PR-PUB-NLH-034 NLH 2015 Prudence Review Page 1 of 1

Similar documents
PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4

V. Design, Application, Maintenance & Operation Technical Requirements

GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

6. Document tasks performed during visit and report any observations to the appropriate

Substation Maintenance Training

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

If you have any questions, please do not hesitate to contact the Board's Legal Counsel, Ms. Jacqui Glynn, via or (709)

Appendix C. Interval Every 2 Year. Functional Test Weekly Monthly Quarterly. Semi. Every 3. Engineering Studies

Hydro Plant Risk Assessment Guide

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

A REPORT TO THE BOARD OF COMMISSIONERS OF PUBLIC UTILITIES. Electrical. Mechanical. Civil. Protection & Control. Transmission & Distribution

N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related

ST Charger. Industrial Battery Charger

1ZSE en, Rev. 4. On-load tap-changers, type UC User s manual

In any of the 5 star hotels. The exact venue will be informed once finalized.

GPA 13.8 kv Semi-Annual Slip Ring PM, Sav 10-41

Publication No.: PSG

Substation Equipment (Bushings)

ENGINEERED TO ORDER SOLUTIONS

PRACTICAL TROUBLESHOOTING OF ELECTRICAL EQUIPMENT & CONTROL SYSTEMS

engineered to order solutions

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

UPS Battery Maintenance Training

Smart Grid Automation and Centralized FISR

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

OCTOBER 17, Emera Maine Representative: Jeffrey Fenn, P.E., LR/SGC Engineering LLC

Hydro Plant Risk Assessment Guide

Upgrade Power Transformers

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Operation and maintenance of 11kV, 33kV and 220 kv Substation.

BOILER PM & INSPECTION

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

UniSec Maintenance solutions

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Electrical maintenance and testing guidelines! endre.

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

CENTRIFUGAL CHILLER. Lubrication System Pull oil sample for spectroscopic analysis.

Natural Ester Fluid Diagnostics

EISHO TEK. Vacuum Circuit Breaker

Testing and Maintenance of Electrical Equipment with a focus on switchgear

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

SRT OPERATIONS MANUAL

SIEMENS Transmission and Distribution

S&C Type FVR Substation Circuit Breaker

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Asset Category Batteries LPN

When power interruptions happen.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Related Electrical Systems 1

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Three-Phase Pole Mounted Recloser

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

Product Specifications for Phase Over Phase GOABS(r)

Centro América Application of EMI Diagnostics to Diesel Generators

REVELSTOKE - 1 YEAR DOWN. Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004

Distribution transformers Efficiency over life-cycle

Extracting Valuable Information from HV Circuit Breaker Testing. Charles Sweetser - OMICRON MIPSYCON 2014

Net Metering Policy Framework. July 2015

Applied Technology Services Overview

Emera Maine Representative: Jeffrey Fenn, P.E., SGC Engineering LLC

Horizontal Circuit Switchers

Horizontal Circuit Switchers

INSTRUCTION MANUAL #103

DELTA4000 Accessories

Transformer Components & Accessories

Thermography Report. Inspection Site: Lucky Mining Co. Rocky Rd Smithville, NSW. Requested By: John Seemore. Date of Inspection:

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

User manual W-VACi. W-VACi 12 / 17.5 / 24 kv IEC Vacuum Circuit Breakers

Medium Voltage Metal-Enclosed Switches

B kv Gas-insulated Substations

BUZZI UNICEM USA PRESIDENT S ISLAND TERMINAL MEMPHIS, TENNESSEE

Section 5 - Operations and Maintenance Program

Solution Overview. Asset Condition Monitoring. Extend operational life and reduce downtime

2006 Thermographic Inspection. Terrific Towers 1001 Sparks St Sydney. Vol. 9

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Single-Phase Step Voltage Regulators

500KV BUSHINGS FAILURES AND BUSHING OIL SAMPLING PROGRAM. Mike Lau BC Hydro

We trust the foregoing is satisfactory. If you have any questions or comments, please contact the undersigned.

