₂ 48,3 2 60,3 2¹ ₂ 73,0 3 88,9 3¹ ₂ 1,6 4 114,3 141,3 6 168,3 16,1 mm 8 219,1 1 2 3 4 6 Pipe Req d Working Pressure 1.31 33,7 1.900 48,3 2.37 60,3 2.87 73,0 3.00 88,9 4.000 1,6 4.00 114,3.63 141,3 6.62 168,3 6.00 16,1 8.62 219,1 0.133 3 600 0 3,38 47, 41 360 0.9 3 0 0 2,77 47, 270 240 0.06 3 20 1,6 47, 172 1 0.14 60 00 1,0 3,6 81,4 340 62 0.9 60 0 1,0 2,77 81,4 270 489 0.06 1,6 N/R N/R N/R 0.14 10 00 2,200 3,91 203,4 340 9790 0.9 10 0 1,0 2,77 203,4 270 0.06 1,6 N/R N/R N/R 0.203 10 0 2,00,16 203,4 270 1112 10 20 1,00,16 203,4 172 667 N/R N/R N/R 0.216 200 0 3,0,49 271,2 270 169 200 200 1,900 3,0 271,2 137 84 N/R N/R N/R 0.226 200 0 3,700,74 271,2 206 1646 200 10 1,900 3,0 271,2 3 84 N/R N/R N/R 0.237 200 20 3,900 6,02 271,2 172 173 200 1,0 3,0 271,2 0 78 N/R N/R N/R 0.28 20 200 4,0 6, 339,0 137 21360 20 7 1,0 3, 339,0 0.9 2,77 N/R N/R N/R 0.2 20 200 6,0 7,11 339,0 137 260 20 7 2,600 3, 339,0 1 1170 0.9 2,77 N/R N/R N/R 0.2 20 200 6,0 7,11 339,0 137 260 20 7 2,600 3, 339,0 1 1170 0.9 2,77 Table continued on following page. See notes on following page. N/R N/R N/R 0.322 20 200 11,000 8,18 339,0 137 4890 0.148 20 7 4,0 3,76 339,0 1 19 0.9 20 2 1,460 2,77 339,0 170 649 Style 99 Roust-A-Bout Couplings

Stainless Steel Pipe 273,0 12 323,9 1 2 3 4 6 Pipe Req d Working Pressure.70 273,0 12.70 323,9 0.36 0 0 9,000 9,27 6,8 690 00 0.16 0 0 4,00 4,19 6,8 34 2002 0 2 2,20 3, 6,8 170 0 0.6 0 12,70,31 474,6 690 673 0.1 0 6,0 4,67 474,6 34 284 0.16 2 3,200 3,96 474,6 170 142 NR = Not recommended + Contact Victaulic for details. COLUMN 1: Victaulic couplings are identified by nominal pipe size. COLUMN 2: pipe wall thickness. COLUMN 3: Pipe wall thickness schedule as established in ANSI Standard B36, -70. COLUMN 4: torque required for installing Victaulic plain end couplings to achieve pressure ratings listed in Column and Permissible Maximum s listed in Column 6. TORQUE RATINGS MUST BE APPLIED AT INSTALLATION. COLUMN : Maximum line pressure, including surge, to which a joint should be subjected, based on couplings assembled to full torque specifications on plain end or beveled end standard weight steel pipe and/or Victaulic plain end fittings. Working pressure ratings are based on pipe prepared in accordance with Victaulic specifications. COLUMN 6: Maximum end load from all internal and/or external forces to which the joint should be subjected based on couplings assembled to full torque specifications. NOTE: Roust-A-Bout couplings, when sufficiently pressurized, will allow pipe to separate slightly as grips set into pipe. For properly assembled and torqued couplings, this separation should not exceed ¹ ₄" (6,4 mm). This should be considered for installations in tightly confined areas. Style 99 couplings are not designed to provide linear or angular movement. ROUST-A-BOUT STYLE 99 COUPLINGS ARE DESIGNED FOR USE WITH PLAIN END OR BEVELED END PIPE AND VICTAULIC PLAIN END FITTINGS ONLY. 6 Style 99 Roust-A-Bout Couplings

