DORMA INTERIOR. DORMA PURE FAMELESS SLIDING Glass Wall Systems

Similar documents
Floating Headers - 4-1/8, 4-1/2, 6. with RTS88 and PT21 for double doors ONLY. Installation instructions

Headers - 4-1/8, 4-1/2, 6. with PT21 and Shear lock for single or double doors. Installation instructions

Muto Electro Magnetic Lock (Elock MEM4400) Installation instructions / Wiring manual

MUTO Premium & Comfort

TENSOR. Double-acting hinge for tempered glass doors. Interior glass systems. Equia nestotatus enis 2015

Universal & EA patch fittings

RETRACTED SIDE MINIMUM. 4 1/4 in. [108.0 mm] CP-493 HANGER (WITHOUT TRIGGER) RETRACTED SIDE CP-007 CLIP ACTIVATED SIDE MINIMUM. [108.

LAGUNA SERIES SLIDING DOOR KITS

TYPE CC-W CATCH N CLOSE CROWDERFRAME POCKET DOOR KIT INSTRUCTION SHEET FOR DOORS 26 in [660 mm] TO 48 in [1219 mm] WIDE ONLY

MULTIFUNCTION MANUAL SLIDING DOOR SYSTEM

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

DORMA BEYOND. Anti-Pinch Glass Door System

TS93 EMF T/PT/TDE. Surface applied door closer

Premium Dry Freight (Plywood) Door Installation REFERENCE FIGURE 1

1. Open front door (20124) and support using Rotunda Flexi-Work Table or equivalent.

BO to BO

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

S-Drive Performance Trainer

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

C15C C15C. Page 1 of 20

Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+

LIGHT DUTY ROLL UP DOOR

1PC TONNEAU COVER INSTALLATION INSTRUCTIONS IMPORTANT

VOLKSWAGEN AMAROK 3 PIECE HARD TONNEAU COVER INSTALLATION INSTRUCTIONS

D40C HINGE # x Support Plate x M8 Bolt 8 x M8 Washer 6 x M6 20mm Bolts 6 x M6 Washers 19 x Screws

B o d y S t r u c t u r e

Single and Bi-Parting Manual Sliding Doors. Installation. R-PLUS Cold Storage Doors

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

2-row and All-row systems included.

MUTO Comfort for demanding system solutions. MUTO The compact, flexible manual sliding door system

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

Installation Instructions I - Sheet Number I-TVR-01 Rev. A

Condor Manual. Corporation

3875 Cypress Drive Petaluma, CA Fax

SLIDING DOOR SYSTEM_ S42 TECHNICAL BOOK. System description Accessories

INSTALLATION, MAINTENANCE, & SAFETY INSTRUCTIONS

FUEL TANK BRACKET SAFETY RECALL

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Installation Instructions

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

SAFETY RECALL BULLETIN

PATCH FITTINGS. Universal, ARCOS & EA Patch Fittings for Tempered Glass Assemblies

B o d y S t r u c t u r e

K B J K A C H D E I F. Single and Bi-Parting Electric Sliding Doors with Automatic Operator (ICC-5) Parts List. R-PLUS Cold Storage Doors

ARB WINCH/NON WINCH BUMPER TO SUIT MITSUBISHI PAJERO NM FLARED. EXCLUDING EXCEED MODEL WARNING

Assembly Instructions

Installation Instructions Trektop NX

ESA II. I - Revive Slider Conversion Kit. Installation instructions

START HERE BEFORE YOU BEGIN STEP 2

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

THE SERIES-E POWR Slider

Bohle SlideTec optima 150 without Dampener Glass thickness 8, 10 or 12 mm tempered or laminated glass, up to 150 kg single leaf (with calculations)

multifunctional convenience MUTO the manual sliding door system with self-closing action and concealed locking.

TUB DOORS SHOWER DOORS

BALANCER DOOR WITH GEARBOX TENSIONER

CP-TK-2X4 POCKET TRIM KIT INSTRUCTION SHEET

GENUINE REAR SPOILER

NIS NAV AM (MY15 >) - Aluminium Tonneau Cover ATC0051 (silver) ATC0052 (Black) Installation Time: Approx. 60 Minutes WARNING!