Transforming Transforming Advanced transformer control and monitoring with TEC

Power Products Division. Power Services Service underpins everything we do

EE064D: Circuit Breakers & Switchgears: Design, Testing, Commissioning, Maintenance, Repair & Troubleshooting

Low and medium voltage service. Power Care Customer Support Agreements

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Industrial Substation Maintenance April $4,250 Abu Dhabi. UAE

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

Experience on Deterioration Survey of Aged 550 kv GIS and Optimized Evaluation Model in Thailand

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

Substation inspection guidelines Mark B. Goff, P.E.

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Transcription:

PR-PUB-NLH-034 NLH 2015 Prudence Review Page 1 of 1 1 2 3 Q. Western Avalon T5 Tap Changer: Please provide the oil quality testing result records for the Western Avalon T5 transformer tap changer compartment for 2010 to January 2014. 4 5 6 7 8 9 10 11 12 A. Hydro completes oil sampling and analysis of tap changer compartments on a three-year cycle as indicated in Hydro's response to PUB-NLH-174 in the Investigation and Hearing into Supply Issues and Power Outages on the Island Interconnected System, attached as PR-PUB-NLH-034 Attachment 1. All oil sample analysis results are reviewed by Hydro engineers and re-sampling and close monitoring occurs if readings fall outside accepted levels to ensure appropriate actions are implemented. 13 14 15 16 17 18 19 For Western Avalon T5, there are two oil quality testing records during this period: one from March 6, 2012 and the other from May 9, 2012. The May 9, 2012 was a re-sample based on Hydro s criteria to take another oil sample within six months if the TASA result is greater than 3. Both records are contained in the attached laboratory report (see PR-PUB-NLH-034 Attachment 2). The tap changer compartment oil was replaced with new oil in July 2012.

1 of 8, 2015 Prudence Review PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4 1 2 3 4 5 6 7 8 9 Q. Please describe Hydro s terminal station and substation inspections policies and practices. In the response include who conducts the inspections treatments, how the inspections and the resulting repairs are tracked, whether inspectors use paper forms or handheld computers, whether Hydro has a formal policy stating the number of inspections to be completed each year and the expected inspection and repair (CM) completion rates, the level of management who monitors the completions consistent with policy and schedules and the title of the person held accountable for the completion of the inspection work consistent with the policy and the schedule. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 A. Hydro s terminal station inspection practices are outlined in PUB NLH 174 Attachment 1 and Hydro s substation inspections practices are outlined in Hydro's response to PUB NLH 174 Attachment 2. Inspections are planned by the regional planning group and are placed in weekly schedules to be executed by the appropriate front line supervisors. The front line supervisors are then tasked with ensuring the weekly schedule is completed as outlined. All work is completed using a work order system and any new work identified during the course of the requested job, is either completed at that time or documented on the work order to ensure there is another work request placed on the system. All work orders are given to the crews in paper copies and they are expected to document the actual work performed on the paper copied work orders. Each work order upon completion is reviewed and signed off by the supervisor to ensure quality of documentation of actual work performed, test results are reviewed and to understand if there is any follow up work required. All new work requests for corrective maintenance (CM) work are typically keyed by an office clerk when they key the actual work performed from the paper copy completed work order.

2 of 8, 2015 Prudence Review 1 2 3 4 5 6 7 PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 2 of 4 Once a new work request comes onto the system, this work order is reviewed by the work execution group to approve the work request for planning and define the priority. The Short Term Planning and Scheduling (STPS) Group assesses the job for parts and labour and once parts are received, the job is placed in a "waiting to be scheduled" status. Jobs waiting to be scheduled are considered in "backlog". To maximize productivity and minimize cost, planners review the backlog to, where possible, group work for a given location. 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 For preventative maintenance (PM) work, the STPS Group will generate the PM work orders within the Computerized Maintenance Management System (CMMS) in accordance with the frequency as set up within the management system. PM activities are identified on the annual work plan and are placed in the weekly schedule by the planner responsible for the given area. Like CM work orders, workers use paper copies of the work orders but in the case of PMs, maintenance staff also use paper checksheets to document their findings. Checksheets along with the completed work orders are reviewed and signed off by the supervisor. If equipment problems were identified, the supervisor would either contact a management person in the Work Execution Group or contact an equipment engineer or asset specialist within the Long Term Asset Planning Group for further direction. All completed work orders, after being reviewed by the supervisor, are passed along to an office clerk for keying the actual work performed into the CMMS system and also scanning the work order and the associated checksheets. All PM work orders are also sent to the asset specialist for a follow up review. 24 25 26 27 Hydro schedules inspections in accordance with its PM program, which varies by equipment. At this point, Hydro has not established a formal policy stating the number of inspections to be completed each year and the expected inspection and

