AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

Similar documents
EcoPower Flush Valve. Warranty. Important Safeguards...1. Model Number and Specifications...2. Green Feature Operation Procedure...

3-Way Diverter Valve Trim Acabado De Diversora Garniture De Dérivation

DSE101E DSE101K DSE101EH DSE101KH DSE101EP DSE101KP

Owner s Manual FS-10/FreshSpa

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

MS604114CEF(G) MS634114CEF(G) MS853113E MS853113S MS854114ES(L) MS863113(E) MS864114(E)(L) MS MS924154F

Installation Instructions / Warranty

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

Installation Instructions / Warranty. Citterio 39115XX1

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

Installation Instructions / Warranty. Axor Citterio M 34315XX1

Installation Instructions / Warranty

Intelligent Electronic Safe

Installation Instructions / Warranty

Installation Instructions / Warranty

ESE Series Cast Iron Sewage Pumps

Installation Instructions / Warranty

Installation Instructions / Warranty. Starck 10456XX1

Installation Instructions / Warranty. Interaktiv

Installation / Warranty

Installation Instructions / Warranty

Installation Instructions / Warranty

Installation Instructions / Warranty

Installation Instructions / Warranty. Starck Semi-Pro

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Owner's Manual GROUNDHOG JETTER

Installation Instructions / Warranty. Axor Citterio 39835XX1

Installation Instructions / Warranty

Installation Instructions / Warranty

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

SAVE FOR CONSUMER INSTALLATION / OWNER S MANUAL. Includes: Tools: Mystic - Pull-Out Kitchen Faucet LKMY1041CR LKMY1041NK LKLFMY1041CR LKLFMY1041NK D 1

Installation Instructions / Warranty

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

Installation Instructions / Warranty. Starck 10458XX1

GARDEN HOSE UTILITY PUMP

Aquila Single Lever Vessel Faucet

Installation Instructions

Installation Instructions / Warranty. Trio Stop

Installation Instructions / Warranty. Interaktiv 06438XXX

BC632 / BCL632 BC635 / BC635

Installation Instructions / Warranty

StormPro BA Series Sump Pump

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Installation Instructions / Warranty

See Installation Guide

Installation Instructions / Warranty

Sheven Single Lever Vessel Faucet

Installation Instructions / Warranty. Axor Citterio 39840XX1

Installation Instructions / Warranty

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Aplos Single Lever Basin Faucet

Installation Instructions / Warranty. Raindance Allrounder 28110XX1 Wall Outlet Adapter with Hose Connection 28108XX1

Instructions for Tradewind. Please read before use. Model # Serial # Form # ADM Stowe Dr., Poway, Ca

Installation Instructions / Warranty

SUBMERSIBLE SUMP PUMPS

Owner s Manual & Safety Instructions

Installation Instructions / Warranty

G8 Portable Fuel Transfer Pump Owner s Manual

SUBMERSIBLE SUMP PUMPS

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation Instructions / Warranty. Starck 10444XX XX1

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

QUALITY MISTING PUMPS

PACIFICA Shower Cabin Installation Instructions

82V LITHIUM-ION BATTERY CHARGER GC 400

Installation Instructions / Warranty. PuraVida 15937XX1

INSTALLATION INSTRUCTIONS TOP MOUNT SINK CH366

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Installation Instructions / Warranty

Owner s Manual Drill and Light Weight Portable Utility Pumps

1/7 HANDLE TRIM INSTALLATION

Matala. VersiFlow Series. Instruction and Maintenance Manual

Britt Single Handle Commercial Kitchen Faucet

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

Installation Instructions

SUBMERSIBLE MINI-PUMP

IMPORTANT SAFETY INSTRUCTIONS

Single Lever Pull-Out Kitchen Faucet

Register your product within 30 days of purchase to activate your one-year limited manufacturer s warranty at ovente.com/register

