General Installation Instructions for Valves and Gates

Similar documents
MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

CSA products for waste water. Combination air valve. Mod. SCF 2

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

CSA products for treated water. Water Combination air valve. Mod. FOX 3F RFP and Lynx 3F RFP

LESTRONIC II BATTERY CHARGER MODEL 19740

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

CSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Installation, Operation and Maintenance Manual

NECO Pumping Systems

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

Rechargeable Inflator

INSTALLATION & OPERATION MANUAL

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Push-Pull Slide Gate - Series E

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

FIGURE 310A & 311A 3-PIECE BALL VALVE

CRD610 Automatic Fitting Inserter

Slide Gates INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. 295-E-002 Effective

Installation, Operation, and Maintenance Instructions

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

TCM D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company

COMPRESSED AIR LOADER MODEL: AL-1

A39 UNIVERSAL SCR CHARGER

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Instruction Manual. Fudge Puppy Display Case

CLEAN POWER TM CPS Series Operator s Manual

BCFS Belt Driven Centrifugal Filtered Supply Fans

LIGHTNING PROTECTION UNIT (LPU)

COLT CELL BATTERY CHARGER Installation and Operating Instructions

TITAN FLOW CONTROL, INC.

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

OPERATIONS MANUAL LEVER CHAIN HOIST

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

A48 / A48B (base plate) BATTERY CHARGER

INSTALLATION & OWNER'S MANUAL

INSTALLATION AND OPERATION MANUAL Low Profile Long Frame Floor Jack Model: RFJ-3000LPF REV B

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

INSTRUCTION MANUAL FOR PC63 CAGE

INSTALLATION & OPERATION MANUAL

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

3V SERIES SOLENOID VALVE

QPET, QPETXU Battery Chargers

Operator s Safety and Service Manual

DC to AC Power Inverters

DC to AC Power Inverters

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

Integrated Heating System

BP1204 INSTALLATION/OWNER'S MANUAL

6. Electrical. 7. Settings. 8. Quick

The RICON S-Series Personal Use Wheelchair Lift provides wheelchair access to personal

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

NOTE. Installation and Service Manual Dual Planetary Gearmotor Slim Rack Slide Out System

OBAE, OBAEXU, ON BOARD Battery Chargers

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

BMRX Series ROTARY LEVEL CONTROL

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Water Jetter Units DU JT50 / DU JT100

Air Curtain. Installation, Operating and Maintenance Instructions

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

INSTALLATION GUIDE. Universal System for Zero Turn Mowers

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Aug 24, 2017 ATS AFX Spindle Installation Instructions

INSTALLATION & OPERATION MANUAL

Operating and Installation Instructions

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

Owners Manual: - Pumps

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

Chicane Coilover Kit For '70 to '81 Camaro/Firebird

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

Installation Manual for Ecology

Item no Smart AC 200 USB. User s Manual

Transcription:

General Installation Instructions for Valves and Gates Thank you for your purchase of a Lorenz valve. We appreciate your business! Please read this installation manual and follow recommended safety precautions. Read thoroughly and contact Lorenz if you have any questions. Canada 1-800-263-1942 USA 1-800-263-7782 IMPORTANT DISCONNECT & DE-ENERGIZE ALL ELECTRICAL AND COMPRESSED AIR CONNECTIONS TO ANY VALVE PRIOR TO INSTALLATION OR SERVICE Caution: Please follow your prescribed safety policy during installation. Use extreme caution when handling these valves. Do not energize until all proper installation steps have been completed and all guarding is in place. Lock out all sources of energy & air before servicing or inspection and during installation. SAFETY Before attempting installation or before connecting electricity or air supply, please review and familiarize yourself with the operation of the Lorenz valve or gate. Be aware of any sliding blades and moving parts which could cause injury if the valve or gate is handled incorrectly. Keep all body parts clear of these potential hazard areas. Before actuating, ensure all personnel and equipment are clear of any moving parts. Pay attention to any warning labels on the valve or gate. Do not operate without all supplied guarding in place. Keep hands clear of any moving parts. Please contact Lorenz if you have any questions regarding the safe handling and installation of your valve or gate. UNPACKING AND INSPECTION Please carefully examine the box or crate for damage by the carrier during shipping. Immediately report any damage or missing boxes/ crates to the delivering carrier. Lorenz is not responsible for damages caused in transit, but can assist you in launching a claim with the carrier. Please notify Lorenz immediately of any damages or shortages. STORAGE AND HANDLING All valves should be stored in an enclosed, clean, dry area, free from excess humidity temperatures or moisture. All valves should be stored with all openings covered to prevent foreign matter from entering the valve including all solenoids and electrical connections and compressed air lines. ELECTRICAL REQUIREMENTS Please ensure all electrical connections are to local codes and done by qualified personnel. An electrical disconnect box must be provided for electrical actuators with a mechanical lock out in the off position. Valves and Gates equipped with Solenoid Valves and Limit Switches will require power supply. Please check Solenoid Valve and Limit Switch specification in Appendix for requirements. 1

