DRIVE THE WATER CYCLE. January 10 TH 2013

Similar documents
SOLAR PUMPING March 7 th 2013

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Variable Speed Drives Controlling Centrifugal Pumps Energy Savings

Hydrovar and Packaged Hydrovar

Variable Speed Product Line

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Starts, stops and protects. Emotron TSA Softstarter

RVS-AX Instruction Manual

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Steve Schouten. Donna Densmore

Table of Contents. Foreword...xiii. Chapter One Introduction, Objectives of the Guide...1

VASCO. Variable Speed Controller ENGLISH

SOLSTART Instruction Manual

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

CTi Automation - Phone: Fax: Web:

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

ABB Softstarter Benefits Charnchanok Thongprad

Variable Frequency Drives

Your choice for wall and panel mounted AC drives. Emotron FDU & Emotron VFX IP20/21 up to 160 kw

Delta Products VFD CP2000 Bypass Control Packages.

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

Question Number: 1. (a)

Design Guide. VLT Soft Start Controller MCD 100

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Variable Speed Pumping

Master Plus kva

Uptime. All the time.

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Technical Data Sheets

Technical Data Sheets

PumpSmart. Control Solutions

Softstarters Softstarters

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Reduced Voltage Motor Starters

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Green Power 2.0 MASTERYS GP

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors

Proudly 100% Australian Owned Manufacturers & Distributors of Variable Speed Drives & Soft Starters ECODRIVE Solar Variable Speed Drive

CT430 - Soft Starters on Motor Applications

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

MGE TM Galaxy TM 7000 GFC

Application Description

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

PPC3 & PPC5. State-of-the-art pump protection and controllers

Company name: Čerpadla NEPTUN Created by: Václav König Phone: Date:

When to use a Soft Starter or an AC Variable Frequency Drive

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Variable Frequency Drive Basics

Integration of Large Wind Farms into Electric Grids

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Controls. CONTACTORS CWB Line (up to 40A)

FUSES. Safety through quality

AF40... AF96 3-pole contactors Technical data

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

INGECON SUN PowerMax B SERIES. A new generation of central photovoltaic inverters

POWERBOOST. PRO Range. Clean Water Booster Sets. powerboost.ie

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

Application Note CTAN #127

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Pump ED 101. Variable, Fixed Speed Control - - Float Switch Activation. Introduction

Solar Pumps- High profitability and reliability lead to prosperity.

Experience and History

MGE TM Galaxy TM 7000

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Product brochure. Medium voltage AC drive ACS 1000, ACS 1000i 315 kw 5 MW, kv

lubrication systems CME Electric pump for oil and soft grease volumetric

SSW07. Soft Starters. Applications. Standard Features

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

MASTERYS IP+ 10 to 80 kva

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

A softstarter beyond the ordinary

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller

You have probably noticed that there are several camps

Short form catalogue. Motor protection & control

Advanced Variable Torque Application Training Eaton Corporation. All rights reserved.

MODVAR Low voltage reactive power compensation modules Installation manual

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Power Solutions Manager Generac Power Systems, Inc.

American Traction Systems. DC Bus Capacitorss. Total. Dual Chopper Module. Dual. Inverter. 750kW. 750kW Generator Module. Module

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

Technical Data Sheets

Parallel coupled APP pumps

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Technical Data Sheets

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

AIR CORE REACTORS. Phoenix Electric Corporation

4-Day Power System Analysis, Coordination, System Studies

Transcription:

DRIVE THE WATER CYCLE January 10 TH 2013

DRIVE THE WATER CYCLE

EXTENDED FLOW CONTROLS Throttling control Bypass control Parallel Pump control VSD control

THROTTLING CONTROL The operation point is modified by closing the line valve. This effect increases the hydraulic losses and reduces pump s efficiency. Therefore, depending on the pump s construction, it doesn t provide any energy savings.

BYPASS CONTROL A parallel circuit equipped with a line valve guides part of the flow back to the suction line. By opening and closing the bypass valve, the system is able to Control the delivered flow to the system. Consequently, the pump s flow and efficiency are increased and head is reduced. Occasionally, the pump could deliver a high flow even though the system is completely cut off.