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

Owner s Manual GLASSLINED PUMP TANK

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

INSTALLATION INSTRUCTIONS TOP MOUNT SINKS

Where to Find Us. Pressure Washer. Model Number Revision Serial Number. Date Purchased

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

G SERIES - E TOUCH MIXER / TAP

Free Float Air Trap G8

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Water Broom. Instruction manual ESPAÑOL: PÁGINA 7 FRANÇAIS : PAGE 13 MODEL PCA270

Installation Instructions

Transcription:

INSTRUCTION MANUAL NOTE TO INSTALLER : PLEASE GIVE THIS MANUAL TO THE CUSTOMER AFTER INSTALLATION. AUTOMATIC FAUCET Important Safeguards Precautions Model Number and Components Before Use How to Use How to Adjust Maintenance Periodical Checking Troubleshooting Specifications WARRANTY

Important Safeguards (For your safety, please follow the instructions below.) Read these Important Safeguards instruction thoroughly before using your Automatic Faucet, and follow the precaution instructions carefully. After you read this Instruction Manual, keep it where it can be easily referred to again. Symbols are shown for safe and proper use of your Automatic Faucet and in order to alert you possible personal injury and damage to your property. The symbols and their meanings are as follows. Warning The items of observation are classified and described. Ignoring these symbols may cause personal injury or property damage. Getting Started Absolutely "Do not". Do not disassemble. Do not touch the area specified. Some models may have different component as illustrated below. Do not install the product in high humidity area such as a bathroom. This means mandatory. Never splash water on the controller. Warning (NG:Not Good) The Automatic Faucet is an electrical appliance, this may cause product malfunction. Do not strike or kick to the Automatic Faucet. Controller Do not This may cause product malfunction or water leakage. Do not use the Automatic Faucet at temperatures exceeding what local codes allow. It may cause product malfunction. below local code Do not place an item with this symbol displayed in a room with high humidity such as bathroom. Do not use in humid areas Do not disassemble This may cause product malfunction. Never attempt to disassemble, reassemble, repair or modify the Automatic Faucet, unless you are an electrician. This may cause product malfunction and electric shock.

Warning (NG:Not Good) Do not touch the stop valve of the controller, the surface may be very hot. Ouch! Don't touch This may cause personal injury. For Dynamo model, disconnect the back-up battery connector, when the Automatic Faucet is not in use for a long period of time. Controller Disconnect Mandatory Always close the stop valve(s) before cleaning the strainer. (Refer to P.8) Hot or cold water may flow out and cause personal injury or property damage. Periodically check the piping for leakage. Getting Started Ignoring this may cause property damage. No leakage! When the room temperature falls under freezing condition, give proper care to the piping to prevent product malfunction. If the piping is frozen, the components may suffer damage and leakage. Wrap the piping with heat insulation. Brrrr Precautions (Observe the following precaution instructions) Make sure the power cord does not come in contact with the hot-water supply pipe. (In case of thermostatically controlled mixing valve.) High temperature may damage to the product. Avoid placing any objects within the detection range of the infrared sensor. May result in faulty operation. Occasionally turn the temperature control handle of the thermostatically controlled mixing valve to prevent buildup or sticking. Debris may form inside of the valve, resulting in impaired performance. Routine maintenance must be performed.

Model Number and Components < Model Number > single supply faucet dynamo type battery type standard gooseneck TEL3 TEL3 TEL3 TEL3 thermal mixing valve faucet dynamo type battery type TEL5 TEL5 TEL5 TEL5 TEL-10 TEL-60 Duration of water discharge : 10 seconds Duration of water discharge : 60 seconds Getting Started standard sensor part spout outlet spout sensor P.46 hexagonal nut spout sensor cord dynamo single supply faucet spout connecting hose with flexible tube dynamo P.5 controller controller cover thermal mixing valve faucet sensor cord spout connecting hose with flexible tube controller cover dynamo P.5 spout connecting hose sensor cord water inlet bracket with strainer temperature control handle water inlet bracket P.5 with strainer spout spout connecting hose with flexible tube sensor cord spout connecting hose with flexible tube gooseneck spout outlet sensor part sensor P.46 hexagonal nut spout connecting hose sensor cord battery batteries P.7 controller cover controller cover batteries P.7 sensor cord temperature control handle water inlet bracket with strainer water inlet bracket P.5 with strainer