MECHANICAL CONNECTIONS AND MOUNTING Flange Connections Check to make sure flange bolt holes line up and that the sizes match. Ensure mating flange is clear of old sealing/ gasket material, corrosion and other debris. Mating flanges should be flat and straight. Do not drill into flange on valve as this can damage the valve and will void the warranty. Use grade 5 bolts & nuts or better along with washers and lock nuts to make the connection. Do not over-tighten nuts (NOTE: BBH (Blind Bolt Hole) connections Do not bottom out the bolt into the valve as this will damage the valve and void the warranty. Please take into consideration flange thickness complete with washers and gaskets when determining bolt length. Flange gaskets should be used with BBH and SB flange options. With compression coupling connections, valves must be supported on either side. Allow for expansion or contraction of conveying line as well. Support Requirements All incoming / outgoing conveying lines must be supported as per local codes. All valves must be properly supported prevent binding and damage (See appropriate section below). Failure to support any valves or the conveying lines will void the warranty. Avoid supporting conveying lines or other equipment other than factory supplied accessories from the valve or gate body. Valves and Gates should only be lifted from the main body. Do not lift valves from the actuator as this could damage the actuator. Lorenz is not responsible for any damage caused by improper lifting during unpacking and installation. Valves or Gates with Electrical Actuators may require additional support due to the weight of the Electrical Actuator. Slide Gates, Diverter Gates, Aggregate Gates, Slide Flex Gates, Roller Gates Mounting It is important to ensure that the gate body and actuator are properly supported to maintain an accurate alignment of the actuator and mechanism for proper operation of the gate. Sealed/Unsealed Gravity Diverters, Aggregate Diverters Mounting These valves generally are supported by the flange or tube connections and do not generally require additional support for the actuator to ensure correct operation. Larger size diverters may require additional structural support and must be provided for before installation. Please ensure connecting lines and equipment is supported as per local code and is sufficient to carry the weight of the Diverter. PNEUMATIC REQUIREMENTS A vented ball valve should be installed within 12 of air cylinder as an Air Supply Shut off. Vented ball valves allow the air pressure to escape from air cylinder preventing un-expected closure. (Regular ball valves trap the air in and are not recommended) Compressed air lines should be at least the same inside diameter as the ports on the factory supplied air control valve to provide the proper valve actuation. Factory supplied air controls are sized for proper valve performance. Inadequately sized controls will affect performance of the valve. There must be a minimum of 80 PSIG compressed air pressure at the air cylinder to ensure proper operation. Maximum air pressure is 150 PSIG. Clean and dry compressed air is required to insure proper operation of the air cylinder. High moisture at low temperatures can cause the air control valves and the air cylinder to freeze. 2

All valves with Air Purge feature must be set at 1-2 PSIG greater than the conveying pressure (15 psig maximum) to create a positive pressure within the valve body. Air purge pressure can be adjusted by pressure regulator installed on the valve. System Differential Pressure The pressure differential ratings for Lorenz valves are: 1) Roller Gates, Maintenance Gates, Aggregate Gates, Gravity Diverters and Aggregate Diverters are limited to applications which contain NO Air Pressure 2) Diverter Valves, Slide Gates, Slide Flex, Discharge Valve is limited to application under 15 psig Warranty is void if valve is operated beyond rated limits. Please consult technical support for information. ENVIRONMENT All valves are designed for use in most indoor applications. Valves with electric and/or air controls that are subject to wash down conditions should be protected as per local codes. Do not wash down any valve with gate in the closed position as it could affect the performance of the valves and seals. Do not use any harsh or caustic solutions during wash down as they could damage the seals and affect the performance of the valve. Valves equipped with washdown capable components can be washed down with gate in the open position and water temperature should not exceed 82C (180F). Use of valve in environments exceeding the specified temperature rating will damage the seals and void the warranty. Do not weld or use open flame on or near the valve. The seals will be damaged and void the warranty. For proper operation of the valve air controls, switches and valve should be protected from rain and snow. A protective weather shield is recommended. Moisture & high humidity can damage the valve by causing the seals to swell; a wash down modification is required for any valve in this situation. 3