Rolling & Wardrobe Doors

Installation and Service Manual

RS 120 & DRS 120. Hardware for manual sliding door systems. Equia nestotatus enis 2015

CIRRUS AIRPLANE MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS

STEP BY STEP INSTALLATION INSTRUCTIONS. Pleated Shades. Standard Control, Top Down/Bottom Up & Standard 2-on-1

Mini Cooper Mini Cooper. Vehicle Type: Two-Door Hatchback. Windshield. AutoGlass Field Guide 53

Lifting height 5.5" - 72" with adapters " Height overall 165" Width between columns 122" Drive through 109" Width overall 151.

ENCLOSURES & PANELS. The Trusted Source for Innovative Control Solutions

2005+ Roll Bar (Mm5RB-20.1 to -20.6) Recommended Center punch 1/8" pilot drill 1-3/4" Hole saw 2" Hole saw

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

Service Bulletin No. 3063

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Installation Instructions Trektop NX Twill

QTY 3D PN. FCS PART NUMBER DESCRIPTION

Rollstar Shade Installation Instructions

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

3PC TONNEAU COVER WITH SPORTS BAR INSTALLATION INSTRUCTIONS

Albany RR1000. Mechanical Installation Manual. PN: 6410T0029 Version - Rev: 04/23/2014. ASSA ABLOY Entrance Systems

Installation Instructions

(Refer to qualified personnel)

255 Cartridge Dual Seal

23-34 BODY COMPONENTS XJ VEHICLES J DOORS INDEX

Roller Shades MOTORIZED SHADE. Simplicity. Installation & Care Instructions

Lock-N-Load. Powder Measure and Case Activated Powder Drop

Installation Instructions

THT-100 ASTG THT-100 ASTG2 Security Turnstiles. Installation, Operation and Maintenance Manual. 1 Rev

Auto Sentry-eXP Maintenance. Revised 12/21/07

DEMOUNTABLE BODY INSPECTION PROCEDURE Follow Detailed Instructions Inside for Each Step

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Fabric Studio Custom Roll Shades Installation Instructions

Volkswagen New Beetle Body - Exterior 53 Body - Rear (Page GR-53)

Tooling Assistance Center

SLIDING DOOR SYSTEM_ AIR TECHNICAL BOOK. System description Accessories

Installation Instructions

Shaver Industries. Assembly Instructions Spring Assist Vertical Vinyl Curtain Door Projection Mount

Tool-less Hinged Closure Installation, Operation, & Maintenance

SUBARU FORESTER - SIDE STEP DIESEL VERSION INSTALLATION INSTRUCTIONS

In area - A -, a proper seal must be made against the top of the window glass.

Installation Instructions

Transcription:

TABLE OF CONTENTS Overview Intended use Structure requirements and fittings Requirements for glass panel Safety instructions Symbols used - safety/ installation Maintenance, care, repair Disposal 3 Overall view 3 Tempered laminate glass (TLG) and adhesive specifications 4 DIMENSIONS: Wall mount dimensions Ceiling mount dimensions 5 mount dimensions mount dimensions 6 INSTALLATION INSTRUCTIONS: OPTION 1 - WALL MOUNT: Securing track to mounting surface OPTION 2 - CEILING MOUNT WITHOUT SIDELITE: Securing track to mounting surface 7 OPTION 3 - CEILING MOUNT WITH SIDELITE: Securing track to mounting surface Securing sidelite profile and track to mounting surface 8 OPTION 4 - GLASS MOUNT: Door prep Preparing the track 9 Securing glass clamp profile and track to glass mounting surface 10 Installing the roller carriers: on monolithic glass ONLY 11 Installing the roller carriers: on tempered laminated glass ONLY 12 Installing dampener 13 Disengaging the anti-jump Installing the end stops 14 Install glass/rollers in track 16 Install floor guide Install floor guide: continued 17 Adjustment door height Engaging the anti-jump 18 Adjustment end stop location: LEADING end stop Adjustment end stop location: TRAILING end stop 19 Install dampener start/stops 20 Install cover clips Install brush profile 21 Install cover Install end caps 22 SIDELITE MOUNT ONLY: Installing u-channel for sidelite 14 Installing sidelite glass Installing sidelite glass filler panel 15 Installing sidelite glass gasket 16