Aluminum Pipe* 1 2 1 1 / 2 2 0 2 1 / 2 6 3 3 1 / 2 90 4 0 12 1 2 3 4 6 Pipe Req d Working Pressure 1.31 33,7 1.900 48,3 2.37 60,3 2.87 73,0 3.00 88,9 4.000 1,6 4.00 114,3.63 141,3 0.179 4, N/R N/R N/R 0.133 3 600 0 3,38 47, 41 360 0.9 3 0 0 2,77 47, 206 17 0.06 3 0 13 1,6 47, 690 601 0.200 60 00 10,08 81,4 340 62 0.14 60 0 10 3,6 81,4 2760 489 0.9 60 0 82 2,77 81,4 206 3671 0.06 1,6 N/R N/R N/R 0.218 10 0 10,4 203,4 2760 0.14 10 0 10 3,91 203,4 206 78 0.9 10 200 900 2,77 203,4 13 0 0.06 1,6 N/R N/R N/R 0.276 10 2200 7,01 203,4 241 9790 0.203 10 27 172,16 203,4 189 7676 10 10 00,16 203,4 3 440 N/R N/R N/R 0.0 200 0 28 7,62 271,2 206 12816 0.216 200 200 1920,49 271,2 13 844 200 0 960 3,0 271,2 690 4272 N/R N/R N/R 0.318 200 20 8,08 271,2 172 1379 0.226 200 200 200,74 271,2 13 1112 200 0 120 3,0 271,2 690 63 N/R N/R N/R 0.337 200 200 3200 8,6 271,2 13 142 0.237 200 10 20 6,02 271,2 3 6 200 0 0 3,0 271,2 34 360 N/R N/R N/R 0.37 20 10 3600 9,3 339,0 3 16020 0.28 20 0 20 6, 339,0 690 6 20 0 1200 3, 339,0 34 3 0.9 2,77 Table continued on following page. See notes on following page. N/R N/R N/R Style 99 Roust-A-Bout Couplings 7

Aluminum Pipe* 6 10 8 200 20 12 0 1 2 3 4 6 Pipe Req d Working Pressure 6.62 168,3 8.62 219,1.70 273,0 12.70 323,9 0.432 20 10 200,97 339,0 3 231 0.2 20 0 0 7,11 339,0 690 17 20 0 170 3, 339,0 34 7788 0.9 20 3 122 2,77 339,0 2 41 0.322 20 10 9000 8,18 339,0 3 00 0.277 20 0 6000 7,04 339,0 690 26700 0.20 20 7 400 20 6,3 339,0 1 2002 0.148 20 0 00 3,76 339,0 34 13 0.36 0 0 9000 9,27 6,8 690 00 0.7 0 7 60 7, 6,8 1 23 0.20 0 0 400 20 6,3 6,8 34 2002 0.16 0 2 220 4,19 6,8 172 013 0.6 0 0 120,31 6,8 690 6960 0.3 0 7 900 8,38 6,8 1 4227 0.20 0 0 6000 20 6,3 6,8 34 26700 0.1 0 2 310 4,67 6,8 172 118 * Aluminum Pipe Alloy 6063-T6 or 6061-T6 in Schedule and ; Alloy 6063-T6 in Schedule, 20, and. NR = Not recommended COLUMN 1: Victaulic couplings are identified by nominal pipe size. COLUMN 2: pipe wall thickness. COLUMN 3: Pipe wall thickness schedule as established in ANSI Standard B36, -70. COLUMN 4: torque required for installing Victaulic plain end couplings to achieve pressure ratings listed in Column and Permissible Maximum s listed in Column 6. TORQUE RATINGS MUST BE APPLIED AT INSTALLATION. COLUMN : Maximum line pressure, including surge, to which a joint should be subjected, based on couplings assembled to full torque specifications on plain end or beveled end standard weight steel pipe and/or Victaulic plain end fittings. Working pressure ratings are based on pipe prepared in accordance with Victaulic specifications. COLUMN 6: Maximum end load from all internal and/or external forces to which the joint should be subjected based on couplings assembled to full torque specifications. NOTE: Roust-A-Bout couplings, when sufficiently pressurized, will allow pipe to separate slightly as grips set into pipe. For properly assembled and torqued couplings, this separation should not exceed 1 / 4" (6,4 mm). This should be considered for installations in tightly confined areas. Style 99 couplings are not designed to provide linear or angular movement. ROUST-A-BOUT STYLE 99 COUPLINGS ARE DESIGNED FOR USE WITH PLAIN END OR BEVELED END PIPE AND VICTAULIC PLAIN END FITTINGS ONLY. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 8 Style 99 Roust-A-Bout Couplings