Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Similar documents
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Seated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread

Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way

2, 3 and 4 - way valves VZL

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

Flow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

k VS DN (mm) Connections ( C) (m 3 /h)

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange

Pressure relief controller AVA (PN 25)

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2

Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Seated valve (PN 16 & PN 25) VFM 2 Two way valve, flange

Pressure relief controller for oil V22D28 (PN 16, 25)

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

3-port seat valves PN16 with flanged connection

Pressure independent balancing and control valve

Differential pressure relief controller AFPA / VFG 2 (VFG 21)

2-port seat valves PN16 with flanged connection

Differential pressure controller AFP / VFG 2 (VFG 21)

3-port seat valves PN6 with flanged connection

Pressure independent balancing and control valve AB-QM DN

Pressure independent balancing and control valve AB-QM DN

3-port seat valves PN10 with flanged connection

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

3-port seat valves PN16 with flanged connection

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

3-port seat valves, external thread, PN16

CONTROL EQUIPMENT STAZ-16, STBZ-16

Differential pressure controller AFP / VFG 2 (VFG 21)

Automatic balancing valves ASV-PV DN (3rd gen.)

3-port valves vxf42..

76.116/1. BUE: Flanged three-way valves, PN 16/10. Sauter Components

3-Port Seat Valves with Flange, PN 6

3-Port Seat Valves with Flange, PN 10

Butterfly valves PN6, PN10, PN16

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

3 & 4-Way Rotary Valves

Flow-compensated temperature controller AVTQ DN 15

Static Balancing Valve

Two-port seat valves with male thread, PN16

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

Butterfly valves PN 16

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Control valves with pneumatic actuators up to 350 C PN

BQE: 3-way flanged valve, PN 16

BUD: 3-way flanged valve, PN 6 (pn.)

BUE: 3-way flanged valve, PN 16/10 (el.)

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

3-Port Seat Valves with Male Thread, PN 16

ON/OFF zone valves AMZ 112, AMZ 113

Flow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line

2-Port Seat Valves with Flange, PN 25

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Butterfly valves PN6, PN10, PN16

Butterfly valves, PN6, PN10, PN16

VUD: 2-way flanged valve, PN 6 (pn.)

2-way and 3-way globe valves

Series 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244

Combined Self-operated Regulators Regulators for Differential Pressure, Flow Rate and Temperature

Connection. k VS -Value m 3 /h

High Pressure 2-way 2 1/2-6 Globe Valves

Control shut-off butterfly valves DN 25 DN 200 PN

3-Port Seat Valves with Male Thread, PN 16

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

Butterfly valves PN 16

Your Personal Catalog Temperature Controllers All our know-how - is now yours

Connection. k VS -Value m 3 /h

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

2-port seat valves PN25 with flanged connection

Control valves with electric actuators up to 90 C PN

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

2- and 3-port valves with flanged connections, PN 16

V5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

2- and 3-port valves with flanged connections, PN 6

Differential pressure controller AFP / VFG 2 (VFG 21)

V5822A/5823A,C/V5832A/V5833A,C

Transcription:

Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications. The valves are designed to be combined with following actuators: DN 15-50 with AMV(E) 335, AMV(E) 435 or AMV(E) 438 SU actuators DN 65-80 with AMV(E) 335 or AMV(E) 435 actuators DN 100 with AMV(E) 55 or AMV(E) 56, AMV 423, AMV 523 actuators Combinations with other actuators could be seen under Accessories. Features: Bubble tight design Snap mechanical connection together with AMV(E) 335, AMV(E) 435 Dedicated 2-port valve Suitable for diverting applications (3-port) Main data: DN 15-100 k VS 0.63-145 m 3 /h PN 6 Temperature: - Circulation water/glycolic water up to 50 %: 2 ( 10*) 120 C * At temperatures from 10 C up to +2 C use stem heater Flange PN 6 connections Compliance with Pressure Equipment Directive 97/23/EC Ordering Example: 2-way valve, DN 15, k VS 1.6, PN 6, t max 120 C, flange connection - 1 VL 2 DN 15 valve Code No.: 065Z0373 2-way valve VL 2 k VS t max. DN (m 3 /h) ( o C) Code No. 0.63 065Z0371 1.0 065Z0372 15 1.6 065Z0373 2.5 065Z0374 4.0 065Z0375 20 6.3 065Z0376 25 10 120 065Z0377 32 16 065Z0378 40 25 065Z0379 50 40 065Z0380 65 63 065Z0381 80 100 065Z0382 100 145 065Z3426 3-way valve VL 3 k VS t max. DN (m 3 /h) ( o C) Code No. 0.63 065Z0351 1.0 065Z0352 15 1.6 065Z0353 2.5 065Z0354 4.0 065Z0355 20 6.3 065Z0356 25 10 120 065Z0357 32 16 065Z0358 40 25 065Z0359 50 40 065Z0360 65 63 065Z0361 80 100 065Z0362 100 145 065Z3413 DEN-SMT/SI VD.LS.F4.02 Danfoss 05/2011 1