Overview These instructions are for installation of the PURE sliding door system for the following mounting and style versions: 1. Wall mount 2. Ceiling mount (with/without sidelite) 3. mount Intended use - for sliding doors in dry indoor areas only - for manual slow opening and closing only Structure requirements and fittings - The substructure/wall must be able to bear permanent loads, be level and perpendicular (max. tolerance: 1/16" (2 mm) per meter [39-3/8"]). - Mounting hardware must be sufficiently dimensioned for the substructure/wall and weight of the door. Requirements for glass panel - Heat-soaked thermally tempered safety glass - Clamping area must be level and uncoated (no self-cleaning coating!) Safety instructions - Installation requires two people - Always wear protective clothing Symbols used Safety/Installation Caution! Mounting components must meet the requirements of substructure/wall and door weight. Please read the technical information for fittings. Risk of breaking glass When installing the door, support the door panel with a block of wood or similar object. Information note Always use silicone- and oil-free cleaners (e.g. acetone). Closing edge Maintenance, care, repair - immediately replace damaged parts - always use original DORMA parts - use a damp cloth for occasional cleaning, especially the track Disposal Dispose in accordance with local, state and national regulations. Overall view A C D A. PURE header assembly with roller carriers B. bottom U-channel (1x1") C. glass panel D. Sliding door panel E. Floor guide B E PURE Sliding 3

Tempered laminate glass (TLG) and adhesive specifications Required parts for laminate glass with MUTO System (not included) 3M Scotch-Weld Urethane Adhesive, DP 605 NS Color Part Number Quantity Usage recommendation off white 934.800 1 tube 1 tube per 4 roller carriers 3M Scotch-Weld EPX Plus II 934.801 1 applicator Applicator with 2:1 and 1:1 Plunger 2 3M Scotch-Weld EPX Plus II gold 934.805 (Pk of 4) 4 nozzles per 1 tube of Mixing Square Nozzle, 5.3mm 3 adhesive Laminated glass components 807.640 1 set Handling time frame Function Time Working life (time between application and clamping of carrier) 5 minutes @ 75 F Handling strength 20 minutes @ 73 F or more Full cure time (time until glass may be completely installed into door) 48 hours @ 73 F or more NOTE: Door glass should not installed until the full cure time as been reached (see chart above). Important safety-related information for the mounting and use of DORMA glass hardware. (Follow these instructions in addition to the mounting and operating instructions in order to avoid damage of product and damage to person or property.) Important: This document is intended to inform users of safety-related information and the mounting and operation instructions. General information 1. DORMA requires use of tempered monlithic glass. 2. DORMA glass hardware is not suitable for application in rooms where chemicals (e.g. chlorine) are used as indoor swimming pools, saunas or salt-water pools. 3. Never move sliding panels faster than walking speed and always slow the door manually before it reaches end position. Mounting 1. Only properly qualified and specially trained staff is authorized to mount DORMA glass hardware. 2. Never use glass with conchoidal fractures and/or damaged edges. 3. Due to crushing hazards and possible injury caused by breakage of glass during mounting, corresponding protective clothing (especially gloves and protective goggles) is required. 4. Clean clamping area with alcohol-based standard commercial cleaning agent before mounting the glass hardware. 5. Never clamp metal glass fitting hardware directly to glass surface. 6. Never use clamping roller carriers on self-cleaning coatings. 7. When adjusting glass elements, always stick to the required clearance for the respective hardware. Adjust clearance so glass does not come in contact with any hard surfaces such as glass, metal or concrete. 8. Do not use excessive force when installing the glass (avoid over tightening screws). Maintenance Check glass hardware at regular intervals for proper positioning and smooth operation and correct adjustment. High traffic door systems require inspection by properly qualified staff (specialized companies or installation firms). Immediately replace damaged glass elements (no glass flaking and/or conchoidal fractures)! Only use suitable cleaning and care products to clean the surfaces. 2 Scotch-Weld EPX Plus II Applicator with 2:1 and 1:1 Plunger is a trademark of 3M. 3 Scotch-Weld EPX Plus II Mixing Square Nozzle is a trademark of 3M. 4