PARALLEL PUMPS CONTROL In systems with a wide flow range, it can be an advantage to use a number of smaller parallel-connected pumps instead of one larger pump equipped with flow regulation. The centralized control will start and stop the pumps in order to satisfy the flow demand. A combination of variable speed drives and soft starters could be the most efficient solution.

VSD CONTROL - BENEFITS In general terms, throttling control or bypass system are energy inefficient solutions and should be avoided. The efficient alternative is the variable speed control. ENERGY SAVINGS: An smart flow control with VSD s can lead into high energy savings in comparison with traditional flow control systems QUALITY AND PERFORMANCE IMPROVEMENT: Introducing a pressure, flow or level PID control increase the process performance. REDUCE MAINTENANCE AND INCREASE MOTOR LIFE TIME: The high number of starts and the overcurrent suffered by induction motors reduce its working lifetime and increases their maintenance costs. DECREASE THE ENVIRONMENTAL IMPACT AND IMPROVE THE CORPORATIVE IMAGE: The reduction of the electricity, Natural gas or diesel consumption leads into a reduction of the company s greenhouse gases emission.

VSD CONTROL The variable speed pump s control provides unique regulation and performance features. The variable speed drive modifies the performance curve of the pump in order to meet the system requirements. The centrifugal pump performance is modeled by the affinity laws. In theory, the power reduction is proportional to the cubic of speed, for example a 20% speed reduction cause a power saving greater than 47%.

THROTHLING CONTROL VS VARIABLE SPEED DRIVE - OVERVIEW 80 70 P = 50 100kW 40 3 P40 = P50 = 51. 2kW 50 Head in m H 2 O 1 X n FLOW 80 70 35 P35 P = 50 = 34.3kW 50 Head in m H 2 O 1 X n 3 60 50 40 30 0.9 X n 0.8 X n 0.7 X n 0.6 X n Static height 20 meters 100% 80% 70% 90% 60% 50% 60 50 40 30 0.9 X n 0.8 X n 0.7 X n 0.6 X n 20 0.5 X n 0.4 X n 20 0.5 X n 0.4 X n 10 H-Q curves 10 0 10 20 30 Q Flow 50% 100% m 3 /min H-Q Curves System curves 0 10 20 30 50% 100%

PUMP S CURVE DEFINE ENERGY SAVINGS Head (bar) 50 Hz 40 Hz 30 Hz CURVE A Head (bar) Min. Head 50 Hz 40 Hz 30 Hz CURVE B 20 Hz Min. Head High slope curves have good regulation range Better regulation means higher energy savings Q (m 3 ) Q (m 3 ) Flat pump curves leads into a bad regulation by speed variation Energy savings are limited due to a tight regulation range PP 2 = PP 1 20 50 3 = PP 1 0.064 PP 2 = PP 1 40 50 3 = PP 1 0.512

PUMP S EFFICIENCY VARIATION DEPENDING ON SPEED VARIATION 80 1 X n 30% N = 1480 50% 60% RPM 70% 70 80% 85% 60 50 40 0.9 X n 0.8 X n 0.7 X n 87% 88% 87% 85% 80% 30 0.6 X n 20 10 0 0.5 X n 0.4 X n 10 20 30 40 Efficiency curves Curve H Q System curve Q flow m 3 /min

AHORRO ENERGÉTICO - OVERVIEW POWER (%) A: Power reduction by using VSD. B: Power reduction by using Slide Valve FLOW (%)

ENERGY SAVINGS - OVERVIEW Flow (%) Valve control Power ( kw) Power Demand with SD700 VFD (kw) Power Reduction (kw) Energy saving (%) Cost saving ( /1000 h) 100% 100 100 - - - 90% 95 72,9 22,1 23 % 3.315 80% 83 51,2 31,8 38 % 4.770 70% 77 34,3 42,7 55 % 6.405 60% 73 21,6 51,4 70 % 7.710 50% 68 12,5 55,5 81 % 8.325 Pump Power : 110 kw Electric cost: 150 /MWh

VARIABLE SPEED DRIVES BENEFITS IN PUMPING SYSTEM Energy Saving by adjustable Head and Flow. Soft start and inrush current control by implementing a ramp setting. Water hammer control and soft stop High power factor >0.98, no capacitor banks need Automatic re-start after voltage dips or shutdowns