3 of 8, 2015 Prudence Review 1 2 PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 3 of 4 repair (CM) completion rates. However, Hydro does set an annual inspection (PM) target of 90% of the inspections planned for each year. 3 4 5 There are three functions of asset management that ensure inspections are identified, scheduled, executed and tracked. They are: 6 7 8 9 10 11 1. Long Term Asset Planning (LTAP) the LTAP Manager is accountable for developing the preventive maintenance program. Accountability's include setting/modifying inspection frequencies, determining/modifying maintenance tactics and ensuring the PM program is set up in the CMMS. The LTAP Manager also tracks any changes to the PM program. 12 13 14 15 16 17 18 19 20 21 22 23 24 2. STPS the STPS Supervisor ensures the PM program is included on the annual work plan, that revisions/additions to PMs are entered into the CMMS, all activities have resources identified and that weekly work schedules are developed. The STPS Supervisor also tracks progress of the annual work plan through monthly reports and annual work plan review meetings. 3. Work Execution (WE) the WE Manager is accountable for execution of the PM program as identified in weekly schedules and annual work plans and to report back through the STPS Supervisor any deviation of actual work completed verses plan. The WE manager also ensures details of actual work completed are recorded in the CMMS and that corrective maintenance work orders are initiated for deficiencies found during PM inspections. 25 26 27 The Regional Manager is accountable for oversight and measurement of the STPS and WE functions and to ensure recovery plans are in place when the actual work

4 of 8, 2015 Prudence Review 1 2 3 4 5 6 PUB NLH 174 Island Interconnected System Supply Issues and Power Outages completed deviates from the plan. In addition, the Regional Manager is Page 4 of 4 accountable for reporting progress of the PM program to the General Manager and status of any required recovery plans. The General Manager is ultimately accountable for all facets of asset management and to be fully engaged in ensuring recovery plans are in place and that performance measures are reported to the Leadership Team.

5 of 8, 2015 Prudence Review PUB-NLH-174, Attachment 1 Page 1 of 3, Isl Int System Power Outages Air System Monthly PM Air System Annual PM Summary of Inspection Practices in Terminal Stations Check oil, belts, record running hours, discharge system to check cut in/out of compressors, clean unloaders, check filters, operate dryer, and take dew point. Check Dew point Change filters, change oil, replace desiccant, clean condensate drain, function test compressors and dryers, and complete ultrasonic leak detection. 120 Day Station PM (some are 180 Day) Station Annual Infrared Scanning PM Breaker Annual PM Visually inspect building and grounds, check battery bank and chargers, compressors and dryers (if applicable), visually inspect transformers, breakers, CT's, PT's and disconnects, confirm terminal station supplies, and change eye wash station solution. Complete a scan of each connection in station using infrared camera looking for hot spots. Operate breaker locally and remotely to confirm operation Breaker 6 Year PM Breaker Air System Annual PM OCB Oil Sample PM (BOA) (3 year PM) Air Blast Conduct ductor, timing, trip coil measurement, check auxiliary contact, check pressure switches, function test breaker, measure trip coil resistance SF6 Check SF6 pressure, timing, operating mechanism pressure, ductor, measure trip coil resistance, check pressure settings, check primary connections, lubricate mechanism and function test breaker. OCB Change oil in compressor. Check dash pot oil level, breaker in open position. Check pressure switches and record if applicable. Inspect contactors. Lubricate Operating mechanism. Measure and record run time of compressor from cut in to cutout Measure interrupter resistors ( 138 KV kso only ) Check bushings and wipe down if required. Complete a dielectric test ASTM 877 of the oil. Perform megger of each phase to ground with the breaker in the closed position. Perform ductor. Items added in 2014 are : to make timing and doble a required test for OCB's, make timing test a required test for all 69 kv breakers and above (regardless of type and function) in areas that currently have timing sets. Other areas to start timing tests in 2015. For SF6 and Air Blast 230 kv breakers, function test breaker through the protection. Check Dew Point, Change filters, change oil, replace desiccant, clean condensate drain, function test compressors and dryers Complete oil analysis for condition ranking of Oil Circuit Breakers