Ordering (continued) Accessories - Adapter DN Actuators max. p (bar) Code No. 15-50 AMV(E) 15, 25, 35, 323, 423, 523 4.0 065Z0311 65-80 AMV(E) 55, 56, 323, 423, 523 2.5 065Z0312 Accessories - Stem heater Service kits DN Actuators Power supply Code No. 15-80 AMV(E) 335, 435 065Z0315 15-50 AMV(E) 438 SU 24 V 065B2171 65-100 AMV(E) 55, 56 065Z7020 Type DN Code No. 15 065Z0321 20 065Z0322 25 065Z0323 Stuffing box 32 065Z0324 40/50 065Z0325 65/80 065Z0327 100 065B1360 Technical data Nominal diameter DN 15 20 25 32 40 50 65 80 100 k VS value m 3 /h 0.63 1.0 1.6 2.5 4.0 6.3 10 16 25 40 63 100 145 Stroke mm 10 15 20 30 Control range 30:1 50:1 100:1 Control characteristic LOG: port A-AB; LIN: port B-AB Cavitation factor z 0.4 Leakage A - AB bubble tight design B - AB 1.0 % of k VS Nominal pressure PN 6 Max. closing pressure (mixing) 4 2.5 1.0 1) bar Max. closing pressure (diverting) 1 Not applicable Medium Circulation water / glycolic water up to 50 % Medium ph Min. 7, Max. 10 Medium temperature o C 2 ( 10 2) ) 120 Connections Flange PN 6 acc. to EN 1092-2 Materials Valve body Grey cast iron EN-GJL-250 (GG-25) Valve stem Stainless steel Valve cone Brass 3) Stuffing box sealing EPDM 1) 1.5 bar at AMV(E) 55 2) At temperatures from -10 up to +2 C use stem heater 3) At DN 100 red bronze CuSn5Zn5Pb5 (Rg 5) 2 VD.LS.F4.02 Danfoss 05/2011 DEN-SMT/SI

Pressure temperature diagram PN 6 working area EN-GJL-250 (GG-25) Maximum allowed operating pressure as a function of medium temperature (flanges according to EN 1092 2) Valve characteristics Valve characteristics log (2-way) Valve characteristics log/lin (3-way) Disposal The valve must be dismantled and the elements sorted into various material groups before disposal. DH-SMT/SI VD.LS.F4.02 Danfoss 05/2011 3

Installation Valve mounting Before valve mounting the pipes have to be cleaned and free from abrasion. Valve must be mounted according to flow direction as indicated on valve body. Mechanical loads of the valve body caused by the pipes are not allowed. Valve should be free of vibrations as well. Installation of the valve with the actuator is allowed in horizontal position or upwards. Installation downwards is not allowed. A AB A AB B Mixing Fig. 1: Mixing or diverting connection B Diverting Fig. 3: Mixing valve used in diverting application Fig. 2: Mixing valve used in mixing application Fig. 4: Diverting valve used in diverting application Mixing or diverting connection 3-way valve can be used either as mixing or diverting valve (fig.1). If 3-way valve is installed as mixing valve meaning that A and B ports are inlet ports, and AB port is outlet port it can be installed in mixing (fig.2) or diverting application (fig.3). 3-way valve can be also installed as diverting valve in diverting application (fig.4) meaning that AB port is inlet and A and B ports are outlets. Note: Only valves DN 15-50 are suitable for diverting installation. Maximal closing pressure for mixing and diverting installation are not the same. Please refer to values stated in Technical data section. 4 VD.LS.F4.02 Danfoss 05/2011 DEN-SMT/SI