How to Use Before Use Confirmation of connectors Make sure all connections are made. Sensor connector (green) Back-up battery connector (for dynamo type : white) Battery connector (for battery type : white) For Single supply faucet Pull Cover Screw Sensor connector (green) For Thermal mixing valve faucet Screw Back-up battery connector (for dynamo type : white) Battery connector (for battery type : white) Dynamo type Screws Cover Sensor connector (green) Cover Battery type Back-up battery connector (for dynamo type : white) Battery connector (for battery type : white) Normal operation How to use 1. Place your hands under the faucet. The sensor will automatically turn on the water. 2. Remove your hands. The sensor will automatically turn off the water.

How to Adjust Bits of Knowledge About Dynamo Model Mechanism for Hydropowered generator The flow of water causes the turbine in the power generator to rotate, generates electric power, and enables the Automatic Faucet to operate. Spout Power generator A turbine rotates to generate power. Cover Coil Electric power is stored. Turbine The Automatic Faucet is using the charged power. Water supply Controller Solenoid valve Controller unit Using the faucet 11 times a day for 5 seconds or more will fully recharge the faucet. How to Use How to adjust the temperature Turn the temperature control handle. The water temperature has been factory set to 100F (38C). Depending on the conditions of both the cold and hot water supply, adjust the temperature by turning the temperature control handle as necessary. Thermostatically controlled mixing valve Temperature control handle Hot Cold Adjustment of the flow rate With the built-in regulator valve - 1.06gpm (4L/min.), there is no need to adjust the flow rate. Use the Automatic Faucet with the stop valve fully opened. If you need to regulate the flow rate, adjust it by turning the stop valve. However, the Dynamo model must be used with the stop valve fully opened. If you need to regulate the flow rate, make sure the flow rate is more than 0.8gpm (3L/min.). Close Open Stop valve

Maintenance Follow these instructions for daily maintenance. Use soft cloth for maintenance For general cleaning Use a damp, soft cloth to clean the spout and the sensor. For cleaning dirt Use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth. Caution Do not scratch the sensor when cleaning. Sensor part Outlet Avoid using anything that may scratch the spout surface. Never use polishing powder, detergent that includes coarse particles, thinner, benzine, acid or alkaline detergent, or a nylon scrub brush. They will damage the surface of the spout. Low Battery Indicator (Battery operated models) 1 ST Indication Flow time reduced to 2 seconds. (Normally 10 or 60 seconds) 2 ND Indication If continued to use after 1 ST indication Water flow will stop and sensor light will blink every 4 seconds. Battery Specifications Use only AA alkaline batteries (2pcs). 2 years battery life expectancy, based on 4,000 cycles per month. Replace batteries every 2 years as preventative maintenance. Maintenance Sensor Sensor light

Battery Replacement Procedure (Battery operated models) 1. Remove the controller cover. (See page 4) 2. Detach the battery connector (white). 3. Remove the rubber cover from the battery case and replace the AA alkaline batteries. For Single supply faucetfor Thermal mixing valve faucet controller battery case controller battery case 4. Reassemble. Caution Replace only with 2 AA alkaline batteries. Follow the "battery warning note" on the batteries. Please remove batteries from the faucet when not in use for a long period of time. battery connector (white) rubber cover Disconnect white connector by hand + battery connector (white) + battery case batteries Periodical Checking Maintenance Please check your Automatic Faucet at least once a month according to the following instructions. Leakage Check the piping to see whether there is any leakage. Ignoring this may cause property damage. No leakage! Water temperature For thermostatically controlled mix valve, turn the temperature control handle four or five times. Temperature control handle Build up may form inside, resulting in impaired performance if maintenance is not performed. Controller