WIRING DIAGRAMS Single Solenoid (2 Way Diverter, Slide Gates, Roller Gates, Gravity Diverters, 2 Way Slide Flex) Single Solenoid (3&4 Way Diverters) Double Solenoid (2 Way Diverter, Slide Gates, Roller Gates, Gravity Diverters, 2 Way Slide Flex) Double Solenoid (3 & 4 Way Diverters) 4

POSITION SWITCHES SW-R-004 SW-RX-001 Description Reed Switch, MOV, LED Light, 2 Wire Reed Switch, MOV, LED, 3 Wire Function Normally Open SPST Normally Open TRIAC output Switching Voltage 5 240 VDC/VAC 50/60 Hz 24 240 VAC 50/60 Hz Switching Current 1 Amp Max,.005 Amp Min 4 Amp Max, 50 Amp Inrush,.005Amp Min Switching Power 30 watts Max. 100 watts Max. Switch Speed 0.6ms operate, 0.05ms release 0.6ms operate, 0.05ms release Voltage Drop 3 volts 1 volt Temperature Range -20 C to +80 C (-4 F to + 176 F) -20 C to +80 C (-4 F to + 176 F) Lead Length 9 feet 9 feet Usage notes For PLC Application Will light control panel Wiring Diagram A Red A Red B Black B Black Note: Usage above maximum ratings or incorrect wiring connections will result in damage to switch. C White 5

POSITION SWITCH TROUBLE SHOOTING NOTES Problem Solution Reed Switch works but LED does not light 1. Check current draw of load. It must be > 5 ma for LED to light. 2. 2. Check polarity: Refer to wiring diagram if using DC power supply Reed switch sticks in closed position. 1. Check current draw, power/va and voltage of load and compare with specs of the appropriate model sensor. These cannot be exceeded. 2. Voltage/Current spikes may be excessive for your particular load. External transient suppression may be required. 3. Long wire runs (greater than 25') can cause capacitance build-up and sticking will result. Consult factory for solution. Current or voltage leakage when reed switch is off. 1. Check current, power/va and voltage rating of load and compare with specs of appropriate model sensor. Those cannot be exceeded. 2. Reed element was damaged. Consult factory. Reed switch will not turn on. 1. Check magnet strength on surface of sensor. It must be >85 Gauss. 2. Switch is damaged. Consult factory. 3. 3. Check for proper wiring. Reed switch turns on more than once as magnet passes beneath it. 1. Check for proper magnet polarity. The poles must be parallel to the switch as shown in the wiring diagram. 2. Check for dead spots on the magnet if polarity is correct. 6

WARRANTY Any modifications to any valve other than recommended maintenance voids the warranty. Please contact Lorenz if you have any questions regarding maintenance or troubleshooting and before attempting any repairs. Lorenz warrants to the original buyer only that all products or parts sold by Lorenz shall be free of defects in materials and workmanship for a period of one (1) year from the date of shipment, when used according to Lorenz recommended usages. This warranty is strictly limited to repair or replacement of defective parts, provided those products are returned to Lorenz prepaid. Labour and materials for any downtime/repair/replacement is not covered. This warranty shall be considered void if such products are misused, improperly installed, improperly stored, operated beyond rate limitations, damaged, neglected, altered/changed/repaired or modified by anyone other than Lorenz or designate. Lorenz assumes no responsibility for any emissions from our valves. All special order products or material are not returnable. No liability is assumed for consequential damages or for any labour or other expense incurred by reason of sale or use of our products, singularly or in combination with other products. To the best of our ability products will be delivered at specific times but no liability is assumed for failure to deliver because of delays or defaults occasioned directly or indirectly by fire, flood, act of God, labour trouble or shortage or any cause unavoidable beyond our reasonable contract. Goods remain the property of the seller until payment is received in full and purchaser acknowledges in full that this is a security agreement and a document to this effect may be registered according to the local and applicable legislation or there shall be a charge for the full purchase price on the goods. All special order products or material are not returnable. 7