6 of 8, 2015 Prudence Review PUB-NLH-174, Attachment 1 Page 2 of 3, Isl Int System Power Outages Transformer Oil Sample Annual PM (DGA and Oil Quality) Summary of Inspection Practices in Terminal Stations Tap Changer Oil Sample PM (TASA) (3 year PM) Power Transformer 6 Year PM Sample all non sealed transformers annually or as recommended by Equipment Engineer for Dissolved Gas Analysis and Oil Quality. (Sealed units are completed every three years). Furan analysis is completed every 4 years Complete DGA and particle count analysis for condition ranking of tap changers Perform oil dielectric for main tank and diverter switches (as required), testing of protective devices (gas relay, fault pressure devices, winding and oil temperature devices), winding resistance testing, megger testing, Doble testing, check radiators and radiator fan controls, check main tank for rust, inspects bushings (confirm oil level) and arrestors, check core ground and inspect/replace silica gel. Check filter unit if equipped for diverter switch compartment Disconnect Switch 6 Year PM Instrument Transformer 6 Year PM Capacitor Bank 6 Year PM Manually operate the switch and check contact alignment, toggles, stops, linkage and ease of operation, Check contact pressure observe jaw spread as blade rotates in jaw. On Kearney switches check that the blade is positioned opposite the pressure springs in the jaws. Check contacts for burns or wear. Check the silver plating for peeling or deterioration. Check hinge end shunts or wiping contact. Clean contacts and lubricate by applying grease and then removing so there is only a light film left. Lubricate linkage pivot points. If the switch is equipped with arcing horns, see that beads of material caused by burning are removed. Lubricate gears. Check ground mats. Test operate manually and electrically (locally and remote). Contacts on auxiliary switches and motor circuits should be cleaned. Apply a light film of grease to the gear train. Visually inspect bushings, inspect junction boxes gaskets etc., check oil level and rust condition, check heaters and perform doble test (Updated as a required test in 2014 and will be will be implemented over a 6 year cycle) Check primary connections, check grounding connections, clean bushings and support Insulators, check all fuses, record nameplate capacitance per phase, Measure capacitance for each phase. Compare to nameplate values, perform 5 kv Megger test phase to ground, check for leaks, after capacitor bank is energized record load current and voltage.

7 of 8, 2015 Prudence Review PUB-NLH-174, Attachment 1 Page 3 of 3, Isl Int System Power Outages Battery Annual PM Summary of Inspection Practices in Terminal Stations Station Relay/Meter Maintenance PM (6 year PM) Check D.C. voltage, check that the charger ammeter reading. Check and record the voltage, conductance (MHOS) and temperature of each cell and inter cell connecting straps. Flooded Cells :Measure and record the voltage and specific gravity of the pilot cell. Add water as required to bring levels in all cells to upper limits. Determine the pilot cell by lowest specific gravity. If water is added: Apply an equalize charge for 24 hours at 2.33 volts per cell If the equalize charge does not return the specific gravity of the pilot cell to normal, continue the equalize charge for another 24 hour period. Check each cell for cracks, corrosion and Leaks. Inspect the plates for deterioration, buckling, etc. Working with FM Global as well on discharge testing critical battery banks on a 5 year cycle for flooded cell and a lower frequency for critical valve regulated lead acid (VRLA) Complete relay testing of all protection relays in the station through current and voltage injections. Use Doble Protest Software to record test results. Complete function testing of the protection circuits.