SD700 BENEFITS IN PUMPING SYSTEMS Low dv/dt - No special motor cable and suitable for long motor cable distances IP54 without dust filters Full Frontal Access maintenance friendly Totally sealed and varnished electronics 50ºC operation without Power Derating Low Harmonics Built-in Input Chokes Voltage sag tolerance ±10%, -20% VRT. Motor Temperature monitoring by PTC or PT100 Solar back-up kit availability SD700 SPK

SD700 PROTECTIONS IGBT s overload Input phase loss Low input voltage, High input voltage DC Bus voltage limit, Low DC Bus voltage High input frequency, Low input frequency IGBT temperature, Heatsink over-temperature Drive thermal model Power supply fault Ground fault Software and Hardware fault Analogue input signal loss (speed reference loss) Safe Torque Off

SD700 MOTOR PROTECTIONS Rotor locked Motor overload (thermal model) Motor Underload Current limit Maximum Starts Phase current imbalance Phase voltage imbalance Motor over-temperature (PTC signal), PT100 Optional Speed limit Torque limit.

SD700 PUMP PROTECTIONS AND FEATURES Hammer control Back spinning soft start and stop Pipeline filling function Jockey and Priming pump control Minimum speed to assure pump s cooling Pump cavitation Pump clogging Overpressure or underpressure monitoring PID direct and reverse regulation ( flow, pressure, level, ) Sleep and wake up functions PLC shutdown Timers and irrigation program

PUMPING SYSTEM CONTROL WITH VSD PRESSURE CONTROL FLOW CONTROL - DOSING LEVEL CONTROL RESERVOIR PUMPING MULTI REFERENCE MULTI MASTER CONTROL MULTI PUMP SD700 + V5 MULTI PUMP CONTROL

PRESSURE CONTROL The pressure signal is sent by a pressure transducer to an analogue input of the drive. The PID control adjust the speed reference and flow to keep a constant pressure upstream. Applications: Fresh water distribution systems. Step Irrigation, Pivot irrigation

FLOW CONTROL- DOSING The flow signal that comes from a pulse flow meter is sent to the SD700 analogue input. The PID control adjust the speed reference of the controlled pump according to the configured settings. Applications: Dosing

LEVEL CONTROL- DOSING The water level that comes from a level indicator is sent to the SD700 analogue input. The direct or reverse PID control adjust the speed reference of the controlled pump in order to assure the established level. Applications: Submergible well pump, pond level control, reservoir control.

MULTI REFERENCE The drive can be commanded with up to 9 different pressure reference signals by combining the status of three digital inputs. Applications: Step irrigation networks, Pivot irrigation

MULTI MASTER CONTROL When the PLC that manage the system shuts down, the SD700 can control up to 6 pumps in an automatic master-slave system that starts, stops and adapt the slave s speed to the demand. This system provide full redundancy and reliability to your facilities. Applications: Multi pump control and stations.

MULTI PUMP CONTROL SD700 + V5 SD700 acts as a master carrying out a pressure PID control and sending the start and stop commands to the V5 soft starters depending on the downstream water demand. This solution protects every single motor and increase the availability. Being able to run even if the master shuts down. Applications: Fresh water distribution systems

MULTI PUMP CONTROL A single SD700 can control up to 6 pumps depending on the downstream pressure. It smoothly start and stop the pump and when it reaches the full speed the drive disconnect the line contactor and connects the bypass contactor. When the pump is bypassed the line fuse will protect it. Applications: Fresh water distribution system with small pumps.