Wall mount dimensions Track length = 2 x DW Top of track to center of mounting hole in track 15/16" [24mm] Hole height = TH - 15/16" [24] DW door Y clear opening height (CH) DH TH = DH + X 1-3/16" [30mm] clear opening height (CH) 1-3/16" [30mm] clear opening width (CW) Bottom of 3/8" glass to floor [10mm] DH door height clear opening height + 7/8" [22mm] + Y Y Top of clear opening to bottom of track TH Floor to top of track door height + X DW door width clear opening width + 2-3/8" [60mm] XL150/80 L80 X 1-7/8" [47mm] 1-9/16" [40mm] Ceiling mount dimensions Track length = 2 x DW Back of track to center of mounting hole in track 7/8" [23mm] door DW clear opening height (CH) DH TH = DH + X 1-3/16" [30mm] clear opening height (CH) 1-3/16" [30mm] clear opening width (CW) Bottom of 3/8" glass to floor [10mm] DH door height clear opening height + 7/8" [22mm] TH Floor to top of track door height + X DW door width clear opening width + 2-3/8" [60mm] XL150/80 L80 X 1-7/8" [47mm] 1-9/16" [40mm] 5

mount dimensions profile length & Track length (incl. endcaps 1/2" x 1/16" [13 x 2mm]) Back of track to center of mounting hole in track 7/8" [23mm] (DW) door panel (FPW) glass clear opening height (CH) FPH DH TH = DH + X clear opening width (CW) 1-3/16" [30mm] 5/16" [8mm] Bottom of glass to floor 3/8" [10mm] Bottom of glass to floor TH Floor to top of track door height + X DH Door height clear opening height + 7/8" [22mm] FPH Fixed panel (sidelite) height clear opening height - 2-7/16" [62mm] DW Door width clear opening width + 2-3/8" [60mm] FPW Fixed panel (sidelite) width track length - clear opening width XL150/80 L80 X 1-7/8" [47mm] 1-9/16" [40mm] mount dimensions Track length = 2 x DW Transom 15/16" [24mm] Top of track to center of mounting hole in track glass door panel glass clear opening height (CH) DH TH = DH + X 1-3/16" [30mm] 1-3/16" [30mm] Bottom of 3/8" glass to floor [10mm] DW DH Door height clear opening height + 7/8" [22mm] TH Floor to top of track door height + X DW Door width clear opening width + 2-3/8" [60mm] clear opening width (CW) XL150/80 L80 X 1-7/8" [47mm] 1-9/16" [40mm] 6

INSTALLATION INSTRUCTIONS OPTION 1 - WALL MOUNT: Securing track to mounting surface Wall track 1 1.1 Ensure the track is level and secure it to the wall per the appropriate measurements on the prior page. NOTE: SEE DIMENSION INSTRUCTIONS ON NEXT PAGE FOR REFERENCE. NOTE: WALL REINFORCEMENT: The wall reinforcement must be a minimum of ¼ (6mm) x 3 (76mm) steel angle, 16 gauge metal stud, or 1 1/2 (38mm) thick wood blocking secured to the wall studs on a maximum 16 (406mm) centers for the length of the track. The wall reinforcement may be flush on the wall surface or on the interior of the wall. For masonry walls the track may be secured directly to the wall with lead anchors. 1.2 Use appropriate fasteners according to the following recommendations. NOTE: Ensure screw head is flush with track. Track mounting screws must fully penetrate the steel angle, metal stud, or wood blocking, utilizing the predrilled holes in the MUTO track. Consult with a structural engineer to determine if reinforcement is adequate for your specific application or to meet specific codes in your location. OPTION 2 - CEILING MOUNT WITHOUT SIDELITE: Securing track to mounting surface Ceiling track 1 1.1 Ensure the track is level and secure it to the ceiling per the appropriate measurements on the following page. 1.2 Use appropriate fasteners according to the following recommendations. NOTE: SEE DIMENSION INSTRUCTIONS ON NEXT PAGE FOR REFERENCE. NOTE: OVERHEAD REINFORCEMENT: The overhead reinforcement must be a minimum of ¼ (6mm) x 3 (76mm) steel angle, 16 gauge metal stud, or two pieces of 1 1/2 (38mm) thick wood blocking (double stacked), secured to studs or joists on a maximum 16 (406mm) centers for the length of the track. The overhead reinforcement may be flush on the overhead surface or on the interior of this surface. Track mounting screws must fully penetrate the steel angle, metal stud, or at a minimum of 2 (51mm) into wood blocking, utilizing the predrilled holes in the MUTO track. Consult with a structural engineer to determine if reinforcement is adequate for your specific application or to meet specific codes in your location. 7