8 of 8, 2015 Prudence Review PUB-NLH-174, Attachment 2 Page 1 of 1, Isl Int System Power Outages Summary of Inspection Practices in Sub Stations Visually inspect building and grounds, check all pole structures and associated hardware. Visually inspect all sub station Substation PM 120 days equipment (regulators/reclosers) for general condition and signs of oil leaks. Reclosers and associated hardware will be visually inspected by Recloser Monthly members of the linecrew. Demand load readings, counter operations and battery voltage will be recorded Visual inspection to be performed by electrical maintenance personnel which will include battery/charger and lamp test. Recloser 120 Day Inspection also looks for sign of arcing, cracked bushings, deteriorated gaskets, oil leaks and signs of rust on both the recloser and the control cabinet. Visual inspection to be performed by electrical maintenance personnel which will include battery/charger and lamp test. Recloser Annual Inspection also looks for sign of arcing, cracked bushings, deteriorated gaskets, oil leaks and signs of rust on both the recloser and the control cabinet. Recloser Duty Cycle Frequency varies. The number of operations and magnitude of load current and fault operations are governing factors. Recloser is de tanked and the interior is inspected for signs of water ingress and carbon build up. Oil is changed if necessary. Mechanism is cleaned and contacts inspected for burns and loose connections. Recloser is also fully function tested. Regulator Monthly Regulator 120 Day Regulator 3 5 Year Regulators and associated hardware will be visually inspected by members of the linecrew. Regulator readings, counter operations and test terminal voltages to be recorder. Visual inspection to be performed by electrical maintenance personnel. Inspection also looks for sign of arcing, cracked bushings, deteriorated gaskets, oil leaks and signs of rust on both the regulator and the control cabinet. Visual check of all primary connections, and switches for signs of overheating. Regulator is also manually operated to confirm correct operation. Visual inspection to be performed by electrical maintenance personnel. Inspection also looks for sign of arcing, cracked bushings, deteriorated gaskets, oil leaks and signs of rust on both the regulator and the control cabinet. Visual check of all primary connections, and switches for signs of overheating. Complete meggar test on windings and an oil insulation test. Regulator is also manually operated to confirm correct operation.

PR-PUB-NLH-034, Attachment 2 Page 1 of 1, 2015 Prudence Review Tapchanger Activity Signature Analysis TASA TM David Hicks Location : W.A.V Date : 5/11/2012 Newfoundland Labrador Hydro Bank & Phase : Report Number : 5040672 Serial Number : 066205-LTC Purchase Order Number: 914315 P.O. Box 12400 Ventilation : Manufacturer : MR Reinhausen St John's, NF A1B 4K7 Compartment : Transfer Model : H111D40014510193W Sample Date : 5/9/2012 3/6/2012 Laboratory No. : 5040672 5040113 Container No. : 19157 19660 Temperature : 30 35 H2 Hydrogen (ppm) : 34195 14183 CH4 Methane (ppm) : 2514 24 C2H6 Ethane (ppm) : 122 41 C2H4 Ethylene (ppm) : 2018 618 C2H2 Acetylene (ppm) : 2291 617 CO Carbon monoxide (ppm) : 385 151 CO2 Carbon dioxide (ppm) : 72 185 N2 Nitrogen (ppm) : 54290 101868 O2 Oxygen (ppm) : 6645 24789 Total (ppm) : 102532 142476 TDCG (ppm) : 41525 15634 SHL (%) : 4.01 4.01 ETCG (% in blanket) : 51.10 17.71 Particles 5 to 15 um : 9590 15075 Particles 15 to 25 um : 750 945 Particles 25 to 50 um : 200 100 Particles 50 to 100 um : 20 5 Particles > 100 um : 0 0 D1533 Moisture (ppm) : 8 6 D1816 Dielectric BV (kv) : 35 36 D974 Acid Number (mg KOH/g) : 0.005 0.018 D971 Interfacial Tension (dynes/cm) : 39.6 37.2 D1500 Color Number : 0.5 <2.0 Tapchanger Activity Signature Analysis Diagnostic Evaluation TASA Assessment : 3 Sampling Interval : Recommend retest within in 90 days. Schedule overhaul within 6 months. Operating Procedure : Monitor for increased heating. Evaluate range of LTC operation. Evaluate heating at different contacts. Comments : A moderately abnormal dissipation of energy is noted. This is an advancing indication of fault or wear activity. Partial discharge is indicated. Heating is indicated. Follow guidelines for oils with high flammable gas content. TJH2B Analytical Services, Inc. Bay #1, 2835-19 Street N.E. Calgary, AB T2E 7A2 Canada Phone: (403) 282-8542 Sacramento, CA (916) 361-7177 / Jefferson, LA (504) 734-9722 / Sun Prarie, WI (608) 825-2022 / Kennett Square, PA (610) 925-0688 Glen Waverly, Australia +61 3 9574 9467 / Chester, United Kindom +44 0 151 339 5100