Sizing Flow Rate (liquid with specific a gravity of 1) l/sec m 3 /h Δp max FLOW Pressure drop kpa (100 kpa = 1bar = ~ 10 m H 2 O) Example Design data: Flow rate: 6 m 3 /h System pressure drop: 55 kpa Locate the horizontal line representing a flow rate of 6 m 3 /h (line A-A). The valve authority is given by the equation: p1 Valve authority, a = p1+ p2 Where: Δp1 = pressure drop across the fully open valve Δp2 = pressure drop across the rest of the circuit with a full open valve The ideal valve would give a pressure drop equal to the system pressure drop (i.e. an authority of 0.5): if: Δp1 = Δp2 a = Δp1 2 Δp1 = 0.5 The intersection of line A A with the diagonal lines gives the pressure drops stated by real, rather than ideal, valves. In this case, a valve with k VS 6.3 would give a pressure drop of 90.7 kpa (point C): 90.7 hence valve authority = = 0.62 90.7 + 55 The second largest valve, with k VS 10, would give a pressure drop of 36 kpa (point D): 36 hence valve authority = = 0.395 36 + 55 Generally, for a 3 port application, the smaller valve would be selected (resulting in a valve authority higher than 0.5 and therefore improved control). However, this will increase the total pressure and should be checked by the system designer for compatibility with available pump heads, etc. The ideal authority is 0.5 with a preferred range of between 0.4 and 0.7. In this example an authority of 0.5 would be given by a valve having a pressure drop of 55 kpa at that flow rate (point B). The intersection of line A A with a vertical line drawn from B lies between two diagonal lines; this means that no ideally-sized valve is available. DH-SMT/SI VD.LS.F4.02 Danfoss 05/2011 5

Design (Design variations are possible) VL 2 1. Valve body 2. Valve insert 3. Valve cone 4. Valve stem 5. Moving valve seat (pressure relieved) 6. Stuffing box 6 VL 3 1. Valve body 2. Valve insert 3. Valve cone 4. Valve stem 5. Valve seat 6. Pressure relieve chamber 7. Stuffing box 7 6 VD.LS.F4.02 Danfoss 05/2011 DEN-SMT/SI

Dimensions VL 2 (DN 15-80) AMV(E) 335, 435 + AMV(E) 438 SU + VL 2 (DN 15-80) VL 2 (DN 15-50) VL 3 (DN 15-80) AMV(E) 335, 435 + AMV(E) 438 SU + VL 3 (DN 15-80) VL 3 (DN 15-50) Type VL 2 VL 3 DN L H H1 H2 k d2 Weight n mm (kg) 15 130 40 191 216 55 11 4 1.48 20 150 45 194 218 65 11 4 2.07 25 160 50 197 222 75 11 4 2.59 32 180 60 202 226 90 14 4 3.82 40 200 65 213 237 100 14 4 5.28 50 230 70 218 242 110 14 4 6.74 65 290 88 254-130 14 4 13.90 80 310 95 258-150 19 4 17.22 15 130 63 191 216 55 11 4 1.93 20 150 70 194 218 65 11 4 2.68 25 160 75 197 222 75 11 4 3.59 32 180 80 202 226 90 14 4 5.17 40 200 90 230 255 100 14 4 7.08 50 230 100 243 267 110 14 4 10.11 65 290 120 254-130 14 4 16.15 80 310 155 270-150 19 4 22.36 Note: If stem heater is used dimension H is increased for 31 mm, dimension H2 is increased for 5 mm. DH-SMT/SI VD.LS.F4.02 Danfoss 05/2011 7

Dimensions (continued) VL 2 (DN 100) VL 3 (DN 100) AMV(E) 55, 56 + AMV 423, 523 + VL 2, VL 3 (DN 100) VL 2, VL 3 (DN 100) L H H1 H2 k d2 Weight Type DN n mm (kg) VL 2 196 39.0 100 350 406 317 170 18 4 VL 3 175 34.0 Note: If stem heater is used dimension H remains the same. 8 VD.LS.F4.02 Produced by Danfoss A/S 05/2011