OPTION 3 - CEILING MOUNT WITH SIDELITE: Securing gasket to track Adhesive gasket 1A 1A.1 Determine handing of door. 1A.2 Ensure the track is cut to proper length. NOTE: SEE DIMENSION INSTRUCTIONS ON NEXT PAGE FOR REFERENCE. portion of track 1A.3 Cut adhesive gasket equal to sidelite glass width. 1A.4 Adhere gasket along bottom edge of back of track. Securing sidelite profile and track to mounting surface Track profile 1B profile Track 1B.1 Secure track to mounting surface. 1B.2 Align sidelite profile holes with track profile holes. NOTE: Holes will be predrilled every 7-7/8" [200mm]. 1B.3 Secure with proper fasteners. NOTE: Be sure fasteners are flush with track to avoid rollers catching protruding fasteners. NOTE: OVERHEAD REINFORCEMENT: The overhead reinforcement must be a minimum of ¼ (6mm) x 3 (76mm) steel angle, 16 gauge metal stud, or two pieces of 1 1/2 (38mm) thick wood blocking (double stacked), secured to studs or joists on a maximum 16 (406mm) centers for the length of the track. The overhead reinforcement may be flush on the overhead surface or on the interior of this surface. Track mounting screws must fully penetrate the steel angle, metal stud, or at a minimum of 2 (51mm) into wood blocking, utilizing the predrilled holes in the MUTO track. Consult with a structural engineer to determine if reinforcement is adequate for your specific application or to meet specific codes in your location. 8

OPTION 4 - GLASS MOUNT: Door prep 4-1/16" [103] 4-1/16" [103] DD DD DD DD 4-1/16" [103] Ø13/16" Ø[20] 1.75" [44.5] Clear opening (CW) 1.1 Use the equation at the right to determine the 'drilling distance' [DD] between each hole. DD = (CW - 106)/T 1.2 First find the measured 'clear opening width' [CW] on the chart at the right. 1.3 Determine 'T' for the equation. 1.4 Insert appropriate values into equation and calculate accordingly. SEE LEGEND BELOW FOR REFERENCE. Clear opening width T QHP CW 23-5/8" [600] CW 31-1/2" [800] 2 8 CW > 31-1/2" [800] CW 39-3/8" [1000] 3 10 CW > 39-3/8" [1000] CW 47-1/4" [1200] 4 12 CW > 47-1/4" [1200] CW 59-1/16" [1500] 5 14 Abbreviation CW DD T QHP LEGEND Description Clear opening width Drilling distance Division variable Qty of hole preps XL 150 (with dampener) XL 80 (with dampener) Min. door width 40-1/8" [1020] 31-7/8" [810] Min. clear opening width 37-13/16" [960] 29-1/2" [750] Max. door width 57" [1450] 57" [1450] Max. clear opening width 54-3/4" [1390] 54-3/4" [1390] 9

OPTION 4 - GLASS MOUNT (CONTINUED): Preparing the track L80 Clamping plate XL150/80 Clamping plate Set screw clamp profile Grommets Figure 1 Set screw 1A NO YES 1A.1 Slide clamping plates into end of glass clamp profile. NOTE: Quantity dependent upon number of holes in track. 1A.2 Orient plates properly as shown above; L80 or XL150/80. 1A.3 Secure via set screw. NOTE: Be sure set screw does not indent back of glass clamp profile. See Figure 1 for reference. 1A.4 Secure grommets to each clamping plate peg. Securing glass clamp profile and track to glass mounting surface Screw length [mm] 3/4" [20] 1" [25] X [mm] 3/8"-1/2" [10-13.5] 5/8"-3/4" [15-19] 1B clamp profile Clamping plate Track X 1B.1 Ensure the track is level. 1B.2 Align glass clamp profile clamping plates and track through glass mounting surface. 1B.3 Secure with proper fasteners per chart above. NOTE: SEE DIMENSION INSTRUCTIONS ON PRIOR PAGE FOR REFERENCE. 10