Loose spout Check if the spout is loose. If the spout is loose, tighten the hexagonal nut underneath the spout. Flow rate When the strainer or spout nozzle is clogged, the flow rate will decrease. Make sure to clean the strainer and the spout nozzle. Pay special attention to the dynamo model, since low flow rate may result in low power generation. (see page 6) Cleaning the strainer Open Close Stop valve 1. Close the stop valve. 2. Remove the strainer cover with the open-close tool. 3. Pull out the strainer and clean it with a brush. 4. Put the strainer back in its place. 5. Reopen the stop valve fully. Open-close tool Open Strainer Strainer cover Brush Cleaning of the spout nozzle 1. Remove the spout nozzle with the supplied open-close tool. 2. Clean the spout nozzle with a brush to remove dirt from the screen. 3. Set the spout nozzle back in place. Strainer Close Open-close tool Open Spout nozzle Brush Spout nozzle Maintenance

Troubleshooting Before contacting a repairman, check the following common problems and solutions. If the problem persists contact your dealer. Problem Cause Solution Ref. page The surface of the sensor is dirty. Clean the surface of the sensor. P.6 There is an obstruction in front of the sensor. Remove the obstruction. P.2 The stop valve is turned off. Turn on the valve. P.6 Dynamo model: Backup battery connector is disconnected. Connect the backup battery connector. P.4 Water doesn't run. The power generator and sensor connection are not attach. Securely attach the connector(s). P.4 Water supply is suspended. Wait until water supply is restored. The strainer or the spout nozzle is clogged. Clean the strainer and the spout nozzle. P.8 The batteries are dead. Replace the batteries. P.7 Battery-operated model: No batteries installed. Install batteries in the controller. P.7 The surface of the sensor is dirty. Clean the surface of the sensor. P.6 Water doesn't stop. There is an obstruction in front of the sensor. Remove the obstruction. P.2 If water continues to run after attempting above, turn off the stop valve. Low flow rate. Stop valve is not fully opened. The strainer or the spout nozzle is clogged. Open the stop valve fully. Clean the strainer and the spout nozzle. P.6 P.8 Water temperature is too high. The temperature control handle is set at "H". The stop valve connected to the cold-water supply is not fully opened. Set the temperature control handle to the middle point. Open the cold-water stop valve fully. P.5 P.6 The temperature control handle is set at "C". Set the temperature control handle to the middle point. P.5 Water temperature is too low. The stop valve connected to the hot- water supply is not fully opened. Open the hot-water stop valve fully. P.6 The hot-water supply temperature is lower than 120F. Set the hot-water supply temperature to 120F. Troubleshooting Water temperature is not controlled properly. Water flow from the faucet stops about 2 seconds later. One side of the stop valve is not fully opened. Open the stop valve fully. P.6 The strainer or the spout nozzle clogged. The batteries are dead. Clean the strainer and the spout nozzle. Replace the batteries. The self-adjusting sensor may not work Short detection range. properly when stained or blocked by water Clean the sensor surface. P.6 droplets. P.8 P.7