SUBMERSIBLE PUMPS ANNEX

SUBMERSIBLE PUMP TOPOLOGY Water impulsion Pump Impellers Pump Shaft Cooling jacket Water intake Motor Shell Motor Thrust bearing

SUBMERSIBLE PUMPS & VSD CONSIDERATIONS MOTOR CABLES TYPE AND LENGHT PUMP COOLING THRUST BEARING COOLING VSD OPERATION & SETTINGS

SD700 RECOMMENDED CABLE TYPE Desired - Up to 300m Compatible - Up to 150m

VOLTAGE FLANGE WAVE FORM ALL DRIVES ARE NOT THE SAME Competitors dv/dt values SD700 STANDARD

ADMISSIBLE PEAK VOLTAGE LIMIT CURVES IN AC MOTORS TERMINALS: Peak voltage (kv) 2.4 2.0 1.6 1.2 20m 30m 50m 100m IEC 60034-25 Curve B (without filters for motors up to 690V AC) NEMA MG1 Pt31 in grids of 600V IEC 60034-25 Curve A (without filters for motors up to 500V AC) 200m IEC 60034-17 NEMA MG1 Pt31 in grids of 400V 2.15kV 1.86kV 1.56kV 1.35kV 1.24kV 0.8 10m 0.4 Examples of the test results, SD700 using reinforced copper wires at 415V rated voltage. 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Rise time of the voltage pulse (µs)

Well intake Cooling Speed - V (m/s) Q (m3/s) T (ºC) PUMP COOLING Keep a minimum speed of the surrounding water. Vc = 0.08 0.5 m/s ( Consult Manufacturer) Cooling flow depends on: Water temperature and properties Pumps geometry and Motor Shell Motor and pump load Well geometry INCREASE COOLING CAPACITY REDUCE HEAT LOSSES Lower water temperature (ºC) Higher pump flow (Q) Lower motor load (AP) Pump speed reduction (Hz) Wider motor Diameter (mm) Dp Dw Higher convection factor (W/mm 2 ) Water stream distribution Low factor between motor diameter and well diameter

THRUST BEARING COOLING Thrust bearings needs a minimum water flow (15-30% of Qn) to create a thin lubrication layer. The layer ensures bearing cooling and reduce friction between fixed parts. Lubrication layer

VSD OPERATION AND SETTINGS YES Is there water release holes in the pump? YES How long it takes to empty the pipe? - Soft start after the empty time - Soft stop to reduce water hammer NO Start and Stop with waterfilled pipe settings (Maximum head)- CASE 1 1 Is a Check Valve integrated in the pump? YES Start with empty pipe but it needs a fast speed transient - CASE 3 3 NO Is there a check valve on the top of the hole? NO Soft start and stop CASE 2 2

START AND STOP WITH WATER-FILLED PIPE 1 Head (bar) Min Head 50Hz Min Head - AP Q min (thrust bearing cooling) Pump Installation 10Hz 40Hz 30Hz 20Hz Q (m 3 ) Pump Speed (Hz) 50 40 30 20 10 0 Slow ramp - Flow control range - Reduce sand impulsion 2s Fast ramp Min Flow 4s- 7200s 30s Slow ramp Water Hammer Control 1s Fast ramp Pump stop Time (s)

SOFT START AND STOP 2 Head (bar) Min Head 50Hz Min Head - AP Q min (thrust bearing cooling) Pump Installation 10Hz 40Hz 30Hz 20Hz Q (m 3 ) Fast ramp Min Flow Pump Speed (Hz) 50 40 30 20 10 0 1s Slow ramp - Flow control range - Reduce sand impulsion 4s- 7200s Slow ramp Water Hammer Control 4s- 7200s 1s Time (s)

SOFT START AND STOP WITH FAST TRANSIENT Head (bar) 3 Inst. Head Min Head - AP Fast ramp Min. Flow Min Head Pump Speed (Hz) 50 40 30 20 10 0 Q min (thrust bearing cooling) Pump Installation 50Hz 40Hz 30Hz 20Hz 10Hz Q (m 3 ) Slow ramp - Flow control range - Reduce sand impulsion Slow ramp Water Hammer Control 1s 4s- 7200s 1s Fast transient ramp Checkvalve opening 4s- 7200s 4s- 7200s 1s Time (s)

CASE STUDY WELL LEVEL VARIATION SUMMER 39 WINTER

HYDRAULIC POWER EQUATION POWER (W) = r x g x H x Q x ŋ -1 r = Density (kg/m³) g = Gravity (9.81m/s²) H = Head (m) Q = Flow (m³/s) ŋ = Efficiency 40

POWER ELECTRONICS appreciate your attention More info: www.power-electronics.com