Installing the roller carriers: on monolithic glass ONLY Z DETERMINE THE LEADING (X) VERSUS TRAILING (Z) EDGE OF THE GLASS. "LEADING IS SIDE CLOSEST TO LATCH (CLOSED)." X Roller location on glass with dampener unit XL150/80 L80 Single door X 3-1/8" [80] 3-1/8" [80] Single door Z 1-9/16" [40] 1-9/16" [40] Legend: leading edge of glass Secure Roller carrier Torque value: gasket 10ft lbs [14Nm] Hex key size: XL150/80 = 4mm 2A (Front of) (Front of) L80 = 2.5mm NOTE: FULLY CLEAN SURFACE OF GLASS WITH AN ALCOHOL-BASED MILD GLASS AND SURFACE CLEANER. ENSURE NO DEBRIS IS ON THE GASKET. 2A.1 Slide roller carriers onto glass. 2A.2 Slide glass gasket and metal shim between glass and roller carrier. NOTE: Orient gasket with rubber side facing the glass. 2.3 Secure roller carriers to glass using appropriate-size hex key at 10ft lbs (14 Nm). 11

Installing the roller carriers: on tempered laminate glass ONLY DETERMINE THE LEADING (X) VERSUS TRAILING (Z) EDGE OF THE GLASS. "LEADING IS SIDE CLOSEST TO LATCH (CLOSED)." Z X Roller location on glass with spring dampener unit XL150/80 L80 XL150/80 L80 Single door X 3-1/8" [80] 3-1/8" [80] Z 1-9/16" [40] 1-9/16" [40] Legend: leading edge of glass Hex key size: XL150/80 = 4mm L80 = 2.5mm Torque value: 4ft lbs [5Nm] Vented set screws Roller carrier 3M Scotch- Weld EPX Plus II Applicator 2B gasket [Front of] [Front of] Stop when adhesive can be seen past end of roller carrier [Back of] NOTE: THE RECOMMENDED ADHESIVE'S SET-UP TIME IS 20 MINUTES FOR THE DUO-PAK CARTRIDGES. NOTE: FULLY CLEAN SURFACE OF GLASS WITH AN ALCOHOL-BASED MILD GLASS AND SURFACE CLEANER. ENSURE NO DEBRIS IS ON THE GASKET. 2B.1 Slide carriers onto glass. 2B.2 Slide laminated glass gasket and metal shim between glass and roller carrier. NOTE: Orient gasket with rubber side facing the glass. 2B.3 Tighten vented set screws using a torque wrench with 4 ft-lbs [5Nm]. NOTE: Onto scrap material, first dispense approximately 12" of 3M Scotch-Weld Urethane Adhesive prior to application to prevent mixing errors and ensure optimal hardening. Dispense adhesive into vented set screws on both sides of carrier. Stop application when adhesive can be seen past edge of roller carrier. DO NOT WIPE any excess adhesive from glass surface. Allow adhesive to dry and scrape off glass surface with a bevelededge chisel or putty knife. NOTE: Keep glass flat during curing process. NOTE: See chart in Specifications section for appropriate curing time. 12

Installing dampener Legend: leading edge of glass Dampener Triggers XL150 Roller carrier XL80 Triggers engaged L80 3 Dampener flush against LEADING roller carrier Hex key size: XL150/80 = 4mm L80 = 2.5mm 3.1 Slide dampener onto glass. NOTE: Oriented with triggers facing outward. 3.2 Dampener must be flush against leading roller carrier. NOTE: Leading carrier is on side of glass closest to latch. 3.3 Secure dampener to glass using appropriate-size hex key. 3.4 Engage triggers: push out towards end of unit. 13