This automatic faucet is equipped with a self-adjusting sensor which automatically adjust its detection range once every 15 seconds. This sensor may exhibit the following phenomena. Note these are implemented for safety and conservation purposes, they are not malfunctions. Phenomenon After sometime water stops flowing even if your hands are still under the faucet. After removing hands water keeps running for 15 seconds. Explanation The sensor activates by detecting hand movements. If your hands are not moving, it will be regarded as an ordinary object. Even if your hands are moving, the faucet will only keep running for 1 minute for safety purposes. If the sensor is stained or blocked by water droplets, the water may keep running even after you removed your hands. In such a case, the self-adjusting sensor will stop the water after 15 seconds. Always wipe off all water droplets and stains from the sensor. Specifications Dynamo Power supply - Battery life - Detection range from the sensor Water supply pressure Water supply connection Ambient temperature Humidity Flow rate Duration time of water discharge Discharge quantity Battery Alkaline type AA batteries 1.5V2pcs. 2 yrs. Life based on 4,000 cycles per month 5-1/8"7-7/8" (130200 mm) sensor is self-adjusting minimum required water pressure : 7 PSI (50 kpa) (Flowing) for Single faucet : 13 PSI (90 kpa) (Flowing) for Thermal mixing faucet maximum water pressure : 125 PSI (862 kpa) 1/2" NPSM 32104F(040C) Max. 90% RH 1.06 gallon per minutes (4 L/ min.) controlled by gobernor 10 seconds 60 seconds Max. 0.25 gallon per cycle (0.95 L/cycle) for 10 seconds type Troubleshooting

WARRANTY 1. TOTO warrants its products to be free from manufacturing defects under normal use and service for a period of three (3) years from the date of purchase. This warranty is extended only to the ORIGINAL PURCHASER. 2. TOTO s obligations under this warranty are limited to repair or replacement, at TOTO s option, of products or parts found to be defective, provided that such products were properly installed and used in accordance with OWNER S MANUAL. TOTO reserves the right to make such inspections as may be necessary in order to determine the cause of the defect. TOTO will not charge for labor or parts in connection with warranty repairs or replacements. TOTO is not responsible for the cost of removal, return and/or reinstallation of products. 3. This warranty does not apply to the following items: a) Damage or loss sustained in a natural calamity such as fire, earthquake, flood, thunder, electrical storm, etc. b) Damage or loss resulting from any unreasonable use, misuse, abuse, negligence, or improper maintenance of the product. c) Damage or loss resulting from removal, improper repair, or modification of the product. d) Damage or loss resulting from sediments or foreign matter contained in a water system. e) Damage or loss resulting from improper installation or from installation of a unit in a harsh and/or hazardous environment. f) Damage or loss resulting from acts of animals such as mice and insects. g) Damage or loss resulting from a use of abnormal power supply. h) Damage or loss resulting from abrasion of consumable supplies. i) Damage or loss resulting from frost. 4. This warranty gives you specific legal rights. You may have other rights which vary from State to State. 5. To obtain warranty repair service under this warranty, you must take the product or deliver it prepaid to a TOTO service facility together with a letter stating the problem, or contact a TOTO distributor or products service contractor, or write directly to TOTO U.S.A., INC., 1155 Southern road, Morrow, Georgia 30260, (770) 282-8686. If, because of the size of the product or nature of the defect, the product cannot be returned to TOTO, receipt by TOTO of written notice of the defect shall constitute delivery. In such case, TOTO may choose to repair the product at the purchaser s location or pay to transport the product to a service facility. THIS WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY TOTO. REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY SHALL BE THE EXCLUSIVE REMEDY AVAILABLE TO THE PURCHASER. TOTO SHALL NOT BE RESPONSIBLE FOR LOSS OF USE OF THE PRODUCT OR FOR OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OR EXPENSES INCURRED BY PURCHASER, OR FOR LABOR OR OTHER COSTS DUE TO INSTALLATION OR REMOVAL, OR COSTS OF REPAIRS BY OTHERS, OR FOR ANY OTHER EXPENSE NOT SPECIFICALLY STATED ABOVE. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES, INCLUDING THAT OF MERCHANTABILITY OR FITNESS FOR USE, ARE EXPRESSLY LIMITED TO THE DURATION OF THIS WARRANTY. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS. OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION AND EXCLUSION MAY NOT APPLY TO YOU. 1999 TOTO USA, Inc. 1155 Southern Road, Morrow GA 30260 Phone 770-282-8686 Fax 770-282-8701 www.totousa.com TOTO USA, INC. is a wholly owned subsidiary of TOTO Ltd. Printed in July, 2002 03752