Disengaging the anti-jump Antijump Antijump 4 NOTE: Anti-jump shipped engaged. Anti-jump adjustment screw Hex key size: XL150/80 = 4mm L80 = 2.5mm 4.1 Disengage the anti-jump on roller carrier. NOTE: Using an appropriate-size hex key, push anti-jump adjustment screw IN and turn COUNTER-CLOCKWISE to disengage anti-jump. Installing the end stops Set screw Track Hex key size: XL150/80 = 3mm L80 = 2mm 5 End stops Bottom section of end stop 5.1 Slide end stops into each end of the track. NOTE: Loosen bottom section of end stop for easier install. NOTE: FOR XL150 end stops, be sure set screw is flush with back of bumper. NOTE: Exact location/adjustments will be determined in step 15. WALL / CEILING / GLASS MOUNTS: If NOT using a sidelite application, skip to step #10. SIDELITE MOUNT ONLY: Installing u-channel for sitelite u-channel 6 6.1 Secure u-channel to floor using appropriate fasteners. NOTE: Ensure u-channel is plumb and the back of the u-channel profile aligns with back of sidelite profile. NOTE: Gaskets are pre-installed. 14

Installing sidelite glass profile glass Lift up into sidelite profile U-channel Lower down into u-channel U-channel setting blocks 1/8" gap glass glass Wall 7 7.1 Place setting blocks into u-channel. 7.2 Spray inside of u-channel with glass cleaner. 7.3 Lift glass up and into sidelite profile. 7.4 Lower glass into u-channel. 7.5 Ensure there is 1/8" [3] gap between wall and edge of sidelite glass. 7.6 If using tempered laminated glass, gently press glass against u-channel gasket, and dispense silicone along full length of non-gasket side of u-channel. Installing sitelite glass filler panel Track glass profile Filler panel 8 8.1 Fit filler panel between track and sidelite profile, on door side. 15

SIDELITE MOUNT ONLY: Installing sitelite glass gasket profile 9 gasket gasket location glass 9.1 Cut gasket to length. 9.2 Press gasket in between sidelite glass and sidelite profile. Install glass/rollers in track Wall Mount Mount glass panel Setting block locations Rollers Door panel Setting block locations Ceiling/ Mount Setting block locations Rollers 10 Rollers ENSURE ROLLERS AND TRACK ARE FREE OF DEBRIS. 10.1 Place glass on setting blocks on floor for stability. 10.2 Tip glass and rollers upward and rest rollers on track. 16

Install floor guide X XL150/80 13/16" [20mm] L80 11/16" [17mm] X Floor guide anchor Floor guide anchor Wall/ sidelite Wall 13/16" [20 mm] 1-7/16" [36 mm] 11 11.1 Separate floor guide pieces. 11.1 Align centerline of glass with centerline of floor guide. 11.2 Be sure glass is plumb. NOTE: Center of floor guide should be 13/16" [20mm] off the edge of the wall. 11.3 Mark appropriate floor guide measurements and remove glass and rollers from track. 11.4 Pre-drill into mounting surface using a 5/16" drill bit. 11.5 Secure floor guide with anchor and fasteners. Install floor guide: continued Floor guide anchor Floor guide Hex key size: XL150/80 = 1.5mm L80 = 1.5mm 12 12.1 Set glass and rollers onto track. 12.2 Slide floor guide over floor guide anchor and tighten with set screws. 12.3 Remove setting blocks. NOTE: Be sure glass is centered in floor guide. Set screws 17

Adjustment door height = = +3/16" [5] -3/16" [5] Door height adjustment tolerance XL150/80 L80 +3/16" [+5] -3/16" [-5] +3/16" [+5] -3/16" [-5] Height adjustment screw Floor guide 13 3/8" [10mm] XL150/80 torque 10 ft lbs [14 Nm] L80 torque 5 ft lbs [6 Nm] Height adjustment locking screws Hex key size: XL150/80 = 4mm L80 = 2.5mm 13.1 Set height of glass door. 13.2 Using appropriate-size hex key, loosen height adjustment locking screws of carrier. 13.3 Using appropriate-size hex key, turn height adjustment screw CLOCKWISE or COUNTER-CLOCKWISE to raise or lower glass. NOTE: Be sure glass is level during this adjustment. WALL / CEILING / SIDETITE / GLASS MOUNTS: Engaging the anti-jump Antijump 14 Antijump Anti-jump adjustment screw Hex key size: XL150/80 = 4mm L80 = 2.5mm 14.1 Engage anti-jump on roller carrier. NOTE: Using appropriate-size hex key, push anti-jump adjustment screw IN and turn CLOCKWISE to engage anti-jump. 18

Adjustment end stop location: LEADING END STOP 15 edge End stop overlap of door frame max. 1-3/16" [30mm] Frame edge 0mm Bumper Edge of roller carrier END STOP LOCATION: LEADING EDGE Handle LOCATION OF GLASS DOOR TO FRAME EDGE min. 1" [25mm] Door closed Handle to frame edge distance *Verify with local jurisdiction.* XL150/80 torque 3 ft lbs [4 Nm] Secure L80 torque 2.5 ft lbs [3 Nm] Hex key size: XL150/80 = 3mm L80 = 2mm NOTE: Pair of doors: Be sure there is a 1/4" [6mm] gap between the two doors. Set end stop locations: 15.1 Slide end stop to desired location on track. Bumper should touch edge of roller carrier. Bumper Adjustment end stop location: TRAILING END STOP 0mm END STOP LOCATION: LEADING EDGE Door opened Hex key size: XL150/80 = 3mm L80 = 2mm NOTE: Pair of doors: Be sure there is a 1/4" [6mm] gap between the two doors. Edge of roller carrier Bumper End stop Handle Set end stop locations: 15.1 Slide end stop to desired location on track. Bumper should touch edge of roller carrier. edge Frame edge LOCATION OF GLASS DOOR TO FRAME EDGE XL150/80 torque Secure L80 torque Bumper 15 min. 1" [25mm] Handle to frame edge distance *Verify with local jurisdiction.* 3 ft lbs [4 Nm] 2.5 ft lbs [3 Nm] 19

Install dampener start/stops Slide triggers in toward middle of Dormotion unit. Triggers CLOSING SIDE Slide triggers in toward middle of Dormotion unit. Legend: Closing edge of door 17.3 Slide door all the way CLOSED. 17.4 Carrier should touch end stop. 17.5 Slide start/stop into Dormotion trigger. 17.6 Rotate plates inside track to engage. 17.7 Tighten screws using appropriate-size hex key. End stop Edge of roller carrier Bumper start/stop OPENING SIDE 17.3 Slide door all the way OPEN. 17.7 Tighten screws using 17.4 Carrier should touch end stop. appropriate-size hex 17.5 Slide start/stop into Dormotion trigger. key. 17.6 Rotate plates inside track to engage. End stop Bumper Edge of roller carrier start/stop Plates parallel Plates parallel Start/stop locations Rotate in track Hex key size: XL150/80 = 4mm L80 = 2mm Set screw End stop Start/ stop Roller DORMOTION UNIT Start/ stop Roller End stop 16 16.1 Loosen screws on plates. NOTE: Plates should start out parallel to track. 16.2 Place start/stop into track channel. 16.3 (SEE STEPS 17.3-17.7 INSIDE IMAGE ABOVE.) 20

Install cover clips WALL MOUNT Cover clip CEILING / SIDELITE / GLASS MOUNTS Cover clip 17 17.1 Insert cover clips into track. (One clip per foot) 17.2 Insert perpendicular to track, and turn CLOCKWISE to snap into place. Install brush profile Cover Brush 18 18.1 Measure and cut brush to appropriate length. 18.2 Slide brush into cover. 21

Install cover WALL MOUNT SIDELITE / GLASS MOUNTS Cover Cover CEILING MOUNTS GENERAL SIDEVIEW Cover clip Cover Cover 19 19.1 Secure cover to clips and snap into place. NOTE: Roll cover from the bottom upwards. Ensure the bottom of the cover is supported by the groove in the cover clip. Install end caps GLASS MOUNT clamp profile Track clamp profile end caps WALL / CEILING / SIDELITE / GLASS MOUNTS End cap 19 End cap 19.1 Snap end caps onto track. 19.2 mount only: Slide glass clamp profile end caps into ends of glass clamp profile. 22

DORMA USA, INC. DORMA DRIVE, DRAWER AC REAMSTOWN, PA 17567 TOLL-FREE: 800-523-8483 FAX: 800-274-9724 WEBSITE: WWW.DORMA.COM 926964 11/2016, Subject to change without notice